A Study on Safety by Risk Assessment of Clean Room (Clean Room 위험성 평가에 따른 안전성 확보에 관한 연구)

  • Song Yun-Suk;Yoon Myong-O;Hyun Seong-Ho;Lee Chang-Woo;Yoon Yo-Song;Kim Sung-Min
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.78-85
    • /
    • 2004
  • This research analyzes Clean Room accidents, and presents research Clean Room, major fire prevention standards of Clean Room (FM, IRI, and NFPA Code), various results from Fire Simulation of analysis. The results are : the smoke diffusion is very quick coupled with the Heating, Ventilating, and Air Conditioning (HVAC) systems under fire ; the possibility of getting the result and the possibility the role of the Sprinkler systems to reduce the diffusion of the smoke. We learn about the importance to stop operating Heating, Ventilating, and Air Conditioning (HVAC) systems and to operate the Sprinkler system for securing safety with fire detection. Therefore, This research will be contributing to secure safety of Clean Room.

A study on the residential Consciousness of their own room - A study on Children's Space from a Welfare Viewpoint ( II ) - (아동의 주거 및 아동실에 대한 인식 - 시설복지적 측면에서 본 아동공간에 관한 연구 ( II ) -)

  • 박인전
    • Journal of the Korean housing association
    • /
    • v.5 no.1
    • /
    • pp.47-57
    • /
    • 1994
  • The purposes of this study are to serve s$ the bsaic data for the guidance and the dffective preparation of children's room and the children's residing environment in addition, by grasping generally the residential consciousness of children and the consciousness of children's room. For these purposes, the data were collected by using questionnare distributed to 214 5th grade elemantary school children living in Taegu. The data were analyzed using frequency, perecntile, anova, duncan's test, regression analysis. The major findings of this research are as follow: 1. It was found that many children wanted to have their own room because they are quiently able to study without being disturbed in their study. And it is shown that they were generally satisfied with the their own room. 2. There were significant differences in the consciousness of their own room according to the independent variables such as mother's age, father's job, the numbers of room. 3. The residential consciousness of children was variable according to father's age, mother's employment, the order of birth, income, the conditions of housing possession, parent's educational level, housing style, the numbers of room. 4. The mother's employment, father's educational level, the conditions of housing possession, the numbers of room, family numbers were significantly related to the evaluation of their own room. 5. Among the domains of the evaluation of their own room. the degree of width and the degree of convenience were variable to have influence on the satisfaction of their own room

  • PDF

A Study on the Indoor Air Pollution of Singing Room and PC Room (노래방과 컴퓨터 게임방 내의 실내공기오염에 관한 연구)

  • 이주상;원정일;이철민;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.67-74
    • /
    • 2002
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. Since most people spend a large majority of their time indoors, indoor air may affect human health more than outdoor air. This outline survey was carried out to investigate the extent of indoor air pollution in singing room and PC room. The concentrations of major indoor air pollutants(carbon dioxide, total suspended particulate, airborne microbes) and Thermocircumstance(temperature, relative humidity, intensity of illumination) were observed from October 1 to 31, 2001. As results of the survey, the mom values of thermocircumstance in singing room and PC room were $22.1^{\circ}C$ of temperature, 37.1% of humidity, 75 Lux of intensity of illumination and $22.0^{\circ}C$ of temperature, 52.6% of humidity, 135 Lux of intensity of illumination, respectively. The mean concentrations of carbon dioxide were 1589 ppm in singing room and 615 ppm in PC room, respectively The concentrations of carbon dioxide in singing room were higher than the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs. The mean concentrations of total suspended particulate were $0.33{\;}mg/\textrm{m}^3$ in singing room and $0.57{\;}mg/\textrm{m}^3$ in PC room respectively. The mean concentrations of airborne microbe were $16{\;}CFU/\textrm{m}^3$ in singing room and $12{\;}CFU/\textrm{m}^3$ in PC room, respectively.

Analysis of Core Interventions of Operating Room using Nursing Intervention Classification (NIC간호중재분류체계를 이용한 수술실 핵심간호중재분석)

  • Lee, Yoon-Young;Park, Kwang-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.3
    • /
    • pp.361-372
    • /
    • 2002
  • Purpose : The purpose of study was to identify to analysis of core nursing interventions performed by Operating Room nurses. Method : The subjects of the study were arbitrarily selected nurses(n=104) working in Operating Room. The period for data collection was 15 days from July, 15, 2002 to July, 30. 2002. The instrument for study was 486 Nursing Interventions Classification developed by McClosky & Bulechek(2000) and was translated into Korean. In 486 nursing interventions, 57 nursing interventions were selected by more than half of 47 professional nurses group of Operating Room. 57 nursing interventions were used as a secondary questionnaire. In the secondary questionnaire, labels and definitions of all 57 interventions were listed. The collected data were self reported by Operating Room nurses. The data were analysed with SPSS program. Result : In 57 nursing interventions, the 'Behavior' domain was the most frequently used. Core interventions of Operating Room were performed several times a day by more than 50% of Operating Room nurses. Core interventions of Operating Room were 16 Core interventions, 7 classes, 5 domains. In the core interventions, the 'Physiological:Complex' domain was the most frequently used. Core interventions of Operating Room were Surgical Preperation, Infection Control:Intraoperative, Surgical Precautions, Fall Prevention, Documentation, Surgical Assistance, Environmental Management:Safety, Skin Surveillance, Physical Restraint, Pressure Ulcer Prevention, Environmental Management:Comfort, Infection Protection, Presence, Emotional Support, Specimen Management, Shift Report. Conclusion : Core interventions of Operating Room have implications for nursing care practice, nursing education, nursing research, and nursing information system in Operating Room.

  • PDF

A Study on the Architectural Planning for Improvement of the Healing Environment in Multi-bed Room of General Hospitals (종합병원 다인병실의 치유환경 개선을 위한 건축 계획적 연구)

  • 김용우;양내원
    • Korean Institute of Interior Design Journal
    • /
    • no.36
    • /
    • pp.76-83
    • /
    • 2003
  • The purpose of this study is to know how to improve environment of multi-bed room by investigating and analysing factors influencing to patients. 1 measured stress and satisfaction degrees about patient room for 4ㆍ5ㆍ6ㆍ7 men of domestic general hospital wards. The results of research show that patients of 4 bed room appeared the fewest stress and highest satisfaction degree among patients of other room styles. The patients positioned between two beds can give us more stress and fewer satisfaction than others. These results have proven that 4 bed room patients are offering comfortable environment than any other room types as a healing environment. When patient room area are more than 7.3$M^2$ per 1 person, bed interval space is more than 120cm, there is curtain between bed, transit space such as a toilet were established in patient room, patients' satisfaction appeared high.

Investigation of the Environment for Conservation in the Facilities of Exhibition and Collection for Cultural Properties (문화재 전시 및 수장시설 내에서의 보존환경 조사연구)

  • Hong, Jung-Ki;Kim, Sa-Dug;Kim, Soon-Kwan;Kang, Dai-Ill;Lee, Myeong-Hui
    • 보존과학연구
    • /
    • s.22
    • /
    • pp.155-171
    • /
    • 2001
  • The facilities of exhibition and collection for cultural properties is affected by environmental pollution. In order to accumulate a store of basic data, we was investigated eight points(three points at exhibition room and five points at collection room) at four institutes, from December 2000 to March 2001.As a result of investigation, the temperature of A-Exhibition room measured low because of don’t moved HVAC(Heating, Ventilation and Air-Conditioning) System, B Exhibition room is dry for the effect of air-conditioner and the air pollutants concentration of C-Exhibition room is high for the kind of an exhibition room. The air-condition was varied within the open period. The air pollutants concentration of A-Collection room is measured high because the air-pollutants is generated in a new buildings and the air pollutants concentration of C-1 & C-2-Collection room is high for the kind of an collection room. It is necessary to ventilate sufficiently.

  • PDF

Space Usage and User Needs of Postpartum Care Centers (산후관리시설의 사용실태 및 사용자 요구에 관한 연구)

  • Son Yeo-Rym;Hwang Yeon-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.5 s.52
    • /
    • pp.18-25
    • /
    • 2005
  • This study examined the current space usage of postpartum care center and postpartum mother's assessment of postpartum care center. This study was conducted questionnaire web survey. 220 women who used postpartum care center were surveyed. The data were analyzed by using SPSS Program for Win 12.0. Frequency, percentage, mean were used. The major findings were as follows: The postpartum care center was consisted of 5 areas such as living area, sanitary area, public area, service area and administration area. Living and public area were mainly occupied, but service area was insufficient. The users showed high satisfaction with mother room, and low satisfaction with nursing room and shower room. The users complained of size of mother room, collaboration with others in shower room and toilet. The users wanted guest meeting room for users' privacy of living room. The users wanted service area such as massage room, fitness room, physical care roon.

A TENTATIVE PLAN ON AN ARRANGEMENT AND A MODEL OF UNIVERSITY LIBRARY BUILDING (대학도서관건립(大學図書館建立)에 있어서 배치(配置)와 모형(模型)에 관(関)한 시안(試案) -특(特)히 "J대학" 제(第) 2 도서관(図書館)을 중심(中心)으로-)

  • Choe, Jung-Tai
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.5 no.1
    • /
    • pp.165-184
    • /
    • 1981
  • This study is concerned with a tentative plan on an arrangement and a model of university library building which is the 2nd (branch) library of J. National University in North Jeonla province. At first, it is necessary to have built new library building for undergraduate student in J. National University. Secondary, I studied on the site problems, a model, size and an arrangement planning in this campus. Finally, at least, to install modernized facilities for this library have to require as follows: 1. General Reading Room 2. Reference Room 3. Basic Reading Room 4. Free Reading Room 5. Reserved Room 6. Periodical Room 7. Seminar and Group Study Room 8. Brousing Room 9. Smoking Room 10. Display Hall.

  • PDF

An Investigation of the Noise in Ship Engine-Room and Cabins for Hearing Protection (I) (청력보호를 위한 선박 기관실 및 선실소음의 조사(I))

  • Yu, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.97-103
    • /
    • 1999
  • As the noise of ship engine room is too loud, the engineer who works in a ship engine-room has the trouble of hearing. In this paper deals the investigation of the noise of ship engine room and cabins with the internationally allowable noise exposure level and noise exposure time. Recently, the problem of engine-room noise is more serious because of shipowner wants to make small number and larger size of cylinder. Therefore, engineers work in a ship engine-room for a long time have the trouble of hearing when they are exposed the high noise level. In this study, two kinds of vessels were used to investigate the noise of engine room, engine-control room, bridge, offices and cabins. As criteria of sound levels, A-weighted sound pressure level and octave band pressure level were used.

  • PDF

A study on the Room Acoustic Renovation of Music Room at Daihyun Elementary School in Yongin (초등학교 음악실의 실내음향 개선에 대한 연구 - 대현초등학교 사례를 중심으로 -)

  • Choi, Won-Gab;Shin, Jic-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.13 no.1
    • /
    • pp.17-25
    • /
    • 2006
  • Elementary school classroom designs have been developed toward open education system to provide students diverse and improved educational environments since the early of 1990 in Korea. Unfortunately, the quality of music room has not still shown dramatic improvements due to the lack of the acoustical knowledges of architects. This report aims to investigate typical acoustic quality of previous or current music room of elementary schools and show new acoustic treatment technologies to improve the room acoustic of music room by adapting composite perforated panel system and diffusion technology. The music room at Daihyun Elementary school in Yongin was chosen as a case study of this report. The music room was measured to be analyzed using field measurements and the acoustical specifications of composite perforated panel systems and kinds of diffusors were set. Acoustic measurements were performed after the renovation to show the differences between previous room acoustic and after the acoustic renovations. As the result, the case study has shown that the new composite perforated panel systems and diffusion surfaces lowered reverberation time at proper level along with improving the clarity of music, RASTI, and spatial impressions. Also, acoustic interferences such as comb filtering and flutter echoes have been controlled dramatically by diffusive surfaces. The study shows music rooms in elementary schools, middle and high schools can be improved by adapting composite perforated panel systems and diffusors.