• Title/Summary/Keyword: $NO_2$ sensor

Search Result 606, Processing Time 0.033 seconds

Rapid Nutrient Diagnosis of Cucumber by Test Strip and Chlorophyll Meter (Test Strip과 Chlorophyll Meter를 이용한 오이의 신속한 영양진단)

  • Kim, Kwon-Rae;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.5
    • /
    • pp.272-279
    • /
    • 2003
  • This study was performed to develop a more rapid and simple nutrient diagnosis method of plants than the conventional leaf analysis method. Cucumber (Cucumis sativus L. cv. jangil banbaek) was planted in the mixed media produced by mixing perlite and rock wool at 1:1 (v/v) ratio. The Yamazakki nutrient solution for cucumber was supplied to the media using micro-drip irrigation system. Experimental plots were consisted of no fertilization, deficient fertilization, adequate fertilization, and surplus fertilization for N, P and K. Specific color difference sensor value (SCDSV) measured by chlorophyll meter was closely related to total-N concentration in leaves measured by the conventional method. Nitrate, $PO_4$ and K concentration in petiole sap measured by test strips showed a significant relationship with total-N, P and K concentration in leaves. Linear regression equations between $NO_3$, $PO_4$ and K concentration in petiole sap and total-N, P and K concentration in the leaves were prepared. Optimum levels of $NO_{3}$, $PO_{4}$ and K in petiole sap were obtained by plugging the optimum concentrations of total-N, P and K in the leaves by other researchers into the equations. In conclusion, the SCDSV measured by chlorophyll meter and the concentration of $NO_3$, P and K in petiole sap measured by the test strips would be suitable for rapid estimation of plant nutrient status.

Analysis of the Optimal Location of Wearable Biosensor Arrays for Individual Combat System Considering Both Monitoring Accuracy and Operational Robustness (모니터링 정확도와 운용 강건성을 고려한 개인전투체계용 착용형 생체센서 어레이의 최적 위치 분석)

  • Ha, Seulki;Park, Sangheon;Lim, Hyeoncheol;Baek, Seung Ho;Kim, Do-Kyoung;Yoon, Sang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.287-297
    • /
    • 2019
  • Monitoring for the physiological state of a solider is essential to the realization of individual combat system. Despite all efforts over the last decades, there is no report to point out the optimal location of the wearable biosensors considering both monitoring accuracy and operational robustness. In response, we quantitatively measure body temperature and heartrate from 34 body parts using 2 kinds of biosensor arrays, each of which consists of a thermocouple(TC) sensor and either a photoplethysmography(PPG) sensor or an electrocardiography(ECG) sensor. The optimal location is determined by scoring each body part in terms of signal intensity, convenience in use, placement durability, and activity impedance. The measurement leads to finding the optimal location of wearable biosensor arrays. Thumb and chest are identified as best body parts for TC/PPG sensors and TC/ECG sensors, respectively. The findings will contribute to the successful development of individual combat system.

Drowsy Driving Detection Algorithm Using a Steering Angle Sensor And State of the Vehicle (조향각센서와 차량상태를 이용한 졸음운전 판단 알고리즘)

  • Moon, Byoung-Joon;Yeon, Kyu-Bong;Lee, Sun-Geol;Hong, Seung-Pyo;Nam, Sang-Yep;Kim, Dong-Han
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.30-39
    • /
    • 2012
  • An effective drowsy driver detection system is needed, because the probability of accident is high for drowsy driving and its severity is high at the time of accident. However, the drowsy driver detection system that uses bio-signals or vision is difficult to be utilized due to high cost. Thus, this paper proposes a drowsy driver detection algorithm by using steering angle sensor, which is attached to the most of vehicles at no additional cost, and vehicle information such as brake switch, throttle position signal, and vehicle speed. The proposed algorithm is based on jerk criterion, which is one of drowsy driver's steering patterns. In this paper, threshold value of each variable is presented and the proposed algorithm is evaluated by using acquired vehicle data from hardware in the loop simulation (HILS) through CAN communication and MATLAB program.

Fiber-Optic Sensor Using Bending-Sensitive Fiber (굽힘에 민감한 광섬유를 이용한 광섬유 센서)

  • Lee Dong ho;Kwon Kwang Hee;Lee Cherl hee;Song Jae Won;park Jae hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.10A
    • /
    • pp.1200-1204
    • /
    • 2004
  • Fiber-optic sensor (FOS) using bending-sensitive fiber (BSF which detects physical variables according to the variation of fiber-bending is proposed. BSF is already used in variable optical attenuator. Three-dimensional finite difference beam propagation method (3D FD-BPM) is used to investigate the bending loss of BSF. Then, the results of bending experiment with FOS consisting of BSF is compared to numerical results of 3D FD-BPM. In particular, the optical power of fabricated FOS with BSF varies from -ldB to -2OdB when pressure given to the upper side of FOS changes from 0 MPa to 0.005 MPa, while the FOS consists of SMF shows no change of optical power at the same condition.

Analysis of Potential on Measurement of SO2 and NO2 using Radiative Transfer Model and Hyperspectral Sensor (복사전달모델과 초분광센서를 이용한 아황산가스와 이산화질소의 농도 측정 가능성 분석)

  • Shin, Jung-il;Kim, Ik-Jae;Choi, Min-Jae;Lim, Seong-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.658-663
    • /
    • 2018
  • Current measuring methods for air quality are based on ground measurement networks and satellite data. New methods of collecting evidence with advanced sensors are needed because current methods have limitations in collecting evidence for the illegal emission of air pollutants at narrow areas or specific sites. This study analyzed the possibility of using an ultraviolet hyperspectral sensor to measure the concentration of nitrogen dioxide and sulfur dioxide. Two types of spectra were used: simulated spectra for gases with various concentrations using a radiative transfer model and observed spectra for each gas for a concentration. To understand the possibility of using a hyperspectral sensor, the differences between the simulated spectra and the observed spectra were analyzed, and the variation of simulated spectra were then analyzed according to the concentration. The results showed good agreement between observed spectra and simulated spectra. In addition, the absorption depth at specific wavelengths in the simulated spectra had a very strong correlation with the gas concentration. The gas concentration could be estimated using the hyperspectral sensor. In the future, validation would be needed to estimate the gas concentration through observations of various concentrations of gases using a hyperspectral sensor.

Effect of Plant Growth and Production of Tomato on the Water Content Control in Rockwool Culture (암면배지의 수분제어가 토마토의 생육 및 생산성에 미치는 영향)

  • Moon, Doo-Gyung;Kim, So-Hee;Cho, Myeng-Whan;Yu, In-Ho;Ryu, Hee-Ryong;Choi, Kyung-Hee;Kwon, Yong-Hee;Lee, So-Jin
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.2
    • /
    • pp.183-189
    • /
    • 2018
  • This study was carried out to investigate the effect of plant growth and production of tomato (Lycopersicon Esculentum Mill cv. Tefunis) according to the water content of non-recycled rockwool culture in high-rise tomato greenhouse. Daily irrigation amount was 3.8 times higher in the irrigation control by Integrated Solar Radiation (ISR) than in the Frequency Domain Reflectometry (FDR) sensor. Water content of ISR and FDR was 90-95 and 60-65%, respectively. Plant height and weight of tomato fruit was 1.2-1.9 times longer and 1.2-2.0 times heavier in the ISR than in the FDR sensor, respectively. No significantly differed to sugar content of tomato by treatments. Marketable fruits were the higher 1.3 times in the ISR compared with the FDR sensor. Cracking percentage in the ISR was also the higher 2.0 times compared with FDR sensor. Therefore, Irrigation control by ISR was appropriate to improve of plant growth and production of tomato with non-recycled rockwool culture in greenhouse during long-term cultivation.

Rapid Nutrient Diagnosis of Tomato by Test Strips and a Chlorophyll Meter (Test strip과 chlorophyll meter를 이용한 토마토의 신속한 영양진단)

  • Kim, Kwon-Rae;Jeoung, Han-Ul;Kim, Kye-Hoon
    • Applied Biological Chemistry
    • /
    • v.46 no.2
    • /
    • pp.140-143
    • /
    • 2003
  • This study was performed to develop a more rapid and simple nutrient diagnosis method of plants than the conventional leaf analysis method. tomato (Lycopersicon esculentum Mill. cv. super momotaro) was planted in the mixed media produced by mixing perlite and rock wool at 1 . 1 (v/v) ratio. The Yamazakki nutrient solutions for cucumber and tomato were supplied to the media using the micro-drip irrigation system. Experimental plots produced consisted of no fertilization, deficient fertilization, adequate fertilization and surplus fertilization for N, P and K, respectively. Each experimental plot was replicated four times. Specific color different sensor values (SCDSV) measured by the chlorophyll meter were closely related to total-N concentrations in the leaves measured by the conventional method. Nitrate, $PO_4$ and K concentrations in petiole sap measured by test strips #(Reflectoquant^{\circledR},\;Merck,\;Germany)$ showed a significant relationship with total-N, p and K concentrations in leaves. The linear regression equations between $NO_3,\;PO_4$ and K concentrations in petiole sap and total-N, p and K concentrations in the leaves were prepared. The optimum levels of $NO_3,\;PO_4$ and K in petiole sap were obtained by plugging the optimum concentrations of total-N, p and K in the leaves by other researchers into the equations. In conclusion, the SCDSV by the chlorophyll meter and concentrations of NO3, p and K in petiole sap measured by the test strips would be suitable for rapid estimation of plant nutrient status.

Hollow SnO2 Hemisphere Arrays for Nitric Oxide Gas Sensing

  • Hoang, Nhat Hieu;Nguyen, Minh Vuong;Kim, Dojin
    • Korean Journal of Materials Research
    • /
    • v.23 no.12
    • /
    • pp.667-671
    • /
    • 2013
  • We present an easy method of preparing two-dimensional (2D) periodic hollow tin oxide ($SnO_2$) hemisphere array gas sensors using polystyrene (PS) spheres as a template. The structures were fabricated by the sputter deposition of thin tin (Sn) metal over an array of PS spheres on a planar substrate followed by calcination at an elevated temperature to oxidize Sn to $SnO_2$ while removing the PS template cores. The $SnO_2$ hemisphere array structures were examined by scanning electron microscopy and X-ray diffraction. The structures were calcined at various temperatures and their sensing properties were examined with varying operation temperatures and concentrations of nitric oxide (NO) gas. Their gas-sensing properties were investigated by measuring the electrical resistances in air and the target gases. The measurements were conducted at different NO concentrations and substrate temperatures. A minimum detection limit of 30 ppb, showing a sensitivity of S = 1.6, was observed for NO gas at an operation temperature of $150^{\circ}C$ for a sample having an Sn metal layer thickness corresponding to 30 sec sputtering time and calcined at $600^{\circ}C$ for 2 hr in air. We proved that high porosity in a hollow $SnO_2$ hemisphere structure allows easy diffusion of the target gas molecules. The results confirm that a 2D hollow $SnO_2$ hemisphere array structure of micronmeter sizes can be a good structural morphology for high sensitivity gas sensors.

Magnetic Saturation Effect of the Iron Core in Current Transformers Under Lightning Flow

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.97-102
    • /
    • 2017
  • A current transformer (CT) is a type of sensor that consists of a combination of electric and magnetic circuits, and it measures large ac currents. When a large amount of current flows into the primary winding, the alternating magnetic flux in the iron core induces an electromotive force in the secondary winding. The characteristics of a CT are determined by the iron core design because the iron core is saturated above a certain magnetic flux density. In particular, when a large current, such as a current surge, is input into a CT, the iron core becomes saturated and the induced electromotive force in the secondary winding fluctuates severely. Under these conditions, the CT no longer functions as a sensor. In this study, the characteristics of the secondary winding were investigated using the time-difference finite element method when a current surge was provided as an input. The CT was modeled as a two-dimensional analysis object using constraints, and the saturation characteristics of the iron core were evaluated using the Newton-Rhapson method. The results of the calculation were compared with the experimental data. The results of this study will prove useful in the designs of the iron core and the windings of CTs.

Selective Unacknowledged Transmission in IEEE 802.15.4 Considering Energy Efficiency (IEEE 802.15.4에서 에너지 효율성을 고려한 선택적 Unacknowledged 전송)

  • Yang, Hyun;Park, Tan-Se;Park, Chang-Yun;Jung, Chung-Il
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.6
    • /
    • pp.717-721
    • /
    • 2010
  • In general, wireless MAC uses the ACK for reliability. Meanwhile, in wireless sensor network, data is delivered periodically and redundantly. In these situations, every ACK transmission causes the reliability flexible applications to waste some energy. IEEE 802.15.4 developed for energy efficiency has the option of using ACK or not, but there are no researches exploiting this peculiarity. In this paper, we proposed the selective unacknowledged transmission satisfying some requirements (e.g., end-to-end delivery) by removing the ACK when frames are delivered well and using the ACK when frames are delivered poorly. Also, we performed several evaluations exploiting the NS2 simulator.