• Title/Summary/Keyword: 가동

Search Result 2,853, Processing Time 0.038 seconds

Open-field Experimental Warming and Precipitation Manipulation System Design to Simulate Climate Change Impact (기후변화 영향 모의를 위한 실외 실험적 온난화 및 강수 조절 시스템 설계 연구)

  • Yun, Soon Jin;Han, Saerom;Han, Seung Hyun;Lee, Sun Jeoung;Jung, Yejee;Kim, Seoungjun;Son, Yowhan
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.2
    • /
    • pp.159-164
    • /
    • 2014
  • The objective of this study was to establish an open-field experimental warming treatment and precipitation manipulation system to simulate climate change impact for Pinus densiflora seedlings based on a climate change scenario in Korea. Two-year-old seedlings were planted in a nursery in April, 2013. The air temperature of warmed plots (W) was set to increase by $3.0^{\circ}C$ compared to control plots (C) using infrared lamps from May, 2013. The three precipitation manipulation consisted of precipitation decrease using transparent panel (-30%; $P^-$), precipitation increase using pump and drip-irrigation (+30%; $P^+$) and precipitation control (0%; $P^0$). Initially, the air temperature was $2.2^{\circ}C$ higher in warmed plots than in control plots and later air temperature was maintained close to the target temperature of $3.0^{\circ}C$. The average soil temperature was $3.1^{\circ}C$ higher in warmed plots than in control plots. Also the average soil moisture content after the precipitation manipulation increased by 13.9% in $P^+W$ and decreased by 10.0% in $P^-W$ compared to $P^0W$, and increased by 23.7% in $P^+C$ and decreased by 7.6% in $P^-C$ compared to $P^0C$. It was confirmed that the open-field experimental warming and precipitation manipulation system was properly designed and operating.

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

Postoperative Pulmonary Vein Stenosis (PVS) in Patients with TAPVR (전 폐정맥 환류 이상의 수술 후 폐정맥 협착에 대한 분석)

  • Jung Sung-Ho;Park Jeong-Jun;Yun Tae-Jin;Jhang Won-Kyoung;Kim Young-Hwue;Ko Jae-Kon;Park In-Sook;Seo Dong-Man
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.347-353
    • /
    • 2006
  • Background: Despite recent advances in surgical technique and perioperative care of total anomalous pulmonary venous return (TAPVR), post-repair pulmonary vein stenosis (PVS) remains as a serious complication. We thought that the most important factors of TAPVR repair to prevent PVS were good exposure, proper alignment, and sufficient stoma size. We analyzed our experience retrospectively. Material and Method: Between Jan. 1995 and Feb. 2005, we studied 74 patients diagnosed with TAPVR suitable for biventricular repair. Supra-cardiac type (n=41, 55.4%) was the most common. Mean CPB time, ACC time, and TCA (40.5%, 30/74) time were $92.1{\pm}25.9\;min,\;39.1{\pm}10.6\;min$, and $30.2{\pm}10.7\;min$, respectively. Mean follow-up duration was $41.4{\pm}29.1$ months and follow-up was possible in all patients. Result: The median age and body weight at operation were 28.5 days ($0{\sim}478$ days) and 3.4 kg $(1.4{\sim}9\;kg)$. Early mortality was 4.1% (3/74). Causes of death were pulmonary hypertensive crisis, sepsis, and sudden death. There was PR-PVS in 2 patients (early: 1, late: 1). Both patients were cardiac type TAPVR drained to coronary sinus. Re-operations were done but only one patient survived. Cumulative survival rate in 5 year and percent freedom from PVS were $94.5{\pm}2.7%\;and\;97.2{\pm}2.0%$, respectively. Conclusion: There was no PVS in patients who underwent extra-cardiac anatomosis between LA and CPVC. Therefore it could be said that our principle might be effective in preventing PR-PVS in patients suitable two-ventricle.

Emergency Coronary Artery Bypass Operation for Card iogen ic Shock (심인성 쇼크에 대한 응급 관상동맥 우회술)

  • 김응중;이원용
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.966-972
    • /
    • 1997
  • Between June 1994 to August 1996, 13 patients underwent emergency coronary artery bypass operations. There were 3 males and 10 females and ages ranged from 56 to 80 years with the mean of 65.5 years. The indications for emergency operations were cardiogenic shock in 12 cases and intractable polymorphic VT(ve'ntricular tachycardia) in 1 case. The causes of cardiogenic shock were acute evolving infarction in 6 cases, PTCA failure in 4 cases, acute myocardial infarction in 1 case, and post-AMI VSR(ventricular septal rupture) in 1 case. Pive out of 13 patients could go to operating room within 2 hours. However, the operations were delayed from 3 to 10 hours in 8 patients due to non-medical causes. In 12 patients, 37 distal anastomoses were constructed with only 3 LITA's(left internal thoracic arteries) and 34 saphenous veins. In a patient with post-AMI VSR, VSR repair was added. In a patient with intractable VT and critical sten sis limited to left main coronary artery, left main coronary angioplasty was performed. Pive patients died after operation with the operative mortality of 38.5%. Three patients died in the operating room due to LV pump failure, one patient died due to intractable ventricular tachycardia on postoperative second day, and one patient died on postoperative 7th day due to multi-organ failure with complications of mediastinal bleeding, low cardiac output syndrome, ARF, and lower extremity ischemia due to IABP. In 8 survived patients, 3 major complications (mediastinitis, PMI, UGI bleeding) developed but eventually recovered. We think that the aggressive approach to critically ill patients will salvage some of such patients and the most important factor for patient salvage is early surgical intervention before irreversible damage occurs.

  • PDF

Survey of Physicochemical Methods and Economic Analysis of Domestic Wastewater Treatment Plant for Advanced Treatment of Phosphorus Removal (총인 수질기준강화를 위한 국내 하수종말처리장의 물리화학적처리 특성조사 및 경제성 분석)

  • Park, Hye-Young;Park, Sang-Min;Lee, Ki-Cheol;Kwon, Oh-Sang;Yu, Soon-Ju;Kim, Shin-Jo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.212-221
    • /
    • 2011
  • Wastewater treatment plants (WWTPs) are required to meet the reinforced discharge standards which are differentiated as 0.2, 0.3 and 0.5 mg-TP/L for the district I, II and III, respectively. Although most of WWTPs are operating advanced biological phosphorus removal system, the supplementary phosphorus treatment facility using chemical addition should be required almost at all WWTPs. Therefore, water quality data from several exemplary full-scale plants operating phosphorus treatment process were analyzed to evaluate the reliability of removal performance. Additionally, a series of jar tests were conducted to find optimal coagulants dose for phosphorus removal by chemical precipitation and to describe characteristics of the reaction and sludge production. Chemical costs and the increasing sludge volume in physicochemical phosphorus removal process were estimated based on the results of jar tests. The minimum coagulant (aluminium sulfate and poly aluminium chloride) doses to keep TP concentration below 0.5 and 0.2 mg/L were around 25 and 30 mg/L (as $Al_2O_3$), respectively, in the mixed liquor of activated sludge. In the tertiary treatment facility, relatively lower coagulant doses of 1/12~1/3 the minimum doses for activated sludge were required to achieve the same TP concentrations of 0.2~0.5 mg/L. Increase in suspended solids concentration due to chemical precipitates in mixed liquor was estimated at 10~11%, compared to the concentration without chemical addition. When coagulant was added into mixed liquor, chemical (aluminium sulfate) cost was estimated to be 4~10 times higher than in secondary effluent coagulation/separation process. Sludge production to be wasted was also 4~10 times higher than secondary effluent coagulation/separation process.

High-Resolution Numerical Simulations with WRF/Noah-MP in Cheongmicheon Farmland in Korea During the 2014 Special Observation Period (2014년 특별관측 기간 동안 청미천 농경지에서의 WRF/Noah-MP 고해상도 수치모의)

  • Song, Jiae;Lee, Seung-Jae;Kang, Minseok;Moon, Minkyu;Lee, Jung-Hoon;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.4
    • /
    • pp.384-398
    • /
    • 2015
  • In this paper, the high-resolution Weather Research and Forecasting/Noah-MultiParameterization (WRF/Noah-MP) modeling system is configured for the Cheongmicheon Farmland site in Korea (CFK), and its performance in land and atmospheric simulation is evaluated using the observed data at CFK during the 2014 special observation period (21 August-10 September). In order to explore the usefulness of turning on Noah-MP dynamic vegetation in midterm simulations of surface and atmospheric variables, two numerical experiments are conducted without dynamic vegetation and with dynamic vegetation (referred to as CTL and DVG experiments, respectively). The main results are as following. 1) CTL showed a tendency of overestimating daytime net shortwave radiation, thereby surface heat fluxes and Bowen ratio. The CTL experiment showed reasonable magnitudes and timing of air temperature at 2 m and 10 m; especially the small error in simulating minimum air temperature showed high potential for predicting frost and leaf wetness duration. The CTL experiment overestimated 10-m wind and precipitation, but the beginning and ending time of precipitation were well captured. 2) When the dynamic vegetation was turned on, the WRF/Noah-MP system showed more realistic values of leaf area index (LAI), net shortwave radiation, surface heat fluxes, Bowen ratio, air temperature, wind and precipitation. The DVG experiment, where LAI is a prognostic variable, produced larger LAI than CTL, and the larger LAI showed better agreement with the observed. The simulated Bowen ratio got closer to the observed ratio, indicating reasonable surface energy partition. The DVG experiment showed patterns similar to CTL, with differences for maximum air temperature. Both experiments showed faster rising of 10-m air temperature during the morning growth hours, presumably due to the rapid growth of daytime mixed layers in the Yonsei University (YSU) boundary layer scheme. The DVG experiment decreased errors in simulating 10-m wind and precipitation. 3) As horizontal resolution increases, the models did not show practical improvement in simulation performance for surface fluxes, air temperature, wind and precipitation, and required three-dimensional observation for more agricultural land spots as well as consistency in model topography and land cover data.

Control of Microorganisms in School Refectories and Kitchens Using Ozone Water and Ozone Gas (오존수 및 오존가스를 이용한 학교급식에서의 미생물 제어)

  • Choi, Jin-Kyung;Shin, Il-Shik;Kim, Dae Uk;Kim, Hee-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.586-592
    • /
    • 2015
  • This study was performed to determine optimum approaches for control of microorganisms in school refectories and kitchens. A reduction of more than 5.0 log CFU/mL was noted for Escherichia coli O157:H7, Salmonella Typhimurium, Listeria monocytogenes, Staphylococcus aureus, and Streptococcus mutans after treatment with 5 ppm ozone water for 60 s. Treatment of different vegetables with ozone water for 5 min showed bactericidal effects with 2-4 log reduction of viable cell number; the bactericidal effects differed according to the kinds of vegetables. The viable cell number on kitchen apparatus and tableware was not detected by ozone water treatment for 60 s. In addition, the count of the bacteria floating in the air in refectories and kitchens decreased 2.0 log CFU/1,000 L air to 0-1 CFU/1,000 L air on treatment with 45 ppm ozone gas for 12 hr. Therefore, ozone water and ozone gas may be good candidates as antimicrobial agents that can be used to improve sanitary conditions in school refectories and kitchens.

A study on the physico-chemical characteristics of municipal solid wastes generated in the sunchon city (순천시의 생활폐기물 발생량 예측 및 재활용시설의 용량산정에 관한 연구)

  • Hu, Kwan;Moon, Ok-Ran;Wang, Seung-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.4
    • /
    • pp.125-134
    • /
    • 2001
  • The purpose of this study is to provide basic information for a future countermeasure municipal and to establish several wastes policy after investigating solid wastes from Sunchon City. In addition, this research can be supported to manage of recycling plant and to reuse plant of each wastes. Results are as bellows after checking up and analysis type of waste in Sunchon city Unit solid waste generation rate from single family is $0.50kg/person{\cdot}day$, and total solid wastes are 41.9ton/day. Unit solid waste generation rate from apartments is $0.45kg/person{\cdot}day$, and solid wastes generation is 55.5ton/day. Unit solid waste generation rate from agricultural is $0.22kg/person{\cdot}day$ and total solid wastes are 13.5ton/day. That show total amount of municipal solid wastes from residential are 110.9ton/day. Unit solid waste generation rate from traditional markets is $1.85kg/person{\cdot}day$, and solid waste total volume is 5,400kg/day. Unit solid waste generation rate from small store is $2.03kg/person{\cdot}day$, and solid waste total are 25,101kg/day. Therefore, this show that total wastes are 30.50kg from downtown and commercial area. Solid waste quantity from Industrial area (Factory region) is 8.5ton and in case of school and hospitals are 7.2kg/day and 3.0kg/day. Solid waste amount from Institutional is 6.6kg/day. Food wastes were eliminated from municipal solid wastes as standard 63.4ton/day, and combustible wastes were 126.9ton/day. If it schedule about 5 years (by 2006) as durable year for food wastes treatment plant, it is expected 42.5ton/day for treatment capacity. We can judge that it is effective to be set 2 lines equipment ${\times}25ton/day$ as treatment ability under considering unexpected working condition such as any repair, trouble and an electrical load. If it schedule about 10 years (by 2011) as durable year for food wastes treatment plant, it is expected 150 ton/day for treatment capacity. We can conclude that it is effective to be set 2 lines equipment ${\times}80ton/day$ as treatment ability under considering working condition such as low loaded operating and the repair for incineration.

  • PDF

Evaluation of $^{14}C$ Behavior Characteristic in Reactor Coolant from Korean PWR NPP's (국내 경수로형 원자로 냉각재 중의 $^{14}C$ 거동 특성 평가)

  • Kang, Duk-Won;Yang, Yang-Hee;Park, Kyong-Rok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • This study has been focused on determining the chemical composition of $^{14}C$ - in terms of both organic and inorganic $^{14}C$ contents - in reactor coolant from 3 different PWR's reactor type. The purpose was to evaluate the characteristic of $^{14}C$ that can serve as a basis for reliable estimation of the environmental release at domestic PWR sites. $^{14}C$ is the most important nuclide in the inventory, since it contributes one of the main dose contributors in future release scenarios. The reason for this is its high mobility in the environment, biological availability and long half-life(5730yr). More recent studies - where a more detailed investigation of organic $^{14}C$ species believed to be formed in the coolant under reducing conditions have been made - show that the organic compounds not only are limited to hydrocarbons and CO. Possible organic compounds formed including formaldehyde, formic acid and acetic acid, etc. Under oxidizing conditions shows the oxidized carbon forms, possibly mainly carbon dioxide and bicarbonate forms. Measurements of organic and inorganic $^{14}C$ in various water systems were also performed. The $^{14}C$ inventory in the reactor water was found to be 3.1 GBq/kg in PWR of which less than 10% was in inorganic form. Generally, the $^{14}C$ activity in the water was divided equally between the gas- and water- phase. Even though organic $^{14}C$ compound shows that dominant species during the reactor operation, But during the releasing of $^{14}C$ from the plant stack, chemical forms of $^{14}C$ shows the different composition due to the operation conditions such as temperature, pH, volume control tank venting and shut down chemistry.

  • PDF

Effect of Root Zone Cooling Using the Air Duct on Temperatures and Growth of Paprika During Hot Temperature Period (공기순환 덕트를 이용한 근권부 냉방이 고온기 파프리카 재배에서 온도와 생육에 미치는 영향)

  • Choi, Ki Young;Jang, Eun Ji;Rhee, Han Cheol;Yeo, Kyung-Hwan;Choi, Eun Young;Kim, Il Seop;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.243-251
    • /
    • 2015
  • This study aimed to determine the effects of root zone cooling using air duct on air temperature distribution and root zone and leaf temperatures of sweet pepper (Capsicum annum L. 'Veyron') grown on coir substrate hydroponic system in a greenhouse. When the air duct was laid at the passage adjacent the slab, the direction of air blowing was upstream at $45^{\circ}$. The cooling temperature was set at $20^{\circ}C$ for day and $18^{\circ}C$ for night. For cooing timing treatments, the cooling air was applied at all day (All-day), only night time (5 p.m. to 1 a.m.; Night), or no cooling (Control). The air temperature inside the greenhouse at a height of 40 and 80cm above the floor, and substrate and leaf temperatures, fruit characteristics, and fruit ratio were measured. Under the All-day treatment, the air temperature was decreased about $4.4{\sim}5.1^{\circ}C$ at the height of 40cm and $2.1{\sim}3.1^{\circ}C$ at the height of 80cm. Under the Night treatment, the air temperature was decreased about $3.4{\sim}3.8^{\circ}C$ at the height of 40cm and $2.2{\sim}2.7^{\circ}C$ at the height of 80cm. The daily average temperature in the substrate was in the order of the Control ($27.7^{\circ}C$) > Night ($24.1^{\circ}C$) > All-day ($22.8^{\circ}C$) treatment. Cooling the passage with either upstream blowing at $45^{\circ}$ or horizontal blowing at $180^{\circ}$ was effective in lowering the air temperature at a height of 50cm; however, no difference at a height of 100cm. Cooling the passage with perpendicular direction at $90^{\circ}$ was effective in lowering the air temperature at the height between 100 and 200cm above the floor; however, no effect on the temperature at the height of 50cm. A greater decrease in leaf temperature was found at 7 p.m. than that at 9. a.m. under both All-day and Night treatments. Fresh weight partitioning of fruit was in the order of the All-day (48.6%) > Night (45.6%) > Control (24.4%) treatment. A higher fruit production was observed under the All-day treatment, in which the accumulated average temperature was the lowest, and it may have been led to a higher proportion of photosynthate distributed to fruit than other treatments.