Electrical Noise Reduction in the Electromagnetic Shaker System using a Class-D Amplifier

Class-D 증폭기를 사용한 가진기 시스템의 전기적 잡음 감소

  • Published : 1999.12.01

Abstract

Operation of an electromagnetic shaker system using a Class-D amplifier may cause unacceptable electromagnetic interference to another electronic system, requiring the user to take whatever steps are necessary to correct the interference. A differential amplifier in a Class-D amplifier is used to decrease the effect of a common-mode noise voltage in a shaker system. To prevent a ground loop, a transformer is inserted in another shaker system. These methods show reduction of the unwanted vibration which has occurred before. A transformer in a charge amplifier was used to prevent a ground loop in a shaker system using a Class-AB amplifier a few years ago, but it was susceptible of noise in a shaker system using a Class-D amplifier. Hence we corrected a ground loop between a charge amplifier and a vibration control/analysis system without a transformer. The usefulness of this approach is illustrated by the results of experiments.

Class-B 증폭기를 사용하는 가진기 시스템의 운용으로 인하여 다른 전자 시스템에 전자파 장해가 나타날 수 있으며, 이런 경우에 사용자가 이 장해를 해결하기 위하여 필요한 대책을 마련하기를 요구하고 있다. 한 가진기 시스템에서는 공통모드 잡음전압의 효과를 줄이기 위하여 Class-D 증폭기에서 차동증폭기가 사용되었고, 다른 가진기 시스템에서는 접지루프를 막기 위하여 변압기가 삽입되었다. 이 방법들은 이전에 발생하였던 불필요한 진동의 감소를 보여주고 있다. 전하증폭기의 변압기가 접지루프를 방지하기 위하여 Class-AB 증폭기를 사용한 가진기 시스템에서 수 년간 사용되었으나, Class-D 증폭기를 사용하는 가진기 시스템에서 이것은 잡음에 민감하였다. 따라서 전하증폭기와 진동 제어분석 시스템 사이의 접지루프를 변압기를 사용하지 않고 해결하였다. 이 방법의 유용성이 실험결과를 통하여 확인되었다.

Keywords