• Title/Summary/Keyword: 가동온도

Search Result 233, Processing Time 0.033 seconds

A Study on the Ventilation Effects of the Shaft Development at a Local Limestone Mine (국내 석회석 광산 수갱 굴착에 의한 통기효과 분석 연구)

  • Lee, Changwoo;Nguyen, Van Duc;Kubuya, Kiro Rocky;Kim, Chang O
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.609-619
    • /
    • 2018
  • This study was carried out at a local limestone mine to analyze the ventilation efficiency of the shaft equipped with a main fan. The results show that its ventilation efficiency is clearly verified for the natural as well as the mechanical ventilation. The airflow rate of $11.7m^3/s$ was induced by the natural ventilation force and the maximum quantity is almost same as the airflow rate estimated by monitoring the average temperatures in the upcast and downcast air columns. Meanwhile, the airflow rate exhausted by the main fan through the shaft was $20.3{\sim}24.8m^3/s$; variation of the quantity was caused by the upward shift of the mine ventilation characteristic curve due to the frequent movement of the equipment. This indicates efforts are required to reduce the ventilation resistance and raise the quantity supplied by the main fan. The turbulent diffusion coefficients along the 1912 m long airway from the portal to the shaft bottom was estimated to be $15m^2/s$ and $18m^2/s$. Since these higher coefficients imply that contaminants will be dispersed at a faster velocity than the airflow, prompt exhaust method should be planned for the effective air quality control. The ventilation shaft and main fan are definitely what local limestone mines inevitably need for better working environment and sustainable development.

IoT Based Real-Time Indoor Air Quality Monitoring Platform for a Ventilation System (청정환기장치 최적제어를 위한 IoT 기반 실시간 공기질 모니터링 플랫폼 구현)

  • Uprety, Sudan Prasad;Kim, Yoosin
    • Journal of Internet Computing and Services
    • /
    • v.21 no.6
    • /
    • pp.95-104
    • /
    • 2020
  • In this paper, we propose the real time indoor air quality monitoring and controlling platform on cloud using IoT sensor data such as PM10, PM2.5, CO2, VOCs, temperature, and humidity which has direct or indirect impact to indoor air quality. The system is connected to air ventilator to manage and optimize the indoor air quality. The proposed system has three main parts; First, IoT data collection service to measure, and collect indoor air quality in real time from IoT sensor network, Second, Big data processing pipeline to process and store the collected data on cloud platform and Finally, Big data analysis and visualization service to give real time insight of indoor air quality on mobile and web application. For the implication of the proposed system, IoT sensor kits are installed on three different public day care center where the indoor pollution can cause serious impact to the health and education of growing kids. Analyzed results are visualized on mobile and web application. The impact of ventilation system to indoor air quality is tested statistically and the result shows the proper optimization of indoor air quality.

Assessment of DTVC Operation Efficiency for the Simulation of High Vacuum and Cryogenic Lunar Surface Environment (고진공 및 극저온 달의 지상 환경 재현을 위한 지반열진공챔버 운영 효율성 평가)

  • Jin, Hyunwoo;Chung, Taeil;Lee, Jangguen;Shin, Hyu-Soung;Ryu, Byung Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.125-134
    • /
    • 2022
  • The Global Expansion Roadmap published by the International Space Exploration Coordination Group, which is organized by space agencies around the world, presents future lunar exploration guidance and stresses a lunar habitat program to utilize lunar resources. The Moon attracts attention as an outpost for deep space exploration. Simulating lunar surface environments is required to evaluate the performances of various equipment for future lunar surface missions. In this paper, an experimental study was conducted to simulate high vacuum pressure and cryogenic temperature of the permanent shadow regions in the lunar south pole, which is a promising candidate for landing and outpost construction. The establishment of an efficient dirty thermal vacuum chamber (DTVC) operation process has never been presented. One-dimensional ground cooling tests were conducted with various vacuum pressures with the Korean Lunar Simulant type-1 (KLS-1) in DTVC. The most advantageous vacuum pressure was found to be 30-80 mbar, considering the cooling efficiency and equipment stability. However, peripheral cooling is also required to simulate a cryogenic for not sublimating ice in a high vacuum pressure. In this study, an efficient peripheral cooling operation process was proposed by applying the frost ratio concept.

Effects of Experimental Warming on Physiological Responses of Four Deciduous Tree Species Seedlings (실외 실험적 온난화 처리에 따른 활엽수 4개 수종 묘목의생리적 반응)

  • An, Jiae;Han, Seung Hyun;Chang, Hanna;Park, Min Ji;Son, Yowhan
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.4
    • /
    • pp.510-516
    • /
    • 2016
  • This study was conducted to investigate the physiological responses of newly-germinated seedlings of Fraxinus rhynchophylla Hance, Zelkova serrata (Thunb.) Makino, Betula costata Trautv. and Quercus variabilis Blume to open-field experimental warming. The seedlings in the warmed plots were warmed with $2.7^{\circ}C$ higher air temperature than those in the control plots using infrared heaters since April, 2015. Physiological responses (stomatal conductance, transpiration rate, chlorophyll content and net photosynthetic rate) to experimental warming varied with the species and the time of the measurement. Stomatal conductance ($mmol{\cdot}m^{-2}{\cdot}s^{-1}$) tended to decrease for F. rhynchophylla (Control: $158.97{\pm}42.76$; Warmed: $42.07{\pm}8.24$), Z. serrata (Control: $170.53{\pm}27.22$; Warmed: $101.17{\pm}42.27$) and B. costata (Control: $249.93{\pm}47.39$; Warmed: $150.73{\pm}26.52$). Transpiration rate ($mmol{\cdot}m^{-2}{\cdot}s^{-1}$) also decreased for F. rhynchophylla (Control: $4.08{\pm}0.62$; Warmed: $1.74{\pm}0.39$), Z. serrata (Control: $4.32{\pm}0.44$; Warmed: $3.24{\pm}1.14$) and B. costata (Control: $6.21{\pm}0.38$; Warmed: $4.66{\pm}0.28$). However, warming exhibited only minimal effects on stomatal conductance and transpiration rate of Q. variabilis seedlings. Chlorophyll content increased by the warming treatment while the effect of warming was not significant on net photosynthetic rate, since the warming treatment had a weak influence for changing net photosynthetic rate.

A Case Study of Software Architecture Design by Applying the Quality Attribute-Driven Design Method (품질속성 기반 설계방법을 적용한 소프트웨어 아키텍처 설계 사례연구)

  • Suh, Yong-Suk;Hong, Seok-Boong;Kim, Hyeon-Soo
    • The KIPS Transactions:PartD
    • /
    • v.14D no.1 s.111
    • /
    • pp.121-130
    • /
    • 2007
  • in a software development, the design or architecture prior to implementing the software is essential for the success. This paper presents a case that we successfully designed a software architecture of radiation monitoring system (RMS) for HANARO research reactor currently operating in KAERI by applying the quality attribute-driven design method which is modified from the attribute-driven design (ADD) introduced by Bass[1]. The quality attribute-driven design method consists of following procedures: eliciting functionality and quality requirements of system as architecture drivers, selecting tactics to satisfy the drivers, determining architectures based on the tactics, and implementing and validating the architectures. The availability, maintainability, and interchangeability were elicited as duality requirements, hot-standby dual servers and weak-coupled modulization were selected as tactics, and client-server structure and object-oriented data processing structure were determined at architectures for the RMS. The architecture was implemented using Adroit which is a commercial off-the-shelf software tool and was validated based on performing the function-oriented testing. We found that the design method in this paper is an efficient method for a project which has constraints such as low budget and short period of development time. The architecture will be reused for the development of other RMS in KAERI. Further works are necessary to quantitatively evaluate the architecture.

Clinical Experiences of Continuous Tepid Blood Cardioplegia; Valvular Heart Surgery (미온혈 심정지액의 임상적 고찰)

  • 이종국;박승일;조재민;원준호;박묘식
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 1999
  • Background: In cardiac surgery, hypothermia is associated with a number of major disadvantage, including its detrimental effects on enzymatic function, energy generation and cellular integrity. Warm cardioplegia with normothermic cardiopulmonary bypass cause three times more incidence of permanent neurologic deficits than the cold crystalloid cardioplegia with hypothermic cardiopulmonary bypass. Interruptions or inadequate distribution of warm cardioplegia may induce anaerobic metabolism and warm ischemic injury. To avoid these problems, tepid blood cardioplegia was recently introduced. Material and Method: To evaluate whether continuous tepid blood cardioplegia is beneficial in clinical practice during valvular surgery, we studied two groups of patients matched by numbers and clinical characteristics. Warm group(37$^{\circ}C$) consisted of 18 patients who underwent valvular surgery with continuous warm blood cardioplegia. Tepid group(32$^{\circ}C$) consisted of 17 patients who underwent valvular surgery with continuous tepid blood cardioplegia. Result: Heartbeat in 100% of the patients receiving continuous warm blood cardioplegia and 88.2% of the patients receiving continuous tepid blood cardioplegia converted to normal sinus rhythm spontaneously after removal of the aortic cross clamp. There were no differences between these two groups in CPB time, ACC time, the amount of crystalloid cardioplegia used and peak level of potassium. During the operation, the total amount of urine output was more in the warm group than the tepid group(2372${\pm}$243 ml versus 1535${\pm}$130 ml, p<0.01). There were no differences between the two groups in troponin T level measured 1hr and 12hrs after the operation. Conclusion: Continuous tepid blood cardioplegia is as safe and effective as continuous warm blood cardioplegia undergoing cardiac valve surgery in myocardial protection.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

The Analysis of Kinetic Parameters for BNR Process Simulation in Domestic Wastewater (국내하수에 적합한 BNR 공정 시뮬레이션을 위한 최적 동력학적 계수 산출)

  • Kim, Dae-Sung;Park, Myung-Gyun;Ahn, Ho-Chul;Ahn, Won-Sik;Lee, Eui-Sin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1385-1390
    • /
    • 2006
  • 외국에서 ASM 모델의 BNR 적용 연구결과를 국내 하수에 적용하기에는 하수농도, 온도, 슬러지농도 등이 국내와는 달라 적용상 무리가 있다. 본 연구에서 BNR 시뮬레이션을 위한 입력 자료로 활용되는 인자들은 IAWPRC task group에서 제안하는 값들을 사용하되 국내 하수성상에서 필요로 하는 인자들은 직접 실험을 통하여 부분적으로 구해냄으로써 모델 시뮬레이션의 신뢰도를 높이고자 하였다. F/M비의 변화량과 1/SRT과의 관계로부터, 종속영양미생물 생산계수 $Y_H$값을 구한결과, 0.40mg VSS/mg COD였다. 이것을 ASM No.2d에 적용하기 위하여 mg cell COD formed/mg COD oxidized 단위로 환산한 결과 0.58을 나타냈다. H 하수처리장의 1차 침전지 하수를 이용하여 호기성상태에서 OUR Test를 통한 미생물에 의한 유기물 섭취시 산소섭취율 변화를 측정하였다. 호기성상태와 무산소상태에서 구한 쉽게 분해되는 용존성유기물(Ss)값을 비교해보면 각각 35.5mg/L와 39.9mg/L로 약간의 차이는 있으나 유사한 값을 보여주고 있다. 시뮬레이션을 위한 동력학적 계수 중 무산소 상태에서 종속영양미생물의 ${\mu}_{max,H}$$3.56d^{-1}$로 나타났고, 호기성상태에서는 구하면 ${\mu}_{max,H}$$4.2d^{-1}$로 산출되었다. 종속영양미생물의 사멸계수 $b_H$를 구하기 위한 실험에서 초기 OUR의 10%이내가 될 때까지 걸린 시간은 7일정도가 걸렸으며, 사멸률 $b_H$$0.043hr^{-1}$로 나타났다. 독립영양미생물의 최대비성장률 ${\mu}_{max,A}$는 최대암모니아 섭취률을 이용하여 구한 결과 $0.65d^{-1}$로 나타났다.EX>$60%{\sim}87%$가 수심 10m 이내에 분포하였고, 녹조강과 남조강이 우점하는 하절기에는 5m 이내에 주로 분포하였다. 취수탑 지점의 수심이 연중 $25{\sim}35m$를 유지하는 H호의 경우 간헐식 폭기장치를 가동하는 기간은 물론 그 외 기간에도 취수구의 심도를 표층 10m 이하로 유지 할 경우 전체 조류 유입량을 60% 이상 저감할 수 있을 것으로 조사되었다.심볼 및 색채 디자인 등의 작업이 수반되어야 하며, 이들을 고려한 인터넷용 GIS기본도를 신규 제작한다. 상습침수지구와 관련된 각종 GIS데이타와 각 기관이 보유하고 있는 공공정보 가운데 공간정보와 연계되어야 하는 자료를 인터넷 GIS를 이용하여 효율적으로 관리하기 위해서는 단계별 구축전략이 필요하다. 따라서 본 논문에서는 인터넷 GIS를 이용하여 상습침수구역관련 정보를 검색, 처리 및 분석할 수 있는 상습침수 구역 종합정보화 시스템을 구축토록 하였다.N, 항목에서 보 상류가 높게 나타났으나, 철거되지 않은 검전보나 안양대교보에 비해 그 차이가 크지 않은 것으로 나타났다.의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전략이고, 이 전략의 유용성은 투자자가 설정한 투자기간보다 더욱 긴 분석기간의 주식가격정보에 의하여 최대한 발휘될 수 있음을 확인하였다.(M1), 무역적자의 폭, 산업의 생산

  • PDF

High-Resolution Numerical Simulations with WRF/Noah-MP in Cheongmicheon Farmland in Korea During the 2014 Special Observation Period (2014년 특별관측 기간 동안 청미천 농경지에서의 WRF/Noah-MP 고해상도 수치모의)

  • Song, Jiae;Lee, Seung-Jae;Kang, Minseok;Moon, Minkyu;Lee, Jung-Hoon;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.4
    • /
    • pp.384-398
    • /
    • 2015
  • In this paper, the high-resolution Weather Research and Forecasting/Noah-MultiParameterization (WRF/Noah-MP) modeling system is configured for the Cheongmicheon Farmland site in Korea (CFK), and its performance in land and atmospheric simulation is evaluated using the observed data at CFK during the 2014 special observation period (21 August-10 September). In order to explore the usefulness of turning on Noah-MP dynamic vegetation in midterm simulations of surface and atmospheric variables, two numerical experiments are conducted without dynamic vegetation and with dynamic vegetation (referred to as CTL and DVG experiments, respectively). The main results are as following. 1) CTL showed a tendency of overestimating daytime net shortwave radiation, thereby surface heat fluxes and Bowen ratio. The CTL experiment showed reasonable magnitudes and timing of air temperature at 2 m and 10 m; especially the small error in simulating minimum air temperature showed high potential for predicting frost and leaf wetness duration. The CTL experiment overestimated 10-m wind and precipitation, but the beginning and ending time of precipitation were well captured. 2) When the dynamic vegetation was turned on, the WRF/Noah-MP system showed more realistic values of leaf area index (LAI), net shortwave radiation, surface heat fluxes, Bowen ratio, air temperature, wind and precipitation. The DVG experiment, where LAI is a prognostic variable, produced larger LAI than CTL, and the larger LAI showed better agreement with the observed. The simulated Bowen ratio got closer to the observed ratio, indicating reasonable surface energy partition. The DVG experiment showed patterns similar to CTL, with differences for maximum air temperature. Both experiments showed faster rising of 10-m air temperature during the morning growth hours, presumably due to the rapid growth of daytime mixed layers in the Yonsei University (YSU) boundary layer scheme. The DVG experiment decreased errors in simulating 10-m wind and precipitation. 3) As horizontal resolution increases, the models did not show practical improvement in simulation performance for surface fluxes, air temperature, wind and precipitation, and required three-dimensional observation for more agricultural land spots as well as consistency in model topography and land cover data.