• Title/Summary/Keyword: {\gamma}$-ray

Search Result 1,836, Processing Time 0.028 seconds

An Interesting Story of Four Gamma-ray Bright AGNs by the iMOGABA

  • Lee, Sang-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.37.1-37.1
    • /
    • 2018
  • A Korean VLBI Network key science program, the Interferometric Monitoring of Gamma-ray Bright AGNs (iMOGABA) program continues to reveal the nature of the gamma-ray flares in active galactic nuclei (AGNs). Here in this presentation, we would like to introduce an interesting story about four gamma-ray bright AGNs - BL Lac, 1633+382, 3C 84, and M87 - based on the recent results of the iMGOABA. The results will include a) a sad story of an 'orphan' gamma-ray flare from BL Lac, b) a position offset of 40 pc for a gamma-ray flaring site from the radio regions in 1633+382, c) a position alignment of a gamma-ray flaring site with a central engine region in 3C 84, and d) a flat millimeter spectrum of a core in M87 revealed by the iMOGABA.

  • PDF

A Study of Gamma-ray Distribution around the $^{99}Mo-^{99m}TcO_4$ Generator ($^{99}Mo-^{99m}TcO_4$ Generator의 감마선량 분포에 관한 연구)

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.49-53
    • /
    • 2001
  • A number of radionuclides of interest in nuclear medicine are short lived isotopes that emit only gamma ray. The most of all Dept. of Nuclear Medicine in the hospt. are using the $^{99}Mo-^{99m}Tc$ generator for elution of the short lived isotope $^{99m}TcO_4$. A $^{99}Mo-^{99m}Tc$ generator consists of an alumina column on which $^{99}Mo$ is bound. The parent isotope($^{99}Mo$ : half life 67 hr.) decays to its daughter $^{99m}TcO_4^-$ which is a different element with a shorter half-life. $^{99}Mo$ emitted 41-keV(1.3%), 141-keV(5.6%) 181-keV(6.6%) and 366-keV(1.5%) gamma rays. But $^{99m}TcO_4$ emitted only 140-keV gamma ray. We study about the gamma ray distribution around the $^{99}Mo$ generator. And obtained the result as follows ; 1. Total counted gamma ray from generator smaller in front side than back. 2. The gamma ray emitted from $^{99}Mo$ generator without $^{99m}TcO_4$ vial increased in the back side(Mo column posited side) 3. The gamma ray only from the $^{99m}TcO_4$ vial increased in the front side. 4. Apron can protect gamma ray above 60% of total radiation from the $^{99}Mo$ generator.

  • PDF

Changes of the phsico-Chemical Characteristics of oils treated by the ${\gamma}$-ray irradiation (I) -The Extracted soybean oil- (방사선 조사선량에 따른 유지의 이화학적 성질변화 (I))

  • 임국이
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.4
    • /
    • pp.77-88
    • /
    • 1992
  • To investigate the oxidative stabilities of the ${\gamma}$-ray irradiated soybean during storage and heating and some physico-chemical characteristics of soybean and the extracted soybean oil (SBO) with/without the ${\gamma}$-ray irradiation were determined. The ${\gamma}$-ray level use in irradiation for soybean were 2.5, 5.0 and 10.0 KGY respectively and Acid Value, Peroxide Value, Conjugated Diene Value, Composed Fatty Acids amounts, and Trans Fatty Acid occurrence were determined for all samples, which were incubated at 45$\pm$1$^{\circ}C$ for 25 days heated at 180$\pm$1$^{\circ}C$ for 30 hours. And these values of the ${\gamma}$-ray treated samples were compared to those of nontreated samples. The results were obtained as follows : 1. According to the increased level of the ${\gamma}$-ray irradiation, there was little difference in Dielectric Constant, Viscosity, and the Induction Period by Rancimat. But, in case of 5.0 KGY, oxidative stability was increased more twice than that of non-irradiation. In the quantity of fatty Acids composition of the extracted soybean oil irradiated with 10.0 KGY, palmitic, oleic and linoleic acids were less increased thanb those of non-irradiation, while stearic, linolenic acids were decreased. In the case of 2.5 KGY irradiation, stearic and oleic acids were increased. 2. The Acid Value of SBO according to the ${\gamma}$-ray irradiation level was almost not change, but was 0.1 lower than that of non-irradiation during incubation (45$\pm$1$^{\circ}C$). The Peroxide Value of SBO with the ${\gamma}$-ray irradiation, was very lower than that of non-irradiation, but its effect on oxidative stability was better of SBO treated with 5.0 KGY and 10.0 KGY. In the Fatty Acids composition of SBO, palmitic, stearic, oleic acids were increased, while linoleic, linolenic acids were decreased during incubation(45$\pm$1$^{\circ}C$). This tendency was more obvious due to the ${\gamma}$-ray level. While heating(180$\pm$1$^{\circ}C$), the Acid Value of SBO treated with the ${\gamma}$-ray irradiation was decreased, the Acid Value of SBO irradiated with 2.5 KGY was the lowest. Also the peroxide Values of SBO treated with 5.0 KGY, 10.0 KGY were very lower than that of non-irradiation. Conjugated Diene Value of SBO was almost unchanged according to the ${\gamma}$-level and heating time. 3. When the methyl linoleate was irradiated with the ${\gamma}$-ray, the Trans Fatty Acid was little produced. In case of SBO with non-irradiation, the trans C18:1 was occured about 6.5~7.9%, but trans C18:2 and C18:3 were not shown, while SBO irradiated with the ${\gamma}$-ray 2.5, 5.0, 10.0 KGY, trans C18:3 and C18:2 amount in SBO were increased according to heating time, but trans C18:3 was little occured. As these results, the effects of the ${\gamma}$-ray irradiation to oil containing food were to cut down the energy for food storage and to increase oxdative stability during storge. And also it was shown to be the best that 10.0 KGY of the ${\gamma}$-ray irradiation would be applied to soybean.

  • PDF

Comparison of Irradiation Effect of Different Radiation Types on Decontamination of Microorganisms in Red Pepper Powder (고춧가루 오염 미생물의 제어에서 방사선종별 조사 효과)

  • Park, Kyung-Sook
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2014
  • This study investigated the reduction of microbial population and sensory properties in red pepper powders irradiated by gamma ray, electron beam, and X-ray. Populations of total aerobic bacteria and yeast & molds in red pepper powders were decreased by irradiation treatment in a dose-dependent manner. Gamma ray, electron beam, and X-ray at doses above 8 kGy caused 100% inhibition on growth of aerobic bacteria in red pepper powders. Inhibitory activity of X-ray on sterilization of red pepper powders was significantly equal to or higher compared to gamma ray and electron beam. Color and off flavor in red pepper powders were no significant difference among the control and samples irradiated with gamma ray, electron beam, and X-ray. As a result, the gamma ray, electron beam, and X-ray irradiation can be used to sterilize the microbial growth in red pepper powders without quality loss.

A GOLDEN DECADE OF GAMMA-RAY PULSAR ASTRONOMY

  • Hui, Chung-Yue
    • Journal of The Korean Astronomical Society
    • /
    • v.51 no.6
    • /
    • pp.171-183
    • /
    • 2018
  • To celebrate the tenth anniversary since the launch of Fermi Gamma-ray Space Telescope, we take a retrospect to a series of breakthroughs Fermi has contributed to pulsar astronomy in the last decade. Apart from significantly enlarging the population of ${\gamma}$-ray pulsars, observations with the Large Area Telescope onboard Fermi also show the population is not homogeneous. Instead, many classes and sub-classes have been revealed. In this paper, we will review the properties of different types of ${\gamma}$-ray pulsars, including radio-quiet ${\gamma}$-ray pulsars, millisecond pulsars, ${\gamma}$-ray binaries. Also, we will discuss the prospects of pulsar astronomy in the high energy regime.

Study of the Radioactive Source Detection and the Visualization with the Stereo Radiation Detector (스테레오 기반 감마선원 탐지 및 가시화에 관한 연구)

  • Park, Gang-teak;Lee, Nam-ho;Cha, Han-ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1100-1102
    • /
    • 2015
  • In the study, stereo-based of gamma-ray sources detector for the space including the gamma-ray source to scan in a raster scan method, and obtains a visible light image and the gamma-ray image. We went to retrieve and visualize the distance to source and the direction of the 3-dimension information from Stereo gamma-ray detectors. Configuration of the detector consisted of gamma-ray detecting sensor for gamma-ray Sources, pan-tilt for the scanning of the raster for detecting sources, and CCD camera for visible-light image. Implement a stereo structure of the device to measure the spatial distribution of source, the gamma-ray Detector and CCD camera for the stereo image acquisition was as each configuration 2. The gamma-ray detector and a visible light camera to revision the distribution of detection source, After performing each of the cameras of the stereo correction and shows the distribution of the gamma-ray Sources through 중첩 visible light image and the gamma-ray image. After Rectification process of Left and right image, we were derived visualization results of the stereo image.

  • PDF

Effect of Electron Beam and ${\gamma}$-Ray Irradiation on the Curing of Epoxy Resin

  • Kang, Phil-Hyun;Park, Jong-Seok;Nho, Young-Chang
    • Macromolecular Research
    • /
    • v.10 no.6
    • /
    • pp.332-338
    • /
    • 2002
  • The effect of an electron beam and ${\gamma}$-ray irradiation on the curing of epoxy resins was investigated. Diglycidyl ether of bisphenol A (DGEBA) and diglycidyl ether of bisphenol F (DGEBF) as epoxy resin were used. The epoxy resins containing 1.0-3.() wt% of triarylsulphonium hexafluoroantimonate(TASHFA) and triarylsulphonium hexafluorophosphate(TASHFP) as initiator were irradiated under nitrogen at room temperature with different dosage of EB and ${\gamma}$-rays from a Co$^{60}$ u source. The chemical and mechanical characteristics of irradiated epoxy resins were compared after curing of EB and ${\gamma}$-ray irradiation. The thermal properties of cured epoxy were investigated using dynamic mechanical thermal analysis. The chemical structures of cured epoxy were characterized using near infrared spectroscopy. Mechanical properties such as flexural strength, modulus were measured. The gel fraction of DGEBA with ${\gamma}$-ray was higher than that of the epoxy with EB at the same dose. Young's modulus of the sample irradiated by ${\gamma}$-ray is higher than that of sample cured by EB. From the result of strain at yield, it was found that the epoxy cured by ${\gamma}$-ray had a higher stiff property compared with the irradiated by EB.

Assays of Residual Antibiotics after Treatment of γ-ray and UV Irradiation (감마선과 UV 조사에 의한 항생제 분해)

  • Shin, Ji-Hye;Nam, Ji-Hyun;Yu, Seungho;Lee, Myunjoo;Lee, Dong-Hun
    • Journal of Radiation Industry
    • /
    • v.4 no.1
    • /
    • pp.39-45
    • /
    • 2010
  • The pollution of antibiotics is a major cause of spreading antibiotics resistant bacteria in the environment. Applications of ozonation, UV, and ${\gamma}-ray$ irradiations have been introduced to remove antibiotics in the effluents from wastewater treatment system. In this study, we compared the chemical (HPLC) and biological (antimicrobial susceptibility test, AMS) assays in measuring of the concentrations of residual antibiotics after ${\gamma}-ray$ and UV irradiation. Most samples were degraded by ${\gamma}-ray$ irradiation (1~2 kGy). However, lincomycin and tetracycline were not degraded by UV irradiation. The concentration of residual antibiotics, that was treated with ${\gamma}-ray$ and UV irradiation, measuring by bioassay was similar to HPLC. The concentrations of ${\gamma}-ray$ irradiated cephradine measured by AMS test were 2 times higher than that of HPLC assay, indicating AMS test is more sensitive than HPLC assay. These results indicate that ${\gamma}-ray$ irradiation technique is more useful than UV irradiation, and biological assay is more useful to detect the antibiotics and toxic intermediates in antibiotics degradation.

Bentonite based ceramic materials from a perspective of gamma-ray shielding: Preparation, characterization and performance evaluation

  • Asal, Sinan;Erenturk, Sema Akyil;Haciyakupoglu, Sevilay
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1634-1641
    • /
    • 2021
  • Exposure to gamma-rays is hazardous for humans and other living beings because of their high penetration through the materials. For this reason, shielding materials (usually lead, copper and stainless steel) are used to protect against gamma rays. This study's objective was to prepare ceramic materials for gamma radiation shielding by using different natural bentonite clays. Gamma-ray attenuation performances of the prepared shielding materials at different thicknesses were investigated and evaluated for different gamma-ray energies from different standard point gamma radiation sources (251Am, 57Co, 137Cs, 60Co, and 88Y). The mass and linear attenuation coefficients of the prepared ceramics vary between 0.238 and 0.443 cm2 g-1 and between 0.479 and 1.06 cm-1, respectively, depending on their thicknesses. Results showed that these materials could be prioritized because of their evidential properties of gamma radiation protection in radiation applications.

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.