• Title/Summary/Keyword: 가진 시스템

Search Result 3,418, Processing Time 0.031 seconds

Design of Large Multi-Electromagnetic Shaking System (대형 멀티 전자기 가진 시스템 설계)

  • Im, Jong-Min;Moon, Sang-Moo;Eun, Hee-Kwang;Choi, Seok-Weon;Choi, Joon-Min
    • Aerospace Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.76-81
    • /
    • 2008
  • The vibration test system of satellite environment test dept. has been used successfully for the vibration tests of a majority of korean space programs. To meet the recent needs of large size test facility available for the vibrational tests of the huge launch vehicles and satellites, KARI have developed the large size multi-electromagnetic shaking system with $3{\times}3m$ head expander system. The new system will consist of three electromagnetic shakers which has 160 kN thrust force individually, and be able to sustain up to 8 tons test load and 300 kNm overturing moment. This paper describes the design components in the development process of multi-excitation shaker system.

  • PDF

Verification of Vibration Test System for Geostationary Satellite (정지궤도위성 진동시험을 위한 가진 시스템 검증)

  • Im, Jong-Min;Moon, Sang-Moo;Eun, Hee-Kwang;Moon, Nam-Jin;Lee, Dong-Woo;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.143-152
    • /
    • 2010
  • Development and verification of whole vibration test system was requested for developing a geostationary satellite. This satellite is enlarged significantly compared with fore-satellite in KARI. For vertical vibration test, new vertical vibration system was developed. For lateral vibration test, thermal equilibrium test was performed because of difference of thermal characteristics between test adapter and slip table. And lateral vibration system performance for overturning moment was verified by analysis and test. As the number of acquisition channels was increased, new shaker control and data acquisition system was installed. In this paper, verification process and techniques to improve test stability are introduced for the whole vibration test system.

Why Systems Analysts Ignore Socio-Organizational Concerns During Systems Analysis\ulcorner

  • 김종욱;김병곤
    • The Journal of Information Systems
    • /
    • v.9 no.1
    • /
    • pp.189-216
    • /
    • 2000
  • 오늘날 정보시스템 실패의 많은 원인이 기술적인 문제만을 중시하고 정보시스템과 관련된 조직, 또는 관리적인 요소들을 소홀히 하기 때문이라는 지적이 있다. 여러 MIS 학자들은 정보시스템 개발 시 이러한 기술적인 관점에로의 편중의 원인을 시스템 개발자들이 가진 편협된 준거체계(Frame of reference)에서 찾고 있다. 그러나 이러한 주장들은 아직까지 단순히 이론적인 단계에 그치고 있는데, 본 연구는 이러한 주장에 대한 실증적 근거를 제시하고자 한다. 그 방안으로 본 연구는 시스템 분석가의 준거체계와 시스템 개발 시 분석가가 발견하는 개발시의 문제의 유형간의 관계를 제시하고 있다. 본 연구의 결과 사회-기술적(Socio-technical)이거나 사회적인(Socio) 준거체계를 가진 분석가들이 기술적인(Technical) 준거체계를 가진 분석가들보다 더 조직적인 문제를 많이 발견하고 중시함이 나타났다. 그리고 통계적으로 유의하지는 않았지만, 사회-기술적인 시스템 분석가들이 사회적이거나 기술적인 준거체계를 가진 분석가들 보다 기술과 조직적인 문제 모두에 균형있는 관점을 유지하고 있음을 알 수 있었다. 이러한 본 연구의 연구결과는 학문적이며 실무적인 시사점을 제시하고 있다. 우선 학문적 시사점을 살펴보면, 시스템 개발 현장에서 조직과 관리적인 관점의 문제가 소홀히 다루어지는 원인을 알아 볼수 있는 이론적 배경을 제공하고 있다는 것이다. 그리고 실무적 시사점은 보다 균형 있는 시각을 가진 시스템 분석가를 만들기 위하여 학교 프로그램에서 어떤 교과과정을 만들어야 하며, 또 기업의 정보시스템 관리자들이 평소에 어떤 문제들을 보다 많이 강조하고 상기시켜야 할 필요가 있는지를 알려 준다는 것이다.

  • PDF

Realization of Vibrator driving system Using Transverse Flux Linear Motor (횡자속 선형 전동기를 이용한 가진기 구동 시스템 구현)

  • Lim, Tae-Yun;Kim, Jong-Moo;Kang, Do-Hyun;Kim, Dong-Hee;Yang, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.577-579
    • /
    • 2001
  • 본 논문에서는 공진을 이용한 일정 진폭과 일정 주파수용 가진기 구동 시스템의 구현을 위한 제어기와 시스템에 대한 동적 해석을 수행하였다. 제안된 가진기 시스템의 엑츄에이터는 영구자석형 횡자속 선형 전동기(TFLM)가 적용되었고 가진기의 이동자에는 공진용 스프링을 장착하였다. 이로써 TFLM의 구조적인 장점인 고출력과 공진을 통한 에너지의 고효율의 장점을 갖는 전동식 가진기 시스템을 구현할 수 있게 되었다.

  • PDF

Development of a Wireless Piezoelectric Transducer Excitation Technique using laser and optoelectronic devices (레이저 및 광전자소자를 활용한 압전소자의 무선 가진 시스템 개발)

  • Park, Hyun-Jun;Sohn, Hoon;Chung, Joseph;Kwon, Il-Bum;Yun, Chung-Bang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.6-9
    • /
    • 2009
  • 교량, 댐, 터널 등의 대형 구조물 및 항공기 등의 기계 구조물의 경우 그 중요성과 함께 노후화 및 손상의 발생에 의한 구조물의 사고를 미연에 방지하기 위해 효과적인 건전도 평가와 손상 검색에 대한 연구가 최근 급증하고 있으며 특히 압전소자를 활용하여 구조물의 손상을 추정하는 기법들이 많이 개발되고 있다. 또한, 최근에는 압전소자와 계측기 사이를 케이블을 이용하여 연결할 경우 실제 대형 구조물에 설치 시 비효율적인 부분이 많아 무선 기반 계측시스템이 개발되고 있다. 그러나 이러한 무선 계측 시스템의 경우 압전소자의 가진 및 계측되는 데이터의 전송을 위해 별도의 전원공급이 필요하기 때문에 배터리가 포함되도록 구성되며 이럴 경우 그 수명이 제한적이기 때문에 실제 구조물에 활용 시 문제로 제기되고 있다. 이러한 배경에서 본 연구에서는 레이저를 통해 원격지의 압전소자에 무선으로 전원을 공급하여 가진시키는 시스템을 제안하였다. 압전소자를 가진시키고자 하는 임의의 파형으로 레이저를 변조(modulation)시키고 대기 중으로 전송하여, 압전소자와 연결된 광검출기(photodiode)를 통해 전기적 신호로 변환하여 최종적으로 가진시키게 된다. 이러한 시스템을 실내 실험을 통하여 구현하였으며 그 효용성을 살펴보았다.

  • PDF

Use of Higher Order Frequency Response Functions for Non-Linear Parameter Estimation (고차 주파수응답함수를 이용한 비선형 시스템의 매개변수 추정)

  • 이건명
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.40-45
    • /
    • 1994
  • 기계시스템의 비선형특성 해석을 위하여 여러가지 방법이 활용되고 있는데, 이들은 Nyquist 선도의 찌그러짐(distortion), Hilbert 변환, 복원력면(restoring force surface), NARMAX, 고차 주파수응답함수(higher order frequency response function), DPE(direct parameter estimation)를 이용한 방법등이다. 이들중 고차 FRF(frequency response function)는 그 개념이 선형시스템의 FRF와 유사하여 비선형시스템의 해석방법으로서 주목을 받고 있으나 아직은 고차 FRF의 특성에 대한 이론적 연구 단계이고, 고차 FRF로부터 비선형특성을 정량적으로 해석하는 연구는 거의 이루어지지 않고 있다. 다항식으로 표시되는 비선형성을 갖는 시스템이 정현파가진을 받을 때 그 응답의 가진주파수 성분은 가진력진폭과 고차 FRF의 무한급수로 나타낼 수 있다. 가진력의 진폭을 변화시켜가며 응답을 측정하고, 고차항을 무시하면 고차 FRF의 값을 근사적으로 구할 수 있다. 고차 FRF는 비선형 시스템의 매개변수의 식으로 나타낼 수 있으므로 이로부터 비선형 매개변수를 추정할 수 있다. 본 논문에서는 비선형강성과 비선형감쇠를 갖는 1자유도 시뮬레이션 시스템에 이 매개변수 추정법을 각각 적용함으로써 이 방법의 가능성을 고찰하였다.

  • PDF

Comparative Study on Seismic Performance of Viscously Damped Self-Centering SDOF Systems with Elasto-Plastic SDOF Systems (점성 감쇠기를 가진 셀프 센터링 단자유도 시스템과 탄소성거동의 단자유도 시스템의 내진성능 비교에 관한 연구)

  • Kim, Hyung-Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.553-561
    • /
    • 2010
  • The purpose of this paper is to analytically find the approximate supplement damping ratio of the viscous damper installed in self-centering (SC) single-degree-of-freedom (SDOF) systems with maximum displacements that are similar to those of elasto-plastic (EP) SDOF systems. The behavior of an SC SDOF system under harmonic cyclic loading was first described. Then an analytical model that can capture the behavior of the viscously damped SC SDOF system was introduced. Analysis parameters that characterize the hysteresis of the EP and SC SDOF systems were chosen, and nonlinear time-history analyses were performed using 20 historical accelerograms. Most of the SC SDOF systems with viscous dampers with approximately 10-15% damping ratios presented mean maximum displacement values that were similar to those of the EP SDOF systems. To investigate in detail the seismic performance of both systems, three EP SDOF systems and six corresponding SC SDOF systems were selected. The analyses showed that all the SC SDOF systems eliminated the residual displacements after the end of their shaking, and that the SC SDOF systems with 15% damping ratios performed better than the EP SDOF systems in terms of maximum displacement and acceleration response.

Electrical Noise Reduction in the Electromagnetic Shaker System using a Class-D Amplifier (Class-D 증폭기를 사용한 가진기 시스템의 전기적 잡음 감소)

  • 윤을재;김인식;한태균
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.4
    • /
    • pp.12-22
    • /
    • 1999
  • Operation of an electromagnetic shaker system using a Class-D amplifier may cause unacceptable electromagnetic interference to another electronic system, requiring the user to take whatever steps are necessary to correct the interference. A differential amplifier in a Class-D amplifier is used to decrease the effect of a common-mode noise voltage in a shaker system. To prevent a ground loop, a transformer is inserted in another shaker system. These methods show reduction of the unwanted vibration which has occurred before. A transformer in a charge amplifier was used to prevent a ground loop in a shaker system using a Class-AB amplifier a few years ago, but it was susceptible of noise in a shaker system using a Class-D amplifier. Hence we corrected a ground loop between a charge amplifier and a vibration control/analysis system without a transformer. The usefulness of this approach is illustrated by the results of experiments.

  • PDF

Design of an Excitation System for Simulating Wind-Induced Response and Evaluating Wind-load Resistance Characteristics (건축구조물의 풍하중 구현 및 풍특성 평가를 위한 가진시스템 설계)

  • Park, Eun-Churn;Lee, Sung-Kyung;Min, Kyung-Won;Chun, Lan;Kang, Kyung-Soo;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.769-778
    • /
    • 2007
  • In this paper, excitation systems using linear mass shaker (LMS) and active tuned mass damper (ATMD) are presented in order to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. Filter and envelop function are used such that the error between the wind and actuator induced responses is minimized by preventing the actuator from exciting unexpected modal response and initial transient response. The analyses results from a 76-story benchmark building problem in which wind load obtained by wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately embody the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

A Control of Vibrator Using PM Excited Transverse Flux Linear Motor (영구자석 여자 횡축형 선형 전동기(TFLM)를 이용한 가진기 제어)

  • 임태윤;강도현;김종무;김동희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.281-288
    • /
    • 2002
  • This paper has realized a control system of a vibrator using PM excited Transverse Flux Linear Motor(TFLM). Proposed vibrator can supply a vibration force up to 700[N] at rated current, wide operation range of vibration displacement and high frequency for a tested structure. Also, volume of a vibrator system can be decreased because of a high trust force rato(a thrust force per weight=N/Kg). A proposed vibrator instead of a hydraulic vibrator can improve efficiency and have may advantages of maintenance and management. A desired value command is a vibration frequency and displacement in a controller for a vibrator system and a controlled values we a instant position and velocity of a mover Output value of the controller is phase current controlled by PWM converter. In this research, Dynamic simulation has been executed for analysis of a control algorithm and dvnauuc characteristics and is compared with experimental result.