• Title/Summary/Keyword: $L_k$-operator

Search Result 328, Processing Time 0.022 seconds

EXISTENCE, MULTIPLICITY AND REGULARITY OF SOLUTIONS FOR THE FRACTIONAL p-LAPLACIAN EQUATION

  • Kim, Yun-Ho
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.6
    • /
    • pp.1451-1470
    • /
    • 2020
  • We are concerned with the following elliptic equations: $$\{(-{\Delta})^s_pu={\lambda}f(x,u)\;{\text{in {\Omega}}},\\u=0\;{\text{on {\mathbb{R}}^N{\backslash}{\Omega}},$$ where λ are real parameters, (-∆)sp is the fractional p-Laplacian operator, 0 < s < 1 < p < + ∞, sp < N, and f : Ω × ℝ → ℝ satisfies a Carathéodory condition. By applying abstract critical point results, we establish an estimate of the positive interval of the parameters λ for which our problem admits at least one or two nontrivial weak solutions when the nonlinearity f has the subcritical growth condition. In addition, under adequate conditions, we establish an apriori estimate in L(Ω) of any possible weak solution by applying the bootstrap argument.

Ground Speed Control of a Direct Injection Sprayer

  • Koo, T.M.;Sumner, H.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.500-510
    • /
    • 1996
  • A Direct injection -mixing total -flow -control sprayer was developed and evaluated . The system provided precise application rates and minimized operator exposure to chemicals as well as providing a possibility for recycling container so f unused chemicals that can causes environmental contamination. Chemicals were metered and injected proportionally to the diluent flow rate to provide constant concentrations. The main diluent flow was varied in response to changes in travel speed. Experimental variables of the sprayer were the control interval, the sensitivity of flow regulating valve, the tolerance of control object and the sensitivity of the injection pump system. The optimal performance of the flow control system was with an average response time of 8.5 sec at an absolute steady state of error of 0.067 L/min (0.8% of flow rate). The average response time of the injection rate was -0.53 sec and the coefficient of variation (CV) of concentration was 3.2%.

  • PDF

Purification and Characterization of Repressor of Temperate S. aureus Phage Φ11

  • Das, Malabika;Ganguly, Tridib;Chattoraj, Partho;Chanda, Palas Kumar;Bandhu, Amitava;Lee, Chia Yen;Sau, Subrata
    • BMB Reports
    • /
    • v.40 no.5
    • /
    • pp.740-748
    • /
    • 2007
  • To gain insight into the structure and function of repressor proteins of bacteriophages of gram-positive bacteria, repressor of temperate Staphylococcus aureus phage ${\phi}11$ was undertaken as a model system here and purified as an N-terminal histidine-tagged variant (His-CI) by affinity chromatography. A ~19 kDa protein copurified with intact His-CI (~ 30 kDa) at low level was resulted most possibly due to partial cleavage at its Ala-Gly site. At ~10 nM and higher concentrations, His-CI forms significant amount of dimers in solution. There are two repressor binding sites in ${\phi}11$ cI-cro intergenic region and binding to two sites occurs possibly by a cooperative manner. Two sites dissected by HincII digestion were designated operators $O_L$ and $O_R$, respectively. Equilibrium binding studies indicate that His-CI binds to $O_R$ with a little more strongly than $O_L$ and binding species is probably dimeric in nature. Interestingly His-CI binding affinity reduces drastically at elevated temperatures ($32-42^{\circ}C$). Both $O_L$ and $O_R$ harbor a nearly identical inverted repeat and studies show that ${\phi}11$ repressor binds to each repeat efficiently. Additional analyses indicate that ${\phi}11$ repressor, like $\lambda$ repressor, harbors an N-terminal domain and a C-terminal domain which are separated by a hinge region. Secondary structure of ${\phi}11$ CI even nearly resembles to that of $\lambda$ phage repressor though they differ at sequence level. The putative N-terminal HTH (helix-turn-helix) motif of ${\phi}11$ repressor belongs to the HTH -XRE-family of proteins and shows significant identity to the HTH motifs of some proteins of evolutionary distant organisms but not to HTH motifs of most S. aureus phage repressors.

Optimal Glycemic Control to Reduce Mortality in Surgical Intensive Care Unit (외과계 중환자실에서 사망률 감소를 위한 적정혈당지표에 관한 연구)

  • Yoon, So-Jung;Song, Young-Chun;Kim, Jae-Yeon;Lee, Byung-Koo;Gwak, Hye-Sun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.2
    • /
    • pp.107-113
    • /
    • 2010
  • 서 론: 중환자실에서 집중적 인슐린 요법에 의한 평균혈당강하는 사망률을 감소시키는 것으로 나타났으나 이로 인한 저혈당 및 혈당변동은 새로운 문제로 대두되고 있다. 본 연구에서는 혈당과 관련한 여러 요인들이 사망에 미치는 영향을 규명하고 적정 혈당치를 확인하고자 하였다. 연구방법: 2008년 2월부터 7월 사이인 6개월 동안 서울아산병원 외과계 중환자실에서 4일 이상 재실한 18세 이상의 성인 환자를 대상으로 전자 의무기록 조사를 통해 후향적으로 연구가 진행되었다. 연구를 위해 환자의 인구학적 특성, 수술의 종류, 중환자실에서의 재실기간, 사망여부, 스테로이드 사용 유무, 기계적 인공호흡기의 사용유무, 신대체요법의 사용유무, 혈당치, 재실기간 중 스테로이드 사용유무와 인슐린 양, 입원 후 첫 24시간 동안의 포도당 주입속도, 입원 후 2일 이내와 그 이후에 발생한 균혈증 감염, APACH II와 SOFA 점수를 조사하였다. 혈당수치는 각각의 환자에서 중환자실 입실 후 가장 처음 측정된 혈당, 재실기간 중 가장 높은 혈당과 가장 낮은 혈당수치를 조사하였고 중환자실 전체 재실기간 동안 혈당수치의 평균과 변동계수를 계산하였다. 이상의 혈당관련지표를 포함한 인자들이 일차 종속변수인 사망에 어떠한 영향을 주는지를 환자를 생존군과 사망군으로 나누어 분석하였고 ROC (receiver operator characteristic) 곡선을 사용하여 혈당지표와 APACH 및 SOFA 점수의 cut-off치를 구하여 이로부터 단변량 및 다변량 분석을 시행하였다. 결 과: 연구에 포함된 환자는 170명 이었고 그 중 23명이 연구 기간 중 중환자실에서 사망하였다. 생존자에 비해 사망자의 최대혈당은 유의적으로 높았고 최소혈당치는 유의적으로 낮아 높은 변동계수를 보였다. ROC곡선으로부터 산출된 혈당치들의 cut-off 수치는 최소혈당치 70 mg/dL, 변동계수 25%, 최대혈당치 250 mg/dL, 평균혈당치 150 mg/dL이었다. 다변량분석에서 최소혈당이 70 mg/dL 보다 큰 경우가 낮은 경우에 비해 오즈비가 0.922(95% 신뢰구간 0.881-0.965)로 유의성 있게 낮았으며 변동계수가 25% 보다 높은 집단의 경우 그보다 낮은 집단에 비해 오즈비가 1.121(95% 신뢰구간 1.017-1.236)로 유의성 있게 높았다. Kaplan-Meier 생존분석 결과 최소혈당치 70 mg/dL와 변동계수 25%에 따라 생존기간에 유의성 있는 차이가 나타났다.(각각 P < 0.001, P < 0.05) 결 론: 고혈당 발생의 감소뿐 아니라 최소혈당치를 70 mg/dL 이상으로 유지하면서 변동을 최소화하는 것이 외과계 중환자실에서의 사망률감소를 위한 중요한 요인임을 알 수 있었다.

The Performance Evaluation of NSSS Control Systems for UCN 4

  • Sohn, Suk-Whun;Song, In-Ho;Sohn, Jong-Joo;Park, Jong-Ho;Seo, Jong-Tae
    • Nuclear Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.339-348
    • /
    • 2001
  • NSSS Control Systems automatically mitigate transient conditions and leads to a stable plant condition without operator actions when a transient occurs during normal power operation. In this paper, the function and performance of NSSS control systems were examined and evaluated by comparing the predicted results with the measured data for the selected events. Loss of a Main Feedwater Pump and Load Rejection to House Load Operation events were selected for the evaluation among the transient tests peformed during the Power Ascension Test (PAT) of UCN unit 4. The overall schematic control actions of NSSS control systems can be evaluated easily through the observation of these two typical events. The selected events were analyzed by the KISPAC computer code[l] which had been used in developing the control logic and determining the control setpoints during the plant design. Additionally, the performance of FWCS during low power operation was evaluated. The result of evaluation showed that the NSSS control systems were designed properly and the performance of the NSSS control systems was excellent and also the computer code had a good prediction capability.

  • PDF

A Noisy-Robust Approach for Facial Expression Recognition

  • Tong, Ying;Shen, Yuehong;Gao, Bin;Sun, Fenggang;Chen, Rui;Xu, Yefeng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.4
    • /
    • pp.2124-2148
    • /
    • 2017
  • Accurate facial expression recognition (FER) requires reliable signal filtering and the effective feature extraction. Considering these requirements, this paper presents a novel approach for FER which is robust to noise. The main contributions of this work are: First, to preserve texture details in facial expression images and remove image noise, we improved the anisotropic diffusion filter by adjusting the diffusion coefficient according to two factors, namely, the gray value difference between the object and the background and the gradient magnitude of object. The improved filter can effectively distinguish facial muscle deformation and facial noise in face images. Second, to further improve robustness, we propose a new feature descriptor based on a combination of the Histogram of Oriented Gradients with the Canny operator (Canny-HOG) which can represent the precise deformation of eyes, eyebrows and lips for FER. Third, Canny-HOG's block and cell sizes are adjusted to reduce feature dimensionality and make the classifier less prone to overfitting. Our method was tested on images from the JAFFE and CK databases. Experimental results in L-O-Sam-O and L-O-Sub-O modes demonstrated the effectiveness of the proposed method. Meanwhile, the recognition rate of this method is not significantly affected in the presence of Gaussian noise and salt-and-pepper noise conditions.

The Database management system for the MNP in Korea (한국에서 이동전화 번호이동성 시스템을 위한 데이터베이스 관리 시스템)

  • Jeong, Young-Sic;Kim, WhAn-Woo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.2 s.344
    • /
    • pp.49-55
    • /
    • 2006
  • This paper describe the most advanced database management system for the mobile number portability(MNP) in the world The database management system can process the procedure of porting_out and porting_in in 30 minutes and it is the shortest time in the world. The MNP DB management system consists of two functional blocks, one is for the call processing system and the other is for the management of subscriber of MNP. The hardware and processing algorithm are presented in this paper. The DB for call processing is located at each mobile operator and be called local number portability database (L-NPDB). The DB for the management of subscriber of MNP consist of L-NPDB and master database which is located at the Korea telecommunications operators association(KTOA). The hardware database system for MNP consists of the interconnection system of master-NPCDB (NP customer database, M-NPCDB), local-NPCDB, M-NPDB and L-NPDB. The master database is interconnected to the local database through dedicated line and can process any MNP service in real time. The presented MNP structure in this paper has been implemented in Korea and became the most effective and advanced DB management system for MNP in the world.

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.

Approximate Friction and Gravity Compensation in Haptic Laparoscopic Surgery Simulator (햅틱 복강경 수술 시뮬레이터의 마찰력 및 중력 보상)

  • Kim, Sang-Hyun;Lee, Chang-Gyu;Kim, Ji-Suk;Ryu, Je-Ha
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.8
    • /
    • pp.883-888
    • /
    • 2011
  • Laparoscopic surgery is being used in various surgical fields because it minimizes scarring. Laparoscopic operations require practical hand skills, so surgeons train on animals and via surgery training tool sets. However, these tool sets do not give the surgeon the sensation of touching real organs. A recently developed laparoscope simulator has a high friction force along the translational axis and a high gravity force along the pitch axis, and therefore it does not permit the operator to control his or her hands delecately. In the paper, the friction force along the axes is auumed to depend on the veolcity, and the gravity force on the angle and distance. We develop a compensation model that combines the gravity and friction force models.

PROLONGATION OF THE BOR-60 REACTOR OPERATION

  • IZHUTOV, ALEXEY L.;KRASHENINNIKOV, YURI M.;ZHEMKOV, IGOR Y.;VARIVTSEV, ARTEM V.;NABOISHCHIKOV, YURI V.;NEUSTROEV, VICTOR S.;SHAMARDIN, VALENTIN K.
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.253-259
    • /
    • 2015
  • The fast neutron reactor BOR-60 is one of the key experimental facilities worldwide to perform large-scale tests of fuel, absorbing, and structural materials for advanced reactors. The BOR-60 reactor was put into operation in December 1969, and by the end of 2014 it had been operating on power for ~265,000 hours. BOR-60 still demonstrates potential capabilities to extend the lifetime of sodium-cooled fast reactors. The BOR-60 lifetime should have expired at the end of 2014. Over the past few years, a great scope of work has been performed to justify the possibility of extending its lifetime. The work included inspection of the equipment conditions, calculations and experimental research on operating parameters and the conditions of nonremovable components, investigation of the structural material samples after their long-term operation under irradiation, etc. Based on the results of the work performed, the residual lifetime was evaluated and the reactor operator made a decision to extend the lifetime period of the BOR-60 reactor. After considering both a set of documents about the reactor conditions and the positive decision of independent experts, the Regulatory Authority of the Russian Federation extended the BOR-60 operating license up to 2020.