• Title/Summary/Keyword: $J_0$성분

Search Result 254, Processing Time 0.028 seconds

Analysis of Refractive Errors of the before and after Cataract Surgery by Auto-refractor (안굴절계를 이용한 백내장 수술전후의 굴절이상 분석)

  • Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.65-69
    • /
    • 2016
  • We investigated refractive errors and corneal power with 3 factors such as M, $J_0$, and $J_{45}$ as power vector to find out the changes of refractive errors of the before and after cataract surgery in 119 adults aged 45~85 years with cataract. After the surgery, the 3 factors were changed as $-0.29{\pm}2.38D$ to $-0.18{\pm}0.69D$ in spherical equivalent power which is the M factor, $-0.34{\pm}0.68D$ to $-0.05{\pm}0.42D$ in the $J_0$ factor, and $0.11{\pm}0.45$ to $0.02{\pm}0.17$ in the $J_{45}$ factor. Before and after the surgery, corneal mean refractive power, $J_0$, and $J_{45}$ were changed from $44.11{\pm}1.61D$ to $44.20{\pm}1.58D$, $0.01{\pm}0.50D$ to $0.08{\pm}0.49D$, and $0.02{\pm}0.29$ to $0.08{\pm}0.49$, respectively. The results showed that $J_0$ was the highest relativeness in correlation of the pre- and post-surgery for refractive errors, mean corneal power was the highest correlation for corneal power factor, and corneal power factor was the higher correlation much more than refractive error factor.

Clinical Study on Measurement Accuracy of Astigmatic Components (난시성분의 측정 정확도에 관한 임상적 연구)

  • Yoo, Jong-Sook;Sung, A-Young;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • Clinical evaluation by Astigmatic Components of autorefractors was performed to examine validity and accuracy compared with subjective refraction. The mean cylindrical powers of Astigmatic Components of Subjective Refraction, Closed-view and Open-view were found to be $-0.689{\pm}0.516D$, $-0.691{\pm}0.530D$, $-0.470{\pm}0.507D$, respectively. The Difference of cylindrical Components between Subjective Refraction and Closed, Open-view were found to be $0.002{\pm}0.191D$, $0.015{\pm}0.137D$, respectively. Approximately 85% of Closed-view and Open-view autorefractor measurements were within ${\pm}20^{\circ}$ range of the difference of cylindrical axis with subjective refraction. The mean $J_0$ Components of Astigmatic Components of subjective refraction, Closed-view and Open-view were found to be $-0.155{\pm}0.332D$, $-0.004{\pm}0.178D$, $-0.001{\pm}0.156D$, respectively. The mean $J_{45}$ Components of Astigmatic Components, Closed-view and Open-view were found to be $-0.023{\pm}0.227D$, $-0.026{\pm}0.172D$, $-0.014{\pm}0.182D$, respectively. Both of the Closed-view and Open-view refractor showed available accuracy in measuring astigmatic components.

  • PDF

Comparison of Accuracy for Autorefraction according to Measuring methods (측정방식에 따른 자동굴절검사의 정확도 비교)

  • Jeong, Youn Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.353-359
    • /
    • 2018
  • In this study, the performance between subjective refraction and open-field/closed view autorefraction was estimated. We measured the refractive error of early adults aged 18 to 20 years who did not have eye disease. The differences between measurements obtained by subjective refraction and open-field autorefraction for SE, J0, and J45 were $-0.13{\pm}0.53D$ (p=0.17), $+0.33{\pm}0.68D$ (p=0.01), and $+0.13{\pm}0.68D$ (p=0.26), respectively, with only J0 differing significantly. The differences between the measurements of subjective refraction and closed-view autorefraction for SE, J0, and J45 were $-0.30{\pm}0.42D$ (p=0.00), $+0.30{\pm}0.71D$ (p=0.02), and $-0.02{\pm}0.63D$ (p=0.88), respectively, with only SE and J0 differing significantly. The coefficient of accuracy for SE, J0, and J45 components of open-field and closed-view autorefraction were 1.04, 1.33, and 1.34 and 0.83, 1.40, and 1.24, respectively. It is possible to predict the refractive error, which is necessary when deciding on subjective refraction, by measuring the objective refraction of open-field/closed view autorefractors.

Comparison of Volatile Flavor Compounds in Bokbunja [Rubus coreanus Miquel] Wines With and Without Mushroom Extracts (일반 복분자주와 버섯 추줄물을 함유한 복분자주의 향기성분 비교)

  • Shin, H.J.;Nam, H.G.;Lim, I.J.;Cha, W.S.
    • KSBB Journal
    • /
    • v.21 no.6 s.101
    • /
    • pp.410-413
    • /
    • 2006
  • The composition of two Bokbunja (Rubus coreanus Miquel) wines (one without mushroom extracts (wine A) and the other is with the extracts (wine B)) has been investigated to improve the quality of Bokbunja wine. The content of solid particle, acidity, crude ash, crude protein of the wine A were 10.5%, 1.36%, 0.45% and 0.05% and those of wine B were 7.4%, 0.54%, 0.31%, and 0.22%, respectively. Crude fat and crude fiber were not detected in both samples. To verify the flavor quality of Bokbunja wine, the volatile components from ethylether extracts of two wines were analyzed using GC/FID and GC/MS. A total number of 12 volatile flavor compounds (6 alcohols, 3 ketones, 1 acid, 1 ester and 1 anhydride) were identified in the two Rubus wines. The major volatile compounds of the wines were 2,3-butanediol, 2,5-furanedione, phenylethyl alcohol, and butanedioic acid and they might affect the major role in the unique flavor of Bokbunja wines.

Determination Factors Affecting the High Order Aberrations in Preoperative and Postoperative LASEK (라섹 수술 전과 후의 고위수차에 영향을 미치는 결정변수)

  • Kim, Tae-Heung;Lee, Hyun;Rhee, Kang-Oh;Lee, Tae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5621-5627
    • /
    • 2014
  • To specify the standard of LASEK surgery, this study examined the determination factors affecting the high order aberrations (HOAs) in preoperative and postoperative LASEK. 51 adult patients (102 eyes) were evaluated at the baseline and 2 months after LASEK surgery from Nov 2011 to Jul 2012. The postoperative HOAs ($0.538{\mu}m$) were higher than the preoperative ($0.341{\mu}m$). In linear regression analysis, the refractive components that affected the postoperative HOAs were $J_0$ of corneal astigmatism (CA, 0.400), $J_0$ of refractive astigmatism (RA, 0.389), corneal astigmatism (CA, 0.282), spherical equivalent (SE, 0.239), refractive astigmatism (RA, 0.213), and pupil size (PS, 0.194) with a high R. In multiple regression, $J_0$ of CA, PS and SE were significant factors with the postoperative HOAs. In conclusion, both HOAs and $J_0$ of CA should be considered when determining the suitable factors for LASEK surgery.

The Horse Manure Fertilizers and Pollutants Characteristics Analysis Research (말 분뇨의 비료성분 및 오염물질 특성 조사 연구)

  • Kwag, J.H.;Jeong, M.W.;Choi, D.Y.;Kim, J.H.;Kim, Y.H.;Park, J.C.;Kim, I.C.;Yang, C.B.;La, C.C.
    • Journal of Animal Environmental Science
    • /
    • v.18 no.3
    • /
    • pp.201-206
    • /
    • 2012
  • Horse manure general composition and contaminants, heavy metals content analysis was investigated as follows. The moisture content of horse feces was 76.1% and 96% for horse urine. The average T-N, T-P, T-K concentrations of the racing horse were 0.18%, 0.10%, 0.22% respectively and 2.88%, 0.0015%, 0.84% for urine. And the average BODs, COD, SS concentrations were 26,906 $mg/{\ell}$, 36,642 $mg/{\ell}$, 89,375 $mg/{\ell}$ respectively and 14,298 $mg/{\ell}$, 7,484 $mg/{\ell}$, 6,987 $mg/{\ell}$ for urine. In addition, the Cr, Cu, Ni, Cd, Pb, Zn concentrations of feces were 2.65 mg/kg, 7.05 mg/kg, 1.24 mg/kg, 0.07 mg/kg, 0.01 mg/kg, 45.11 mg/kg respectively and 1.52 mg/kg, 1.62 mg/kg, 0.00 mg/kg, 0.03 mg/kg, 0.03 mg/kg, 4.49 mg/kg for urine on the fresh matter basis. The end of the survey was that the quality of the compost can be used as a raw material, and manure is necessary to constantly driven forward horse manure composting research.

Comparison of breathing air samples between smoker and non-smoker by means of aromatic volatile organic compounds (VOC) (방향족 유기화합물의 농도를 이용한 흡연자와 금연자의 호흡공기 조성 비교)

  • Kim, K.H.;Im, M.S.;Choe, Y.J.;Hong, Y.J;Lee, J.H.
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.431-435
    • /
    • 2005
  • In order to evaluate the hazardous effects of environmental tobacco smoking (ETS), we measured the concentrations of major aromatic VOC from those who decided to participate in a program to quit smoking. By acquiring the air samples both before and after quitting smoking (QS), we were able to compare their BTEX concentration levels in their breathing air. The results of our study clearly showed that BTEX levels in respiring air samples were significantly high prior to the QS period. It was found that toluene maintained the highest concentration levels both before and after the QS period. However, the level of reduction was most significant in the case of benzene, as it was decreased 10 times from 4.8 to 0.46 ppb. When their reduced BTEX levels are compared to those who never smoked before, differences were not significant enough to distinguish in statistical terms. The overall results of this preliminary study suggest that BTEX levels in breathing air samples can be used as one of the most sensitive signals to judge the effect of QS.

Phenotypic Correlation between Carcass Traits and Serum Profiles taken Before and After Slaughter of Hanwoo Bulls and Steers (가축에서 시기별 혈액 성분과 도체 형질에 대한 표현형 상관에 관한 연구)

  • Jeon G. J.;Choy Y. H.;Cho K. H.;Kim M. J.;Kim H. C.;Choi J. G.;Lee C. W.;Hwang J. M.;Kim J. B.
    • Journal of Embryo Transfer
    • /
    • v.20 no.3
    • /
    • pp.239-253
    • /
    • 2005
  • Serum concentrations of Hanwoo steers and bulls as possible indicators of beef quality were analyzed to estimate their correlations with carcass traits. Blood samples were taken 2 months and right before shipping to abattoir and at the time of slaughter. And phenotypic correlation coefficients between serum concentrations and carcass traits were estimated. Beef yield index of steers was positively correlated with serum concentrations of total Protein (0.23), albumin (0.26), and calcium (0.31). But it was negatively co..elated with BUN (-0.30). Loin eye area was positively correlated with BUN (0.17) or with globulin (0.16). Back fat thickness was positively correlated with BUN (0.42) and inorganic phosphorus (0.20) being negatively correlated with total protein (-0.23), albumin (-0.33) and calcium (-0.33). Marbling score in the scale of 1 (scarcely marbled) through 9 (extremely marbled) was positively correlated with BUN (0.28) and negatively with IGF-I and calcium concentrations. Phenotype correlation coefficient of loin eye area with total protein concentration in the serum taken from steers right before shipment was estimated to be -0.16 and that with BUN was estimated to be -0.15. Serum concentrations of IGF, glucose, creatinine and on organic phosphorus from steers measured right before shipment were negatively correlated with respective correlation coefficient estimates as -0.21, -0.21, -0.19 and -0.18. Marbling score was negatively co..elated with serum creatinine (-0.16) measured at that time. Beef yield index of steers was positively correlated (0.31) with age adjusted calcium concentration in the serum taken at the time of slaughter. Correlation between body weight and BUN at slaughter was 0.17 At slaughter, loin eye area was negatively correlated with albumin (-0.19) and back fat thickness was also negatively correlated with age adjusted calcium concentration (-0.38). Marbling was negatively correlated with age adjusted calcium concentration(-0.17). Serum concentrations of testosterone, calcium and inorganic phosphorus taken in 2 months before slaughter were negatively but highly correlated with yield index(0.71, 0.67 and -0.71), respectively. Body weight at slaughter was positively was negatively correlated (0.67) with calcium level while dressing percentage was negatively (-0.69) correlated with serum glucose concentration, 2 months prior to slaughter. Correlation coefficients between back fat thickness and cortisol, between back fat thickness and inorganic phosphate were both positive (0.29 and 0.69). Marbling score was negatively correlated with creatinine (-0.81) and positively with BUN (0.87). Body weight loss during shipping was positively correlated with albumin and inorganic phosphate (0.77, 0.83). Yield index of bulls was positively correlated with serum testosterone concentration (0.66). Dressing percentage was positively and highly correlated with globulin (0.73). Back fat thickness of bulls, however, was negatively correlated with testosterone (-0.60). Loin eye area of bull carcasses was positively correlated with testosterone (0.40). Mar-blaine was negatively co..elated with creatinine (-0.55). Yield index of bulls and age adjusted HDLC concentration at slaughter was negatively correlated (-0.71). Dressing percentage of bulls was positively and highly correlated with globulin concentration (0.70). Back fat thickness was also positively correlated with HDLC (0.69) in the serum taken at slaughter. Correlation coefficients between carcass weight and triglyceride, between loin eye are and testosterone and between marbling score and creatinine or glucose were 0.51, -0.91 and -0.58, respectively.

Basic Study on the Development of Analytical Instrument for Liquid Pig Manure Component Using Near Infra-Red Spectroscopy (근적외선 분광법을 이용한 돈분뇨 액비 성분분석기 개발을 위한 기초 연구)

  • Choi, D.Y.;Kwag, J.H.;Park, C.H.;Jeong, K.H.;Kim, J.H.;Song, J.I.;Yoo, Y.H.;Chung, M.S.;Yang, C.B.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.113-120
    • /
    • 2007
  • This study was conducted to measure Nitrogen(N), Phosphate($P_2O_5$), Potassium ($K_2O$), Organic matter(OM) and Moisture content of liquid pig manure by Near Infrared Spectroscopy(NIRS) and to develop an alternative and analytical instrument which are used for measurement of N, $P_2O_5$, $K_2O$, OM, and Moisture contents for liquid pig manure. The liquid pig manure sample's transmittance spectra were measured with a NIRS in the wavelength range of 400 to 2,500 nm. Multiple linear regression and partial least square regression were used for calibrations. The correlation coefficient(RSQ) and standard error of calibration(SEC) obtained for nitrogen were 0.9190 and 2.1649, respectively. The RSQ for phosphate, potassium, organic matter and moisture contents were 0.9749, 0.5046, 0.9883 and 0.9777, and the SEC were 0.5019, 1.9252, 0.1180 and 0.0789, respectively. These results are indications of the rapid determination of components of liquid pig manure through the NIR analysis. The simple analytical instrument for liquid pig manure consisted of a tungsten halogen lamp for light source, a sample holder, a quartz cell, a SM 301 spectrometer for spectrum analyzer, a power supply, an electronics, a computer and a software. Results showed that the simple analytical instrument that was developed can approximately predict the phosphate, organic matter and moisture content of the liquid pig manure when compared to the analysis taken by NIRS. The low predictability value of potassium however, needs further investigation. Generally, the experiment proved that the simple analytical instrument was reliable, feasible and practical for analyzing liquid pig manure.

  • PDF

Component Analysis of Suaeda asparagoides Extracts (나문재 추출물의 성분 분석)

  • Yang, Hee-Jung;Park, Soo-Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.3
    • /
    • pp.157-165
    • /
    • 2008
  • In the previous study, the anti-oxidant activity of oxtract/fraction of Sueada aspparagoides(SA) and the stability test for the cream containing SA extract were investigated respectively[1,2]. In this study, the components of SA extract were analyzed by TLC, HPLC, and LC/ESI-MS/MS, $^1H$-NMR. TLC chromatogram of ethyl acetate fraction of SA extract revealed 5 bands $(SA1{\sim}SA5)$. HPLC chromatogram of aglycone fractions obtained from deglycoylation reaction of ethyl acetate fraction showed 2 bands (SAA 2 and SAA 1), which were identified as quercetin (composition ratio, 16.88%) and kaempferol (83.12%) in the order of elution time. Among 5 bands of TLC chromatogram, 4 bands $(SA2{\sim}SA5)$ also were Identified as kaempferol-3-O-glucoside (SA 2), quercetin-3-O-glucoside (SA3), kaempferol-3-O-rutinoside (SA 4), quercetin-3-O-rutinoside (SA 5) by LC/ESI-MS/MSMS/MS. respectively. The spectrum generated for SAA 1 by LC/ESI-MS/MS in the negative ion mode also gave the ion corresponding to the deprotonated aglycone $[M-H]^-$ (285m/z), the $^1H$-NMR spectrum contained signals [${\delta}$ 6.19 (1H, d, J=1.8Hz, H-6), ${\delta}$ 6.44 (1H, d, J=1.8Hz, H-8), ${\delta}$ 6.92 (2H, d, J=9.0Hz, H-3', 5'), ${\delta}$ 8.04 (2H, d, J=9.0Hz, H-2', 6', thus SAA 1 was identified as kaempferol. SAA 2 yielded the deprotonated agycone ion $[M-H]^-$ (301m/z), $^1H$-NMR spectrum showed signals [${\delta}$ 6.20 (1H, d, J=2.0Hz, H-6), ${\delta}$ 6.42 (1H, d, J=2.0Hz, H-8), ${\delta}$ 6.90 (1H, d, J=8.6Hz, H-5'), ${\delta}$ 7.55 (1H, dd, J=8.6, 2.2Hz, H-6'), ${\delta}$ 7.69 (1H, d, J=2.2Hz, H-2', thus SAA 2 was Identified as quercetin. In conclusion, with the anti-oxidant activity and the stability test reported previously, component analysis of SA extracts could be applicable to new cosmeceuticals.