• Title/Summary/Keyword: $Ti_2AlN$/$Ti_2AlC$ materials

Search Result 84, Processing Time 0.026 seconds

Microstructure and Mechanical Properties of (Ti,Al)N Films Deposited by Ion Beam Sputtering (이온빔 스퍼터링에 의해 제조된 (Ti,Al)N 박막의 미세구조 및 기계적 특성)

  • Oh, Y.G.;Baeg, C.H.;Hong, J.W.;Wey, M.Y.;Kang, H.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.16 no.6
    • /
    • pp.329-334
    • /
    • 2003
  • Microstructure and mechanical properties of $(Ti_{1-x}Alx)N$ films, Produced by the the Ion Beam Sputtering(IBS) method, were studied by changing the Ti, Al contents. The compositions of films determined by RBS were $(Ti_{0.75}Al_{0.25})N$, $(Ti_{0.61}Al_{0.39})N$ and $(Ti_{0.5}Al_{0.5})N$, and XPS binding energies of Ti2P, A12p and N1s shifted to higher energies than those of pure Ti, Al and N, which indicated that nitrides were formed. XRD results indicated that the NaCl structure for $$x{\leq_-}0.39$$ changed into amorphous structure at x=0.5. For films with $$x{\leq_-}0.39$$, the lattice parameter decreased in proportion to the Al content. Nanoindentation hardness value were above HV=3300 at Al content up to x=0.39. However, the hardness of films with x=0.5 abruptly decreased to HV=1800, and this lower hardness values were attributed to different crystal structure. Critical load(Lc) in scratch test showed 23N at x=0.25, 22N at x=0.39 and 22N at x=0.5, which indicated that films with different Al contents showed similar adhesion behavior.

A Study on the Friction and Wear Characteristics of TiAlN+WC/C Multilayer Coating of SCM415 Steel (TiAlN+WC/C 다층코팅 SCM415강의 마찰•마모 특성에 관한 연구)

  • Jang, Jeong-Hwan;Kim, Nam-Kyung;Kim, Hae-Ji;Zang, Qi;Xu, Zhezhu;Lyu, SungKi
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • The purpose of this study is to show the friction and wear characteristics on the vapor deposited coating layers on the SCM415 steel. In this research, frictional wear characteristic of coating materials such as TiAlN+WC/C Multilayer Coating was investigated under room temperature, normal air pressure and nothing lubricating condition. Therefore this study carried out research on the friction coefficient, micro hardness(Hv), roughness, EPMA on the vapor deposited coating layers on the SCM415 steel. As the wear experimental result, the coefficient of friction decreased according to experimental load increases.

The ESCA Analysis of Hydroxyapatite Thin Films Deposited by RF Sputtering (RF 스퍼터링으로 증착된 하이드록시아파타이트 박막의 ESCA 분석)

  • Jung, Chan-Hoi;Lee, Jun-Hee;Kim, Soon-Kook;Kim, Myung-Han;Yu, Jae-Keun;Kim, Seung-Eon
    • Korean Journal of Materials Research
    • /
    • v.16 no.4
    • /
    • pp.264-271
    • /
    • 2006
  • RF sputtering process was applied to produce thin hydroxyapatite(HAp) films on Ti-6Al-4V alloy substrates. The effects of different heat treatment conditions on the chemical composites between HAp thin films and Ti-6Al-4V alloy substrates were studied. After deposition, the HAp thin films were heat treated for 1h at $400^{\circ}C,\;600^{\circ}C\;and\;800^{\circ}C$ under the atmosphere, and analyzed O/M, FESEM-EDX and ESCA, respectively. Experimental results represented that interface of HAp thin films and Ti-6Al-4V alloy substrates was composed Ti-OH, TiO, TiN, $Al_2O_3,\;V_2O_3,\;VO_2$. pyrophosphate and decreased carbide followed by the increase of heat treatment temperature.

EFFECTS OF SURFACE ROUGHNESS AND MULTILAYER COATING ON THE CORROSION RESISTANCE OF Ti-6Al-4V ALLOY

  • Ko, Yeong-Mu;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.134-135
    • /
    • 2003
  • The dental implant materials required good mechanical properties, such as fatigue strength, combined with a high resistance to corrosion. For increasing fatigue resistance and delaying onset of stress corrosion cracking, shot peening has been used for > 50 years to extend service life of metal components. However, there is no information on the electrochemical behavior of shot peened and hydroxyapatite(HA) coated Ti-6Al-4V alloys. To increase fatigue strength, good corrosion resistance, and biocompatibility, the electrochemical characteristics of Ti/TiN/HA coated and shot peened Ti-6Al-4V alloys by electron beam physical vapor deposition(EB-PVD) have been researched by various electrochemical method in 0.9%NaCl. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. The produced materials were quenched at 1000$^{\circ}C$ under high purity dried Ar atmosphere and were hold at 500$^{\circ}C$ for 2 hrs to achieve the fatigue strength(1140㎫) of materials. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. Shot peening(SP) and sand blasting treatment was carried out for 1, 5, and 10min. On the surface of Ti-6Al-4V alloys using the steel balls of 0.5mm and alumina sand of 40$\mu\textrm{m}$ size. Ti/TiN/HA multilayer coatings were carried out by using electron-beam deposition method(EB-PVD) as shown Fig. 1. Bulk Ti, powder TiN and hydroxyapatite were used as the source of the deposition materials. Electrons were accelerated by high voltage of 4.2kV with 80 - 120mA on the deposition materials at 350$^{\circ}C$ in 2.0 X 10-6 torr vacuum. Ti/TiN/HA multilayer coated surfaces and layers were investigated by SEM and XRD. A saturated calomel electrode as a reference electrode, and high density carbon electrode as a counter electrode, were set according to ASTM GS-87. The potentials were controlled at a scan rate of 100 mV/min. by a potentiostat (EG&G Co.273A) connected to a computer system. Electrochemical tests were used to investigate the electrochemical characteristics of Ti/TiN/HA coated and shot peened materials in 0.9% NaCl solution at 36.5$^{\circ}C$. After each electrochemical measurement, the corrosion surface of each sample was investigated by SEM.

  • PDF

Corrosion behaviors of Cp-Ti and Ti-6Al-4V alloys by TiN coating (TiN 코팅된 Ti 및 Ti-6Al-4V합금의 부식거동)

  • Lee, Soon-Hyun;Jung, Yoong-Hun;Choi, Han-Chul;Ko, Yeong-Mu
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.25-31
    • /
    • 2008
  • Cp-Ti and Ti-6Al-4V alloys commonly used dental implant materials, particularly for orthopaedic and osteosynthesis because of its suitable mechanical properties and excellent biocompatibility. This alloys have excellent corrosion behavior in the clinical environment. The first factor to decide the success of dental implantation is sufficient osseointegration and high corrosion resistance between on implant fixture and its surrounding bone tissue. In this study, in order to increase corrosion resistance and biocompatibility of Cp-Ti and Ti-6Al-4V alloy that surface of manufactured alloy was coated with TiN by RF-magnetron sputtering method. The electrochemical behavior of TiN coated Cp-Ti and Ti-6Al-4V alloy were investigated using potentiodynamic (EG&G Co, PARSTAT 2273. USA) and potentiostatic test (250mV) in 0.9% NaCl solution at 36.5 $\pm$ 1$^{\circ}C$. These results are as follows : 1. From the microstructure analysis, Cp-Ti showed the acicular structure of $\alpha$-phase and Ti-6Al-4V showed the micro-acicular structure of ${\alpha}+{\beta}$ phase. 2. From the potentiodynamic test, Ecorr value of Cp-Ti and Ti-6Al-4V alloys showed -702.48mV and -319.87mV, respectively. Ti-6Al-4V alloy value was higher than Cp-Ti alloy. 3. From the analysis of TiN and coated layer, TIN coated surface showed columnar structure with 800 nm thickness. 4. The corrosion resistance of TiN coated Cp-Ti and Ti-6Al-4V alloys were higher than those of the non-coated Ti alloys in 0.9% NaCl solution from potentiodynamic test, indicating better protective effect. 5. The passivation current density of TiN coated Cp-Ti and Ti-6Al-4V alloys were smaller than that of the noncoated implant fixture in 0.9% NaCl solution, indicating the good protective effect resulting from more compact and homogeneous layer formation.

  • PDF

A Study on the Reaction of Al-1% Si with Ti-silicide (Al-1% Si층과 Ti-silicide층의 반응에 관한 연구)

  • Hwang, Yoo-Sang;Paek, Su-Hyon;Song, Young-Sik;Cho, Hyun-Choon;Choi, Jin-Seog;Jung, Jae-Kyoung;Kim, Young-Nam;Sim, Tae-Un;Lee, Jong-Gil;Lee, Sang-In
    • Korean Journal of Materials Research
    • /
    • v.2 no.6
    • /
    • pp.408-416
    • /
    • 1992
  • Stable TiS$i_2$was formed by RTA on single-Si and on poly-Si. Subsequently, an Al-1% Si layer with 600-nm thick was deposited on top of the TiS$i_2$, Finally, the specimens were annealed for 30min at 400-60$0^{\circ}C$in $N_2$ambient. The thermal stability of Al-1% Si/TiS$i_2$bilayer and interfacial reaction were investigated by measuring sheet resistance, Auger electron spectroscopy (AES), and scanning electron microscopy (SEM). The composition and phase of precipitates formed by the reaction of Al-1% Si with Ti-silicide were studied by energy dispersive spectroscopy (EDS), X-ray diffraction (XRD). In the case of single-Si substrate the reaction of Al-1% Si layer with TiS$i_2$layer resulted in precipitates, consuming all TiS$i_2$layer at 55$0^{\circ}C$. On the other hand, the disappearance of TiS$i_2$on poly-Si occurred at 50$0^{\circ}C$ and more precipitates were formed by the reaction of Al-1% Si/TiS$i_2$on potty-Si substrate than those of the reaction on single-Si substrate. This phenomenon resulted from the fact that Ti-silicide formed on poly-Si was more unstable than on single-Si by the effect of grain boundary. By EDS analysis the precipitates were found tobe composed of Ti, Al, and Si. X-ray diffraction showed the phase of precipitates to be theT$i_7$A$l_5$S$i_12$ternary compound.

  • PDF

Microstructural and Mechanical Characteristics of TiZrAlN Nanocomposite Thin Films by CFUBMS (CFUBMS을 이용한 TiZrAlN 나노복합 박막의 미세 구조와 기계적 특성)

  • Kim, Youn-J.;Lee, Ho-Y.;Kim, Yong-M.;Kim, Kab-S.;Han, Jeon-G.
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Quaternary TiZrAlN nanocomposite thin films were synthesized by Closed-Field Unbalanced Magnetron Sputtering (CFUBMS), and their microstructure and mechanical characteristics were examined. The grain refinement of the TiZrAlN nanocomposite thin films was controlled by adjusting the $N_2$ partial pressure. The hardness of the film varied with the $N_2$ partial pressure and the maximum value was obtained approximately 47 GPa. It was also confirmed that there is a critical value of the grain size($d_c$) to need maximum hardness.

Preparation of precision thin film resistor sputtered by magnetron (IC용 초정밀 박막저항소자의 제조와 특성연구)

  • 하홍주;장두진;조정수;박정후
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.13-20
    • /
    • 1995
  • To develope a high precision TiAIN thin film resistor, TiAIN films were deposited on A1$_{2}$03 substrates by reactive planar magnetron cosputtering from Ti and Al targets in an Ar-N$_{2}$ atmosphere. The characteristics of the TiAIN thin film were controlled by changing of the R.F. power on Ti and Al targets, and the N$_{2}$ partial pressure. The high precision TiAIN thin film resistor with TCR(Temperature Coefficient of Resistance) of less than 10ppm/.deg. C was obtained under the R.F. power condition of 160(w)/240(w) to Ti and Al targets at the N$_{2}$ partial pressure of 7*10$^{-5}$ Torr. The composition of these films were investigated by XRD, SEM and EDS.

  • PDF

Surface Characteristics of Porous Ti-6Al-4V Implants Fabricated by Electro-Discharge-Sintering in a Low Vacuum Atmosphere (저진공 분위기 전기방전소결에 의해 제조된 다공성 Ti-6Al-4V 임플란트의 표면특성 연구)

  • Hyun, C.Y.;Huh, J.K.;Lee, W.H.
    • Korean Journal of Materials Research
    • /
    • v.16 no.3
    • /
    • pp.178-182
    • /
    • 2006
  • A single electro-discharge-sintering (EDS) pulse (1.0 kJ/0.7 g), from a $300{\mu}F$ capacitor, was applied to atomized spherical Ti-6Al-4V powder in a low vacuum to produce porous-surfaced implant compacts. A solid core surrounded by a porous layer was formed by a discharge in the middle of the compact. XPS (X-ray photoelectron spectroscopy) was used to study the surface characteristics of the implant material. C, O, and Ti were the main constituents, with smaller amounts of Al, V, and N. The implant surface was lightly oxidized and was primarily in the form of $TiO_2$ with a small amount of metallic Ti. A lightly etched EDS implant sample showed the surface form of metallic Ti, indicating that EDS breaks down the oxide film of the as-received Ti-6Al-4V powder during the discharge process. The EDS Ti-6Al-4V implant surface also contained small amounts of aluminum oxide in addition to $TiO_2$. However, V detected in the EDS Ti-6Al-4V implant surface, did not contribute to the formation of the oxide film..

Surface Treatment of IHX Materials for VHTR (원자력 중간열교환기 열수송계 소재의 표면처리)

  • Lee, Byeong-U;Lee, Myeong-Hun;Bang, Gwang-Hyeon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.35-50
    • /
    • 2012
  • $900^{\circ}C$이상 초고온 He-gas 분위기 또는 용융불화염 (molten salts, FLINAK) 환경에서 사용될 VHTR(Very High Temperature Reactor)의 IHX(Intermediate heat exchanger)용 열수송 구조재료로 가장 가능성이 높은 합금인 Inconel 617 및 Hastelloy X 상에 습식화학적, 물리적기상합성법(Vacuum arc-plasma과 RF magnetron sputtering) 및 pack cementation에 의한 표면개질 및 마이크로 초내열(refractory ceramics) 코팅층(TiN, TiCN, TiAlN, $Al_2O_3$, $TiO_2$)을 형성시켰다. 고온 장기사용 시 문제가 될 수 있는 고온에서의 조직변화, 미세구조와 상(phase)형성, 고온 부식 및 그에 따른 마모(wear resistance) 손상 등 이들 소재의 내열, 내식 및 내마모 물성을 개선하는 연구를 수행하였다. TiAlN 박막의 경우 공기분위기에서 N이 분해되나 치밀한 산화물($TiO_2/Al_2O_3$ layer)을 형성하여 내식성 있는 보호피막을 형성함으로 기판과의 열팽창 계수로 인한 박리가 발생하지 않아 보호피막으로 적합하였다. Pack cementation법에 의한 aluminiding(Al-Ni합금)도 He 및 공기분위기에서 고온물성의 저하를 가져오는 $Cr_2O_3$의 생성을 충분히 억제하고 있었으며 He 및 air 분위기에서 사용이 가능한 박막으로 여겨진다. 내열 및 내식성에 대한 실험을 종합한 결과, 공기분위기에서 사용할 수 없는 박막은 He-gas 및 FLINAK(LiF-NaF-KF) 용융염 분위기에서도 사용할 수 없었으며, He-gas, FLINAK 및 air 분위기에서 모두 사용이 가능한 박막으로는 Inconel 617에서는 $(TiO_2-)Al_2O_3$, TiAlN 및 Al-Ni이었고 Hastelloy에서는 Al-Ni 및 $Al_2O_3$가 가장 적당하였다.

  • PDF