• Title/Summary/Keyword: $SF_{6}$ Gas Gap

Search Result 66, Processing Time 0.027 seconds

Impulse Breakdown Characteristics of Nonuniform Field Gap in SF_6-N_2 Mixtures ($SF_6-N_2$혼합기체 중에서 불평등전계 갭의 임펄스 절연파괴 특성)

  • Lee, Bok-Hee;Lee, Kyoung-Ok;Kim, Jung-Il
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.9
    • /
    • pp.533-540
    • /
    • 2000
  • Lightning impulse $(1.2/44[\mus])$ and damped oscillating impulse $(Osc./44[\mus])$ : 0.83[MHz]) breakdown characteristics in sulphur-hexafluoride/nitrogen (SF6-N2) mixtures were investigated. The predischarge currents were observed to clarify the breakdown mechanism. th experiments were carried out under nonuniform electric fields disturbed by a needle-shaped protrusion whose length and diameter are 10[mm] and 1[mm] at total gas pressure up to 0.5[MPa] with nitrogen concentrations varying from 5 to 20[%] in the mixture. The electrical breakdowns of SF6-N2 mixtures for both the positive and negative polarities develop with steplike pulses in leader mechanism and the breakdown voltage -time (V-t) characteristics were affected by the space charge. The voltage-time curves for the negative oscillating impulse voltage were extended over the longer time range. The minimum breakdown voltages for the negative lightning and oscillating impulse voltage were higher than those for the positive ones. in particular the positive breakdown voltages were independent of the gas pressure.

  • PDF

V-t Characteristics and 50% Flash-over Voltage of $SF_{6}-N_{2}$ Mixtures for Lightening Impulse Voltage ($SF_{6}-N_{2}$ 혼합가스에서 뇌충격전압에 의한 50[50%] Flash over 전압 및 V-t 특성)

  • 김정달;송원표;김동의
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.1
    • /
    • pp.21-29
    • /
    • 1993
  • In this paper, we studied the 50% flashover voltage of lightening impulse which affect the most serious damages on the insulation of the electric power network system. Also its V -t characteristics and corona process phenomena of pure $SF_6, N_2, SF_6-N_2$mixtures under the circumstances of nonuniform field gap are researched. Comparing the characteristics of pure $SF_6$ with that of $SF_6, N_2$mixtures, we discussed that breakdown processes and $SF_6, N_2$ mixture's application to economics.As a results, 50% flashover voltage of $SF_6$ 50% - $N_2$ 50% for impulse voltage is higher then that of 80% of pure SF6, measured data and calculated data by equal area law are almost equal from the points of view of V-t characteristics. Therefore, it has been known that $SF_6$ 50% - $N_2$ 50% mixtures can be used as an economic constitution gas of pure $SF_6$, it is verified that corona processes from Lichtenberg figure.

  • PDF

Characteristics of Partial Discharge Under HVDC in SF6 Gas (SF6 가스 중 직류 고전압 하에서 부분방전 특성)

  • Kim, Min-Su;Kim, Sun-Jae;Jeong, Gi-Woo;Jo, Hyang-Eun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.4
    • /
    • pp.238-243
    • /
    • 2014
  • This paper dealt with the measurement and analysis of partial discharge (PD) under high voltage direct current (HVDC) in SF6 gas. Electrode systems such as a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack on epoxy plate and a free particle (FP) were fabricated to simulate the insulation defects. The analysis system was designed with a Time-Frequency (T-F) map algorithm programed based on LabVIEW. This can arrange the acquired PD pulses into frequency and time domain. A HVDC power source is composed of a transformer (220 V/50 kV), a diode (100 kV) and a capacitor (50 kV, 0.5 ${\mu}F$). The gap between the electrodes is 3 mm, and the $SF_6$ gas was set at 5 bar. PD pulses were detected by a 50 ${\Omega}$ non-inductive resistor. In the analysis, PD pulses were distributed below 0.5 MHz and 20 ns ~ 35 ns for the POC, 0.7 MHz ~ 1.7 MHz, below 0.6 MHz and 10 ns ~ 40 ns and 60 ns ~125 ns for the POE, below 0.1 MHz and 135 ns ~ 215 ns for the crack, and below 1.6 MHz and 250 ns for the FP.

Influence of Conducting Particle on the Breakdown Phenomena of $SF_6$ gas in Gas Insulated System ([$SF_6$] 가스 절연기기내에 도전성 금속이물 존재시 섬락전압에 미치는 영향)

  • Lee, B.W.;Ham, G.H.;Kim, I.S.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1687-1689
    • /
    • 1998
  • In this work, the behaviours of conducting wire type particles within the coaxial electrode gap energized with high ac voltage have been systematically investigated using charge simulation method. For this, spheroidal charge is adopted as a image charge for the CSM analysis in order to calculate the acquired charge of the particles which are erected on the surface of the outer electrode. For this purpose, the effects of the lengths and diameters of Cu, Al particles in gas insulated system have been studied by a numerical computation and particle lifting voltage, lifting field, breakdown voltage, acquired charge and travelling distance have been considered. From this, we understand that the particle behaviours have different characteristics according to the particle lengths and diameters. And a possible countermeasure, based on the proposed simulation, has been provided with a view to estimating the flashover voltage of $SF_6$ gas under the 1 atm.

  • PDF

The partial discharge and breakdown phenomena due to metallic particle in $SF_6$ gas chamber ($SF_6$ 가스챔버내 금속이물에 대한 부분방전 및 절연파괴 현상)

  • 이재걸;곽희로;조국희;박중신
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.75-81
    • /
    • 2000
  • This paper describes the partial discharge due to particles in $SF_6$ gas. A model GIS chamber was designed and manufactured. The partial discharge and breakdown phenomena due to the particles between electrodes were observed and partial discharge signals were detected, using an ultrasonic sensor. The analysis of the electric field by the states of the particle inserted between the electrodes, were also carried out. The partial discharge was observed at end while the particle was moving in $SF_6$ gas. The partial discharge in micro-gap grows to arc, and after all, it can cause a breakdown.The electric field strength was the highest in case that the particle was vertically attached on the conductor, and the lowest in case that it was horizontally attached on the enclosure.

  • PDF

A study on the repeated breakdown field strength of compressed $SF_{6}$ in uniform field perturbed by protrusion (교란된 평등전계에서 고기압 $SF_{6}$ 가스의 연속절연 파괴강도에 관한 연구)

  • 이동인
    • 전기의세계
    • /
    • v.29 no.2
    • /
    • pp.129-132
    • /
    • 1980
  • For large gas-insulated systems, the conductor utilized possess some degree of surface roughness which locally enhances the applied field at highpressure in $SF_{6}$. In order to investigate the effect of field enhancement on the breakdown field strength, the spheric protrusion was employed which gives a quantitative analysis on field enhancement. For further investigations on the breakdown level and polarity effect in $SF_{6}$, the repeated breakdown tests were performed with d.c. voltage at pressures up to about 4 bar. The experimental results show that the breakdown level does vary noticeably due to successive voltage applications and the breakdown field strength measured for a test gap with the cathode protrusion is markedly lower than that determined from the identical anode protrusion.

  • PDF

The Insulation Evaluation of N2:O2 Mixture Gas

  • Lee, Sang-Ho;Choi, Eun-Hyeok;Lim, Dong-Young;Park, Kwang-Seo;Kim, Se-Dong;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.7
    • /
    • pp.41-46
    • /
    • 2010
  • With the improvement of industrial society, high quality electrical energy, simplification of operation and maintenance, and ensuring reliability are being required. Also we request an urgent change from $SF_6$ gas to an environment-friendly gas insulation material. In this paper, the experiments of breakdown characteristics by pressure and gap change of $N_2/O_2$ mixture gas through a GIS (Gas Insulated Switchgear) model were described. This paper reviews basic data of the surface discharge characteristics for Teflon resin in not only pure $N_2$, $N_2:O_2$ mixture gas as being focused on environmentally-friendly insulating gas, but also $SF_6$. Also, insulation characteristics by breakdown voltage and surface discharge voltage of $N_2:O_2$ mixture gas in the experimental chamber were studied.

characteristic of breakdown voltage of electrode gap in vacuum (진공에서 극간 gap에 따른 절연파괴 전압 특성 파악)

  • Yoon, Jae-Hun;Kim, Byung-Chul;Lee, Sueng-Su;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.366-367
    • /
    • 2008
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of vacuum with air are studied in non-uniform field. The gap of needle to plane was 0.5mm, 0.8mm. The pressure of vacuum the range of 10^-4-10^-5torr. The diameter of a plane made of the stainless steel is150mm. As a result of the experiment, the breakdown voltage is increased about electrode gap distance increased. The electrode material influenced breakdown voltage in vacuum.

  • PDF

Measurement of the negative ion mobility of $SF_6$ gas ($SF_6$ 기체중에서의 음이온 이동도 측정)

  • Baek, Y.H.;Kim, J.S.;Bae, S.D.;Koo, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.249-251
    • /
    • 1988
  • In this paper, the negative ion mobility of $SF_6$ is determined using as a negative ion detector the burst pulse which is triggered in a positive point-plane gap by electrons detached from negative ions near the anode point. The result obtained for the negative ion mobility for zero field at atmospheric pressure is $0.57cm^2v^{-1}s^{-1}$.

  • PDF

A Study on the Breakdown Mechanism of Compressed $SF_6$ by Polarity of a Protrusion on Electrode Surface (전극표면상 미소돌기의 극성에 의한 압축 $SF_6$ 개스의 절연파괴 Mechanism에 관한 연구)

  • 이동인;이광식;김인식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.9
    • /
    • pp.956-963
    • /
    • 1990
  • The general shapes of prebreakdown pulses in a discharge gap were calculated and the current pulses due to avalanche were detected in SF6 by changing the polarity of the protrusion placed on an electrode at pressures up to about 400 Kpa. The mathematical model of prebreakdown pulse development with a negative protrusion shows agreement with the observed pulses. No evidence of intense bursts of field-emitted electrons was observed. Breakdown probably results from a single avalanche developing to a critical size. However the calculated shape of prebreakdown current pulse does not agree with the observed pulses with a positive protrusion. The breakdown is preceded by multiple avalanche development at pressures less than about 200 Kpa. This observation has been interpreted as due to the formation of negative ions following photoionization in the gas which drift into the critical volume near a positive protrusion.

  • PDF