• 제목/요약/키워드: $SF_{6}$ Gas Gap

검색결과 66건 처리시간 0.025초

불평등전계중에서 임펄스전압에 대한 $SF_6$ 기체의 전구방전과정의 분석 (Analysis of Predischarge Processes of $SF_6$ Gas Stressed by lmpulse Voltages under Nonuniform Electric Field)

  • 이복희;이경옥;이창준;백승권
    • 한국전기전자재료학회논문지
    • /
    • 제13권1호
    • /
    • pp.85-93
    • /
    • 2000
  • In this paper, the predischarge propagation processes of SF\ulcorner gas stressed by impulse voltages under nonuniform electric field perturbed by a needle protrusion are described. The statistical and formative time-lags and the time interval between leader pulses were investigated on the basis of the predischarge current measured in the gas pressure range of 0.1~0.5 MPa. The predischarge current is closely related to the waveform, amplitude and polarity of applied votages, the gas pressure and the gap geometry. Both the positive and negative predischarge processes in nonuniform electric field develop in a regime of stepwise leader propagation leading to electrical breakdown. The mean of the time interval between leader pulses gives about a factor of 10 higher for the negative than for the positive leader current puls-es. According as the gas pressure increases, the statistical time-lag was almost unchangeable, but the formative time-lag was gradually decreased.

  • PDF

초고압 $SF_6$가스중의 선구방전기구 (Precursor Discharge Mechanism under EHV in $SF_6$ Gas)

  • 이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1807-1809
    • /
    • 1996
  • The axial discharge at switching operations of EHV $SF_6$ disconnector can lead to the breakdown to the enclosure. Precursor in periphery zone leads to formation of leader over some time delay. Injected charge value depends on electric field and gap geometry. The calculation method for parameters of $SF_6$ insulation for DS in EHV-GIS is suggested by using the new criterion of leader inception in connection with periphery field nearby the boundary of streamer zone.

  • PDF

침전극 가공상태에 따른 혼합가스의 절연특성에 관한 실험 (Experiment on the Polish Condition of Needle Electrode on the Insulation Properties of Gas Mixtures)

  • 고연성;여동구;서호준;이동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.339-340
    • /
    • 2006
  • AC spark discharge voltage of SF6/CO2and SF6/N2 containing various mixed rate in volume percent (1, 5 and 10%) of SF6 in non-uniform fields are investigated. The needle to plane electrode gap spacing was 5 and 10 mm, and the gas pressure was varied within the range of 0.1~0.7 MPa. We have observed a N-characteristic typical for the electronegative gases even in gas mixtures of 1% SF6 with CO2 and N2 as buffer gases. Especially, the materials of the needle electrode affect the insulation properties of the gas mixtures drastically. On the contrary to the case of needle electrodes made by mild steel or high carbon steel, the N-characteristics are hardly perceived in the case of stainless steel needle in this experiment.

  • PDF

불평등 전계에서 $SF_6/N_2$의 초고압 AC전압 절연내력 시뮬레이션

  • 허창수;이병택;최순호;심명섭;안정식;황청호;장용무
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.37-37
    • /
    • 2010
  • In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/N_2$ mixtures. In this paper, breakdown experiment values and breakdown simulation value are compared. Streamer theory was used for predicting breakdown voltage. For accurate simulation, this simulation apply utilization factor using CST program. AC breakdown experiments in non-uniform field was performed to compare with the breakdown simulation values. But with gap lengths increasing, the breakdown voltage is saturated. So simulation need surface roughness factor.

  • PDF

평등전계에서 AC 및 표준 뇌 임펄스 전압의 $SF_6/CF_4$ 혼합 가스 절연 파괴 특성 (Breakdown Characteristics of $SF_6/CF_4$ Mixtures Under AC and Standard Lightning Impulse Voltages in Uniform Field)

  • 성허경;박신우;황청호;김남렬;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.227-228
    • /
    • 2007
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of SFJCF4 mixtures in uniform field was performed. The experiments were carried out under AC and standard lightning impulse (SLI) voltages. The sphere-sphere electrode whose gap distance was 1 mm was used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.4 MPa. The results show that addition of $SF_6$ to $CF_4$ increase AC and SLI breakdown voltages. Under AC voltages the breakdown voltages of each mixture were linearly increased according to the quantity of $SF_6$. However under SLI voltages the breakdown voltages of each mixture were similar.

  • PDF

고기압하에서 $SF_{6}$ 혼합 가스 ($SF_{6}$/$N_{2}$)의 절연파괴에 대한 연구 (A study on the electrical breakdown in pressurized ($SF_{6}$/$N_{2}$) mixtures)

  • 이동인;이달해
    • 전기의세계
    • /
    • 제28권4호
    • /
    • pp.39-46
    • /
    • 1979
  • The effective ionization coefficient in $SF_{6}$/$N_{2}$ mixtures was attempted to derive from the pure gases. Measurements of static breakdown voltage were made under the uniform field at pressures up to 4 bar in order to compare with the results obtained from this assumption. The relative performance of $SF_{6}$/$N_{2}$ mixtures to pure $SF_{6}$ was also investigated. The effect of surface roughness on discharge thresholds in $SF_{6}$/$N_{2}$ mixtures was calculated employing the simplified model and mesurements of breakdown voltages for a gap with an artificial protrustion were also made. The experimental results show that the effective ionization coefficient in gas mixtures can not be reliably estimated from the values measured for the pure gases. Therefore, basic parameters for $SF_{6}$/$N_{2}$ mixtures must be measured by investigation of the mixtures themselves. The relative performance of mixtures to pure $SF_{6}$ could be considered with the values of pR.

  • PDF

SF(sub)6-$N_2$혼합가스중에 뇌임펄스전압에 의해 형성된 불평등전장에서의 전구방전현상 (Predischarge Phenomena in Nonuniform Fields Caused by Lightning Impulse Voltages in SF(sub)6-$N_2$Mixtures)

  • 이복희;이경옥;백승권
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권6호
    • /
    • pp.288-295
    • /
    • 2001
  • Predischarges in nonuniform electric field stressed by lightning impulse voltagesin SF(sub)6-$N_2$mixtures are initiated by streamer coronas. Due to field ehnancement at a protrusion point of electrodes new ionization processes occur and a precursor, which leads to a first leader, is created. The leader proceeds step by step to the opposite electrode and the final jump bridges the test gap. It was found that the predischarge is propagated with a leader mechanism of stepwise expansion from the predischarge current waveforms measured by a shunt. The predischarge current is closely related to the amplitude and polarity of applied voltages, the gas pressure and the gap geometry. The time intervals between step leaders for the positive and negative polarities were inversely proportional to V.P$^2$. When the gas pressure increases in the positive polarity, statistical time lag to statistical time lag to streamer corona inception increase slightly, but the formative time lag to flashover is significantly decreased.

  • PDF

$SF_6$ 가스중 V-t절연파괴특성 (Voltage Time characteristic of electrical breakdown in $SF_6$)

  • 서길수;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1770-1772
    • /
    • 1997
  • In this paper, Voltage-time characteristics of lightning impulse and switching surge breakdown in SF6 is studied on the gap and various pressure. The characteristics is categorized into three pattern depending on the configuration of the gap and gas pressure. The properties of the voltage-time characteristics in these patterns are generalized as semi-empirical formula which will be useful in the quantitation voltage evaluation of insulation coordination and the abnormal voltage protection of SF6 insulated power equipment.

  • PDF

불평등 전계에서 SF6/N2 혼합가스의 AC 절연파괴전압 시뮬레이션 및 실험값와의 비교 (AC Breakdown Voltage Simulation of SF6/N2 Mixture in Non-Uniform Field and Its Comparison with Experimental Values)

  • 이병택;황청호;이태호;허창수;장용무
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1416-1422
    • /
    • 2010
  • $SF_6$ is the most commonly used insulating gas in electrical systems. But In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/N_2$ mixtures. At present study the breakdown characteristics of $SF_6/N_2$ mixtures in Non-uniform field was performed. In this paper, The simulation value are compared with experiment values. Streamer breakdown criterion was used for predicting breakdown voltage. For accurate simulation this simulation apply utilization factor using CST(computer simulation technology) EM $studio^{tm}$ program. AC breakdown experiments in non-uniform field was performed to compare with the breakdown simulation values. The pressure range of gas mixtures was 0.4 MPa to 0.7 MPa. The rod-plane was used and mixture ratio is $SF_6$ 20% : $N_2$ 80%. The gap lengths are 10mm to 70mm. As the pressure increase, this simulation value does not correspond to the experiment value. So this simulation need surface roughness factor. As a result of applying surface roughness factor this simulation decrease a relative error (|experiment value - simulation value| /simulation value).

$SF_6$GIS용 스페이서 표면 파티클에 의한 절연파괴 특성 (The Particle-Initiated Breakdown Characteristics on the Spacer Surface for $SF_6$GIS)

  • 김정달;이세훈
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.3-11
    • /
    • 1998
  • 스페이서 표면 파티클에 의한 오염의 영향은 SF6GIS의 절연내력을 현저히 감소시킨다. 이와 관련해서 우리는 평행평판전극 구성으로 SF6가스중에서 금속 및 비금속 파티클의 위치 및 형태를 변화시키면서 교류전압에서 섬락전압 특성과 파괴 기구에 대해서 연구했다. 주된 결과는 $\circled1$파티클 위치에 대한 섬락전압 감소의 영향은 갭중간에서 가장 적고 전극에서 미소간극 분리된 경우의 영향이 가장 커다. $\circled2$ 섬락전압 감소가 크게 되는 금속 파티클 일수록 FOV 포화 현상은 낮은 압력 영역으로 이동된다. $\circled3$0.6[mm]이하의 비금속 파타클은 섬락전압에 그의 영향을 미치지 않는다.

  • PDF