• Title/Summary/Keyword: [p, q]-order

Search Result 517, Processing Time 0.031 seconds

Optimum Design of Axial-Flow Fans Including Noise Parameters (소음파라메터를 고려한 축류송풍기의 최적설계)

  • Son, B.J.;Lee, S.H.;Yoon, S.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.1-12
    • /
    • 1995
  • In order to seek various relationships among many design parameters employed in the design of the axial-flow fans the program which generates acoustic spectrum has been developed and its validity verified. Outputs of the program, with other outputs from a formerly developed performance prediction program, have been used to form a multi-objective function, for which an optimal design process was carried out. The present analysis shows that overall noise level and efficiency has contrasting trends, and the chord length turns out to be the most critical design variable. In the chosen design case of requirements $Q=2000m^2/min$, ${\Delta}P_s=67mmAq$, D=1.4m, the chord length of 0.2059m minimizes the overall noise level, while chord length of 0.1254m maximizes the efficiency. The resulting chord length in the balanced optimization is 0.1809m.

  • PDF

An Enhanced PCC Harmonic Voltage Mitigation and Reactive Power Sharing in Islanded Microgrid

  • Pham, Minh-Duc;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.138-140
    • /
    • 2018
  • Parallel distributed generators (DGs) in the islanded microgrid are generally operated autonomously by means of the droop control scheme. However, the traditional droop control methods which use the P-${\omega}$ and Q-E curve to share power between DGs are still concerned to improve the accuracy of reactive power sharing. Moreover, the uncontrolled harmonic power reduces the point of common coupling (PCC) voltage quality and microgrid stability. In order to solve these problems, this paper proposes an enhanced PCC harmonic control strategy and an improved reactive power sharing control scheme. Based on the low bandwidth communications, a secondary control is implemented with both central controller and local controller. The effectiveness of the proposed control scheme is analyzed through the simulation.

  • PDF

The New Load Flow Algorithm using Optimal Programming (최적화기법을 이용한 새로운 조류계산 알고리즘)

  • Jeon, Dong-Hoon;Kim, Kern-Joong;Choi, Jang-Hum;Eom, Jae-Sun;Huh, Hyung;Rhee, Byoung-Ill
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.11
    • /
    • pp.542-548
    • /
    • 2000
  • In this paper, we proposed a new load flow analysis algorithm. In order to develop it, we converted typical power flow problem into optimal problem. This problem has the objective function that minimize the difference between calculated values and specified values of bus powers and subject to bus power equations of P and Q. Using it, we solved the divergence by singularity of Jacobian matrix, the divergence by initial value in the typical power flow study. In the study of a sample system, we verified the superiority of proposed algorithm.

  • PDF

A Study on Finding of Simplified Multiple Load Flow Solutions and Evaluating of Voltage Stability (간략조류계산법과 전압안정도 평가예 관한 연구)

  • Song, Kil-Young;Kim, Sae-Young
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.556-558
    • /
    • 1995
  • This paper presents a new simplified method for finding the multiple load flow solutions and through their solutions the voltage stability can be evaluated. Line flow($P_{ij}$, $Q_{ij}$) may be formulated with the second-order equations for $V_{i}^{2}$ in polar coordinates or two circle equations for $e_{i}$ and $f_{i}$ in rectangular coordinates. Based on this feature, multiple load flow solutions are calculated with simple works, results of multiple load flow solutions are used for sensitivity analysis of voltage stability. Also, in the case that reactive power sources is considered, method of evaluating the voltage stability is introduced. The proposed method was validated to 2-bus and IEEE 6-bus system.

  • PDF

Development of a meshless finite mixture (MFM) method

  • Cheng, J.Q.;Lee, H.P.;Li, Hua
    • Structural Engineering and Mechanics
    • /
    • v.17 no.5
    • /
    • pp.671-690
    • /
    • 2004
  • A meshless method with novel variation of point collocation by finite mixture approximation is developed in this paper, termed the meshless finite mixture (MFM) method. It is based on the finite mixture theorem and consists of two or more existing meshless techniques for exploitation of their respective merits for the numerical solution of partial differential boundary value (PDBV) problems. In this representation, the classical reproducing kernel particle and differential quadrature techniques are mixed in a point collocation framework. The least-square method is used to optimize the value of the weight coefficient to construct the final finite mixture approximation with higher accuracy and numerical stability. In order to validate the developed MFM method, several one- and two-dimensional PDBV problems are studied with different mixed boundary conditions. From the numerical results, it is observed that the optimized MFM weight coefficient can improve significantly the numerical stability and accuracy of the newly developed MFM method for the various PDBV problems.

Low-cost Single-Phase HAIf-bridge Active Power Filter with One Current Sensor (단일 전류센서를 갖는 저가의 단상 반브릿지 APF)

  • 김길동;신정렬;이우동;박현준;김희중
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.3
    • /
    • pp.173-179
    • /
    • 2004
  • This paper describes a low-cost single-phase active power filter, which consists of a half-bridge PWM inverter with a simple control circuit. In order to verify the performance of proposed active power filter, many computer simulations with EMTP codes and experimental works with a hardware prototype were done. Both results confirm that the proposed active power filter shows excellent performance to eliminate the harmonics generated in the single-phase non-linear load. The active power filter has advantage of low implementation cost and compact size, using a half-bridge inverter and a simple control circuit with only one current sensor. So, it can be fabricated as a plug-in type. This paper shows the necessity and a good possibility to apply such advantage to the electric railway system.

Morphological Variability of the Japanese Swimming Charybdis japonica Populations (해양 갑각류 민꽃게(Charybdis japonica) 집단의 형태학적 변이성)

  • Heo, Youn-Seong;Lee, Bok-Kyu;Huh, Man-Kyu
    • Journal of Life Science
    • /
    • v.16 no.4
    • /
    • pp.672-675
    • /
    • 2006
  • In order to determine the morphological variations of the Japanese swimming crab, Charybdis japonica, we conducted morphological analysis of five populations that are relatively abundant in Korea and Japan. Abdominal sternite for individuals of the Tean population showed significantly short when compared to those of other populations. Principal component analysis demonstrated that morphological differentiation was due to differences (A/Q, B/M, D/P, F/O, J/K), and effectively discriminated each others. The first two components accounted for 40.9% and 60.7% of the variation, respectively. The dendrogram showed three distinct groups, Tokyo population, Taean population, and the other populations.

Electronic Structures and Physical Properties of the Ordered and Disordered $Ni_2$MnGa Alloy Films

  • Kim, K. W.;Lee, N. N.;Y. Y. Kudryavtsev;Lee, Y. P.
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.104-106
    • /
    • 2003
  • In this study, the electronic structures and physical properties of Ni$_2$MnGa alloy films and their dependence on the order-disorder structural transitions were investigated. The results show that the ordered films behave nearly the same as the bulk $Ni_2$MnGa alloy, including the martensitic transformation at 200 K. Unexpectedly, the disordering in $Ni_2$MnGa alloy films does not lead to any appreciable magnetic ordering down to 4 K. An annealing of the disordered films restores the ordered structure with an almost full recovery of the magnetic and the transport properties of the ordered $Ni_2$MnGa alloy films. A possible explanation of the disappearance of magnetic moment in the disordered film is given by using the ab initio first-principles electronic-structure calculations.

Enhanced Reactive Power Sharing and Voltage Restoration in Islanded Microgrid

  • Pham, Minh-Duc;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.47-48
    • /
    • 2016
  • Parallel distributed generators (DGs) in the islanded micro-grid are normally controlled with the aid of the droop control scheme. However, the traditional droop control methods which use the P-${\omega}$ and Q-E curve to share power between DGs are still concerned to improve the accurate of reactive power sharing and variation of frequency and voltage at the point of common coupling (PCC). This paper proposes a control scheme to solve the limitation of microgrid in islanded operation such as reactive power sharing accuracy and PCC voltage and frequency restoring. In order to achieve the control objective, a secondary control is implemented with both central controller and local controller by using the low bandwidth communications. The effectiveness of the proposed control scheme is analyzed through the simulation.

  • PDF

The ouput impedance control strategy for UPS with wirless parallel opertaion (UPS 시스템의 무선 병렬 운전을 위한 출력 임피던스 제어 기법)

  • Kim, Jeong-Woo;Han, Sanghun;Koo, Tae-Guen;Choe, Gyu-Ha;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.19-20
    • /
    • 2016
  • This study deals with the control method of the output impedance for the UPS(Uninterruptible Power Supply) system's wireless parallel opertaion. In order to avoid using any communication between modules, the P/Q droop method was applied. The experiment result based on NPC(Neutral Point Clamped) inverters is included.

  • PDF