• Title/Summary/Keyword: 가시광선투과도

Search Result 289, Processing Time 0.031 seconds

The Effect of Blue Light Interception and SPF Boosting of Sunscreen Prepared with Bandgap-controlled TiO2 (밴드갭이 제어된 TiO2 를 이용한 자외선 차단제의 블루라이트 차단 및 SPF 부스팅 효과)

  • Sung Eun Wang;Jung Kyung Yoon;Gui Su Chung;Sung Bong Kye;Ho Sik Rho;Dae Soo Jung
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.2
    • /
    • pp.159-167
    • /
    • 2023
  • Titanium dioxide (TiO2) is commonly used in sunscreen formulations to protect the skin surface and prevent the penetration of harmful ultraviolet (UV) rays by the physical scattering action of light. However, a disadvantage of using TiO2 is that it can cause white turbidity when used on skin due to its inactive mineral ingredient. In addition, when TiO2 particles are reduced to nanosize to eliminate opacity, they can increase the transmittance of visible light and reduce whitening, but may lead to serious skin problems, such as allergic inflammation. To overcome these issues, the bandgap of TiO2 was controlled by adjusting the amount of oxygen defect and nitrogen amount, resulting in color TiO2 tailored to the skin. This innovative technology can reduce the whitening phenomenon and effectively block blue light, which is known to cause skin aging by inducing active oxygen. The bandgap controlled TiO2 compounds proposed in this study are hypoallergenic, broad-spectrum, and environmentally friendly. Furthermore, these compounds have been shown to significantly enhance sun protection factor (SPF) of sunscreens, demonstrating their compatibility with blue light blocking products.

MOCVD Growth and Characterization of Heteroepitaxial Beta-Ga2O3 (MOCVD 성장법을 이용한 Beta-Ga2O3 박막의 헤테로에피택시 성장 특성)

  • Jeong Soo Chung;An-Na Cha;Gieop Lee;Sea Cho;Young-Boo Moon;Myungshik Gim;Moo Sung Lee;Jun-Seok Ha
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.2
    • /
    • pp.85-91
    • /
    • 2024
  • In this study, we investigated a method of growing single crystal 𝛽-Ga2O3 thin films on a c-plane sapphire substrate using MOCVD. We confirmed the optimal growth conditions to increase the crystallinity of the 𝛽-Ga2O3 thin film and confirmed the effect of the ratio between O2 and Ga precursors on crystal growth on the crystallinity of the thin film. The growth temperature range was 600~1100℃, and crystallinity was analyzed when the O2/TMGa ratio was 800~6000. As a result, the highest crystallinity thin film was obtained when the molar ratio between precursors was 2400 at 1100℃. The surface of the thin film was observed with a FE-SEM and XRD ω-scan of the thin film, the FWHM was found to be 1.17° and 1.43° at the and (${\bar{2}}01$) and (${\bar{4}}02$) diffraction peaks. The optical band gap energy obtained was 4.78 ~ 4.88 eV, and the films showed a transmittance of over 80% in the near-ultraviolet and visible light regions.

Polymerization of HEMA by Electron beam Irradiation and Fabrication of Soft contact lens (전자빔조사에 의한 HEMA의 중합과 소프트콘택트렌즈 제조)

  • Hwang, Kwang-Ha;Shin, Joong-Hyeok;Sung, Yu-Jin;Jeong, Keun-Seung;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.135-141
    • /
    • 2012
  • Purpose: Polymerization of HEMA(2-hydroxyethyl methacrylate) which can be used in the soft contact lens has been performed by using electron beam(EB) irradiation, and examined the best condition for the polymerization. Comparing the physical properties of the contact lenses to the one fabricated by thermal polymerization method, we check the use possibility of the EB irradiation to the fabrication of the soft contact lens. Methods: We investigated the degree of polymerization of the HEMA according to the composition of the monomer, the additive ratio and the dose of electron beam (0~120 kGy). The degree of polymerization was measured depending on the EB dose to research the best synthetic condition under the EB irradiation. The physical properties of the contact lens such as water content(%), oxygen transmissibility(Dk/t) and optical transmittance were analysed by using the FT-IR results with comparing the two different polymerization method (thermal and electron beam polymerization) with same additive ratio. Results: When the dose of electron beam was above 100 kGy, the degree of polymerization of HEMA was above 99% with regardless using cross-linker and initiator. The water content of the lens fabricated by EB method showed 10% higher than the one by the thermal method which was 40%. The lens fabricated by EB method also showed higher oxygen transmissibility(Dk/t) as same with the water content, and showed twice higher value in the lens fabricated by pure HEMA. According to the FT-IR results, hydrophilic property of the lens fabricated by EB method was increased due to increasing the intermolecular hydrogen bonding. It showed above 90% optical transmittance in the visible range of wavelength on the contact lenses fabricated by the both of two different polymerization method. Conclusions: The polymerization of HEMA without cross-linker and initiator was successful above 100 kGy of EB irradiation. Moreover the lens fabricated from the polymer synthesized by pure HEMA with 100 kGy of EB showed the highest water content and oxygen transmissibility. Therefore EB irradiation is another possible method to synthesize the polymer which can be used for the soft contact lens.

A Study on the Fouling of Ultrafiltration Membranes Used in the Treatment of an Acidic Solution in a Circular Cross-flow Filtration Bench (순환식 막 모듈 여과장치를 이용한 산성용액의 수처리 공정 시 발생하는 한외여과막 오염에 관한 연구)

  • Kim, Nam-Joon;Choi, Chang-Min;Choi, Yong-Hun;Lee, Jun-Ho;Kim, Hwan-Jin;Park, Byung-Jae;Joo, Young-Kil;Kang, Jin-Seok;Paik, Youn-Kee
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.252-260
    • /
    • 2009
  • The effects of the treatment of an acidic solution at pH 2 on polyacrylonitrile ultrafiltration (UF) membranes were investigated using a circular cross-flow filtration bench with a membrane module. A substantial reduction in the membrane permeability was observed after 80 hours' treatment of the acidic solution. In addition, the analyses of the sample solutions by ultraviolet/visible absorption spectroscopy and gas chromatography/mass spectrometry (GC/MS), which were taken from the feed tank as a function of the treatment time, showed that a new organic compound was produced in the course of the treatment. From a thorough search of the mass spectral library we presumed the new compound to be 1,6-dioxacyclododecane-7,12-dione (DCD), one of the well-known additives for polyurethane. Based on further experimental results, including the scanning electron microscope (SEM) images and the solid-state NMR spectra of the membranes used for the treatment of the acidic solution, we suggested that the decrease of the permeate flux resulted not from the deformation of the membranes, but from the fouling by DCD eluted from the polyurethane tubes in the filtration bench during the treatment. Those results imply that the reactivity to an acidic solution of the parts comprising the filtration bench is as important as that of the membranes themselves for effective treatments of acidic solutions, for efficient chemical cleaning by strong acids, and also in determining the pH limit of the solutions that can be treated by the membranes.

Basic Study on the Development of Analytical Instrument for Liquid Pig Manure Component Using Near Infra-Red Spectroscopy (근적외선 분광법을 이용한 돈분뇨 액비 성분분석기 개발을 위한 기초 연구)

  • Choi, D.Y.;Kwag, J.H.;Park, C.H.;Jeong, K.H.;Kim, J.H.;Song, J.I.;Yoo, Y.H.;Chung, M.S.;Yang, C.B.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.113-120
    • /
    • 2007
  • This study was conducted to measure Nitrogen(N), Phosphate($P_2O_5$), Potassium ($K_2O$), Organic matter(OM) and Moisture content of liquid pig manure by Near Infrared Spectroscopy(NIRS) and to develop an alternative and analytical instrument which are used for measurement of N, $P_2O_5$, $K_2O$, OM, and Moisture contents for liquid pig manure. The liquid pig manure sample's transmittance spectra were measured with a NIRS in the wavelength range of 400 to 2,500 nm. Multiple linear regression and partial least square regression were used for calibrations. The correlation coefficient(RSQ) and standard error of calibration(SEC) obtained for nitrogen were 0.9190 and 2.1649, respectively. The RSQ for phosphate, potassium, organic matter and moisture contents were 0.9749, 0.5046, 0.9883 and 0.9777, and the SEC were 0.5019, 1.9252, 0.1180 and 0.0789, respectively. These results are indications of the rapid determination of components of liquid pig manure through the NIR analysis. The simple analytical instrument for liquid pig manure consisted of a tungsten halogen lamp for light source, a sample holder, a quartz cell, a SM 301 spectrometer for spectrum analyzer, a power supply, an electronics, a computer and a software. Results showed that the simple analytical instrument that was developed can approximately predict the phosphate, organic matter and moisture content of the liquid pig manure when compared to the analysis taken by NIRS. The low predictability value of potassium however, needs further investigation. Generally, the experiment proved that the simple analytical instrument was reliable, feasible and practical for analyzing liquid pig manure.

  • PDF

Analysis and Design of half-mirror coating for sunglasses (썬글라스용 반미러(Half-Mirror) 코팅의 분석과 설계)

  • Park, Moon-Chan;Jung, Boo-Young;Hwangbo, Chang-Kwon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.111-117
    • /
    • 2003
  • We collected the domestic and foreign half-mirror coating lens for sunglasses. Their reflectance is measured using Spectrophotometer in order to analysis their optical property and the result which is calculated using Macleod program was compared with measured reflectance. In addition, we designed the new half-mirror coating lens with gold color using TiN material and investigated the optical property of the new half-mirror coating lens. The results obtained from analysis of half-mirror coating lenses are as follow : Two-tone half-mirror coating with silver color is fabricated with [air|$SiO_2$(or $Al_2O_3$)|Cr|glass]. The role of $SiO_2$(or $Al_2O_3$) on Cr improve the hardness of the lens and the thickness of the $Al_2O_3$ with 10 nm is good to show the lens silver color. Incase of color half-mirror coating lens. Blue system is designed by [air|$SiO_2$(66.3)|$TiO_2$(129.0)|$SiO_2$(62.9)|$SiO_2$(26.0)|$TiO_2$(120.3)|$SiO_2$(9.1)|glass], gold system [air|$SiO_2$(60.6)|$TiO_2$(86.2)|$SiO_2$(13.5)|$TiO_2$(86.8)|$SiO_2$(214.38)|glass], green system[air|$SiO_2$(74.3)|$TiO_2$(75.8)|$SiO_2$(44.3)|$TiO_2$(11.6)|$SiO_2$(160.8)|$TiO_2$(12.9)|$SiO_2$(183.3)|$TiO_2$(143.8)|glass], silver system[air|$SiO_2$(21.2)|$TiO_2$(49.7)|$SiO_2$(149.3)|glass]. White half-mirror coating lens has [air|$SiO_2$(17 nm)|$TiO_2$(43 nm)(or $ZrO_2$)|$SiO_2$(87 nm)|polysiloxane($4.46{\mu}m$|glass or CR-19]. It has half-mirror coaling lens which has about 19% reflectance and about 80% transmittance in the range of visible light(400~700nm). we designed the new half-mirror coating lens with gold color, the (x, y) value of the CIE is almost similar to the CIE value of [air|$SiO_2$(170 nm)|TiN(15 nm)|glass].

  • PDF

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

극성 (0001) 및 반극성 (11-22) n-ZnO/p-GaN 이종접합 발광 다이오드의 광전 특성 분석에 대한 연구

  • Choe, Nak-Jeong;Lee, Jae-Hwan;Han, Sang-Hyeon;Son, Hyo-Su;Lee, Seong-Nam
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.310-310
    • /
    • 2014
  • ZnO박막은 넓은 밴드갭 (3.37 eV), 높은 여기 결합 에너지 (60 meV)를 가지는 육방정계 우르자이트(hexagonal wurtzite) 결정구조를 가지는 II-VI족 화합물 반도체로, 가시광선 영역에서의 높은 광학적 투과도 특성과 자외선 파장에서 발광이 가능한 장점을 가진다. 최근, ZnO박막 성장 기술이 상당히 발전하였지만, 아직까지도 p-형 ZnO박막 성장 기술은 충분히 발전하지 못하여 ZnO의 동종접합 LED는 아직 상용화되지 않고 있는 실정이다. 따라서, 많은 연구 그룹에서 p-GaN, p-SiC, p-diamond, p-Si 등과 같은 p-type 물질 위에 n-type ZnO를 성장시킨 이종접합 다이오드가 연구되고 있다. 특히, p-GaN의 경우 ZnO와의 격자 불일치 정도가 1.8 % 정도로 작다는 장점이 있어 많은 연구가 이루어 지고 있다. 일반적으로 c-축을 기반으로 한 극성ZnO 발광다이오드에서는 자발 분극과 압전 분극 현상에 의해 밴드 휨 현상이 발생하고, 이로 인해 전자와 정공의 공간적 분리가 발생하게 되어 발광 재결합 효율이 제한되고 있다는 문제가 발생한다. 따라서, 본 연구에서는 극성 (0001) 및 비극성 (10-10) n-ZnO/p-GaN 발광다이오드의 성장 및 발광 소자의 전기 및 광학적 특성에 대한 비교 연구를 진행하였다. 금속유기 화학증착법을 이용하여 c-면과 m-면 위에 각각 극성 (0001) 및 반극성 (11-22) GaN박막을 $2.0{\mu}m$ 성장시킨 후 Mg 도핑을 한 p-GaN을 $0.4{\mu}m$ 성장시켜 각각 극성 (0001) 및 반극성 (11-22) p-GaN템플릿을 준비하였다. 이후, N2분위기 $700^{\circ}C$에서 3분동안 열처리를 통하여 Mg 도펀트를 활성화시킨 후 원자층 증착법을 이용하여 동시에 극성 및 반극성 p-GaN의 위에 n-ZnO를 $0.11{\mu}m$ 성장시켜 이종접합구조의 발광소자를 형성하였다. 이때, 극성 (0001) p-GaN 위에는 극성의 n-ZnO 박막이 성장되는 반면, 반극성 (11-22) p-GaN 위에는 비극성 (10-10) n-ZnO 박막이 성장됨을 HR-XRD로 확인하였다. 극성 (0001) n-ZnO/p-GaN이종접합 발광다이오드의 전계 발광 스펙트럼에서는 430 nm 와 550 nm의 두 피크가 동시에 관찰되었다. 430 nm 대역의 파장은 p-GaN의 깊은 준위에서 발광하는 것으로 판단되며, 550 nm 피크 영역은 ZnO의 깊은 준위에서 발광되는 것으로 판단된다. 특히, 10 mA 이하의 저전류 주입시 550 nm의 피크는 430 nm 영역보다 더 큰 발광세기를 나타내고 있다. 하지만, 10 mA 이상의 전류주입 하에서는 550 nm의 영역보다 430 nm의 발광세기가 더욱 증가하는 것을 확인할 수 있었다. 이것은 ZnO의 밴드갭이 3.37 eV로 GaN의 밴드갭인 3.4 eV다 작기 때문에 우선적으로 ZnO의 깊은 준위에서 발광하는 550 nm가 더욱 우세하지만, 지속적으로 전류주입 증가에 따른 캐리어 증가시 n-ZnO에서 p-GaN로 전자가 넘어가며 p-GaN의 깊은 준위인 430 nm에서의 피크가 우세해지는 것으로 판단된다. 반면에, 비극성 (10-10) n-ZnO/반극성 (11-22) p-GaN 구조의 이종접합 발광다이오드로 전계 발광 스펙트럼에서는 극성 (0001) n-ZnO/p-GaN에 비하여 매우 낮은 전계 발광 세기를 나타내고 있다. 이는, 극성 n-ZnO/p-GaN에 비하여 비극성 n-ZnO/반극성 p-GaN의 결정성이 상대적으로 낮기 때문으로 판단된다. 또한, 20 mA 영역에서도 510 nm의 깊은 준위와 430 nm의 발광이 관찰되었다. 동일한 20 mA하에서 두 피크의 발광세기를 비교하면 430 nm의 영역은 극성 n-ZnO/p-GaN에 비하여 매우 낮은 값을 나타내고 있다. 이는 반극성 (11-22) p-GaN의 경우 극성 (0001) p-GaN에 비하여 우수한 p-형 특성에 기인한 것으로 판단된다.

  • PDF

DETECTION OF EARLY PROXIMAL CARIES WITH LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증의 진단)

  • Seol, Jae-Heon;Oh, You-Hyang;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.236-246
    • /
    • 2004
  • Artificial carious lesions in various depths were observed with visual examination using light transillumination, bite-wing radiography, laser fluorescence, and dye-enhanced laser fluorescence to determine the reproducibility, correlation of each diagnostic method, diagnostic sensitivity and diagnostic specificity. And optical densities according to demineralized times were measured whether laser fluorescence could be used as a quantitative diagnostic method. The following results were obtained whether laser fluorescence could be used for diagnosis of initial proximal caries. 1. Tau-c values of visual examination was 0.08 which showed lowest reproducibility and those of bite-wing radiography, laser fluorescence, dye-enhanced laser fluorescence were 0.60, 0.48, and 0.64, respectively which showed relatively high reproducibility. 2. The correlation between demineralization time and each examination was the highest in dye-enhanced laser fluorescence$({\gamma}=0.51)$ followed by laser fluorescence$({\gamma}=0.43)$, bite-wing radiograph$({\gamma}=0.35)$, and visual examination$({\gamma}=0.33)$. Dye-enhanced laser fluorescence and laser fluorescence showed significant correlation with demineralization time. 3. The sensitivity of laser fluorescence and dye-enhanced laser fluorescence for diagnosing approximal caries based on bite-wing radiography were 67%, 100% and those of specificity were 57%, 11% which showed diagnostic specificity was relatively lower than sensitivity. 4. The difference in optical density(DFR) between sound teeth and carious lesions according to lesion depth was high with dye-enhanced laser fluorescence compared with laser fluorescence. DFR measured with laser fluorescence according to changes in lesion depth was statistically significant but was not statistically significant with dye-enhanced laser fluorescence. Based on these results, laser fluorescence and dye-enhanced laser fluorescence have comparable diagnostic power as bite-wing radiography in early diagnosis of proximal caries.

  • PDF