• Title/Summary/Keyword: $K_0$ loading

Search Result 1,966, Processing Time 0.035 seconds

The Size of Crowd Pressure According to Loading Patterns (가력유형별 군중하중의 크기에 관한 실험적 연구)

  • Kim, Jin-Sik;Shin, Yun-Ho;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.128-129
    • /
    • 2016
  • This study is to categorize the loading of multiple persons on a vertical building elements into three types to test the size of crowd pressure under each loading patterns. The loading patterns is divided under the combination of loading method and loading persons. The loading method is categorized into the method of instantaneous loading of hand on a force plate and the method of continuous loading. The loading persons has been composed of 1~5 persons under the loading patterns. The loading patterns is also divided into lateral loading, longitudinal loading, and agglomeration loading. The subject group has been composed of 12 males in 20s. The load measurement device(size 1800×600×36mm, capacity 20kN, rigidity 28kN/cm) has been designed and manufactured directly. To eliminate the difference of individual, the size of crowd pressure has been converted into the strength to weight ratio (maximum load/weight) for computation. The strength to weight ratio in lateral loading was about 0.91 under instantaneous loading and about 0.47 under continuous loading. The strength to weight ratio in longitudinal loading was about 0.65 under instantaneous loading and about 0.36 under continuous loading. The strength to weight ratio in agglomeration loading was about 0.65 under instantaneous loading and about 0.36 under continuous loading.

  • PDF

Behavior of Laterally Cyclic Loaded Piles Driven into Sand (모래지반에서 반복수평하중을 받는 항타말뚝의 거동)

  • Paik, Kyu-Ho;Park, Won-Woo;Kim, Young-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.913-922
    • /
    • 2009
  • Fourteen model pile load tests using a calibration chamber and instrumented model pile were preformed to investigate the variation of the behaviors of driven piles in sands with soil and lateral cyclic loading conditions. Results of the model tests showed that the first loading cycle generated more than 70% of the pile head rotation developed for 50 lateral loading cycles. Lateral cyclic loading also made an increase of the ultimate lateral load capacity of piles for $K_0$=0.4 and an decrease for $K_0$ higher than 0.4. Higher portion of the increase or decrease in the ultimate lateral load capacity by lateral cyclic loading was generated for the first loading cycle due to densification of loosening of the soil around the pile by lateral cyclic loading. It was also observed that a two-way cyclic loading caused higher ultimate lateral load capacity of driven piles than a one-way cyclic loading. When the pile was in the ultimate state, the maximum bending moment developed in the pile increased with increasing $K_0$ value of soil and was insensitive to the magnitude and number of lateral cyclic loading.

  • PDF

Performance of Rotating Biological Contactor (RBC) under Different Hydraulic Loading Rates and Rotational Speeds on Ammonia Removal in a Recirculating System

  • Son Maeng Hyun;Jeon Im Gi;Jo Jae-Yoon;Moon HaeYoung
    • Fisheries and Aquatic Sciences
    • /
    • v.2 no.1
    • /
    • pp.52-57
    • /
    • 1999
  • Air-drived rotating biological contactor (RBC) system, which is effective method in filtering performance, was tested for the nitrification capacity in a recirculating system. At ammonia concentrations between 0.029 and 0.528 mg/l, the effect of ammonia loading rate on ammonia removal rate at three different hydraulic loading rates could be defined by the following first­order regression models: Hydraulic loading rate of $14.8 m^3/m^3/day:\;y=39.2\times+3.4 (r^2=0.9137)$, Hydraulic loading rate of $26.5 m^3/m^3/day: y=53.3\times+4.0 (r^2=0.8686)$, Hydraulic loading rate of $37.3 m^3/m^3/day: y=58.4\times+4.2 (r^2=0.7755)$, where, $\times$ is ammonia loading rate (mg/l), y is ammonia removal rate $(g/m^3/day)$, The equations showed the optimal ammonia removal rate at the hydraulic loading rate of $26.5m^3/m^3/day$. Below the ammonia concentration of 2.72 mg/l, first-order regression models between ammonia loading rate and ammonia removal rate at three different rates of speed are defined as follows: Rotational speed of $0.75 rpm: y=28.5\times+4.7 (r^2=0.9143)$, Rotational speed of $1.0 rpm: y=33.6\times+8.4 (r^2=0.9534)$, Rotational speed of $2.0 rpm: y=28.9\times+3.6 (r^2=0.9488)$, where, x is ammonia loading rate (mg/l), y is ammonia removal rate $(g/m^3day)$. The equations show the ammonia removal rate at the rotational speed of 1.0 rpm is significantly higher than that at the rotational speed of either 0.75 rpm or 2.0 rpm (P<0.05).

  • PDF

The Effect of Discharge Loading at Sewage Treatment Plants on Water Quality in Kyoungan Stream (경안천 수질에 대한 환경기초시설 방류부하량의 영향)

  • Kim, Ho-Sub;Lee, Su-Woong;Rhew, Doug-Hee;Kong, Dong-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.452-458
    • /
    • 2009
  • This study was carried out to assess the effect of discharge loading at sewage treatment plants (STP) on water quality in Kyoungan stream. The seasonal variations of water quality (BOD, COD, SS, TN, and chl.a) at site 1(Mesanribo) were similar with those at site 2(Sehabo). BOD, COD, SS, and chl.a concentration were also similar except for TN and TP concentration which were lower than those at site 1. The BOD, COD, TN, TP and chl.a concentration at site 2 in dry period were higher than that of wet period. The ratios of BOD, TP, COD, SS discharge loading at all STP in Kyoungan stream watershed to delivery loading at site 2 were 0.69, 0.54, 0.48, 0.31, and 0.26 on average, respectively. Both site 1 and site 2, the seasonal variations of discharge loading at STP did not showed any relationship with those of water quality. The mean ratios of inflow loading at site 1 to delivery loading at site 2 were relatively high that ranged from 0.43 to 0.61. In dry period, the ratios of discharge loading at STP in Sehabo watershed to delivery loading at site 2 were below 0.2 except for BOD (0.24), and decreased <0.1 in wet period. While, SS loading from watershed between site 1 and site 2 to delivery loading at site 2 ratios increased in wet period.

Effect of loading time on marginal bone loss around hydroxyapatite-coated implants

  • Kim, Young-Kyun;Ahn, Kyo-Jin;Yun, Pil-Young;Kim, Minkyoung;Yang, Hong-So;Yi, Yang-Jin;Bae, Ji-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.4
    • /
    • pp.161-167
    • /
    • 2013
  • Objectives: The objective of this study is compare the rate of marginal bone resorption around hydroxyapatite-coated implants given different loading times in order to evaluate their stability. Materials and Methods: The study was conducted retrospectively for one year, targeting 41 patients whose treatment areas were the posterior maxilla and the mandible. Osstem TS III HA (Osstem Implant Co., Busan, Korea) and Zimmer TSV-HA (Zimmer Dental, Carlsbad, CA, USA), which employ the new hydroxyapatite coating technique, were used. The patients were divided into two groups - immediate and delayed loading - and the bone level at the time of loading commencement and after one year of loading was measured using periapical radiography. Differences between the groups were evaluated using Mann-Whitney (${\alpha}$=0.05). Results: For all patients as a single group, the survival rate of the implants was 100%, and the mean marginal bone loss was $0.26{\pm}0.59mm$. In comparison of the differences by loading, mean marginal bone loss of $0.32{\pm}0.69mm$ was recorded for the immediate loading group whereas the delayed loading group had mean marginal bone loss of $0.16{\pm}0.42mm$. However, the difference was not significant (P>0.05). Conclusion: Within the limited observation period of one year, predictable survival rates can be expected when using immediately loaded hydroxyapatite-coated implants.

The effect of loading time on the stability of mini-implant (교정력 부하시기에 따른 교정용 미니 임플란트의 안정성)

  • Lee, Seung-Yeon;Cha, Jung-Yul;Yoon, Tae-Min;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.149-158
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the stability of mini-implants in relation to loading time. Methods: A total of 48 mini-implants (ORLUS, Ortholution, Korea) were placed into the buccal alveolar bone of the mandible in 8 male beagle dogs. Orthodontic force (200-250gm) was applied immediately for the immediate loading group while force application was delayed for 3 weeks in the delayed loading group. For the subsequent loading periods (3, 6, 12 weeks), BIC (bone implant contact) and BV/TV (bone volume/total volume) and mobility test were carried out. Results: The immediate loading group showed no changes in BIC from 3 to 12 weeks, while the delayed loading group showed a significant increase in BIC between 3 and 12 weeks (p<0.05). The BV/TO of the delayed loading group significantly increased from 6 to 12 weeks of loading (p<0.05), while the BV/TV of the immediate loading group decreased from 3 to 12 weeks of loading. However, there was no significant difference in BV/TV between experimental groups. The mobility of the immediate loading group was not significantly different from that of the delayed loading group after 12 weeks of loading (p<0.05). Conclusions: These results showed that immediate loading does not have a negative effect on the stability of mini-implants compared to the early loading method in both the clinical and histomorphometric point of view.

Results of immediate loading for implant restoration in partially edentulous patients: a 6-month preliminary prospective study using SinusQuickTM EB implant system

  • Kim, Jong-Hwa;Kim, Young-Kyun;Yi, Yang-Jin;Yun, Pil-Young;Lee, Hyo-Jung;Kim, Myung-Jin;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.136-139
    • /
    • 2009
  • STATEMENT OF PROBLEM. Many dental clinicians are concerned about immediate loading of inserted implants. However, there have been few clinical studies surveying the success rates of immediate loading, based on Korean implant systems. PURPOSE. The aim of this study was to evaluate the outcome of immediate functional loading of the implant ($SinusQuick^{TM}$EB, Neobiotech Co., Seoul, Korea) in partially edentulous maxilla or mandible. MATERIAL AND METHODS. Total 15 implants were placed. Within 2 weeks after implant insertion, provisional implant-supported fixed partial dentures were delivered to the patients. Quantitatively, marginal bone loss was measured at the time of immediate loading, after 3-months of continued loading and at the last follow-up. The mean follow-up period was 4.8 months. RESULTS. Mean marginal bone loss from implant surgery to early loading, 3-months follow-up and last follow-up was $0.03\pm0.07$ mm, $0.16\pm0.17$ mm and $0.29\pm0.19$ mm. No implant failed up to 6 months after insertion, resulting in a 100% survival rate. CONCLUSION. Immediate loading exhibited high success rate in partial edentulism for up to 6 months. Well-controlled long term clinical studies with large sample size are necessary to confirm this finding.

A Stochastic Analysis of the Water Quality with Discharge Variation in Upper Nakdong River Basin (낙동강 상류 유역에서의 유량변동에 따른 수질의 통계학적 분석)

  • Choi, Hyun Gu;Han, Kun Yeun;Choi, Seung Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.833-843
    • /
    • 2011
  • The purpose of this study is to analysis pollutant loading of upper Nakdong River basin according to the variation of discharge. The correlation between discharge and pollutant concentration and between discharge and pollutant loading were analyzed by statistical method, respectively. Regression equation of pollutant loading and discharge was represented as $L=_aQ^b$ in which L = pollutant loading(kg/day), and b = regression coefficients, and Q = discharge($m^3/day$). The correlation coefficient of study area was in range of 0.8428 to 0.9935. The SS was the highest b value 1.2856~1.7730 among water quality parameters because the pollutant loading of SS was much affected by flow. Additionally, the applicability of the regression equations was verified by comparing predicted results with observed value. The correlation coefficient of verification was in range of 0.8983 to 0.9987 and NSEC was in range of 0.7018 to 0.9960. Therefore the pollutant loading was good correlated with discharge. The main result will be used as basic data for water quality management and design of environment fundamental facilities.

Loading rate effect on the delamination toughness of carbon/epoxy composites (하중속도가 탄소섬유/에폭시 적층복합재의 층간분리인성에 미치는 영향)

  • Ha S.R.;Rhee K.Y.;Kim H.J.;Jung D.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.593-597
    • /
    • 2005
  • It is generally accepted that fracture toughness of fiber-reinforced polymer composites is affected by loading rate in an atmospheric presure condition. For a present study, the loading rate effect on the fracture toughness of fiber-reinforced laminated composites in the hydrostatic pressure condition was investigated. For this purpose, fracture tests have been conducted using carbon/epoxy composites applying three steps of the strain rate at 270 MPa hydrostatic pressure condition. The loading rates applied were 0.05%/sec, 0.25%/sec, and 0.55%/sec. Fracture toughness was determined from the work factor approach as a function of applied loading rate. The result showed that fracture toughness decreased as the loading rate increased. Specifically, the fracture toughness decreased 12% as the loading rate increased from 0.05%/sec to 0.55%/sec.

  • PDF

Effect of Taping Therapy for Increasing the weight loading on Affected Leg of Hemiparesis (테이핑요법을 통한 중풍 편마비환자의 환측 하지체중부하율 변화에 대한 임상연구)

  • Han, Soon-Hyun;Kim, Sung-Soo;Ryu, Han-Jin
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.4 no.1
    • /
    • pp.67-73
    • /
    • 2003
  • Objective: In order to study the effect of Taping Therapy for Increasing the weight loading on Affected Leg of Hemiparesis, a clinical study was performed. Method: Tapes were applied on gluteus medius and quadriceps femoris muscle. Weight loading on the Affected Leg of Hemiparesis was measured by two digital scales at before and after, after 30 minites, after 1 hour of treatment. From each score of two scales, we calculate the percentage of Weight loading on the Affected Leg of hemiparesis. Result: (1)Case 1: Only the percentage of Weight loading measured after treatment is effectively increased(from $47.38{\pm}0.99$ to $46.36{\pm}1.2$(p<0.05)) (2)Case 2: The percentage of Weight loading measured both after treatment and after 30 minute is effectively increased(the one is increased from $10.75{\pm}0.476$ to $12.04{\pm}1.717$ and the other is increased from $10.75{\pm}0.476$ to $15.09{\pm}2.454(p<0.05)$) (3)Case 3: The percentage of Weight loading measured at all times is effectively increased. (the one after treatment is increased from $31.59{\pm}0.606$ to $29.55{\pm}2.296$. the one after 30 minutes. is increased from $31.59{\pm}0.606$ to $45.40{\pm}0.86$, from the one after 1 hour is increased from $31.59{\pm}0.606$ to $52.70{\pm}0.541$(p<0.05)) Conclusion: (1)The percentage of Weight loading measured after treatment is effectively increased (2)The percentage of Weight loading measured after 30 minutes and 1 hour is effectively increased, so it means Taping Therapy is continueously effective. (3)The percentage of Weight loading is especialy increased when the Percentage of weight loading is near 30%

  • PDF