• Title/Summary/Keyword: σ

Search Result 198, Processing Time 0.029 seconds

Environmental Geochemical Characteristics of the Acid Mine Drainage and Stream Sediments in the Abandoned Honam Coal Mine Area, Korea (호남탄전지역 폐탄광의 산성광산배수와 하상퇴적물의 환경지구화학적 특성)

  • Park, Young-Seog;Kim, Jong-Kyun;Kim, Jin;Jang, Woo-Seog;Lee, Ki-Hyung;Han, Min-Su
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.241-255
    • /
    • 2002
  • The purpose of this study is to investigate environmental geochemical characteristics for the acid mine drainage and stream sediments in the abandoned Honam coal mine area. For the chemical analysis, stream winter samples were collected at 54 sites and for the mineralogical and chemical analysis, stream sediments samples were collected at 34 sites. Physical and chemical characteristics of stream water were measured at the site and chemical compositions were analyzed by ICP-AES, ICP-MS and IC. Mineralogical characteristics of stream sediments samples were determined using XRD, SEM and EDS. In physical and chemical properties, stream water shows thats pH 2.85~8.12, Eh -62~215 mV, EC 0.205~146 ms/m, ER 0.234~255 {$\Omega}{\cdot}$m, DO 0.03~1068 mg/L and TDS 10.96~1420mg/L. In chemical compositions, we obtain that K 0.118~3.184 mg/L, Mg 2.1~114.48 mg/L, Ca 2.59~l25.02 mg/L, Al 0.01~44.72 mg/L, Fe 0.108~89.49 mg/L and Na 5.45~125.41 mg/L. Stream sediments are commonly composed of quartz, illite and goethite in the result of x-ray diffraction. After heat treatment at 98$0^{\circ}C$, the hematite peaks are distinctly shown. In consideration of heavy metals (include Fe) for steam sediments, Fe ranges 22575~34713 ppm, Zn 41.66~970.3 ppm, Cd 0.52~52.07 ppm, Cu 1.25~198.5 ppm and Pb 0.43~77.35 ppm.

Inorganic-organic nano-hybrid; Preparation of Nano-sized TiO$_2$ Paste Trapped OMC Nano-emulsion and it's Application for Cosmetics (OMC Nano-emulsion을 포집하고 있는 Nano-TiO$_2$-Paste의 합성과 화장품의 응용)

  • Byung Gyu, Park;Jong Heon, Kim;Jin Hee, Im;Kyoung Chul, Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.181-187
    • /
    • 2004
  • Preparations of mesoporous materials using various templates and their applicability have been intensively investigated for many years. We studied on synthesizing mesoporous Ti02 with pores in which sensitive compounds having weak physico-chemical properties such as thermal or UV irradiation and low solubility in solvent are trapped. Prior to trapping OMC in the pores of mesoporous titania, OMC was nano-emulsified in O/W system using Lecithin. Thereafter the OMC was trapped in the pores of mesoporous titania using sol-gel method. Main focus of this work is to prepare OMC-trapped mesoporous titania and to trace the stability and solubility of nano-emulsified OMC in the pores of mesoporous titania, and compared with that of mesoporous silica. OMC-trapped mesoporous Inorganic-Organic hybrid titania showed higher factors in sun protecting and a skin penetration phenomenon was reduced.

The Monitoring on Plasticizers and Heavy Metals in Teabags (침출용 티백 포장재의 안전성에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Kang, Kil-Jin;Jeon, Dae-Hoon;Kim, Hyung-Il;Sung, Jun-Hyun;Choi, Hee-Jung;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.231-237
    • /
    • 2006
  • Nowadays the teabag is worldwide used for various products including green tea, tea, coffee, etc. since it is convenient for use. In case of outer packaging printed, however, there is a possibility that the plasticizers which is used for improvement in adhesiveness of printing ink may shift to inner tea bag. In this study, in order to monitor residual levels of plasticizers in teabags, we have established the simultaneous analysis method of 9 phthalates and 7 adipates plasticizers using gas chromatography (GC). These compounds were also confirmed using gas chromatography-mass spectrometry (GC-MSD). The recoveries of plasticizers analyzed by GC ranged from 82.7% to 104.6% with coefficient of variation of $0.6\sim2.7%$ and the correlation coefficients of each plasticizer was $0.9991\sim0.9999$. Therefore this simultaneous analysis method was showed excellent reproducibility and linearity. And limit of detection (LOD) and limit of quantitation (LOQ) on individual plasticizer were $0.1\sim3.5\;ppm\;and\;0.3\sim11.5\;ppm$ respectively. When 143 commercial products of teabag were monitored, no plasticizers analysed were detected in filter of teabag products. The migration into $95^{\circ}C$ water as food was also examined and the 16 plasticizers are not detected. In addition we carried out analysis of heavy metals, lead (Pb), cadmium (Cd), arsenic (As) and aluminum (Al) in teabag filters using ICP/AES. $Trace\sim23{\mu}g$ Pb per teabag and $0.6\sim1718{\mu}g$ Al per teabag were detected in materials of samples and Cd and As are detected less than LOQ (0.05 ppm). The migration levels of Pb and Al from teabag filter to $95^{\circ}C$ water were upto $11.5{\mu}g\;and\;20.8{\mu}g$ per teabag, respectively and Cd and As were not detected in exudate water of all samples. Collectively, these results suggest that there is no safety concern from using teabag filter.

Effect of an Acrylic Plate and SSD on Dose Profile and Depth Dose Distribution of 9 MeV Electron Beams (에너지 저하체로서 아크릴과 SSD 가 9MeV 전자선의 측방 및 깊이선량분포에 미치는 효과)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.65-71
    • /
    • 1998
  • The aims are to evaluate the effects of an 1.0 cm acrylic plate and SSD on the dose profile and depth dose distribution of 9 MeV electron beam and to analyse adequacy for using an acrylic plate to reduce energy of electron beams. An acrylic plate of 1.0 cm thickness was used to reduce energy of 9 MeV electron beam to 7 MeV. The plate was put on an electron applicator at 65.4 cm distance from x-ray target. The size of the applicator was 10${\times}$l0cm at 100 cm SSD. For 100cm, l05cm and 110cm SSD, depth dose on beam axis and dose profiles at d$\_$max/ on two principal axes were measured using a 3D water phantom. From depth dose distributions, d$\_$max/, d$\_$85/, d$\_$50/ and R$\_$p/, surface dose, and mean energy and peak energy at surface were compared. From dose profiles flatness, penumbra width and actual field size were compared. For comparison, 9 MeV electron beams were measured. Surface dose of 7 MeV electron beams was changed from 85.5% to 82.2% increasing SSD from 100 cm to 110 cm, and except for dose buildup region, depth dose distributions were independent of SSD. Flatness of 7 MeV ranged from 4.7% to 10.4% increasing SSD, comparing 1.4% to 3.5% for 9 MeV. Penumbra width of 7 MeV ranged from 1.52 cm to 3.03 cm, comparing 1.14 cm to 1.63 cm for 9 MeV. Actual field size increased from 10.75 cm to 12.85 cm with SSD, comparing 10.32 cm to 11.46 cm for 9 MeV. Virtual SSD's of 7 and 9 MeV were respectively 49.8 cm and 88.5cm. In using energy reducer in electron therapy, depth dose distribution were independent of SSD except for buildup region as well as open field. In case of using energy reducer, increasing SSD made flatness to deteriorate more severely, penumbra width more wide, field size to increase more rapidly and virtual SSD more short comparing with original electron beam. In conclusion, it is desirable to use no energy reducer for electron beam, especially for long SSD.

  • PDF

ATM Cell Encipherment Method using Rijndael Algorithm in Physical Layer (Rijndael 알고리즘을 이용한 물리 계층 ATM 셀 보안 기법)

  • Im Sung-Yeal;Chung Ki-Dong
    • The KIPS Transactions:PartC
    • /
    • v.13C no.1 s.104
    • /
    • pp.83-94
    • /
    • 2006
  • This paper describes ATM cell encipherment method using Rijndael Algorithm adopted as an AES(Advanced Encryption Standard) by NIST in 2001. ISO 9160 describes the requirement of physical layer data processing in encryption/decryption. For the description of ATM cell encipherment method, we implemented ATM data encipherment equipment which satisfies the requirements of ISO 9160, and verified the encipherment/decipherment processing at ATM STM-1 rate(155.52Mbps). The DES algorithm can process data in the block size of 64 bits and its key length is 64 bits, but the Rijndael algorithm can process data in the block size of 128 bits and the key length of 128, 192, or 256 bits selectively. So it is more flexible in high bit rate data processing and stronger in encription strength than DES. For tile real time encryption of high bit rate data stream. Rijndael algorithm was implemented in FPGA in this experiment. The boundary of serial UNI cell was detected by the CRC method, and in the case of user data cell the payload of 48 octets (384 bits) is converted in parallel and transferred to 3 Rijndael encipherment module in the block size of 128 bits individually. After completion of encryption, the header stored in buffer is attached to the enciphered payload and retransmitted in the format of cell. At the receiving end, the boundary of ceil is detected by the CRC method and the payload type is decided. n the payload type is the user data cell, the payload of the cell is transferred to the 3-Rijndael decryption module in the block sire of 128 bits for decryption of data. And in the case of maintenance cell, the payload is extracted without decryption processing.

The Analysis of Forest Vegetation in Mt. Kumjeong (금정산(金井山) 일대(-帶)의 삼림식생분석(森林植生分析))

  • Yun, Chung Weon;Bae, Kwan Ho;Hong, Sung Cheon
    • Current Research on Agriculture and Life Sciences
    • /
    • v.13
    • /
    • pp.31-44
    • /
    • 1995
  • Mt. Kumjeong is located in south-eastern part of the Korean Peninsular($129^{\circ}$01' to $129^{\circ}$05' E, $35^{\circ}$03' to $35^{\circ}$17' N) and the altitude of the summit is 802 meter. In order to find out the vegetation units which made it possible to classify subtropical forest and south-temperate forest, Mt. Kumjeong (which is located in a border of between subtropical forest and south-temperate forest) was selected as a study area. The primary result of actual vegetation analysis in Mt. Kumjeong based upon the vegetation community analysis methods by the ZM-school, and the relationships between vegetation community and two parameters(altitude, topography) analyzed by using coincidence analysis method were summarized as followings. 1. Based upon analytic methods of the vegetation community by the ZM-schools, the primary analytic result of the analysis of vegetation community in Mt. Kumjeong was divided into 10 communities, 9 groups, 2 subgroups. 2. Eurya japonica group of Pinus densiflora community out of 16 vegetation units was thought as a indicator vegetation group which made it possible to border subtropical forest and south-temperate forest. 3. Natural regeneration of Stewartia koreana group was thought to be difficult because seedling and sapling was rarely showed, 4. In relationship between vegetation units and altitude, Carpinus tschonoskii community, Quercus variabilis community, Quercus serrata community, Wisteria floribunda community,. Eurya japonica group of Pinus densiflora community, Pinus thunbergii community mainly distributed below altitude 500 meter, and Quercus mongolica community, Typical group of Pinus densiflora community, Quercus dentata community, Carpinus coreana community, Quercus acutissima community mainly distributed above altitude 500 meter. 5. In relationship between vegetation units and topography, Carpinus tschonoskii community, Quercus variabilis community, Quercus serrata community, Wisteria floribunda community,. Eurya japonica group of Pinus densiflora community distributed below middle slope, Quercus mongolica community, Typical group of Pinus densifiora community, Quercus dentata community, Carpinus coreana community, Pinus thunbergii community Quercus acutissima communily clistributed above midclle slope.

  • PDF

Seasonal Variation of Contribution of Leaf-Litter Decomposition Rate in Soil Respiration in Temperate Deciduous Forest (토양호흡의 계절적 변이에 기여하는 리터의 분해속도)

  • Suh Sang-Uk;Min Youn-Kyung;Lee Jae-Seok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.57-65
    • /
    • 2005
  • In a forest ecosystem, the major source of soil carbon input is from litterfall and its decomposition. To understand the effect of litterfall and litter decomposition on seasonal variation of soil respiration and litter decomposition rates were measured in temperate deciduous forest in Korea. Annual litterfall collected from litter trap (1m x 1m) were 147.5 ± 8.2g Cm/sup -2/ yr/sup -1/ in 2003. About 47% of litterfall were Quercus serrata leaf followed by Carpinus laxiflora leaf (27 %), Carpinus cordata leaf (7 %), and others, such as other leaf, bark, branch, and acorn, were 20%. The decomposition rate was the highest in C. cordata (33.03%, k = 0.46), followed by C. laxiflora (25.73%, k = 0.30), and Q. serrata (24.17%, k = 0.28). The continuous measurement of soil respiration from January 2004 to December 2004 was carried out using AOCC (Automatic Open-Closed multi-Chamber system). The annual soil respiration rate was 629.6g Cm/sup -2/ yr/sup -1/ and the litter decomposition was 30.0g Cm/sup -2/ yr/sup -1/. The portion of litter decomposition rate on soil respiration rate was about 5%. From January to February, when the soil respiration rate was the lowest, about 11 % of soil respiration (7.4 ± l.4g Cm/sup -2/ month/sup -1/) were effected by litter decomposition rate (0.8g Cm/sup -2/ month/sup -1/). The highest soil respiration rate (111.5 ± 16.2g Cm/sup -2/ month/sup -1/) and litter decomposition rate (11.4g Cm/sup -2/ month/sup -1/) were showed in July to August. According to the regression analysis between soil respiration rate and litter decomposition, the soil respiration rate were related to litter decomposition with the correlations (r = 0.63).

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF