• 제목/요약/키워드: $Implantium^{(R)}$ implant

검색결과 10건 처리시간 0.024초

($Implantium^{(R)}$) implant의 단기 생존율 및 치유 양상에 대한 연구 (The analysis of short term success rate and healing patterns of $Implantium^{(R)}$ Implant)

  • 채경준;정성민;정의원;조규성;채중규;김종관;최성호;김창성
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.683-691
    • /
    • 2006
  • This study is an analysis of distribution of patients who installed Implantium implant in Yonsei University Dental Hospital and types of implant site for about 1 years recall check and success rate. 164 implants were installed to 52 patients in this study. It shows the conclusion below. 1. Patients at the age of 40s and 50s were 65% of all implant cases and average number of implant was 4 (man), and 2.7 (woman). 75 implants were operated on maxilla and 89 were mandible. 19 implants on anterior region and 145 implants on posterior region. 2. Most distribution of bone qaulity for implant site was type III(37.2%) and bone quantity was type C(61. 7%) 3. The majority of implants were those of 10, 12mm in length (85%) and regular diameter in width (48.8%). 4. 30 implants were installed with the advanced technique-GER, window opemng, osteotome technique. 5. Two implants were removed before prosthodontic treatment due to the osseointegraton failure. The success rate was 98.8% in 15.2 months follow up period and the marginal bone loss was 0.28mm. The results provided us with basic data on patient type, implant distribution, bone condition, and survival rate. Within the limit of present study, It was concluded that Implantium implant could be used satisfactorily in various clinical situations.

수산화인회석 코팅 임플란트와 Sandblasted, Large-grit and Acid-etched Implant의 임상적 초기 안정성 비교 (Comparison of Clinical Initial Stability of Hydroxy-apatite Coated Implant and Sandblasted, Large-grit and Acid-etched Implant)

  • 임형섭;김수관;오지수
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권2호
    • /
    • pp.112-116
    • /
    • 2012
  • Purpose: This study attempts to compare the stability of hydroxy-apatite coating implant with that of sandblasted, large-grit and acid-etched surface implant at an early state of installation. Methods: 35 implants were installed in 18 patients, who had visited hospital for implant installation. The early stability at operation, 6 weeks and 12 weeks after operation using Osstell$^{TM}$ mentor (Integration Diagnostics, Savedalen, Sweden) and Periotest$^{(R)}$ (Siemens AG, Benssheim, Germany) were measured, and subsequently analyzed statistically. Results: OsstellTM mentor value of hydroxy-apatite coated implant (HAPTITE) was measured as $70.14{\pm}9.07$ at the stage of installation, $76.98{\pm}5.25$ at 6 weeks and $80.28{\pm}4.23$ at 12 weeks after installation. A statistically significant increase in measurement value was observed after 6 weeks and 12 weeks than when implants were placed. In case of IMPLANTIUM (DENTIUM Co. Ltd., Seoul, Korea), the measurement value was $74.68{\pm}7.42$ at installation, $79.03{\pm}4.39$ at 6 weeks and $80.59{\pm}3.59$ at 12 weeks after installation. In addition, a statistically significant increase in the value was observed when comparative analysis of the value at after installation and 12 weeks after installation was carried out. However, no significant difference between HAPTITE and IMPLANTIUM was observed. The average measurement value of periotest$^{(R)}$ was $-1.94{\pm}3.90$ at installation of HAPTITE, $-4.03{\pm}1.48$ at 6 weeks and $-5.00{\pm}1.71$ at 12 weeks after installation. Moreover, whilst comparing the value at after installation and 12 weeks after installation, statistically significant decrease in the value was observed. In case of IMPLANTIUM, the average measurement value was measured as $-4.25{\pm}1.76$ at installation, $-4.76{\pm}0.97$ at 6 weeks and $-5.18{\pm}0.91$ at 12 weeks after installation and no statistically significant difference was observed. Furthermore, no statistically significant difference was observed between HAPTITE and IMPLANTIUM. Conclusion: In this study, both the implants demonstrated favorable early stability at the time of measurement using Osstell$^{TM}$ mentor and Periotest$^{(R)}$. Moreover, based on the observed results, both HAPTITE and IMPLANTIUM are considered as potent to exhibit clinically stable and prognostic results.

임플란트의 표면조도가 골융합에 미치는 영향 (Bone-to-Implant Contact according to the Surface Roughness of the Implants)

  • 최귀현;허익;이만섭;권영혁
    • Journal of Periodontal and Implant Science
    • /
    • 제33권4호
    • /
    • pp.717-728
    • /
    • 2003
  • This study was performed to evaluate the difference of the bone-to-implant contact according to the surface roughness of the implants. Two beagles were used in the experiment. Extraction of the all premolars was performed in the mandible. In 3 months of healing, screw-shaped pure titanium machined surface implants (Implantium(R), Dentium Co. Korea), implants blasted with 45${\mu}m$ $TiO_2$ particles, (Implantium(R), Dentium Co. Korea) and implants blasted with 100${\mu}m$ $TiO_2$ particles (Implantium(R), Dentium Co. Korea) in diameter 3.4mm and length 6mm were installed in the edentulous mandible. Each dog was sacrificed at 4, 12 weeks after placement and then nondecalcified specimens were prepared for histologic analysis. The results of this study were as follows. 1. At 4 , 12 weeks after the surgery, bone-to-implant contact in the surface blasted with $TiO_2$ particles was higher than that in the pure titanium machined surface respectively. 2. Osseointegration in the surface blasted with 45${\mu}m$ $TiO_2$ particles was more increased than that in the surface blasted with 100${\mu}m$ $TiO_2$ particles. 3. Bone-to-implant contact was increased with time independent of surface roughness. 4. Bone formation was in the outfolded area more than inside the threads independent of surface roughness. From the above results, we were able t o find the most bone-to-implant contact in 45${\mu}m$ $TiO_2$ blasted implant.

SLA 표면 처리와 미세나사선을 가진 내측 연결형의 국산 임플란트에 대한 후향적 연구 (Retrospective study of the $Implantium^{(R)}$ implant with a SLA surface and internal connection with microthreads)

  • 도레미;문홍석;심준성;이근우
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.136-147
    • /
    • 2009
  • 연구목적: 골유착이라는 개념이 도입된 후, 임플란트의 등장은 치과계에 많은 변화를 일으키게 되었다. 임플란트를 이용한 상실치아의 수복은 안정된 시술방법으로 시행되어져 왔으며 그 적용 범위가 확대되었고 사용 빈도도 급격히 증가해왔다. 이에 따라 국산 임플란트의 사용 빈도도 높아지고 그 종류 또한 증가하였으나 장기간의 임상적, 객관적인 자료를 가진 국산 임플란트의 수는 많지 않은 상태이다. 본 연구는 연세대학교 치과대학 병원에 내원한 환자 중 SLA 표면 처리 및 미세나사선을 가진 내측 연결형의 $Implantium^{(R)}$ 임플란트를 이용하여 치료받은 38명의 환자에게 식립된 106개의 임플란트를 대상으로 6개월에서 30개월까지의 임상적, 방사선학적 결과를 후향적으로 분석하였다. 연구재료 및 방법: 진료기록부를 통해 성별, 연령, 식립 위치, 식립 부위의 골 상태, 식립된 임플란트의 직경 및 길이, 2차수술및골이식여부, 대합치의 유형, 임상적 합병증의 유형 및 빈도 등을 조사하여 그에 따른 분포 및 생존율의 차이와 함께 이들 항목이 변연골 흡수량에 미치는 영향을 조사하였다. 방사선 사진분석으로 임플란트 식립시, 보철물 장착 후 첫 6개월 내지 1년간, 그 이후 연간 변연골 흡수량을 측정하여 분석하였다. 결과: 1. 총 38명에게 식립된 106개의 임플란트 중 1개가 실패하여 누적 생존율은 99.1%로 나타났다. 2. 보철물 장착 후 최소 6개월 이상 정기검진이 가능했던 96개의 임플란트에서 상악에서의 생존율이 97.0%, 하악에서의 생존율은 100%였고, 구치부에서의 생존율은 98.9%였으며 전치부에서의 생존율은 100%였다. 3. 보철물 장착 후 첫 1년간의 변연골 흡수량은 평균 0.17 mm 이었으며, 1년 이후의 연간 변연골 흡수량은 평균 0.04 mm로 통계학적으로 유의차 있게 적은 골소실량을 나타내었다(P<.05). 4. 보철물 장착 후 첫 1년간 연령에 따른 변연골 흡수량의 차이는 보이지 않았으나(P>.05), 1년 이후의 정기 검진 기간에서 50세 이상의 환자에서 50세 미만의 환자보다 큰 연간 변연골 흡수량을 보였다(P<.05). 5. 성별 간, 악궁 간, 전치부와 구치부위 간, 2차 수술 및 골 이식 여부, 보철물의 유형, 대합치의 유형에 따른 변연골 흡수량의 차이는 보이지 않았다(P>.05). 결론: 이상의 결과를 토대로 변연골 흡수량에 영향을 주는 요소로 연령을 들 수 있었으며 성별, 악궁 간, 악궁 내 위치, 2차 수술 및 골 이식 여부, 보철물의 유형, 대합치의 유형에 따른 변연골 흡수량의 차이는 없었다. 본 연구에서 최대 30개월까지의 기간 동안 SLA 표면 처리 및 미세나사선을 가진 내측 연결형의 국산 임플란트의 임상적인 성공률은 만족스러운 결과를 보였으며 변연골 흡수량도 임플란트 성공 기준에 부합하였다.

Sandblasted, Large-grit and Acid-etched Implant에 대한 후향적 임상 연구 (Retrospective Study of Sandblasted, Large-grit and Acid-etched Implant)

  • 조지호;김수관;문성용;오지수;박진주;정종원;윤대웅;양성수;정미애
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권4호
    • /
    • pp.352-358
    • /
    • 2011
  • Purpose: This study evaluated the prognosis and survival rate of SLA (Sandblasted, Large-grit and Acid-etched) implants and it also evaluated the prosthodontic complications and the associated factors. Methods: Twenty seven patients (14 men and 13 women, mean age: 54.9) who visited Chosun University Hospital Implant Center with the chief desire for placement of an implant in an edentulous area from March, 2008 to December 2008 and who received placement of a SLA implant ($Implantium^{(R)}$, Dentium Co., Korea) were selected for this study. Results: The average follow-up period was 15 months and the study was based on the treatment records, radiographs and clinical examinations. A total of 69 implant cases were retrospectively assessed for the width and length of the implant, the primary and secondary stability, the combined surgery, the employed bone graft material and barrier membrane, the status of the opposing tooth, implant failure and the prosthetic complications. During the follow-up period (average: 15 months), the accumulative survival rate of the 69 implants in 27 patients was 100%. Complications such as infection, sinusitis and fixture exposure after surgery were seen for 5 implants in 4 patients. Complications such as screw loosening, contact loosening and peri-implant gingivitis after prosthodontic treatment occurred in 7 cases (10.14%). Conclusion: This study reports placement of SLA implants may cause various complications, yet the final accumulative survival rate was 100%. The SLA implant ($Implantium^{(R)}$) has an excellent clinical survival rate and outcome.

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

임플란트의 직경, 길이 및 디자인변화가 임플란트 안정성지수(ISQ)에 미치는 영향 (The influence of implant diameter, length and design changes on implant stability quotient (ISQ) value in artificial bone)

  • 이정열;이원창;김민수;김종은;신상완
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.292-298
    • /
    • 2012
  • 연구 목적: 이 연구의 목적은 임플란트의 직경, 길이 및 디자인의 변화가 임플란트 안정성 지수에 미치는 영향을 비교하는 것이다. 연구 재료 및 방법: 골질차이에 의한 변수를 제거하기 위해 상악골 평균밀도와 유사한 균일한(0.48g /$cm^3$) 밀도를 가진 Polyuretane foam blocks (Sawbones$^{(R)}$, Pacific Research Laboratories Inc, Vashon, Washington)을 이용, 임플란트(Implantium$^{(R)}$, Dentium, Seoul, Korea)를 다양한 직경(${\phi}3.8$, ${\phi}4.3$${\phi}4.8$)과 길이(8, 10 및 12 mm)로 식립하여 그 변화가 임플란트 안정성 지수(Implant Stability Quotient, ISQ)에 미치는 영향을 비교하였다. 또 같은 직경과 길이(${\phi}4.3{\times}10mm$)에서 submerged와 non-submerged (SimplelineII$^{(R)}$, Dentium, Seoul, Korea) 디자인이 ISQ 에 미치는 영향을 비교하였다. 식립 회전력의 영향을 배제하기 위해 동일한 35 N의 Torque로 각 실험군당 10개씩 총 60개의 임플란트를 식립하였다. Osstell$^{TM}$ mentor(Integration Diagnostic AB, Sweden)를 이용하여 공진주파수를 측정한 후 ISQ 값으로 기록하였고, 그 결과를 one-way ANOVA와 Tukey HSD test로 분석하였다(${\alpha}$=.05). 결과: 1. 임플란트 직경의 변화는 ISQ에 영향을 미치지 않았으나(P>.05), 임플란트 길이가 증가함에 따라 ISQ도 증가하였다(P<.001). 2. 임플란트 디자인의 변화는 ISQ와 유의한 상관관계를 보여 Submerged 디자인의 ISQ가 non-submerged 디자인보다 높게 나타났다(P<.05). 결론: 임플란트 안정성을 높이기 위해서는 가능한 길이가 긴 임플란트를 식립하는 것이 유리하며, 같은 길이의 임플란트에서 볼 때 Non-submerged 디자인보다 submerged 디자인이 더 높은 ISQ를 얻을 수 있을 것으로 생각된다.

임플란트 식립 유형에 따른 후향적 연구 (Retrospective studies of dental implant placement at each intraoral site and situation)

  • 홍지연;채경준;정의원;김창성;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.805-824
    • /
    • 2007
  • Purpose: Developments in micro/macrostructures of implants and surgical techniques brought out stable outcomes of implant dentistry. The aim of this study was to evaluate the distributions of implant patients, the types of implanted sites, and the success or survival rates of various implant systems and to analyze the implant placement done at each specificintraoral site and situation. Materials and Methods: The data of dental implantations collected between 1992 and 2006 at the Department of Periodontology in 00000 University Hospital were analyzed. Results: 1. Largest part of the patients were at the age of 40s and 50s in bothgender who lost their teeth mostly by periodontaldiseases and caries at the posterior intraoral sites as major ones. Bone densities of type II(mandible) and III(maxilla) were likely to be seen with quantity of type B. Lengths of the implants between 10 and 15 mm and wide platform took the largest part. 2. Survival rates of $Implantium^{(R)}(98.8%)$, $Xive^{(R)}(100%)$ and ITI $TE^{(R)}(100%)$ were high when $Frialit-2^{(R)}$ showed 82%(poor bone density area) or 87.2%(combined with additional therapy). $IMZ^{(R)}$ had lowest cumulative survival(67.5%) and success rate(49.4%) amongst all. 3. Replacement with 2 wide or 3 regular platforms showed no significant differences in survival rate and marginal bone loss atmandibular posterior area. In single restoration of mandibular second molar, 5-year success rate of machined surface $Br{\aa}nemark^{(R)}(70.37%)$ was lower than that of rough surface $ITI^{(R)}$ SLA(100%). 4. Replacement of single tooth in anterior area showed high survival rate of 94.5%. 5. The success rates of $Br{\aa}nemark$ Ti-Unite and ITI SLA at posterior maxilla with poor bone density both showed stable outcomes. 6. 10-year cumulative survival rate of implants with maxillary sinus augmentation by lateral window approach appeared to be 96.60%. Low survival rate(75%) was shown when there were more than two complications combined. Height of grafted bone remained stable above the implant apex. Conclusions : Rough surfaced implants showed stable outcomes in most of the situation including poor bone density and additional therapy combined.

임플란트 표면처리에 따른 골융합의 차이 (Comparision of Osseointegration Depending on Surface Treatment)

  • 황하준;박준봉;권영혁;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제34권4호
    • /
    • pp.699-709
    • /
    • 2004
  • The present study was performed to evaluate histomorphological difference in various surface-treated implants in beagle. Implants($Implantium^{(R)}$, Dentium Co. Korea) with pure titanium machined surface, acid treated surface, and $Al_2O_3(50{\sim}100\;{\mu}m)$blasted with acid treated surface were used in this study. All mandibular premolars of $1.5{\sim}2$ year old male beagle dogs were extracted. At 3 months after extraction, the implants(${\Phi}$ 4mm, l 6mm) were installed. The beagle were sacrificed at 1, 3 months after installation and then tissues including implants were prepared for non-decalcified specimens. These specimens were analyzed comparatively under light microscope. The results of this study were as follow 1. Higher rate of osseointegration were showed in the $Al_2O_3(50{\sim}100\;{\mu}m)$blasted with acid-treated surface. 2. Increased osseointegration were showed in the $Al_2O_3(50{\sim}100\;{\mu}m)$blasted with acidtreated surface with time. 3. Higher maturation of integration were showed in the $Al_2O_3(50{\sim}100\;{\mu}m)$blasted with acid-treated surface. In conclusion, surface treatment of $Al_2O_3blasted$ with acid might be considered to shorten healing time and improve success rate as increasing contact of implant and bone.