• 제목/요약/키워드: 'PASS'

검색결과 5,361건 처리시간 0.033초

Design of Ultra-wide Band-pass Filter Based on Metamaterials Applicable to Microwave Photonics

  • Lee, Chongmin;Shim, Wooseok;Moon, Yong;Seo, Chulhun
    • Journal of the Optical Society of Korea
    • /
    • 제16권3호
    • /
    • pp.288-291
    • /
    • 2012
  • We designed an ultra-wide band-pass filter applicable to microwave reflectometry for KSTAR (Korea Superconducting Tokamak Advanced Research) and to microwave photonics. The proposed ultra-wide band-pass filter exhibits a metamaterial structure characterized by a wide band, low insertion loss, and high skirt selectivity. The proposed filter is applied to enhance the linearity of reflectometry at the output of a VCO (voltage controlled oscillator). The pass-band of the proposed filter is observed at 18~28 GHz, and the out-of-band rejection is below 20 dB. Further, we constructed an unwrapped negative phase of S(2, 1) to verify the characteristics of the metamaterial. The under- and upper-band at lower limits of the pass-band are left- and right-handed, respectively. The group delay of the filter is less than 0.5 ns.

DFT 기반 페이저 연산 시 새로운 저역통과필터를 이용한 고주파 노이즈 경감 방법 (High Frequency Noise Reduction Method Using a Newly Designed Low-pass Filter in DFT-Based Phasor Estimation)

  • 백민우;강상희
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.898-904
    • /
    • 2017
  • DFT(Discrete Fourier Transform) is one of the most widely used method to estimate the phasor of a relaying signal. The harmonics are eliminated by the DFT. However, high frequency components, except for harmonics, are not removed and cause an error in DFT-based phasor estimation process. This paper suggests high frequency noise reduction method by using a newly designed low-pass filter to estimate a signal phasor. When selecting a stop-band cut-off frequency of the low-pass filter, high frequency components generated by faults are considered. To reduce the phasor estimation delay caused by a low-pass filter, this paper proposes a low-pass filter whose settling time is reduced. An adverse effect of high frequency noise on DFT-based phasor estimation is reduced. To evaluate the performance of the proposed method, signals which are collected under a fault condition at a 345[kV] transmission system modeled by EMTP-RV are used.

제주시 정수장 처리수의 급수과정별 수질변화 특성 (Water Quality Change Characteristics of Treated Water in Distribution System of Water Treatment Plant of Jeiu City)

  • 한경용;이민규;정호진;감상규
    • 한국환경과학회지
    • /
    • 제16권1호
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of $NO_3^-$ and $Cl^-$ of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and $CHCl_3$ that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.

요금소 하이패스 차로 배치 최적화를 위한 하이패스 차량 교통분산율 추정 (Estimation of Hi-pass Traffic Dispersion Rates to Determine The Optimal Location of Hi-pass Lanes at A Toll Plaza)

  • 이재수;이기영;이철기;윤일수;유정훈
    • 한국ITS학회 논문지
    • /
    • 제12권4호
    • /
    • pp.22-32
    • /
    • 2013
  • 고속도로 이용차량중 통행료 전자지불장치인 하이패스를 장착한 차량의 비율이 급속도로 증가하고 있는 상황에서, 요금소 하이패스 차로 배치의 최적화는 교통제어와 운영측면에서 매우 중요하다. 본 연구에서는 영업소별 물리적 기하구조 형태와 교통 특성을 고려하여 현재의 하이패스차로 설치 위치의 적정성을 분석하였다. 이를 위해 하이패스 차로별로 차량이 균등하게 배분되어 이용하는가를 측정하기 위해 "하이패스차량 교통분산율"이라는 새로운 평가지표를 개발하였다. 또한 교통분산율에 영향을 주는 변수들을 도출하여 이러한 변수들과 교통분산율과의 관계를 로지스틱회귀모형을 이용하여 추정하였다. 모형추정결과에 따르면 하이패스 교통량, 광장부 길이, 진입연결로와의 거리, 진출연결로와의 거리, 중앙 배치비율, 우측배치비율 등의 변수들이 교통분산율에 영향을 주는 것으로 파악되었으며, 이중에서 하이패스 차로배치 위치 변수인 중앙 배치비율, 우측 배치비율을 조정함으로서 교통분산율을 개선할 수 있는 것으로 밝혀졌다. 본 연구를 통해 하이패스차로 배치의 적정성을 판단할 수 있는 교통분산율을 계량화할 수 있게 되어 하이패스차로 위치 선정과 운영방식을 최적화할 수 있을 것으로 기대된다.

방사성동위원소 심조영술상 심전도게이트 일회통과법을 이용한 우심실 박출계수 (Right Ventricular Ejection Fraction using ECG-Gated First Pass Cardioangiography)

  • 문영희;이해규;이성용;박석민;정수교;임정익;박용휘;신경섭;김영균;권순석
    • 대한핵의학회지
    • /
    • 제27권1호
    • /
    • pp.135-139
    • /
    • 1993
  • Radionuclide cardioangiography has been widely applied and has played major roles in non-invasive assessment of cardiac function. Three techniques, first-pass, gated first and gated equilibrium methods, have commonly been used to evaluate right ventricular ejection fraction which usually abnormal in the patients with cardiopulmonary disease. It has been known that the gated first pass method is the most accurate method among the three techniques in assessment of right ventricular ejection fraction. The radionuclide right ventricular ejection fraction values were determined in 13 normal subjects and in 15 patients with chronic obstructive pulmonary disease by the gated first pass method and compared with those of the first pass method because there ha,j been no published data of right ventricular ejection fraction by the gated first pass method in Korea. The values of right ventricular ejection fraction by the gated first pass method were compared with the detas from the pulmonary function test performed in the patients with chronic obstructive pulmomary disease. The results were as follows: 1) The values of right ventricular ejection fraction by the gated first pass method were $50.1{\pm}6.1%$ in normal subjects and $38.5{\pm}8.5$ in the patients with chronic obstructive pulmonary disease. There was statistically significant difference between the right ventricular ejection fraction of each of the two groups (p < 0.05). 2) The right ventricular ejection fraction by the gated first pass method was not linearly correlated with $FEV_1$, VC, DLCO, and FVC as well as $P_aO_2$ and $P_aCO_2$ of the patients with chronic obstructive pulmonary disease. We concluded that right ventricular ejection fraction by the gated first pass method using radionuclide cardioangiography may be useful in clinical assessment of the right ventricular function.

  • PDF

고역통과필터를 이용한 혈관조영상의 화질 개선 (Improvement of Angiogram Quality Using by High Pass Filter)

  • 박민주;이상복
    • 한국방사선학회논문지
    • /
    • 제8권6호
    • /
    • pp.301-307
    • /
    • 2014
  • 본 연구에서는 DSA 장치에 의하여 획득된 영상을 고역 통과 필터링 알고리즘을 구성하여 구성된 알고리즘으로 실험을 하여 혈관조영상의 화질을 개선하는 방안을 제안하였다. 고역 통과 필터(High Pass Filter)는 고주파 성분은 통과시키고 저주파 성분은 차단하는 필터이다. 의료영상에서 고주파 성분은 장기(organ)의 윤곽이나 경계선 부분이 고주파 성분에 해당된다. 따라서 고역 통과 필터는 경계선 검출에도 쓰이지만 고역 강조를 위해서도 이용된다. 제시한 알고리즘으로 분석을 하여 혈관조영상의 화질을 개선할 수 있었다. 목적부위의 표현이 확연하게 두드러짐을 알 수 있었다. 제안된 방안을 이용한다면 DSA 시스템의 화질을 개선하는 소프트웨어에 적용하여 오진을 줄여주고 시술의 정확도를 더욱 높여 줄 수 있을 것이라 사료된다.

LC공진기와 DGS구조를 이용한 5.8GHz에서 저지대역을 갖는 소형 초광대역 대역통과 여파기 (Ultra-Wideband Band-Pass Filter with Notched Band at 5.8GHz using the LC Resonators and DGS)

  • 정승백;양승인
    • 대한전자공학회논문지TC
    • /
    • 제47권8호
    • /
    • pp.68-73
    • /
    • 2010
  • 본 논문에서는 LC공진기를 이용하여 5.8GHz 대역에서 저지대역을 형성하는 초광대역 대역통과 여파기를 제안한다. 통과대역 이후 대역에서 높은 대역차단 특성을 얻고 여파기의 크기가 증가되는 것을 막기 위해 DGS(Defected Ground Structure) 구조를 사용하였다. 또한 LC공진기는 매우 작은 크기의 스터브와 라디얼 스터브로 설계되어 제안하는 여파기를 매우 작은 크기로 제작할 수 있다. 측정결과 전체 통과 대역은 2.21GHz~10.92GHz 이고 삽입손실은 최대 0.5dB, 반사손실은 최소 16dB, 군지연 변화폭은 0.29ns였으며 5.2GHz~6.2GHz 의 저지대역을 형성하였다.

광대역의 저지대역을 갖는 부채꼴 형태의 개방형 스터브를 이용한 저역통과 여파기 (A Low-pass Filter with Wide-stop Band Using Radial-shaped Open Stub)

  • 윤기철;김성철
    • 한국정보통신학회논문지
    • /
    • 제20권7호
    • /
    • pp.1237-1242
    • /
    • 2016
  • 본 논문은 병렬 결합선로(coupled-line)와 부채꼴(radial) 개방형 스터브(stub)를 이용한 고조파가 억압된 저역통과 여파기에 대해 제안을 한다. 본 제안한 저역통과 여파기의 특징은 병렬 결합선로의 구조 때문에 고조파가 광대역으로 억압되었다는 결과를 얻을 수 있었다. 저역통과 여파기의 개방형 스터브는 부채꼴로 구성되어 있으며 이는 여파기의 크기를 조절 할 수 있다. 제안한 저역통과 여파기의 크기는 $6.98{\times}7.60mm2$이며 차단 주파수는 2.45 GHz 이다. 분포정수소자(distributed element)로 구성되어 있어 단가면에서 경제적이고 제작이 쉬우며 대량 생산이 가능한 이점이 있다. 또한 광대역 고조파 억압에 대한 대역폭은 128 %이며 여파기의 삽입 및 반사 손실은 각각 1.07 dB 및 19.5 dB를 얻었다.

롤 포밍 공정에서의 롤 패스의 수에 따른 스프링 백 영향 연구 (A Study of Spring-back Effect According to the Number of Roll Passes in the Roll Forming Process)

  • 김동홍;장애;정동원
    • 한국기계가공학회지
    • /
    • 제15권1호
    • /
    • pp.42-49
    • /
    • 2016
  • This study was analyed V-bending in order to analyze the spring-back phenomenon in the roll forming process. The material of forming sheet used in the roll forming process is high tension steel and the product name of sheet material is POSTEN 60. The most important variable is the number of roll passes (3-Pass, 4-Pass, 5-Pass, 6-Pass and 10-Pass) and other roll forming process variables were fixed. To determine the characteristics of the tension and compression, the forming sheet was analyzed by dividing the layer (Upper and Bottom) in the thickness direction from the center line. The results of FEM simulation analysis was derived to von-mises stress equivalent strain, and the spring-back value was calculated according to the final forming shape. The more number of the roll pass, von-mises stress and equivalent strain value of forming sheet were lowed. Also, spring-back values tended to decrease. The results of this study can be utilized for prediction and trend of spring-back value in the roll forming process applied to high tension steel sheet. So, development time and cost of the roll forming process is expected to be reduced.

용접상세의 변화에 따른 용접이음부의 잔류응력에 관한 연구 (A Study on the Residual Stress in the Welded Joints with Different Details)

  • 임청권;박문호
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.709-720
    • /
    • 1998
  • 용접잔류응력의 모재두께방향을 포함하는 3차원 분포를 파악하기 위해, 용접상세를 변화시킨 필렛용접이음을 대상으로 해서 실험 및 해석을 수행하였다. 특히, 지금까지 계측이 곤란했던 필렛용접이음의 용접루트부의 잔류응력을 실측하였다. 파라메타로써는 용접입열량과 용접층수를 취급하고, 모재두께방향을 포함하는 3차원 잔류응력의 분포를 조사하였다. 그 결과, 입열량이 증가하면, 용접토우와 루트부를 포함하는 용접부에서는 잔류응력의 크기에 변화가 거의 없지만, 인장잔류응력의 영역이 크게 나타났다. 또 단층과 다층용접의 비교에서는, 다층용접 쪽이 단층용접보다 잔류응력이 상당히 낮음을 알 수 있었다. 용접부 근방의 인장잔류응력의 영역도 다층용접 쪽이 단층용접보다 작게 나타난 것을 알 수 있었다.

  • PDF