Development of an HVAC&R Systems Energy Evaluation Methodology and Simulation Program for Office Buildings (사무소 건물의 HVAC&R 시스템 에너지 분석방법 및 예측 프로그램 개발)

  • Cho, Jinkyun;Shin, Seungho;Kim, Jonghurn;Hwang, Dongkon;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.363-370
    • /
    • 2013
  • HVAC&R systems are the most energy consuming building services, representing approximately half of the final energy use in the building sector. Despite their significant energy use, there is a lack of a consistent and homogeneous framework to efficiently guide research. This research is about the energy consumptions of HVAC&R systems, with the aim of establishing a common idea for the analysis of building energy efficiency. Our approach deals with the concept of an HVAC&R set that is composed of subsystems. A matrix combination evaluation is examined, and a total of 960 sets can be implemented in a large scale office building. A method as a tool for energy evaluations of HVAC&R systems, and HEET as a energy simulation program, were developed.

A Study on the Operating Characteristics by Counter Flow and Parallel Flow in Separate Heat Pipe Exchanger (분리형 히트파이프식 열교환기에서 향류 및 병류유동에 따른 가동특성에 관한 연구)

  • 이기우;장기창;유성연
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • Separate heat pipe exchanger is considered as the high thermal transportation equipment, because evaporator and condenser are separately positioned in the long distance. Its characteristics are that the working fluid is circulated naturally by the position height of two exchangers. But the operating characteristics are restricted by the temperature of hot and cold fluid, flow pattern and diameter of vapor line, etc. in this study, the vapor pressure and the minimum height of two exchangers are studied about the factors restricting the operating characteristics.

  • PDF

An Effective Method of Diagnosis of Potato Leafroll Virus by RT-PCR (RT-PCR 방법을 이용한 효과적인 감자 잎말림 바이러스의 검정)

  • Jeon, Jae-Heung;Joung, Young-Hee;Choi, Kyung-Hwa;Kim, Hyun-Soon;Oh, Hyun-Woo;Park, Se-Won;Joung, Hyouk
    • Korean Journal Plant Pathology
    • /
    • v.12 no.3
    • /
    • pp.358-362
    • /
    • 1996
  • 감자 잎말림 바이러스를 검정하기 위하여 ELISA 및 전자현미경에 의해 바이러스 감염이 확인된 기내 배양중인 감장의 줄기로부터 RT-PCR 분석을 수행하였다. 분리된 총 RNA들로부터 바이러스 cDNA를 합성하고 감자 잎말림 바이러스 외피단백질의 일부인 465bp를 특이하게 증폭하도록 고안한 두 primer를 사용하여 PCR 반응을 하였다. 증폭된 465pb의 DNA 절편의 염기서열을 분석한 결과 역시 감자 잎말림 바이러스임을 확인하였다. 바이러스 검정에 있어서 EL-ISA 방법과 RT-PCR 방법간의 민감도를 조사한 결과 RT-PCR 방법간의 민감도를 조사한 결과 RT-PCR 방법이 ELISA 방법보다 감자 잎말림 바이러스검정에 있어서보다 정확한 방법인 것으로 사료된다.

  • PDF

Study on Angle Calculation of Two-axis Manipulator for Laser Assisted Machining (레이저 보조 가공을 위한 2-축 틸팅의 회전각에 대한 연구)

  • Kim, Dong Hong;Jung, Dong Won;Lee, Choon Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.2
    • /
    • pp.113-117
    • /
    • 2014
  • Laser Assisted Machining (LAM) was often used in process of difficulty-to-cut materials. In previous study, Laser assisted machining was a straight path processing using 1-axis manipulator in laser module. But 1-axis manipulator in laser module was able to process only straight path. So, in this study, laser module in laser assisted machining equipped to 2-axis manipulator. 2-axis manipulator has two motors. First motor is machining direction motor and second motor is Vertical Motor. Machining direction motor rotates in the direction of machining and vertical motor rotates vertical direction in the direction of machining. Machining path of laser assisted machining was considered diagonal path and curved path of laser heat source. This study calculated the 2-axis manipulator's rotation angle in diagonal path and curved path.

Cooling Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 냉방성능)

  • Park, Geun-Woo;Nam, Hyun-Ku;Kang, Byung-Chan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.471-476
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and c lose type heat pump system using effluent ground water was installed and tested for it church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000$ ton/day. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

A Case Series of Post-stroke Vision Disorders Using Korean Medical Treatment (뇌졸중 후 시야장애의 한의치료 증례집적연구)

  • Jung, Min-ho;Kim, Jae-hak;Kim, Se-won;Cho, Ki-ho;Mun, Sang-kwan;Jung, Woo-sang;Kwon, Seung-won
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.2
    • /
    • pp.217-223
    • /
    • 2018
  • In this study, five cases of post-stroke vision disorders are presented. The patients had no distinctive change in vision disorders before Korean medical treatment, which included herbal medicine, acupuncture, and electroacupuncture. After 11 to 28 days of Korean medical treatment, the patients experienced the first improvement of vision disorders after stroke. Also, patients who received Korean medical treatment after 30 days from onset, the duration in which the most improvement of post-stroke vision disorders occurs, progressed their vision disorders by the start of Korean medical treatment. Korean medical treatment might be effective in treating vision disorders after stroke.

A Study on Analysis of Mode I interlaminar Fracture Toughness of Foam Core Sandwich Structures (FOAM CORE SANDWICH 구조재의 Mode I 층간분리 파괴인성의 해석에 관한 연구)

  • Son, Se-Won;Gwon, Dong-An;Hong, Seong-Hui
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.81-86
    • /
    • 2000
  • This paper was carried out to investigate the characteristics of interlaminar fracture toughness of foam core sandwich structures under opening loading mode by using the double cantilever beam (DCB) specimens in Carbon/Epoxy and foam core composites. instead of using symmetric geometry of DCB specimen non-symmetric DCB specimen was used to calculate the interlaminar fracture toughness. Three approaches for calculating the energy release rate({{{{ {G }_{IC } }}}}) were compared. Fracture toughness of foam core sandwich structures by autoclave vacuum bagging and hotpress were compared and analyzed. Experiment nonlinear beam bending FEM method were performed. Suggested bonding surface compensation and equivalent area inertia moment was used to calculate the energy release rate in nonlinear analytical results. The conclusions among experimental nonlinear analytical and FEM results was observed. The vacuum bagging method was shown to be able to substitute method in stead of autoclave without serious loss of Mode I energy release rate({{{{ {G }_{IC }}}}}) to be able to substitute method in stead of autoclave without serious loss of Mode I energy release rate({{{{ {G }_{IC }}}}}).

  • PDF

The Effects of Cu TSV on the Thermal Conduction in 3D Stacked IC (3차원 적층 집적회로에서 구리 TSV가 열전달에 미치는 영향)

  • Ma, Junsung;Kim, Sarah Eunkyung;Kim, Sungdong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.3
    • /
    • pp.63-66
    • /
    • 2014
  • In this study, we investigated the effects of Cu TSV on the thermal management of 3D stacked IC. Combination of backside point-heating and IR microscopic measurement of the front-side temperature showed evolution of hot spots in thin Si wafers, implying 3D stacked IC is vulnerable to thermal interference between stacked layers. Cu TSV was found to be an effective heat path, resulting in larger high temperature area in TSV wafer than bare Si wafer, and could be used as an efficient thermal via in the thermal management of 3D stacked IC.

The Comparison of Weldability in Hybrid & Laser Welded Ship Structure A-grade Steel (조선용 A-grade 강재에 대한 하이브리드 및 레이저 용접부의 용접성 비교)

  • Oh, Chong-In;Park, Ho-Kyung;Jeong, Eun-Young;Rajesh, S.R;Bang, Han-Sur
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.193-196
    • /
    • 2006
  • Recently many research are going on in the field of application of Laser and Laser-Arc hybrid welding for superstructures such as ship-structures, transport vehicles etc. Therefore in this study an optimized welding condition and numerical simulation for hybrid welding by using previous numerical analysis which is used to calculate the heat source for Laser and Laser-Arc hybrid welding has been analyzed. For this purpose, fundamental welding phenomena of hybrid process(Laser+MIG) are determined based on the experiments. In order to calculate temperature and residual stress distribution in Laser and Laser-Arc hybrid welds, finite element heat source model is developed on the basis of experiment results and characteristics of temperature and residual stress distribution in Laser and Laser-Arc hybrid welds are understood from the result of simulation and found comparable to the experimental values.

  • PDF

A Study on Welding Distortion of Channel I Butt SA Weld using FE Analysis (유한요소해석을 이용한 Channel I butt SA 용접부 변형 해석에 관한 연구)

  • Shin, Dae-Hee;Shin, Sang-Beam;Lee, Joo-Sung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.189-192
    • /
    • 2006
  • The purpose of this study is to evaluate the welding distortion at the channel I butt SA weldment. In order to do it, the heat input model for the weldment was defined as combined heat source with the surface heat flux of gaussian mode and volume heat source uniformly distributed within weld groove on the basis of comparing the shapes of molten pool and temperature distribution obtained by FEA and experiment. The arc efficiency of SA welding for 2 dimensional FE analysis was determined as 0.85. The results of welding distortions at the weldment obtained by FEA and heat input conditions proposed have a good agreement with those obtained by experiment. Based on the results, it was suggested that the proper heat input model should be required to evaluate the welding distortion for weldment.

  • PDF