• Title/Summary/Keyword: $SF_6$ analysis

Search Result 280, Processing Time 0.029 seconds

Characteristics of High-viscosity Grouting Materials for Rock Joint Reinforcement of Deep Tunnel (대심도 터널 암반 절리 보강을 위한 고점도 그라우팅 재료의 특성)

  • Yoon, Inkook;Moon, Junho;Lee, Junsu;Kim, Younguk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.59-63
    • /
    • 2021
  • This study presented the characteristics and additive effects of the grout with mixing ratio for developing of high-efficiency grouting technology under high depth conditions. The laboratory investigation were conducted with Portland cement (OPC) and micro cement (S8000-E) including viscosity experiments, particle size analysis experiments, Gel-Time experiments and uniaxial compressive strength experiments. As a result of the viscosity experiment, it was shown that OPC is advantageous in terms of viscosity, but S8000-E is suitable when considering the passage of rock joint intervals through particle size analysis. The Gel-Time experiment shows that it is not that difficult with injection as a grout material even when silica fume (SF) was applied. The strength of the cured material is improved as increase in the content of silica fium (SF). Within the range of the study, the optimal mixing ratio obtained through various experiments is S8000-E, w/c=70%, silica fium (SF)=6%, and 7 days.

Analysis of the Maximum Electric Field for Changing Pressure using Breakdown Characteristic of $N_2+SF_6$, $N_2+CF_4$, $N_2$ Gases in a Cryogenic Environment (극저온 환경을 고려한 기압별 $N_2+SF_6$, $N_2+CF_4$, $N_2$가스의 절연파괴 전압 값을 이용한 최대전계 분석)

  • Oh, Seok-Ho;Lee, Sang-Hwa;Shin, Woo-Ju;Park, Tae-Gun;Seong, Jae-Kyu;Hwang, Jae-Sang;Lee, Bang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1548-1549
    • /
    • 2011
  • High voltage cryogenic insulation issues need to be addressed in order to promote the commercialization of high temperature superconducting (HTS) equipment. As a fundamental step in the development of the optimum bushings for HTS devices, the breakdown characteristics of liquid nitrogen mixed with liquefied insulating gases such as $N_2$, $SF_6$, and $CF_4$ have been investigated. In order to investigate the possibility of substituting $CF_4$ gas for $SF_6$ gas for the bushings of HTS electrical equipment, AC withstanding voltage tests have been performed. In this paper, finding the maximum electric field $E_{max}$ using utilization factor ${\eta}$. This result is applicable to developing the real scale HTS equipment of the design parameters.

  • PDF

The analysis of electrons drift velocity in $SF_6+O_2$ mixture gas by Boltzmann-Equation (볼츠만 방정식을 이용한 $SF_6+O_2$ 혼합가스의 전자이동속도)

  • Song, Byoung-Doo;Ha, Sung-Chul;Jeon, Byung-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.185-188
    • /
    • 2002
  • This paper describes the information for quantitative simulation of weakly ionized plasma. We should grasp the meaning of the plasma state condition to utilize engineering application and to understand materials of plasma state. In this paper, the drift velocity of electron in $SF_6+O_2$ mixture gas calculated for range E/N values l~900[Td] at the temperature is 300[$^{\circ}K$] and pressure is 1[Torr], using a set of electron collision cross sections determined by the authors and the values of drift velocity of electrons are obtained for TOF, PT, SST sampling method of Backward Prolongation by two term approximation Boltzmann equation method. It has also been used to predict swarm parameter using the values of cross section as input. The result of Boltzmann equation, the drift velocity of electrons, has been compared with pure $SF_6$, pure $O_2$ and mixture gas.

  • PDF

Development of Model Interrupter of 7.2kV $SF_6$ Gas Electromagnetic Contactor Using Rotary Arc Principle (7.2kV급 로타리아크식 $SF_6$가스 전자접촉기 소호부 개발연구)

  • Chang, K.C.;Shin, Y.J.;Park, K.P.;Chong, J.K.;Kim, J.K.;Kim, G.S.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.30-32
    • /
    • 1995
  • The model interrupters of $SF_6$ gas electromagnetic contactor whose ratings are the voltage of 7.2kV and the short circuit current of 4.0kA have been designed and manufactured on the basis of theoretical and computational analysis for its development. The eddy current analysis, the magnetic field analysis and the calculation of the rotational force on arcs have been conducted using FLUX2D package. The short circuit current interrupting tests have been conducted to the model interrupters using the simplified capacitive synthetic test circuit in KERI. The results show that the model interrupters have a sufficient interrupting capability and the new design concept is proper for a good interrupting performance.

  • PDF

Analysis of AC Breakdown Voltage accoding to epoxy thickness of Composite Insulation for Dry-Air/Epoxy under non-uniform electric field (불평등전계에서의 건조공기/에폭시 복합절연물의 에폭시 두께에 따른 AC 파괴전압 분석)

  • Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Jung, Hae-Eun;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.113-114
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

Analysis and Simulation of SF6 Tracer Experiments for Tracking the Pollutant Transport (오염물질 이동 추적을 위한 SF6 추적자 실험 분석과 모사 연구)

  • 김영성;조성호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.397-410
    • /
    • 1998
  • Tracer experiments were performed 4 times in December 1992 on the relatively flat terrain and nearby building area adjacent to the Taedok Science Town in Korea. Each experiment was continued for relatively short period of 1 or 2 hours with intermittent release of SF6 up to 2.07g/s at 10m height. Movement of tracer plume was tracked by a continuous tracer analyzer installed on an air monitoring van. Simulation with INPUFF was carried out to analyze and predict experiments. Measured profiles of tracer plume were narrow and sharp while predicted profiles by INPUFF were broad and slowly varied. Tracer plumes were detected at a short distance of 0.5 to 2.2 km mainly due to intermittent release and high value of lower detectable limit. Various experimental conditions were tested by INPUFF simulation in order to find desirable conditions. Higher wind speed and less variable wind direction could yield longer distance of plume tracking only when the lower detectable limit was sufficiently low. Distance of plume tracking was long and did not much depend on the lower detectable limit in stable atmospheric conditions.

  • PDF

Analysis of electron transport properties in $SF_6$+He mixtures gas used by MCS-BE (MCS-BE에 의한 $SF_6$+He 혼합기체의 전자수송특성 해석)

  • 서상현;하성철;유희영;김상남;송병두
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.159-162
    • /
    • 1998
  • This paper describes the electron transport characteristics in $SF_6$+He gas calculated for range of E/N values from 50~700[Td] by the Monte Carlo simulation and Boltzrnann equation method using a set of electmn collision cross sections determined by the authors and the values of electron swarm parameters are obtained by M F method. The results gained that the values of the electron swarm parameters such as the electron drift velocity, the electron ionization or attachment coefficents, longitudinal and h-ansverse diffusion coefficients agree with the experimental and theoretical for a range of E/N.

  • PDF

Analysis of AC Breakdown Voltage of Composite Insulation for Dry-Air/Epoxy (건조공기/에폭시 복합절연물의 AC 파괴전압 분석)

  • Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Jung, Hae-Eun;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.289-290
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

A study of Dielectric Strength of Spacer for Tap Changer in a $SF^6 $ Gas Insulated Transformer ($SF^6 $ 가스변압기의 탭절환기용 스페이서의 절연내력에 관한 연구)

  • Heo, U-Haeng;Ha, Yeong-Sik;Hong, Jeong-Gyun;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.11
    • /
    • pp.556-562
    • /
    • 2001
  • Spacer is used between main tank and auxiliary tank for on load tap changer in gas insulated power transformer. This paper deals with electrical design of spacer and discusses different analysis method of between 2D FEM(finite element method) and 3D FEM. To design spacer, we modeled structure of two kind of coaxial cylinders of spacer conductors and analysised electric field of spacer at impulse and induced test voltage condition. Spacer has 13 conductors and electric field was changed according to arrangement of conductors. We could find out arrangement of conductors at which electric stress is minimum. And this arrangement was satisfied with actual test conditions.

  • PDF

Prebreakdown Avalanche Pulses in Compressed SF6 under Uniform Field (평등전계에서 압축 SF6가스의 절연파괴 선구 애벌렌체의 전류 펄스)

    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.3
    • /
    • pp.106-111
    • /
    • 1984
  • Prebreakdown current pulses arising from avalanche growth in SF6 were recorded under static uniform field at pressures up to about 400kpa. At pressures less than 100kpa the current pulses consist of the electron component observed as the fast rise of current, the negative ioncomponent which is superimposed, and the positive ion component comprising the tail of the pulse. The values of positive ion drift velocity were measured from the present pulse data. At pressures in excess of about 100 Kpa the pulse shapes becam distorted such that quantitative analysis was no longer possible, and did not indicate the action of any photosecondary process at the cathode. Breakdown appers to result from the seperate development of single avalanche.