Browse > Article

The analysis of short term success rate and healing patterns of $Implantium^{(R)}$ Implant  

Chae, Gyung-Joon (Department of Periodontology, College of Dentistry, Yonsei University Reasearch Institute for Periodontal Regeneration)
Chung, Sung-Min (Dentium Co., Ltd.)
Jung, Ui-Won (Department of Periodontology, College of Dentistry, Yonsei University Reasearch Institute for Periodontal Regeneration)
Cho, Kyoo-Sung (Department of Periodontology, College of Dentistry, Yonsei University Reasearch Institute for Periodontal Regeneration)
Chai, Jung-Kyu (Department of Periodontology, College of Dentistry, Yonsei University Reasearch Institute for Periodontal Regeneration)
Kim, Chong-Kwan (Department of Periodontology, College of Dentistry, Yonsei University Reasearch Institute for Periodontal Regeneration)
Choi, Seong-Ho (Department of Periodontology, College of Dentistry, Yonsei University Reasearch Institute for Periodontal Regeneration)
Kim, Chang-Sung (Department of Periodontology, College of Dentistry, Yonsei University Reasearch Institute for Periodontal Regeneration)
Publication Information
Journal of Periodontal and Implant Science / v.36, no.3, 2006 , pp. 683-691 More about this Journal
Abstract
This study is an analysis of distribution of patients who installed Implantium implant in Yonsei University Dental Hospital and types of implant site for about 1 years recall check and success rate. 164 implants were installed to 52 patients in this study. It shows the conclusion below. 1. Patients at the age of 40s and 50s were 65% of all implant cases and average number of implant was 4 (man), and 2.7 (woman). 75 implants were operated on maxilla and 89 were mandible. 19 implants on anterior region and 145 implants on posterior region. 2. Most distribution of bone qaulity for implant site was type III(37.2%) and bone quantity was type C(61. 7%) 3. The majority of implants were those of 10, 12mm in length (85%) and regular diameter in width (48.8%). 4. 30 implants were installed with the advanced technique-GER, window opemng, osteotome technique. 5. Two implants were removed before prosthodontic treatment due to the osseointegraton failure. The success rate was 98.8% in 15.2 months follow up period and the marginal bone loss was 0.28mm. The results provided us with basic data on patient type, implant distribution, bone condition, and survival rate. Within the limit of present study, It was concluded that Implantium implant could be used satisfactorily in various clinical situations.
Keywords
$Implantium^{(R)}$ implant; success rate;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Pietrokovski J. The bony residual ridge in man. J Prosthet Dent 1975;34:456-462   DOI   ScienceOn
2 Henry PH, Laney W.R, Jemt T. Osseointegrated implants for single tooth replacement : a prospective 5 years multicenter study. Int J Oral Maxillofac Implants 1996;11:450-455
3 Schnitman PA, Wohrle PS, Rubenstein JE, DaSilva JD, Wang NH. Ten-year results for Branemark implants immediately loaded with fixed prosthesis implant placement. Int J Oral Maxillofac Implants 1997;12: 495-503
4 Stephen W, Use of the Frialit-2 Implant system in private practice: A clinical Report. Int J Oral Maxillofac Implants 2003;4: 552-555
5 Cochran DL. A comparison of endosseous dental implant surfaces. J Periodontol 1999;70:1523-1539   DOI   ScienceOn
6 Summers RE. A new concept in maxillary implant surgery: The osteotome technique, Compen Contin Educ Dent 1994;15:152-160
7 Hansson S. Implant-abutment interface: Biomechanical study of flat top versus conical. Clin Impl Dent Res 2000;2:33-41   DOI   ScienceOn
8 Albrektsson T. A multicenter report on osseointegrated oral implants. J Prosthet Dent. 1988;60:75-84   DOI   ScienceOn
9 Waerhaug J. Periodontology and partial prosthesis. Int Dent J 1968;18:101-107
10 Friberd B, Jemt T, Lekholm U, Early failures in 4,641 consecutively placed Branem-: ark dental implants : A study from stage 1 surgery to the connections of complete prostheses. Int J Oral Maxillofac Implants 1991;6:132-146
11 Wetherell J, Smales R. : Partial dentures failure : A long-term clinical survey. J Dent Res 1980;8:333-340   DOI   ScienceOn
12 통계청. 1999년 생명표. 2001년 8월
13 Lekholm U, Zarb G, Branemark PI, Tissue integrated prostheses Osseointegration in clinical dentistry, Chicago, Quintensence. 1985;199-209
14 Gotfredsen K, Holm B. Implant-supported mandibular overdentures retained with ball or bar attachments : A randomized prospective 5-year study. Int. J. Prosth 2000; 13:125-130
15 박지은, 윤정호, 정의원, 김창성, 최성호, 조규성, 채중규, 김종관. 임플란트 환자의 분포 및 식립부 유형. 대한 치주과학회지 2004 34(4): 819-836,
16 Carr A, Laney WR. Maximum occlusal force levels in patients with ,uosseointegrated oral implant prosthesis and patient with complete dentures. Int J Oral Maxillofac Implants 1987;2:101-110
17 Ericsson I, Nilson H, Lindh T, Nilner K, Randow K. Immediate functional loading of Branemark single tooth implants : An 18 months' clinical pilot follow-up study. Clin Oral Implants Res 2000;11:26-33   DOI   ScienceOn
18 Carlsson G, Persson G. Morphologic changes of the mandible after extraction and wearing dentures : A longitudinal clinical and x-ray cephalometric study covering 5 years. Odont Revy 1967;18:27-54
19 Wetherell J, Smales R. : Partial dentures failure : A long-term clinical survey. J Dent Res 1980;8:333-340   DOI   ScienceOn
20 R,M. Palmer, B.J, Smith, P.J. Palmer, P.D. Floyd. A retrospective study of Astra single implants. Clin Oral Impl Res 1997;8:173-179   DOI   ScienceOn
21 Atwood DA, Postextraction changes in the adult mandible as illustrated by microradiographs of midsagital sections and serial cephalometric roentgenograms. J Prosthet Dent 1963;13:810-824   DOI
22 Rosenquist JB, Grenthe B. Immediate placement of implants into extraction sockets : Implant survival. Int J Oral Maxillofac Implant 1996;11:205-209
23 Lekholm U, Gunne J, Henry P, Higuchi K, Linden U, Bergstrom C, van Steenberghe D. Survival of the Branemark implant in partially edentulous jaws: a 10-year prospective multicenter study. Int J Oral Maxillofac Implants. 1999;14:639-45
24 Jaffin RA, Berman CL. The excessive loss of Branemark fixtures in type N bone : A 5-year analysis. J Periodontol 1991; 62(1): 2-4   DOI
25 Marcus SE, Drury JF, Brown LS. Tooth retention and tooth loss in the permanent dentition of adults : United States, 1988-1991. J Dent Res 1996;75:684-695
26 Buser D, Mericske-Stern R, Bernard JP, Behneke A, Behneke N, Hirt HP, Belser UC, Lang NP, Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants, Clin Oral Implants Res. 1997 ;8:161-72   DOI   ScienceOn
27 Minsk L, Polson A, Weisgold A, Outcome failures of endosseous implant from a clinical training center. Compendium 1996;17(9) :848-859
28 Branemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969;3:81-100   DOI