• Title/Summary/Keyword: $O_2$ sensor

Search Result 1,271, Processing Time 0.026 seconds

Effect of Ni Interlayer on the Methanol Gas Sensitivity of ITO Thin Films

  • Lee, Y.J.;Huh, S.B.;Lee, H.M.;Shin, C.H.;Jeong, C.W.;Chae, J.H.;Kim, Y.S.;Kim, Daeil
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.5
    • /
    • pp.245-248
    • /
    • 2010
  • Sn doped $In_2O_3$ (ITO) and ITO/Ni/ITO (INI) multilayer films were deposited on the glass substrates with a reactive magnetron sputtering system without intentional substrate heating and then the influence of the Ni interlayer on the methanol gas sensitivity of ITO and INI film sensors were investigated. Although both ITO and INI film sensors have the same thickness of 100 nm, INI sensors have a sandwich structure of ITO 50 nm/Ni 5 nm/ITO 45 nm. The changes in the gas sensitivity of the film sensors caused by methanol gas ranging from 100 to 1000 ppm were measured. It is observed that the INI film sensors show the higher sensitivity than that of the ITO single layer sensors. Finally, it can be concluded that the INI film sensor have the potential to be used as improved methanol gas sensors.

Causality join query processing for data stream by spatio-temporal sliding window (시공간 슬라이딩윈도우기법을 이용한 데이터스트림의 인과관계 결합질의처리방법)

  • Kwon, O-Je;Li, Ki-Joune
    • Spatial Information Research
    • /
    • v.16 no.2
    • /
    • pp.219-236
    • /
    • 2008
  • Data stream collected from sensors contain a large amount of useful information including causality relationships. The causality join query for data stream is to retrieve a set of pairs (cause, effect) from streams of data. A part of causality pairs may however be lost from the query result, due to the delay from sensors to a data stream management system, and the limited size of sliding windows. In this paper, we first investigate spatial, temporal, and spatio-temporal aspects of the causality join query for data stream. Second, we propose several strategies for sliding window management based on these observations. The accuracy of the proposed strategies is studied by intensive experiments, and the result shows that we improve the accuracy of causality join query in data stream from simple FIFO strategy.

  • PDF

Simultaneous Diagnostic Assay of Catechol and Caffeine Using an in vivo Implanted Neuro Sensor

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Young-Sam;Kwon, O-Min;Lee, Ji-Eun;Baek, Seung-Min;Kwak, Kyu-Ju
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.9
    • /
    • pp.1742-1746
    • /
    • 2008
  • Catechol and caffeine were simultaneously analyzed with a bismuth-immobilized carbon nanotube paste electrode (BPE) using square wave (SW) stripping voltammetry. Optimum analytical conditions were determined. Simultaneous working ranges of 100-1,500 $mgL^{-1}$ for caffeine and 5-75 $mgL^{-1}$ for catechol were obtained. In the separated cell systems, a working range of 0.1-2.1 $mgL^{-1}$ catechol with a correlation coefficient of 0.9935, and a working range of 10-210 $mgL^{-1}$ caffeine with a correlation coefficient of 0.9921 were obtained. A detection limit (S/N) of 0.15 $mgL^{-1}$ (7.7 ${\times}$ $10^{-7}$ M) and a detection limit of 0.02 $mgL^{-1}$ (1.82 ${\times}$ $10^{-7}$ M), respectively, manifested for catechol and caffeine. It was found that three macro-type electrode systems could be implanted in fish and rat neuro cells. For both ions, the ion currents were observed. The physiological impulse conditions and the neuronal thinking current were also obtained.

Micro humidity sensor with poly imide sensitive layer (폴리이미드를 감지막으로 한 마이크로 정전용량형 습도센서)

  • Shin, P.K.;Cho, K.S.;Park, G.B.;Yuk, J.H.;Park, J.K.;Im, H.C.;Ji, S.H.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1898-1899
    • /
    • 2005
  • 반도체 집적회로 공정에서 사용되는 폴리이미드 포토레지스트(P12723, Dupont)를 감습막으로 사용하는 마이크로 습도센서 소자를 제작하였다. 마이크로 습도센서는 실리콘 웨이퍼 기판 위에 $SiO_2$ 박막을 건식열산화 공정으로 제작하고, Al 박막을 포토리소그라피 공정으로 패터닝 한 IDT (Interdigital Transducer)를 전극 위에 폴리이미드 포토레지스트를 공정변수를 다양하게 조절하면서 감습막으로 제작하였다. 폴리이미드 감습막은 스핀코팅법으로 제작하였으며, 회전수를 조절하여 두께를 변화시켰다. 완성된 마이크로 습도센서 소자의 상대습도 변화$(10{\sim}90% RH)$에 따른 정전용량 값 변화를 항온항습조 내에서 다양한 온도에서 HP4192A Impedance Analyzer를 사용하여 조사함으로써, 폴리이미드 포토레지스트를 사용하는 마이크로 정전용량형 습도센서의 제작 가능성을 검토하였다. 폴리이미드 정전용량형 마이크로 습도센서는 다양한 인가 전원 주파수에서 기준 센서로 사용된 상용 Vaisala Hygrometer와 유사한 감습특성 및 응답특성을 보였다.

  • PDF

The Implementation of Graph-based SLAM Using General Graph Optimization (일반 그래프 최적화를 활용한 그래프 기반 SLAM 구현)

  • Ko, Nak-Yong;Chung, Jun-Hyuk;Jeong, Da-Bin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.637-644
    • /
    • 2019
  • This paper describes an implementation of a graph-based simultaneous localization and mapping(SLAM) method called the General Graph Optimization. The General Graph Optimization formulates the SLAM problem using nodes and edges. The nodes represent the location and attitude of a robot in time sequence, and the edge between the nodes depict the constraint between the nodes. The constraints are imposed by sensor measurements. The General Graph Optimization solves the problem by optimizing the performance index determined by the constraints. The implementation is verified using the measurement data sets which are open for test of various SLAM methods.

Fabrication of Planar Multi-junction Thermal Converter (평면형 다중접합 열전변환기의 제작)

  • Kwon, Sung-Won;Park, S.I.;Cho, Y.M.;Kang, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.17-24
    • /
    • 1996
  • Planar multi-junction thermal converters were fabricated for precise measurements of the ac voltage and current by an ac-dc transfer method. A heater and a thermocouple array were fabricated onto a sandwiched membrane, $Si_{3}N_{4}$ (200 nm) / $SiO_{2}$ (400 nm) / $Si_{3}N_{4}$ (200 nm), a thickness of $0.8\;{\mu}m$ and a size of $2{\times}4\;mm^{2}$, which is supported by a surrounding frame. The NiCr heater is located at the center of the membrane vertically. Hot junctions of $48{\sim}156$ pairs of thermocouples (Cu-CuNi44) are located near or onto the heater, and cold junctions are located onto the silicon frame. Output of the thermal converters for 10 mA dc input was $76\;mV{\sim}382\;mV$ dependent on a model, and short term stability of the outputs was ${\pm}5{\sim}15\;ppm$/ 10 min with 5 mA dc input. Responsivity in air was in the range of $3.9{\sim}14.5V/W$. Responsivity of the model BF48 in air which has 48 thermocouples was 2 times or greater than that of 3 dimensional multi-junction thermal converter in vacuum which has 56 thermocouples. AC-DC transfer differences with an input of 10 mA or less were less than ${\pm}1\;ppm$ in the frequency range from 5 Hz to 2 kHz, and about $2{\sim}3\;ppm$ at 5 kHz and 10 kHz.

  • PDF

A study on electrical response property of photoconductor film for x-ray imaging sensor (X선 영상센서 적용을 위한 광도전체 필름의 전기적 응답특성 연구)

  • Kang, Sang-Sik;Kim, Chan-Wook;Lee, Mi-Hyun;Lee, Kwang-Ok;Moon, Yong-Soo;An, Sung-A;No, Ci-Chul;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.29-33
    • /
    • 2009
  • Recently, the compound materials(a-Se, $HgI_2$, PbO, CdTe, $PbI_2$, etc.) that are used in flat panel x-ray imager have been studied for digital x-ray imaging. In this paper, the signal detection properties of $HgI_2$ and a-Se conversion layer, are compared. The thick $HgI_2$ film is fabricated by special particle-in-binder method and the conventional vacuum thermal evaporation is used for a deposition of a-Se film. And an electrical characteristic measurements were investigated about leakage current, signal response property and x-ray sensitivity. From the experimental results show that the $HgI_2$ film has a low operation voltage and high signal generation than that of a-Se.

  • PDF

Estimation of Korean Paddy Field Soil Properties Using Optical Reflectance (광반사를 이용한 한국 논 토양 특성 추정)

  • Chung, Sun-Ok;Jung, Ki-Youl;Sudduth, Kenneth A.
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.33-39
    • /
    • 2011
  • An optical sensing approach based on diffuse reflectance has shown potential for rapid and reliable on-site estimation of soil properties. Important sensing ranges and the resulting regression models useful for soil property estimation have been reported. In this study, a similar approach was applied to investigate the potential of reflectance sensing in estimating soil properties for Korean paddy fields. Soil cores up to a 65-cm depth were collected from 42 paddy fields representing 14 distinct soil series that account for 74% of the total Korean paddy field area. These were analyzed in the laboratory for several important physical and chemical properties. Using air-dried, sieved soil samples, reflectance data were obtained from 350 to 2500 nm on a 3 nm sampling interval with a laboratory spectrometer. Calibrations were developed using partial least squares (PLS) regression, and wavelength bands important for estimating the measured soil properties were identified. PLS regression provided good estimations of Mg ($R^2$ = 0.80), Ca ($R^2$ = 0.77), and total C ($R^2$ = 0.92); fair estimations of pH, EC, $P_2O_5$, K, Na, sand, silt, and clay ($R^2$ = 0.59 to 0.72); and poor estimation of total N. Many wavelengths selected for estimation of the soil properties were identical or similar for multiple soil properties. More important wavelengths were selected in the visible-short NIR range (350-1000 nm) and the long NIR range (1800-2500 nm) than in the intermediate NIR range (1000-1800 nm). These results will be useful for design and application of in-situ close range sensors for paddy field soil properties.

3D Brain-Endoscopy Using VRML and 2D CT images (VRML을 이용한 3차원 Brain-endoscopy와 2차원 단면 영상)

  • Kim, D.O.;Ahn, J.Y.;Lee, D.H.;Kim, N.K.;Kim, J.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.285-286
    • /
    • 1998
  • Virtual Brain-endoscopy is an effective method to detect lesion in brain. Brain is the most part of the human and is not easy part to operate so that reconstructing in 3D may be very helpful to doctors. In this paper, it is suggested that to increase the reliability, method of matching 3D object with the 2D CT slice. 3D Brain-endoscopy is reconstructed with 35 slices of 2D CT images. There is a plate in 3D brain-endoscopy so as to drag upward or downward to match the relevant 2D CT image. Relevant CT image guides the user to recognize the exact part he or she is investigating. VRML Script is used to make the change in images and PlaneSensor node is used to transmit the y coordinate value with the CT image. The result is test on the PC which has the following spec. 400MHz Clock-speed, 512MB ram, and FireGL 3000 3D accelerator is set up. The VRML file size is 3.83MB. There was no delay in controlling the 3D world and no collision in changing the CT images. This brain-endoscopy can be also put to practical use on medical education through internet.

  • PDF

Sensitive Characteristics of Hot Carriers by Bias Stress in Hydrogenated n-chnnel Poly-silicon TFT (수소 처리시킨 N-채널 다결정 실리콘 TFT에서 스트레스인가에 의한 핫캐리어의 감지 특성)

  • Lee, Jong-Kuk;Lee, Yong-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.218-224
    • /
    • 2003
  • The devices of n-channel poly silicon thin film transistors(TFTs) hydrogenated by plasma, $H_2$ and $H_2$/plasma processes are fabricated. The carriers sensitivity characteristics are analyzed with voltage bias stress at the gate oxide. The parametric sensitivity characteristics caused by electrical stress conditions in hydrogenated devices are investigated by measuring the drain current, threshold voltage($V_{th}$), subthreshold slope(S) and maximum transconductance($G_m$) values. As a analyzed results, the degradation characteristics in hydrogenated n-channel polysilicon thin film transistors are mainly caused by the enhancement of dangling bonds at the poly-Si/$SiO_2$ interface and the poly-Si grain boundary due to dissolution of Si-H bonds. The generation of traps in gate oxide are mainly dued to hot electrons injection into the gate oxide from the channel region.