• 제목/요약/키워드: $L_k$-operator

검색결과 328건 처리시간 0.028초

EXISTENCE, MULTIPLICITY AND REGULARITY OF SOLUTIONS FOR THE FRACTIONAL p-LAPLACIAN EQUATION

  • Kim, Yun-Ho
    • 대한수학회지
    • /
    • 제57권6호
    • /
    • pp.1451-1470
    • /
    • 2020
  • We are concerned with the following elliptic equations: $$\{(-{\Delta})^s_pu={\lambda}f(x,u)\;{\text{in {\Omega}}},\\u=0\;{\text{on {\mathbb{R}}^N{\backslash}{\Omega}},$$ where λ are real parameters, (-∆)sp is the fractional p-Laplacian operator, 0 < s < 1 < p < + ∞, sp < N, and f : Ω × ℝ → ℝ satisfies a Carathéodory condition. By applying abstract critical point results, we establish an estimate of the positive interval of the parameters λ for which our problem admits at least one or two nontrivial weak solutions when the nonlinearity f has the subcritical growth condition. In addition, under adequate conditions, we establish an apriori estimate in L(Ω) of any possible weak solution by applying the bootstrap argument.

Ground Speed Control of a Direct Injection Sprayer

  • Koo, T.M.;Sumner, H.R.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.500-510
    • /
    • 1996
  • A Direct injection -mixing total -flow -control sprayer was developed and evaluated . The system provided precise application rates and minimized operator exposure to chemicals as well as providing a possibility for recycling container so f unused chemicals that can causes environmental contamination. Chemicals were metered and injected proportionally to the diluent flow rate to provide constant concentrations. The main diluent flow was varied in response to changes in travel speed. Experimental variables of the sprayer were the control interval, the sensitivity of flow regulating valve, the tolerance of control object and the sensitivity of the injection pump system. The optimal performance of the flow control system was with an average response time of 8.5 sec at an absolute steady state of error of 0.067 L/min (0.8% of flow rate). The average response time of the injection rate was -0.53 sec and the coefficient of variation (CV) of concentration was 3.2%.

  • PDF

Purification and Characterization of Repressor of Temperate S. aureus Phage Φ11

  • Das, Malabika;Ganguly, Tridib;Chattoraj, Partho;Chanda, Palas Kumar;Bandhu, Amitava;Lee, Chia Yen;Sau, Subrata
    • BMB Reports
    • /
    • 제40권5호
    • /
    • pp.740-748
    • /
    • 2007
  • To gain insight into the structure and function of repressor proteins of bacteriophages of gram-positive bacteria, repressor of temperate Staphylococcus aureus phage ${\phi}11$ was undertaken as a model system here and purified as an N-terminal histidine-tagged variant (His-CI) by affinity chromatography. A ~19 kDa protein copurified with intact His-CI (~ 30 kDa) at low level was resulted most possibly due to partial cleavage at its Ala-Gly site. At ~10 nM and higher concentrations, His-CI forms significant amount of dimers in solution. There are two repressor binding sites in ${\phi}11$ cI-cro intergenic region and binding to two sites occurs possibly by a cooperative manner. Two sites dissected by HincII digestion were designated operators $O_L$ and $O_R$, respectively. Equilibrium binding studies indicate that His-CI binds to $O_R$ with a little more strongly than $O_L$ and binding species is probably dimeric in nature. Interestingly His-CI binding affinity reduces drastically at elevated temperatures ($32-42^{\circ}C$). Both $O_L$ and $O_R$ harbor a nearly identical inverted repeat and studies show that ${\phi}11$ repressor binds to each repeat efficiently. Additional analyses indicate that ${\phi}11$ repressor, like $\lambda$ repressor, harbors an N-terminal domain and a C-terminal domain which are separated by a hinge region. Secondary structure of ${\phi}11$ CI even nearly resembles to that of $\lambda$ phage repressor though they differ at sequence level. The putative N-terminal HTH (helix-turn-helix) motif of ${\phi}11$ repressor belongs to the HTH -XRE-family of proteins and shows significant identity to the HTH motifs of some proteins of evolutionary distant organisms but not to HTH motifs of most S. aureus phage repressors.

외과계 중환자실에서 사망률 감소를 위한 적정혈당지표에 관한 연구 (Optimal Glycemic Control to Reduce Mortality in Surgical Intensive Care Unit)

  • 윤소정;송영천;김재연;이병구;곽혜선
    • 한국임상약학회지
    • /
    • 제20권2호
    • /
    • pp.107-113
    • /
    • 2010
  • 서 론: 중환자실에서 집중적 인슐린 요법에 의한 평균혈당강하는 사망률을 감소시키는 것으로 나타났으나 이로 인한 저혈당 및 혈당변동은 새로운 문제로 대두되고 있다. 본 연구에서는 혈당과 관련한 여러 요인들이 사망에 미치는 영향을 규명하고 적정 혈당치를 확인하고자 하였다. 연구방법: 2008년 2월부터 7월 사이인 6개월 동안 서울아산병원 외과계 중환자실에서 4일 이상 재실한 18세 이상의 성인 환자를 대상으로 전자 의무기록 조사를 통해 후향적으로 연구가 진행되었다. 연구를 위해 환자의 인구학적 특성, 수술의 종류, 중환자실에서의 재실기간, 사망여부, 스테로이드 사용 유무, 기계적 인공호흡기의 사용유무, 신대체요법의 사용유무, 혈당치, 재실기간 중 스테로이드 사용유무와 인슐린 양, 입원 후 첫 24시간 동안의 포도당 주입속도, 입원 후 2일 이내와 그 이후에 발생한 균혈증 감염, APACH II와 SOFA 점수를 조사하였다. 혈당수치는 각각의 환자에서 중환자실 입실 후 가장 처음 측정된 혈당, 재실기간 중 가장 높은 혈당과 가장 낮은 혈당수치를 조사하였고 중환자실 전체 재실기간 동안 혈당수치의 평균과 변동계수를 계산하였다. 이상의 혈당관련지표를 포함한 인자들이 일차 종속변수인 사망에 어떠한 영향을 주는지를 환자를 생존군과 사망군으로 나누어 분석하였고 ROC (receiver operator characteristic) 곡선을 사용하여 혈당지표와 APACH 및 SOFA 점수의 cut-off치를 구하여 이로부터 단변량 및 다변량 분석을 시행하였다. 결 과: 연구에 포함된 환자는 170명 이었고 그 중 23명이 연구 기간 중 중환자실에서 사망하였다. 생존자에 비해 사망자의 최대혈당은 유의적으로 높았고 최소혈당치는 유의적으로 낮아 높은 변동계수를 보였다. ROC곡선으로부터 산출된 혈당치들의 cut-off 수치는 최소혈당치 70 mg/dL, 변동계수 25%, 최대혈당치 250 mg/dL, 평균혈당치 150 mg/dL이었다. 다변량분석에서 최소혈당이 70 mg/dL 보다 큰 경우가 낮은 경우에 비해 오즈비가 0.922(95% 신뢰구간 0.881-0.965)로 유의성 있게 낮았으며 변동계수가 25% 보다 높은 집단의 경우 그보다 낮은 집단에 비해 오즈비가 1.121(95% 신뢰구간 1.017-1.236)로 유의성 있게 높았다. Kaplan-Meier 생존분석 결과 최소혈당치 70 mg/dL와 변동계수 25%에 따라 생존기간에 유의성 있는 차이가 나타났다.(각각 P < 0.001, P < 0.05) 결 론: 고혈당 발생의 감소뿐 아니라 최소혈당치를 70 mg/dL 이상으로 유지하면서 변동을 최소화하는 것이 외과계 중환자실에서의 사망률감소를 위한 중요한 요인임을 알 수 있었다.

The Performance Evaluation of NSSS Control Systems for UCN 4

  • Sohn, Suk-Whun;Song, In-Ho;Sohn, Jong-Joo;Park, Jong-Ho;Seo, Jong-Tae
    • Nuclear Engineering and Technology
    • /
    • 제33권3호
    • /
    • pp.339-348
    • /
    • 2001
  • NSSS Control Systems automatically mitigate transient conditions and leads to a stable plant condition without operator actions when a transient occurs during normal power operation. In this paper, the function and performance of NSSS control systems were examined and evaluated by comparing the predicted results with the measured data for the selected events. Loss of a Main Feedwater Pump and Load Rejection to House Load Operation events were selected for the evaluation among the transient tests peformed during the Power Ascension Test (PAT) of UCN unit 4. The overall schematic control actions of NSSS control systems can be evaluated easily through the observation of these two typical events. The selected events were analyzed by the KISPAC computer code[l] which had been used in developing the control logic and determining the control setpoints during the plant design. Additionally, the performance of FWCS during low power operation was evaluated. The result of evaluation showed that the NSSS control systems were designed properly and the performance of the NSSS control systems was excellent and also the computer code had a good prediction capability.

  • PDF

A Noisy-Robust Approach for Facial Expression Recognition

  • Tong, Ying;Shen, Yuehong;Gao, Bin;Sun, Fenggang;Chen, Rui;Xu, Yefeng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권4호
    • /
    • pp.2124-2148
    • /
    • 2017
  • Accurate facial expression recognition (FER) requires reliable signal filtering and the effective feature extraction. Considering these requirements, this paper presents a novel approach for FER which is robust to noise. The main contributions of this work are: First, to preserve texture details in facial expression images and remove image noise, we improved the anisotropic diffusion filter by adjusting the diffusion coefficient according to two factors, namely, the gray value difference between the object and the background and the gradient magnitude of object. The improved filter can effectively distinguish facial muscle deformation and facial noise in face images. Second, to further improve robustness, we propose a new feature descriptor based on a combination of the Histogram of Oriented Gradients with the Canny operator (Canny-HOG) which can represent the precise deformation of eyes, eyebrows and lips for FER. Third, Canny-HOG's block and cell sizes are adjusted to reduce feature dimensionality and make the classifier less prone to overfitting. Our method was tested on images from the JAFFE and CK databases. Experimental results in L-O-Sam-O and L-O-Sub-O modes demonstrated the effectiveness of the proposed method. Meanwhile, the recognition rate of this method is not significantly affected in the presence of Gaussian noise and salt-and-pepper noise conditions.

한국에서 이동전화 번호이동성 시스템을 위한 데이터베이스 관리 시스템 (The Database management system for the MNP in Korea)

  • 정영식;김완우
    • 대한전자공학회논문지TC
    • /
    • 제43권2호
    • /
    • pp.49-55
    • /
    • 2006
  • 본 논문은 이동전화 번호이동성을 위한 세상에서 가장 진화된 데이터베이스 관리 시스템에 관한 것이다. 데이터베이스 관리 시스템은 번호이동 절차를 30분안에 완료할 수 있고, 그것은 현재 세상에서 가장 빠른 것이다. 이동전화번호이동성 데이터베이스 관리시스템은 두개의 기능 블락으로 구성되어 있는데, 하나는 호처리시스템이고 하나는 이동전화번호이동성의 가입자들이다. 하드웨어와 처리구조가 본 논문에 제시되어 있다. 호처리를 위한 DB 는 각각의 이동전화 사업자망에 위치하고 있으며 L-NPDB라고 불리운다. 이동전화 번호이동성의 가입자를 다루는 DB는 L-NPDB와 한국통신사업자연합회에 있는 maste-NPDBT로 구성되어 있다 이동전화 번호이동성을 위한 하드웨어는 NPCDB와 L-NPDB와 M-NPDB간의 상호접속으로 구성되어 있다. master 데이터베이스는 L-NPDB와 전용선으로 연결되어 있으며, MNP 서비스를 실시간으로 처리할 수 있다. 본 논문에서 제안하는 이동전화 번호이동성 구조는 한국에서 실제로 구현되었고 이동전화 번호이동성을 위한 세계에서 가장 효율적이고 진화된 데이터베이스 관리 시스템이 되었다.

Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰 (A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume)

  • 김진구;함준철;오신현;강천구;김재삼
    • 핵의학기술
    • /
    • 제24권1호
    • /
    • pp.20-26
    • /
    • 2020
  • 핵의학이란 방사성동위원소 추적자를 인체에 투여하여 관심장기에 대한 형태학적인 정보와 생물학적이고 기능적인 정보를 얻고 평가한다. Dose calibrator는 의료기관에서 단일 핵종의 방사능을 측정하기 위해 사용하는 장비이며, 방사성동위원소의 정확한 용량의 투여는 진단과 치료에 중요한 요인이다. 최근 정량분석을 위한 여러 시스템이 개발되고 있고 ERPF (Effective Renal Plasma Flow), GFR (Glomerular Filtration Rate) 등 정량분석이 필요한 검사에 있어서 정확한 투여 용량 및 재현성 있는 측정이 중요해지고 있다. 따라서 본 논문을 통해 Dose calibrator의 측정 깊이와 용량에 따른 선량 값의 성향을 알아보고 적절한 측정 깊이 및 용량에 대해 알아 보고자 한다. 실험에 사용한 Dose calibrator는 CRC-15R과 CRC-15βeta (Capintec, New Jersey, USA)를 사용하였다. 선원으로는 표준선원(Standard source) 137Cs, 133Ba, 57Co를 사용하였고, 방사성 의약품은 99mTc-pertechnetate를 사용하였다. 표준선원은 측정 깊이만 변화하여 0 cm부터 15 cm까지 1 cm 깊이마다 15회씩 측정했고, 99mTc-pertechnetate의 경우에는 1 mL 주사기로 표준선원과 동일한 깊이로 실험을 진행했고, 용량의 변화를 고려하여 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL, 0.9 mL로 각 깊이마다 15회씩 측정했다. 표준선원인 137Cs, 133Ba, 57Co의 깊이의 변화에서는 모두 깊이에 따른 선량 값의 변화가 통계적으로 유의한 차이가 있었다(p<0.05). 99mTc-pertechnetate도 깊이에 따른 용량의 변화에서 선량 값이 모두 통계적으로 유의한 차이가 있었다(p<0.05). CRC-15R의 표준선원 비교 그래프에서 137Cs, 133Ba, 57Co는 Plateau를 그리기 시작한 2 cm에서 9 cm까지는 각 선원마다 비교시 통계적으로 유의한 차이가 없었다(p>0.05). CRC-15βeta의 표준선원 비교 그래프에서는 Plateau를 그리기 시작한 영역은 3 cm에서 9 cm로 통계적으로 유의한 차이가 없었다(p>0.05). 99mTc-pertechnetate의 그래프는 0.1 mL에서 1 cm에서 7 cm, 0.3 mL와 0.5 mL에서는 0 cm에서 7 cm, 0.7 mL에서는 0 cm에서 6 cm, 0.9 mL에서는 0 cm에서 5 cm에서 통계적으로 유의한 차이가 나타나지 않았다(p>0.05). 본 연구를 통해 방사성동위원소를 환자에게 주입하거나 정도관리를 진행 시 편차가 적고 재현성을 위해 신뢰할 수 있는 구간을 확인 할 수 있었다. 높이에 따른 변화가 가장 적은 Plateau의 구간이 0.3 mL 혹은 0.5 mL의 용량으로 0 cm 에서 7 cm의 깊이에서 측정한다면, 편차를 최소한으로 줄일 수 있을 것으로 사료된다. 표준선원의 경우에는 본 연구의 결과에 따라 장비마다 Plateau의 변화가 가장 적은 구간의 깊이에서 재현성 있게 측정하는 것이 중요하다고 생각된다. 적절한 구간을 찾아서 재현성 있는 검사를 시행하면 검사의 품질향상 및 피폭선량저감 그리고 진단능을 높이는데 이바지 할 것이라고 생각된다.

햅틱 복강경 수술 시뮬레이터의 마찰력 및 중력 보상 (Approximate Friction and Gravity Compensation in Haptic Laparoscopic Surgery Simulator)

  • 김상현;이창규;김지석;류제하
    • 대한기계학회논문집A
    • /
    • 제35권8호
    • /
    • pp.883-888
    • /
    • 2011
  • 복강경을 이용한 수술법은 입원 기간 단축 및 상처의 감소라는 장점이 있지만 수술 도구 끝단의 움직임의 제한으로 인한 수술 난이도의 증가라는 단점이 있다. 이를 숙련시키기 위해 동물을 이용하여 대체수술을 하거나, Surgery training tool set을 이용하여 조작 기술 습득을 위한 훈련을 하고 있다. 하지만 이 방법들은 사람에게서 느껴지는 촉감을 그대로 재현하지 못한다. 따라서 본 논문은 4-자유도계의 복강경 수술 의료 훈련 시뮬레이터를 통해 원활한 햅틱 피드백을 제공하였다. 햅틱 장비의 기본 요구조건인 무중력, 무마찰 상태를 만족시키기 위해 장비의 중력 및 마찰력을 측정하였다. 이를 위해 의료 시뮬레이터의 모델링을 하여 시술기에 작용하는 중력과 마찰력을 측정하고 이를 선형화 시킨후 이를 토대로 보상기를 모델링하고 이를 검증하였다.

PROLONGATION OF THE BOR-60 REACTOR OPERATION

  • IZHUTOV, ALEXEY L.;KRASHENINNIKOV, YURI M.;ZHEMKOV, IGOR Y.;VARIVTSEV, ARTEM V.;NABOISHCHIKOV, YURI V.;NEUSTROEV, VICTOR S.;SHAMARDIN, VALENTIN K.
    • Nuclear Engineering and Technology
    • /
    • 제47권3호
    • /
    • pp.253-259
    • /
    • 2015
  • The fast neutron reactor BOR-60 is one of the key experimental facilities worldwide to perform large-scale tests of fuel, absorbing, and structural materials for advanced reactors. The BOR-60 reactor was put into operation in December 1969, and by the end of 2014 it had been operating on power for ~265,000 hours. BOR-60 still demonstrates potential capabilities to extend the lifetime of sodium-cooled fast reactors. The BOR-60 lifetime should have expired at the end of 2014. Over the past few years, a great scope of work has been performed to justify the possibility of extending its lifetime. The work included inspection of the equipment conditions, calculations and experimental research on operating parameters and the conditions of nonremovable components, investigation of the structural material samples after their long-term operation under irradiation, etc. Based on the results of the work performed, the residual lifetime was evaluated and the reactor operator made a decision to extend the lifetime period of the BOR-60 reactor. After considering both a set of documents about the reactor conditions and the positive decision of independent experts, the Regulatory Authority of the Russian Federation extended the BOR-60 operating license up to 2020.