• Title/Summary/Keyword: $SO_2$ concentration

Search Result 3,806, Processing Time 0.044 seconds

The influence on air quality of the surroundings by the facility of the district heating (집단 에너지 시설에 의한 주변 대기질 영향)

  • 연익준;주소영;이민희;손종렬;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.18-25
    • /
    • 2002
  • The comparison of the air quality with the evaluation of the environmental assessment before and after operations of the heat source and of the flue-gas desulfurization facilities were studied. First of all, several sites were selected for the representative sample points, and then they were examined air quality of the surroundings. The results were that TSP(total suspended particulate) analysis after an operation of the heat source facility was $74~81{\mu}g/m^3$, PM-10 was $31~94{\mu}g/m^3$, and $SO_2$concentration was 0.002~0.009ppm, respectively. As the result of examination to the concentrations of diffused pollutants, there was no relations between TSP concentration of sample points and the effect of air quality according to the heating source. When we compared the neighbored area of the heating source with the other area, the concentration of air pollutants after an operation of the facility of the heating source was similar to the heating source, the neighbored area, and the other area. So we concluded that there was no the effect of the air pollution by producted pollutants from the heating source.

Analysis of Air Pollution Concentrations at Cheju Baseline Measurement Station (제주도 고산 측정소에서의 대기오염 배경농도 측정 및 분석)

  • 박경윤;이호근;서명석;장광미;강창희;허철구;김영준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.252-259
    • /
    • 1994
  • A ground station has been established at Kosan, Cheju Island, since January of 1992 for the monitoring of background air Pollutant levels in Korea. Anthropogenic pollutant sources and meteorological conditions of Kosan were surveyed. Concentrations of SO$_2$, NO, NO$_{y}$ and $O_3$, were measured and analyzed for the period of February through December, 1992. The annual means of NO and SO$_2$, levels were very low in comparison to other urban's levels and similiar to other country's background levels. The annual mean of $O_3$, level was higher than urban's but comparable to other coastal region's. The NO concentration showed a distinct seasonal and diurnal variations. Summer peak was detected in the monthly means of NO and smooth peak around noon was found in the annual means of hourly data. Diurnal variation of the SO$_2$ concentration was barely detected but a slice increase in winter was detected. The $O_3$, concentration data, however, showed seasonal and diurnal variations similar to the urban's.an's.

  • PDF

Co-deposition of Si Particles During Electrodeposition of Fe in Sulfate Solution (황산철 도금액 중 Si 입자의 공석 특성)

  • Moon Sung-Mo;Lee Sang-Yeal;Lee Kyu-Hwan;Chang Do-Yon
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.6
    • /
    • pp.319-325
    • /
    • 2004
  • Fe thin films containing Si particles were prepared on metallic substrates by electrodeposition method in sulfate solutions and the content of codeposited Si particles in the films was investigated as a function of applied current density, the content of Si particels in the solution, solution pH, solution temperature and concentration of $FeSO_4$$7H_2$O in the solution. The amount of Si codeposited in the film was not dependent on the applied current density, solution pH and solution temperature, while it was dependent on the content of Si particles in the solution and the concentration of $FeSO_4$$7H_2$O in the solution. The amount of Si codeposited in the film increased with increasing content of Si particles in the solution but reached a maximum value of about 6 wt% when the content of Si particles in the solution exceeds 100 g/l. On the other hand, the content of Si codeposited in the film increased up to about 17 wt% with decreasing concentration of $FeSO_4$$7H_2$O in the solution. These results would be applied to the fabrication of very thin Fe-6.5 wt% Si sheets for electrical applications.

Seasonal Variation and Statistical Analysis of Particulate Pollutants in Urban Air (도시대기립자상물질중 오염성분의 계절적 변동 및 통계적 해석)

  • 이승일
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.8-23
    • /
    • 1994
  • During the period from Mar., 1991 to Feb., 1992 66 tSP samples were collected by Hi volume air sampler at 1 sampling site in Seoul and the amount of concentration of 21 components(SO$_{4}$$^{2-}$, NO$_{3}$$^{-}$, NH$_{4}$$^{+}$, Cl$^{-}$, Al, Ba, Ca, Cd, Cr, Cu, Fe, It Mg, Mn, Na, Ni, Pt Si, Ti, Zn, Zr ) were measured. And monthly and seasonal variation were surveyed and the principal component analysis( PCA ) were carried out with respect to these amount of pollutants, minimum of visibility and radiation on a horizontal surface. The total amount of soluble ion in water was high in order o(SO$_{4}$$^{2-}$> NO$_{3}$$^{-}$> N%'>Cl$^{-}$ and metal ion was high in order of Na> Ca>Si> Fe> Al> K> Mg> Zn> Pb> Cu>Ti> Mn > Ba> Cr> Zr> Ni> Cd. There was Seasonal variation in concentration for SO$_{4}$$^{2-}$, NH$_{4}$$^{+}$, Cl$^{-}$, Na, Al, Ca, Bt Mg, Fe and Si. It was assumed that the components of the highest concentration on April were depend on yellow sand and the frequency of wind velocity and direction. As the results of PCA, the amount of pollution components was able to characterized with two principal components(Z$_{1}$, Z$_{2}$ ). The first principal components Z$_{1}$ was considered to be a factor indicating the pollutants originated from natural generation and The second principal components Z$_{2}$ was considered to be a factor indicating the pollutants originated from human work. The monthly concentration of pollutants in ISP, minimum of visibility and radiation on a horizontal surface was possible to evaluate by the use of these two principal components Z$_{1}$ and Z$_{2}$ .

  • PDF

Utilization of Pine Bark (Part 5) -Alkaline Sulfite-Anthraquinone Delignification of Pine Bark- (소나무 수피의 총합적 이용 (제5보) -소나무 수피의 알칼리성 아황산염-안트라퀴논에 의한 탈리그닌-)

  • Mun, Sung-Phil;Park, Sung-Chun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.46-52
    • /
    • 1999
  • Alkaline sulfite-anthraquinone(AQ) cooking was examined for their effectiveness in delignification of pine (Pinus densiflora S. et Z.) bark. Better delignification was achieved with alkaline sulfite liquor compared to monosulfite liquor, but the degree of delignification was less than 90% indicating need for improvement in cooking method, Remarkable increase in the rate of cooking and delignification was obtained by the simple addition of AQ to the alkaline sulfite cooking, Selectivity of delignification was also improved by the addition of AQ, Consequently, 90% of delignification was achieved with the addition of 0.2% AQ to the alkaline sulfite cooking. The selectivity of delignification was slightly affected by cooking temperature and NaOH concentration during alkaline sulfite-AQ cooking of the bark. The selectivity of delignification was highly affected by the concentration of $Na_2SO_3$, and the optimum concentration of $Na_2SO_3$ for the high delignification was 30% as $Na_2O$.

  • PDF

[Retracted]Gas Mask Removal Efficiency of CO, HCl, HCN, and SO2 Gas Produced by Fire ([논문철회]화재용 방독면의 CO, HCl, HCN, SO2 연소생성물 제거효율)

  • Kong, Ha-Sung;Gong, Ye-Som;Kim, Sang-Heon
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.57-60
    • /
    • 2015
  • The removal efficiencies by elastic fire gas mask of toxic gases CO, HCl, HCN, and $SO_2$ produced by a fire have a key role in saving lives. The elastic fire gas mask comprises a visible window, elastic hood, gas purification canister, and air vent. It does not have hair or neck thongs, which makes it easy to use and put on quickly. This research examined the removal efficiency of toxic gases by such a mask. The removal efficiencies for CO with a background concentration of 2505.0 ppm were 99.99 and 99.98% after 3.5 and 8.5 min, respectively. The residual CO concentration was drastically increased after 8.5 min. The removal efficiencies for HCl, HCN, and $SO_2$ with background concentrations of 1003.0, 399.0, and 100.3 ppm, respectively, were 100% after 20 min.

A Survey on the Status of Air Pollution around Toll Booth of Expressway -Around Seoul and Suwon Toll Booth- (고속도로 요금소 주변의 대기오염에 관한 조사연구 -서울 및 수원 요금소를 중심으로-)

  • 이윤재;김정철;김광종;송동빈;차철환;권영근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.79-83
    • /
    • 1988
  • To improve working environment for the toll workers who were working at Kyungbu expressway in outskirts of Seoul and Suwon, the status of air pollution surrounding toll booth were measured from March 28 through June 14, 1986. The results were as follows: 1. The amount of TSP (total suspended particle) surrounding toll booth was directly proportional to the traffic load. The ratio of traffic load at Seoul and Suwon toll was 3.2:1 and of TSP was 2.6:1. 2. The proportion of particle larger than 5$\mum$ was 24.8 $\sim$ 34.9% of TSP at Seoul toll and 19.2 $\sim$ 32.7% at Suwon. The proportion of particle less than 2$\mum$ was 38.7 $\sim$ 51.8% of TSP at Seoul toll and 34.8 $\sim$ 54.8% at Suwon. 3. The concentration of respirable particle les than 7$\mum$ measured by personal air sampler was higher in Seoul toll booth than that of Suwon and it seems to be influenced by the exhausion of diesel engine. Especially the concentration of respirable particle of reformed toll booth with air curtain was 20% lower than unreformed one. 4. Concentration of Pb among suspended particles around Seoul toll was 5 times higher than Pb of Suwon toll. So it is considered that there were other possible pollution source of Pb beyond heavy traffic in Seoul toll area. The amount of Pb inside toll booth was extremely small but the concentration of benzo(a)pyrene showed a trend of increase according to traffic stagnation. 5. The concentration of $SO_2$ arround toll showed no difference between weekday and weekend and also showed no relation with traffic load. But the concentration of $NO_2$ was affected by traffic load.

  • PDF

Preparation of Ni(OH)2 Hollow Spheres by Solvent Displacement Crystallization Using Micro-Injection Device (마이크로 주입장치를 이용한 용매치환결정화에 의한 중공상 수산화니켈 분말의 제조)

  • Kim, Seiki;Park, Kyungsoo;Jung, Kwang-Il
    • Journal of Powder Materials
    • /
    • v.23 no.4
    • /
    • pp.311-316
    • /
    • 2016
  • $Ni(OH)_2$ hollow spheres have been prepared by solvent displacement crystallization using a micro-injection device, and the effect of process parameters such as concentration and the relative ratio of the injection speed of the precursor solution, which is an aqueous solution of $NiSO_4{\cdot}6H_2O$, to isopropyl alcohol of displacement solvent have been investigated. The crystal phases after NaOH treatment are in the ${\beta}-phase$ for all process parameters. A higher concentration of $NiSO_4{\cdot}6H_2O$ aqueous solution is injected by a micro-injection device and bigger $Ni(OH)_2$ hollow spheres with a narrower particle size distribution are formed. The crystallinity and hardness of the as-obtained powder are so poor that hydrothermal treatment of the as-obtained $Ni(OH)_2$ at $120^{\circ}C$ for 24 h in distilled water is performed in order to greatly improve the crystallinity. It is thought that a relative ratio of the injection speed of $NiSO_4{\cdot}6H_2O$ to that of isopropyl alcohol of at least more than 1 is preferable to synthesize Ni(OH)2 hollow spheres. It is confirmed that this solution-based process is very effective in synthesizing ceramic hollow spheres by simple adjustment of the process parameters such as the concentration and the injection speed.

Statistical Aspects and the Extimation Scheme of the Short Term Concentration of Air Pollution (大氣汚染濃度의 發生頻度特徵 및 推定法 評價)

  • Lee, Chog-Bum;Kang, In-Goo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.88-95
    • /
    • 1989
  • The aspects of the occurence frequency of $SO_2$ concentration were studied with the observed data in Seoul and the scheme that is capable of estimating not only highest concentration for a variety of averaging times but also concentrations for arbitary occurrence frequency with long term arithmatic mean and geometric standard deviation data, was evaluated. The results of the statistical analysis show that the occurrence frequency is almost log normal except a few cases, and 3rd highest values of daily mean concentration were about 4.2 $\sim$ 5.2 times higher than annual arithmatic mean. The evaluation with the observed hourly concentration shows that the scheme fairly well estimate the short concentration of arbitary occurrence frequence and it can be used for air quality management and environmental impact assessment.

  • PDF

Concentrations of Air Pollutants Measured at Kosan during ACE-Asia Intensive Observation Period (ACE-Asia 집중관측기간에 제주고산에서 측정한 대기오염물질의 농도 분포특성)

  • ;;;;Jianzhen Yu;Keith Bower
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.487-501
    • /
    • 2002
  • The concentrations of gaseous (NO$_{x}$, SO$_2$, and $O_3$) and particulate (Elemental Carbon, EC and Organic Carbon, OC) pollutants were measured to evaluate the air quality of Kosan. Samples were taken at Kosan during ACE-Asia (Asian Pacific Regional Aerosol Characterization Experiment) IOP (Intensive Observation Period) (2001. 3. 21~2001. 5. 5). The mean concentrations of $O_3$(46.3$\pm$10.4 ppb) is higher than those at urban area such as Seoul and Busan in Korea. On the other hand, the mean concentrations of other gaseous species, NO$_{x}$(4.73$\pm$3.42 ppb) and SO$_2$(0.62$\pm$0.63 ppb) are lower than those at great cities. So we concluded that there are a few primary sources emitting atmospheric pollutants. The concentration of EC is higher and the concentration of OC is similar with or higher than those at other background sites. The recent EC concentration is higher than those measured before at Kosan. We concluded that there are more primary sources than other background sites and the amount of primary source have increased recently in Jeju. Backward trajectory and co..elation analysis were used to study where the air masses originated and distinguish the source of pollutants. While NO$_{x}$ and $O_3$ were mainly emitted and formed from Jeju inland area, concentrations of SO$_2$, OC and EC were affected by Asian Dust from China. Using the mean relative standard deviation of ozone, cleanness coefficient was obtained. The cleanness coefficient value, is 1.6 times larger than the value in 1992. Recently, the air quality of Kosan has been contaminated because of the Asian Dust events since spring and the rapid industrialization development.pment.