• Title/Summary/Keyword: $NO_2$ gas sensor

Search Result 179, Processing Time 0.033 seconds

Fabrication and Characteristics of ZnO:In Thin Film $NH_3$ Gas Sensor (ZnO:In 박막 $NH_3$ 가스센서의 제작 및 특성)

  • Kim, Jin-Hae;Jun, Choon-Bae;Park, Ki-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.274-282
    • /
    • 1999
  • The In doped ZnO(ZnO:In)thin films sensitive to $NH_3$ gas were prepared by the double layer depositions of In film by vacuum evaporation and ZnO film by rf magnetron sputtering method onto a $SiO_2$/Si wafer substrate, and subsequent heat treatment process. The structural and electrical characteristics of the ZnO:In thin films were studied as a function of heat treatment temperature by x-ray diffraction, scanning electron microscope and 4 point probing method. And the dependence of the sensitivity, the selectivity and the time response of the thin films on heat treatment temperature was investigated. The thin film heat-treated at $400^{\circ}C$ showed the highest sensitivity of 140% at an operating temperature of $300^{\circ}C$. The sensitivity towards CO, $NO_x$, gases observed in the same temperature.

  • PDF

The fabrication and gas sensing characteristics of $LaFeO_3$ thin film sensor ($LaFeO_3$ 박막센서의 제작 및 가스 검지 특성)

  • Jang, Jae-Young;Shin, Jeong-Ho;Kim, Tae-Jung;Kim, Jun-Gon;Park, Ki-Chul;Kim, Jeong-Gyoo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1756-1758
    • /
    • 1999
  • As new gas sensing material with high cata activity for NO decomposition and for CO oxid $LaFeO_3$ thin films with different thicknesses fabricated by the R.F. magnetron sputtering m on an $Al_2O_3$ substrates with Ag electrodes. The sensing characteristics of the $LaFeO_3$ thin films studied as a function of annealing temperature film thickness. The thin film annealed at showed the highest sensitivity of 110% for CO 60% for NO.

  • PDF

NO2 Sensing Characteristics of WO3 Thick Film Sensors Using Nanosized WO3 Powders Prepared by Sol-Precipitation Process (Sol-Precipitation법으로 제조된 WO3 나노분말을 이용한 후막 센서의 NO2 감지 특성)

  • Ryu, Hyun-Wook;Park, Kyung-Hee;Kim, In-Chun;Hong, Kwang-Joon;Park, Jin-Seong
    • Korean Journal of Materials Research
    • /
    • v.12 no.12
    • /
    • pp.930-934
    • /
    • 2002
  • Nanosized $WO_3$ powders were synthesized by the sol-precipitation process using $WCl_{6}$ as the starting material, ethanol as a solvent and $NH_4$OH solution as a precipitant, followed by a washing-drying treatment and calcination. The effects on the powder crystallinity and microstructure of calcination temperature were investigated with XRD and FE-SEM. The $WO_3$ powders calcined at $500^{\circ}C$ and $700^{\circ}C$ showed good crystallinity and their mean particle size was 30nm and 70nm, respectively. These powders were used for the preparation of pastes which were printed as thick films on alumina substrates with comb-type Pt electrodes. The particle size strongly influenced the $NO_2$ gas sensing property of the thick films. A significant reduction in the $NO_2$ sensitivity was observed for the film prepared from larger particle size, having thus a larger grain size. For the film having a smaller grain size, on the other hand, the higher $NO_2$ sensitivity was observed and the sensitivity increased with $NO_2$ concentration.

Study on Preparation of Metal Phthalocyanine Derivative Langmuir-Blodgett Film (금속 프탈로시아닌 유도체의 Langumuir-Blodgett 박막 제작에 관한 연구)

  • Shin, Hyun-Man;Ha, Yun-Kyung;Kim, Young-Kwan;Sohn, Byoung-Chung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.89-95
    • /
    • 1997
  • It is well known that the metallo-phthalocyanine(MPcs) are sensitive to toxic gaseous molecules such as $NO_2$ and also chemically and thermally stable. Therefore, lots of MPcs have been studied for the potential chemical sensor for $NO_2$ gas using quartz crystal microbalance or electrical conductivity. In this study, 2,3,9,10,16,17,23,24-[octa-(dodecyloxy)] copper phthalocyanine and 2,3,9,10,16,17,23,24-[octa-(octyloxy)] copper phthalocyanine were synthesized and their possibility of LB film preparation were tested. It was confirmed by using FT-IR, DSC, NMR, UV-Vis absorption spectroscopy and Elemental Analysis that CuPc derivatives were successfully synthesized. From the ${\pi}$-A characteristics and limiting areas of two CuPc derivatives it was found that the preparation of LB films with these CuPc derivatives is possible.

Hydrogen sensing of Nano thin film and Nanowire structured cupric oxide deposited on SWNTs substrate: A comparison

  • Hoa, Nguyen Duc;Quy, Nguyen Van;O, Dong-Hun;Wei, Li;Jeong, Hyeok;Kim, Do-Jin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.52.1-52.1
    • /
    • 2009
  • Cupric oxide (CuO) is a p-type semiconductor with band gap of ~1.7 eV and reported to be suitable for catalysis, lithium-copper oxide electrochemical cells, and gas sensors applications. The nanoparticles, plates and nanowires of CuO were found sensing to NO2, H2S and CO. In this work, we report about the comparison about hydrogen sensing of nano thin film and nanowires structured CuO deposited on single-walled carbon nanotubes (SWNTs). The thin film and nanowires are synthesized by deposition of Cu on different substrate followed by oxidation process. Nano thin films of CuO are deposited on thermally oxidized silicon substrate, whereas nanowires are synthesized by using a porous thin film of SWNTs as substrate. The hydrogen sensing properties of synthesized materials are investigated. The results showed that nanowires cupric oxide deposited on SWNTs showed higher sensitivity to hydrogen than those of nano thin film CuO did.

  • PDF

Nerve-Agent Selective Chemiresistors Fabricated by Oxime Decorated Polypyrrole Layer on Cellulose Paper (셀룰로오스 종이 상에 Oxime 도입된 polypyrrole 층을 제조한 신경작용제 선택적 화학저항 센서)

  • Changhoon Jeon;Taihwan Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.528-534
    • /
    • 2024
  • In continuous research of detecting highly toxic chemical warfare agents to ensure preparedness for the future battlefield, flexible and wearable sensor platforms with high sensitivity are still demanding. Herein we demonstrate a facile fabrication of polypyrrole-based chemiresistors on cellulose paper for the detection of nerve gas simulants. In order to optimize electrical properties of sensor platform, conducting polymer made of polypyrrole were first synthesized on flexible cellulose paper and interdigitated electrodes were formed thereon. Following confirmation of polypyrrole and/or oxime moiety through FT-IR analyses, electrical characteristics were measured in the various ratio of monomers between simple pyrrole and oxime-modified one. Typically for the optimized chemiresistor(2:8 molar ratio of simple pyrrole and oxime-modified one), eleven species of chemical warfare agents were examined and enhanced conductivity(104~105 order) was observed for three simulants(diethyl cyanophosphonate, diisopropyl fluorophosphonate and diethyl chlorophosphonate), which was mainly attributed to intermolecular hydrogen bonding, while no significant responses was recorded against sixteen common volatile organic chemicals.

Quality Evaluation of Dried Laver (Porphyra yezoensis Ueda) Using Electronic Nose Based on Metal Oxide Sensor or GC with SAW Sensor During Storage (Metal oxide 센서를 바탕으로한 전자코와 SAW 센서를 바탕으로한 GC를 이용한 저장 중 김의 품질 평가)

  • Cho, Yen-Soo;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.947-953
    • /
    • 2002
  • Two types of electronic nose were used for investigating the quality of dried lavers stored at 5, 15, and $30^{\circ}C$ RH of 32, 43, and 75%. The electronic nose is composed of metal oxide sensors, and GC is based on SAW sensor. Quality change in dried lavers was described in terms of the sensitivities $(R_{gas}/R_{air})$ of the sensors. Principal component analysis (PCA) was carried out using data obtained from six metal oxide sensors. The first principal component scores were correlated with quality changes of dried lavers. As storage time increased, the stored laver cluster separated from that of fresh lavers. A chromatogram was obtained from GC based on SAW sensor. Olfactory image, A $VaporPrint^{TM}$ image for pattern recognition, showed a significant difference between the stored and the fresh samples. Dried lavers during storage at $30^{\circ}C$ and 75% had bacterial counts of $5.7{\times}10^6\;CFU/g$ after 8 day. Increase of microbial count correlated with the response of electronic nose $(r^2=0.87)$. Whereas, color values showed no correlation.

Comparison of Arterial Oxygen Saturation Measured by Pulse Oximetry at Different Sensor Sites in Neurocritical Patients (신경계 중환자의 측정부위별 맥박 산소포화도의 비교)

  • Jeon, Min-Jeong;Hwang, Sun-Kyung
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Purpose : This study aimed to compare peripheral pulse oxygen saturation (SpO2) values, measured at different monitoring sites, and arterial oxygen saturation (SaO2) of neurocritical patients. Methods : The study included 110 patients admitted to the neurosurgical intensive care unit of a university hospital. The patients' SpO2 values were measured in their index fingers, both second toes, both earlobes, and foreheads, using the patient monitoring system. These values were compared with the standard value of SaO2 measured using a blood gas analyzer. Data were analyzed using descriptive values, Pearson's correlation coefficients, Lin's concordance correlation coefficients (CCC), and Bland-Altman plots. Result : Regardless of the measuring site, SpO2 was correlated with the paired measurements of SaO2 (r=.40~.60, p<.001, CCC range=.40~.58). No significant bias in paired measurements of SpO2 and SaO2 was observed at all sites (-0.06~0.19%, p>.05). SpO2 values at the left finger and right earlobe had the narrowest range, with a 95% limits of agreement (LOA) (left finger -3.04~2.93% and right earlobe -3.18~2.79%). SpO2 at the index finger, on the side without an arterial catheter, had a narrower range of 95% LOA than that of the opposing finger (-3.00~2.97% vs. -3.73~3.26%). Conclusion : SpO2 at the finger without an arterial catheter had the highest level of precision. This study suggests using the index finger, on the side without an arterial catheter, for pulse oximetry in neurocritical patients.

The Study on the Production Method of Stepwise Dilution Gas for Odor Analysis with Orifice Tubes (오리피스 튜브에 의한 단계별 냄새 분석용 희석가스의 제조방법에 관한 연구)

  • Kim, Han-Soo;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • This study is to develop the production method of stepwise dilution gas for the evaluation of complex odor concentration by orifice tube. The basic orifice tube for 10 and 30 times of dilution sample was made at first, and with the combination of the basic orifice tubes we can continuously manufacture the stepwise dilution sample gas for air dilution sensory test ; 10, 30, 100, 300, 1,000, 3,000 times etc. The hole size of orifice tube was 0.84 mm for 10 times of dilution sample, and was 0.34 mm for 30 times. Dilution sample gas made with the basic orifice tube have an excellent reproducibility, 2%RSD. In addition, over 90% of correlation was shown between the sample made by the orifice tube and the sample by the syringe dilution method. Because there was no concentration drift of dilution gas with changes of connected pump flow, the basic orifice tube could be mounted directly with a vacuum suction box, and could be used simply as a tool for the evaluation of odor, especially on site.

Evaluations of Mn-Ni-Co type thermistor thin film for thermal infrared sensing element (열형 적외선 센싱소자용 Mn-Ni-Co계 써미스터 박막 특성 평가)

  • 전민석;최덕균
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.6
    • /
    • pp.297-303
    • /
    • 2003
  • Mn-Ni-Co type thin films were prepared at various conditions by a rf magnetron sputtering system. At the condition. or substrate temperature of $300^{\circ}C$ and $Ar/O_2$= 10/0, a cubic spinel phase was obtained. When oxygen was included in process gas, a cubic spinel phase was not formed even after the thermal annealing at $900^{\circ}C$. The thermistor thin film had no other elements except Mn, Ni and Co. The infrared reflection spectra of the thermistor thin films showed that the films had somewhat high reflectance for incoming infrared ray with some angle. The etch rate of the thermistor thin films was about 63nm/min at a condition of DI water : $HNO_3$: HCl = 60 : 30 : 10 vol%. The B constant and temperature coefficient of resistance of the thermistor thin films were 3500 K and -3.95 %/K, respectively. The voltage responsivity of the thermistor thin film infrared sensor was 108.5 V/W and its noise equivalent power and specific detectivity were $5.1\times 10^{-7}$ W/$Hz^{-1/2}$ and $0.2\times 10^6$cm $Hz^{1/2}$/W, respectively.