Study on Dosimetric Properties of Radiophotoluminescent Glass Rod Detector
![]() |
Rah, Jeong-Eun
(Dept. of Biomedical Engineering, College of Medicine, Catholic University)
Shin, Dong-Oh (Dept. of Radiation Oncology, College of Medicine, Kyung Hee University) Hong, Ju-Young (Dept. of Biomedical Engineering, College of Medicine, Catholic University) Kim, Hee-Sun (Radiation Health Research Institute) Lim, Chun-Il (Radiation Standards Division, Korea Food & Drug Administration) Jeong, Hee-Gyo (Medical Devices Standardization Division, Korea Food & Drug Administration) Suh, Tea-Suk (Dept. of Biomedical Engineering, College of Medicine, Catholic University) |
1 | Kubo HD, and Araki F. Dosimetry and mechanical accuracy of the first rotating Gamma-Knife system installed in North America. Med. Phys. 2002;29:2497-2505 DOI ScienceOn |
2 |
Rickner G. Characteristic of a selectively shield p-Si detector in |
3 | Araki F, Ikegami T, Ishidoya T, and Kubo DH. Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector. Med. Phys. 2003;30:1976-1981 DOI ScienceOn |
4 | TRS No 277, Absorbed dose determination in photon and electron beams. An International Code of Practice for Dosimetry. IAEA. Vienna: 1983 |
5 | Asahi Techno Glass Corporation. Explanation material of RPL glass dosimeter: Small element system. Tokyo. Japan. 2000 |
6 | Mobit PN, Nahum AE and Mayles P. The energy correction factor of LiF thermoluminecent dosimeters in megavoltage electron beams: Monte Carlo simulation and experiments. Phys. Med. Biol. 1996;41:979-993 DOI ScienceOn |
7 | Mobit PN, Nahum AE, and Mayles P. A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams. Phys. Med. Biol. 1998;43:2015-2032 DOI ScienceOn |
8 | Mobit PN, Mayles P, and Nahum AE. The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments. Phys. Med. Biol. 1996;41:387-398 DOI ScienceOn |
9 | Rickner G, and Grusell E. Selective shielding of a p-Si detector for quality independence. Acta Radiol. Oncol. 1985;24:65-69 DOI ScienceOn |
10 | Lee HR, Pankuch M, Chu JC, and Spokas JJ, Evaluation and characterization of parallelplate microchamber's functionalities in small beam dosimetry. Med. Phys. 2002;29:2489-2496 DOI ScienceOn |
11 | Tsuda M. A few remarks on photoluminescence dosimetry with high energy x-rays. Jpn. J. Med. 2000;20:131-139 |
12 | Heydarian M, Hoban PW, and Beddoe AH. A comparison of dosimetry techniques in stereotactic radiosurgery. Phys. Med. Biol. 1996;41:93-110 DOI ScienceOn |
![]() |