• Title/Summary/Keyword: $TiOF_2$

Search Result 10,582, Processing Time 0.044 seconds

THE COMPARISON OF CANAL SHAPING ABILITY BY ENGINE-DRIVEN NICKEL-TITANIUM FILE AND ENDOSONIC FILE IN CURVED CANAL (만곡 근관에서 엔진 구동용 Ni-Ti File과 초음파 기구에 의한 근관성형 능력의 비교)

  • Kim, Hyun-Ju;Oh, Won-Mann;Yang, Kyuo-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.758-767
    • /
    • 1995
  • The purpose of this study was to evaluate canal shaping ability after canal preparation by using engine-driven nickel-titanium file and endosonic file in curved canals. 30 mesiobuccal canals of molars extracted within recent 3 months were divided into 3 groups. Group I and group II were prepared by using engine-driven nickel-titanium Gates-Glidden drill type and the engine-driven nickel-titanium file type. Group III prepared by using en do sonic file. The image of preinstrumented canals was taken by X-ray. The image of postinstrumented canal was taken by X-ray in the same condition of preinstrumentation. A magnified X-ray image on magnifier screen was traced and then compared the preinstrumentated canal image with the postinstrumentated canal image by superimposing method. The following results were obtained : 1. In the change of canal curvature, the engine-driven nickel-titanium Gates-Glidden drill type showed the least change and the ultrasonically filing showed the greatest change. 2. In the percentage of canal enlargement, the engine-driven nickel-titanium file type was greatest at all level(p<0.05), the apex of all group was the greatest, the difference of ultrasonically filing group showed greater between apex and cervix. 3. The percentage of canal enlargement on convex side was greater than that of on concave side in apex of each group(p<0.05). In the ultrasonically filing group, both sides of canal enlargement showed sharply difference(p<0.01). 4. The percentage of canal enlargement on convex side was greater than that of on concave side in the third of cervix of the engine-driven nickel-titanium file type and the ultrasonically filling. The percentage of canal enlargement of convex and concave side in the third of middle of the engine-driven nickel-titanium Gates-Glidden drill type show a similar canal enlargement between convex side and concave side. As above result, the engine-driven nickel-titanium file type was greater in canal enlargement than the other instruments. The engine-driven nickel-titanium Gates-Glidden dirll type was efficient endodontic instrument for curved canal preparation because it was least change in canal curvature.

  • PDF

COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK (타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교)

  • Lee, Young-Jae;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.431-443
    • /
    • 2007
  • Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.

Liriopis Tuber improves stress-induced memorial impairments in rats (구속 스트레스로 유발된 기억 손상에 대한 맥문동(麥門冬)의 신경보호 효능)

  • Kang, Young-Gun;Lee, Tae-Hee
    • The Korea Journal of Herbology
    • /
    • v.21 no.2
    • /
    • pp.63-75
    • /
    • 2006
  • Objectives : We investigated the effects of Liriopis Tuber on the nervous protection. Methods : We measured the reaction behavior with EPM(Elevated Plus Maxe) and MWM(Morris Water Maze) after applying restraint stress to rats. Also, the degrees of AchE generation were measured with immunohistochemical method in the regions of hippocampus, and the degree of TH generation in the regions of VTA and LC, respectively. Results : 1. As the results of measuring how long EPM which reflects anxiety reaction stayed in the open arm, there was the trend which can suppress anxiety reaction in the MMD+stress group(Liriopis Tuber+stress) but no statistical significance. The counting results how many EPM passed between opened and closed arm showed suppression trend against a physical activity in the saline+stress group but there was no statistical significance. 2. According to the result of MWM, the saline+stress group showed the learning retardation which means increased time arriving at goal compared to ti1e normal group at the second and third day of measurement. On the contrary, a learning retardation was significantly decreased in the MMD+stress group. Among the probe trial test a memory loss occurred in the saline+stress group, meanwhile memory ability was notably increased in the saline-stress group. 3. The degree of TH generation was investigated at the VTA and LC respectively after test animals treated with drug. In the saline+stress group, TH-immunoreactive cells were significantly increased, and these stress-induced TH increases were suppressed in the saline+stress group at the VTA region. However, the saline+stress group did not show any significant difference. 4. the degree of AchE generation was investigated at the CA3 of hippocampus. The saline+stress group showed that AchE-immunoreactive cells were significantly decreased. Those stress-induced reductions of AchE cells were meaningfully recovered in the saline+stress group. Although the cells showed recovery trend in the region of CA1 of hippocampus, statistical significance was not observed. Conclusion : The results of our study indicate that Liriopis Tuber can improve spatial memory ability of rats applied a restraint stress. This improvement of the spatial memory ability is considered to have an efficacy of nervous protection that Liriopis Tuber suppresses the generation of AchE in the hippocampus region and enhances the generation of TH in the VTA.

  • PDF

A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE (ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구)

  • Lee, Bo-Kum;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.294-302
    • /
    • 2005
  • The purpose of this study was to evaluate the canal configuration after shaping by ProFile. ProTaper and K-Flexofile in simulated resin canals with different angles of curvature. Three types of instruments were used: ProFile. ProTaper. K-Flexofile. Simulated root canals. which were made of epoxy resin. were prepared by ProFile. ProTaper with rotary instrument using a crown-down pressureless technique. and hand instrumentation was performed by K-Flexofile using a step-back technique. All simulated. canals were prepared up to size 25 file at end-point of preparation. Pre and post instrumentation images were recorded with Scanner. Assessment of canal shape was completed with Image Analysis program. Measurements were made at 1. 2. 3. 4. 5. 6. 7. 8. 9 and 10mm from the apex. At each level. outer canal width. inner canal width. total canal width. and amount of transportation from original axis were recorded. Instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA analysis of variance and the Sheffe's test. The result was that ProFile and ProTaper maintain original canal shape regardless of the increase of angle of curvature than K-Flexofile. ProFile show significantly less canal transportation and maintained original canal shape better than ProTaper.

Determination of Optimized Operational Parameters for Photocatalytic Oxidation Reactors Using Factorial Design (요인분석법을 이용한 광촉매 산화반응조의 최적 운영인자 도출)

  • Hur, Joon-Moo;Cheon, Seung-Yul;Rhee, In-Hyoung;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.2
    • /
    • pp.85-91
    • /
    • 2004
  • The objective of this study is to determine the optimum conditions of operational parameters using factorial design for phenol degradation in photocatalytic oxidation reactors. Factorial design is widely used to select the dominant factors and their ranges in experiments involving several factors where it is necessary to study the effect of factors on a response. The effects of initial concentration of phenol, intensity of UV light and surface area of catalyst on phenol degradation were investigated. Two levels were considered in this study so that the experiment was a $2^3$ factorial design with three replicates. The experimental results show that an increase in initial concentration of phenol from 5 to 50 mg/L intensity of UV light from 5,000 to $20,000\;{\mu}W/cm^2$, and surface area of catalyst from 740 to $2,105\;cm^2$ enhanced the phenol degradation rate by an average of 1.86, 1.79, and 2.10 mg/L hr, respectively. Interaction effects do not appear to be as large on the phenol degradation rate as the main effects of single factors. The optimum working condition for photocatalytic oxidation reactors, despite the higher three factors the better removal rate, is the highest surface area or catalyst.

Study on Dosimetric Properties of Radiophotoluminescent Glass Rod Detector (유리선량계의 선량 특성에 관한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Hong, Ju-Young;Kim, Hee-Sun;Lim, Chun-Il;Jeong, Hee-Gyo;Suh, Tea-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.181-186
    • /
    • 2006
  • A radiophotoluminescent glass rod detector (GRD) system has recently become commercially available. We investigate the dosimetric properties of the GRD regarding the reproducibility of signal, dose linearity and energy dependence. The reproducibility of five measurements for 50 GRDs is presented by an average of one standard deviation of each GRD and it is ${\pm}1.2%$. It is found to be linear in response to doses of $^{60}Co$ beam in the range 0.5 to 50 Gy with a coefficient of linearity of 0.9998. The energy dependence of the GRD is determined by comparing the dose obtained using cylindrical chamber to that by using the GRD. The GRD response for each beam is normalized to the response for a $^{60}Co$ beam. The responses for 6 and 15 MV x-ray beams are within ${\pm}1.5%$ (1SD). The energy response of GRD for high-energy photon is almost the same as the energy dependence of LiF:Mg:Ti (TLD-100)and shows little energy dependence unlike p-type silicon diode detector. The GRDs have advantages over other detectors such diode detector, and TLD: linearity, reproducibility and energy dependency. It has been verified to be an effective device for small field dosimetry for stereotactic radiosurgery.

A Study of Electro-Optical Properties of Polyester Acrylate-Based Polymer-Dispersed Liquid Crystals Using TIZO/Ag/TIZO Multilayer Transparent Electrodes (TIZO/Ag/TIZO 다층막 투명전극을 이용한 폴리에스터 아크릴레이트 기반 고분자분산액정의 전기광학적 특성 연구)

  • Cho, Jung-Dae;Heo, Gi-Seok;Hong, Jin-Who
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-57
    • /
    • 2022
  • Ti-In-Zn-O (TIZO)/Ag/TIZO multilayer transparent electrodes were prepared on glass substrates at room temperature using RF/DC magnetron sputtering. Obtained multilayer structure comprising TIZO/Ag/TIZO (10 nm/10 nm/40 nm) with the total thickness of 60 nm showed a transmittance of 86.5% at 650 nm and a sheet resistance of 8.1 Ω/□. The multilayer films were expected to be applicable for use in energy-saving smart window based on polymer-dispersed liquid crystal (PDLC) because of their transmittance properties to effectively block infrared rays (heat rays). We investigated the effects of the content ratio of prepolymer, the thickness of the PDLC coating layer, and the ultraviolet (UV) light intensity on electro-optical properties, and the surface morphology of polyester acrylate-based PDLC systems using new TIZO/Ag/TIZO transparent conducting electrodes. A PDLC cell with a thickness of 15 ㎛ PDLC layer photocured at an UV intensity of 1.5 mW/cm2 exhibited good driving voltage, favorable on-state transmittance, and excellent off-haze. The LC droplets formed on the surface of the polymer matrix of the PDLC composite had a size range of 1 to 3 ㎛ capable of efficiently scattering incident light. Also, the PDLC-based smart window manufactured using TIZO/Ag/TIZO multi-layered transparent electrodes in this study exhibited a light brown, which will have an advantage in terms of aesthetics.

Mineralogical Characteristics of Tachylite occurring in Basic Dike, Basaltic Agglomerate Formation, Ulleung Island and Its Implications of Volcanic Activity (울릉도의 하부층 현무암질 집괴암 층내 염기성 암맥에서 산출되는 타킬라이트의 광물학적 특성과 화산학적 의미)

  • Bae, Su-Gyeong;Choo, Chang-Oh;Jang, Yun-Deuk
    • Journal of the Mineralogical Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.63-76
    • /
    • 2012
  • Tachylite, black basaltic glass formed by the rapid cooling of molten basalt, locally occurs at the Basaltic Agglomerate Formation (BAF), the lowest formation of Ulleung Island. The purposes of this study are to characterize the occurrence and mineralogy of tachylite and to elucidate its formation condition, with emphasis on its fracture pattern, which can serve as implications for the early volcanic activity of Ulleung Island. To this end, we investigated the occurrence pattern of tachylite in the field and carried out mineralogical analyses using optical microscope, XRD, EPMA, and SEM. Tachylite occurs at the chilled margin of basic dikes which are distributed in Naesujeon, Dodong and Jeodong seasides, Turtle Rock, and Yaerimwon, whose widths vary from several cm to 10 cm. It is evident that the outer surface of tachylite is dense and smooth, whereas the inner surface, if fractured, is characterized by conchoidal fracture. The matrix of tachylite consists of amorphous, glass and some fine-grained phenocrysts present in tachylite include biotite, anorthoclase, sanidine, plagioclase, hornblende, and Fe-Ti oxides. The fracture patterns characteristic of tachylite are subrounded, oval, or less commonly polygonal, bounded by joints to form globule or lump. Taking into account texture and mineralogy, tachylite is interpreted to have undergone little subsequent alteration at low temperature via hydration or hydrolysis that could form clay minerals after it was formed. Because tachylite with peculiar fractures occurs as dikes in a close association with BAF, its presence is considered as reliable evidence that when tachylite formed, the most part of BAF was still under subaqueous conditions, or at least saturated with seawater.

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

Study of Anti-inflammatory Activity of 7 Herbal Prescription Effective for Sleep Disorders and Atopic Dermatitis (수면 장애 및 아토피피부염에 효과적인 7 가지 한약 처방의 항염증 활성 연구)

  • Choi, Min-Jin;Nguyen, Ly Thi Huong;Jeong, Jeonghwa;Park, Minyoung;Yoon, Joohee;Lee, Byung-Wook;Yang, In-Jun;Shin, Heung-Mook
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.2
    • /
    • pp.56-63
    • /
    • 2021
  • This study was conducted to find a candidate prescription with anti-inflammatory efficacy of 7 herbal prescriptions known to be effective in atopic dermatitis and sleep disorders in Korean medicine. The anti-inflammatory of the 7 herbal prescriptions extracts were evaluated by ELISA assay and Western blot assay. 7 herbal prescriptions, Seongyutang(SU), Danseontoetang(DST), Sotosajahwan(ST), Jisiljagyagsan(JJ), Seokchangpo(SCP), Wiryeongseon(WLS), Gogojohwan(GGJ) 30 % EtoH extract was used for in vitro experiments. In TNF-α + IFN-γ(TI) stimulated HaCaT cells, all 7 herbal prescriptions reduced TARC and MDC production, and JJ strongly reduced TARC and MDC production at 100 ㎍/ml concentration. SCP strongly reduced MDC production at 10 ㎍/ml and 100 ㎍/ml concentration. In addition, in substance P(SP)/CRH stimulated HMC-1 cells, JJ strongly inhibited VEGF production at both 10 and 100 ㎍/ml concentrations. In LPS/CRH stimulated Raw264.7 cells, all 7 herbal prescriptions significantly inhibited TNF-α. PMA + Ionomycin(PI)/CRH stimulated EL4 cells, SU significantly reduced IL-4 production at both concentrations of 10 and 100 ㎍/ml. WLS significantly reduced IL-17 production at both concentrations of 10 and 100㎍/ml. This suggests that 7 herbal prescriptions have anti-inflammatory effects by reducing inflammatory cytokines in keratinocytes, mast cells and macrophages caused by inflammation. Therefore, it is expected that 7 herbal prescriptions that are effective for sleep disorders and atopic dermatitis can be used as therapeutic materials for sleep disorders and diseases associated with atopic dermatitis.