An Experimental Study on the Prediction Method of Light Weight Floor Impact Sound Insulation Performance of Apartment Floor Structures through Mini-Laboratory Tests (축소실험실을 이용한 바닥완충구조의 경량충격음 차음성능 예측방법에 관한 실험적 연구)

  • 송민정;장길수;김선우
    • Journal of KSNVE
    • /
    • v.10 no.1
    • /
    • pp.82-96
    • /
    • 2000
  • The purpose of this study is to figure out the relationship between the mini-laboratory and the reverberation room for the domestic floor structures which are practically constructed in apartment houses. For this purpose, seven specimen which were varied in structures and thicknesses were tested in Chonnam National University reverberation room and in the artificial mini-laboratory which is the $\farc{1}{3}$ scale model of the former. From the result of this study, it was proved that there is a good correlation between the mini-laboratory and the reverberation room for the apartment floor structures as well as floorcovering PVC. The result of this study could save the labor and the time, etc.

  • PDF

A Study on the Noise Characteristics of House Range Hoods (주택 주방후드의 소음특성에 관한 연구)

  • Kim, Jin-Ki;Sohn, Jang-Yeul;Cho, Chang-Geun;Shin, Il-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.355-358
    • /
    • 2005
  • This study aims at comparing the noise characteristics of conventional and functional hood. Measurement and analysis was carried out in anechoic room and actual environment. In case of anechoic room, intensity and sound pressure level were measured. In case of actual environment sound pressure level under different apartment size and distances. Sound pressure level of actual environment was higher than that of anechoic room. It is concluded that noise characteristics were different from each other in case of anechoic room and actual environment.

  • PDF

A Study on the Estimation of Composite Noise in Clean room (클린룸에서 FFU의 합성소음 예측에 관한 연구)

  • Lee, Hyun-Nam;Hong, Dong-Pyo;Cho, Sang-Jun;Moon, In-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.231-235
    • /
    • 2005
  • Recently, some semiconductor and LCD manufacturers require equipment suppliers to serve the data of composite noise for clean room. In this study, we evaluate the composite noise of clean room by numerically and experimentally. The value of experimental result is more higher than calculated one as much as 1$\sim$2dB(A).

  • PDF

Experimental Study on Vertical Reduction Effectiveness of Main Control Room of NPP using 3-Dimensional Isolation System (원전 주제어실 삼차원 면진시스템 수직방향 저감효과 시험연구)

  • Ham, Kyung-Won;Lee, Kyung-Jin;Suh, Yong-Pyo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.417-423
    • /
    • 2006
  • The seismic characteristics with 3-Dimensional isolation systems have been studied using a shaking table system. In this study, we made nuclear power plant main control room floor systems and several seismic shaking table tests with and without isolation systems were conducted to evaluate floor isolation effectiveness. Isolation systems have showed large reduction effectiveness in acceleration and response spectra with x and z direction respectively, but horizontal isolation is more effective than vertical one It is required to make isolation systems of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such isolation systems, it is recommended that much consideration should be taken into account when applied to main control room of NPP.

  • PDF

Analysis of Airflows in a Room with Panoramic PIV (파노라마-PIV를 이용한 실내기류 해석)

  • Hwang Tae-Gyu;Doh Deog-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1154-1160
    • /
    • 2005
  • A panoramic-PIV system has been constructed for the analysis of the airflows in a room. Smoke is used as seeding particles and are visualized by a pulsed laser (Nd-Yag, 120 mJ). Panoramic images have been obtained by an image composition process using the two images obtained by the two cameras $(1k\times1k)$ that are viewing the wide measurement areas. Velocity vector fields have been obtained by the grey-level cross-correlation PIV method. Three room models $(L{\times}W{\times}H[mm^3],\;500\times500\times250,\;350\times350\times175,\;250\times250\times125)$ have been tested. The experimental results have proven that the constructed panoramic-PIV system can be used as a useful tool for analyzing the airflow characteristics in the room models.

A Study of Hybrid Ventilation System applying to an Apartment House (공동주택용 하이브리드 환기설비에 관한 연구)

  • Yi, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1137-1143
    • /
    • 2006
  • The purpose of this research lays on examining the adequacy of the hybrid ventilation system. The hybrid ventilation system must satisfy the next to be used. Firstly, the cold-draft phenomenon must not exist in the occupied zone. Secondly, the condensation must not happen on the surfaces of vents. Thirdly, the flow of make-up air must be happened in an each space by exhausted air of a rest room and living room. We used an examination and CFD method to verify these. Trough the examination of air-vents, We confirmed that the cold-draft to be induced by make-up air does not happen and could not find the condensation in the limits of outdoor temperature higher than 265K. Through CFD simulation, We confirmed that the rapid temperature change existed only within 0.5m the occupied zone and the flow of air was happened in an each space by only exhausted air in the rest room and living room. Consequently, the hybrid system is possible method to an apartment house.

  • PDF

A Study on a Heat-load of IT Equipments for the Thermal Environment Control in the Data Center (데이터센터의 합리적인 환경제어를 위한 장비 발열기준에 대한 연구)

  • Cho, Jin-Kyun;Hong, Min-Ho;Jeong, Cha-Su;Kim, Byung-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.938-943
    • /
    • 2006
  • The primary purpose of a computer room of data center and associated infrastructure is to support the operation of critical IT equipment. Traditionally, most owners of large critical data centers have been more than willing to accept a reasonable amount of computer room worker discomfort if necessary to support critical IT systems. All electrical equipment produces heat, which must be removed to prevent the equipment temperature from rising to an unacceptable level. Most information technology equipment and other equipment found in a data center or network room is air-cooled. Sizing a cooling system requires an understanding of the amount of heat produced by the equipment contained in the enclosed space, along with the heat produced by the other heat sources typically encountered.

  • PDF

Room-temperature Magnetotransport in Degenerately Doped GaAs:(Mn,Be) by Virtue of the Embedded Ferromagnetic Clusters

  • Yu, Fu-Cheng;Kim, Do-Jin;Kim, Hyo-Jin;Ihm, Young-Eon
    • Journal of Magnetics
    • /
    • v.10 no.3
    • /
    • pp.103-107
    • /
    • 2005
  • Magnetotransport is a prerequisite to realization of electronic operation of spintronic devices and it would be more useful if realized at room temperature. The effects of Be codoping on GaMnAs on magnetotransport were investigated. Mn flux was varied for growth of precipitated GaMnAs layers under a Be flux for degenerate doping via low-temperature molecular beam epitaxy. Magnetotransport as well as ferromagnetism at room temperature were realized in the precipitated GaAs:(Mn,Be) layers. Codoping of Be was shown to promote formation of MnGa clusters, and annealing process further stabilized the cluster phases. The room-temperature magnetic properties of the layers originate from the ferromagnetic clusters of MnGa and MnAs embedded in GaAs. The degenerately doped metallic GaAs matrix allowed the visualization of the magnetotransport through anomalous Hall effect.

Architectural Improvement plans in a quarantine system for Senior facilities (노인요양시설 방역을 위한 시설 개선 방안)

  • Kang, Jeeeun;Kwon, Soonjung;Lee, Hyunjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.3
    • /
    • pp.61-69
    • /
    • 2021
  • Purpose: Senior long-term care facilities are vulnerable to a cluster infection because of frequent physical contact, large group dining, communal living, and room sharing. This study aims to provide architectural improvement plans for a quarantine system in the facilities. Methods: Actual quarantine action data, guidelines from governments and institutes, in-depth interviews with facility staff are analyzed. Results: To prevent a cluster infection in the senior facilities, it is necessary to provide an architectural plan focusing on increasing the number of single rooms and isolation rooms, providing isolation rooms for staff, separation of a soiled room from a clean room, planing an entry vestibule and a visitor's room. Implications: It is important to analyze the existing condition of facilities that had been going through cohort isolation and provide the architectural solution to strengthen infection control.

ROOM TEMPERATURE FERROMAGNETISM IN TRANSITION METAL DOPED OXIDE SEMICONDUCTORS, $TiO_2$ and ZnO

  • Y. H. Jeong;S-J. Han;Park, J.H.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.17-17
    • /
    • 2003
  • Semiconductors with ferromagnetism at room temperature has been actively searched for in recent years; a prospect of devices using both charge and spin continuously gives impetus to the activities. Transition metal doped oxide materials have been of particular interest. Co substituted ZnO [1] and TiO$_2$ [2] thin films, for example, were reported to show ferromagnetic properties at room temperature. However, various studies do not seem to converge on a definite picture [3,4,5]. The issue is rather fundamental: whether a system shows ferromagnetic properties at all, and in case it does, whether the system possesses a close coupling between magnetism and transport properties. In this talk, we shall assess the current status of transition metal doped oxide materials as room temperature ferromagnetic semiconductors.