• Title/Summary/Keyword: $Hg^{2+}$ sensor

Search Result 58, Processing Time 0.029 seconds

Rhodamine Based Fluorescent Chemosensors for Hg2+ and its Biological Application

  • Choi, Ji-Young;Kim, Wan-Tae;Yoon, Ju-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2359-2364
    • /
    • 2012
  • Two new chemosensors, rhodamine 6G derivative bearing hydroxyethyl group (1) and rhodamine base derivative bearing 15-crown-5 group (2) were synthesized and their sensing behaviors toward various metal ions were investigated by UV/Vis and fluorescence spectroscopies. Addition of $Hg^{2+}$ ion to a $CH_3CN$ solution of 1 and 2 gave visual color changes as well as fluorescent OFF-ON observations. Selectivity and sensitivity of 1 towards $Hg^{2+}$ are excellent enough to detect micromolar level of $Hg^{2+}$ ion, even in equeous media and biological sample (HeLa cell).

A Highly Selective Mercury(II) Ion-Selective Membrane Sensor (고 선택성 수은(II) 이온 막 센서)

  • Ensafi, Ali A.;Meghdadi, S.;Allafchian, Ali R.
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.4
    • /
    • pp.324-330
    • /
    • 2007
  • A new ion selective PVC membrane electrode is developed as a sensor for mercury(II) ions based on bis(benzoylacetone) propylenediimine (H2(BA)2PD) as an ionophore. The electrode shows good response characteristics and displays, a linear Emf vs. log[Hg2+] response over the concentration range of 1.0×10-6 to 1.0×10-1 M Hg(II) with a Nernstian slope of 29.8±0.75 mV per decade and with a detection limit of 2.2×10-7 M Hg(II) over the pH range of 2.5-11.5. Selectivity concentrations for Hg(II) relative to a number of potential interfering ions were also investigated. The sensor is highly selective for Hg(II) ions over a large number of cations with different charge. The sensor has been found to be chemically inert showing a fast response time of 60 s and was used over a period of 3 months with a good reproducibility (S = 0.27 mV). The electrode was successfully applied to determine mercury(II) in real samples with satisfactory results.

DFT 계산을 통한 dipyrene-based excimer-switch off fluorescent sensor 연구

  • Han, Dong-Uk;Mun, Jong-Hun;Park, Yeong-Geun;Lee, Jin-Yong
    • Proceeding of EDISON Challenge
    • /
    • 2014.03a
    • /
    • pp.275-285
    • /
    • 2014
  • Dipyrene-based fluorescent chemosensor(분자 1)가 개발되었다. 분자 1은 여러 금속이온 중 $Cu^{2+}$$Hg^{2+}$의 fluorescent chemosensor로서 센싱할 수 있고, excimer-switch off mechanism에 따라 $Cu^{2+}$$Hg^{2+}$ 금속이온을 감지한다. Ground state와 excited state에 대한 DFT와 TD-DFT 방법을 통해 분자 1의 $Hg^{2+}$에 대한 형광 turn on/off을 확인하고, 구조변화에 따른 molecular orbital을 계산하였다. 계산결과 분자 1은 excited state에서 excimer를 형성할 수 있으나 $1+Hg^{2+}$는 excimer를 형성하지 못함을 알 수 있었다. 여기서 우리는 분자 1과 $Hg^{2+}$ 금속이온 결합에 대하여 실험값과 비교 분석하여 그 메커니즘 조사하였다.

  • PDF

Development of Inductive and Capacitive Type Intraocular Pressure (IOP) Sensor to Improve Sensitivity and Minimize Size (민감도 향상과 센서 소형화를 위한 자기 및 용량형 안압센서의 개발)

  • Jang, Cheol In;Shin, Kyeong-Sik;Yun, Kwang-Seok;Kim, Yong Woo;Kang, Ji Yoon;Lee, Soo Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.409-415
    • /
    • 2014
  • We had presented an inductive type intraocular pressure sensor (L-sensor) in previous work. The distance between a micro coil and a ferrite on the membrane was modulated by pressure, and as a result the inductance and resonant frequency were changed. However, L-sensor has some problems to implant in eyes. First problem is low sensitivity. When L-sensor was implanted in rabbit's eyes, resonant frequency of L-sensor was very hard to detect. Second problem is biocompatibility. Size of L-sensor is $6{\times}7{\times}1.2mm$. When L-sensor was implanted in the eyes, it caused the inflammation. Therefore, this study suggests an inductive and capacitive type IOP sensor (LCsensor). The sensitivity of the LC-sensor 27.3 kHz/mmHg under 60mmHg. It is much larger than 14 kHz/mmHg of the L-sensor. And the size of LC-sensor is 47% smaller than L-sensor. After 2 weeks from the implantation of LC-sensor into rabbit eyes, we measured the changes of resonant frequency of LC-sensor according to increased IOP by Balanced Salt Solution (BSS) injection. As a result, the sensitivity of LC-sensor in in vivo test is 25 kHz/mmHg. That is similar to the sensitivity of in vitro test.

A Quinoline-thiooxorhodamine Conjugate for Fluorescent Hg2+ Recognition in Aqueous Media and Living Cells

  • Tang, Lijun;Wen, Xin;Dai, Xin;Wu, Di;Huang, Zhenlong
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3326-3330
    • /
    • 2014
  • A quinoline-thiooxorhodamine conjugate fluorescent sensor (1) has been synthesized. Sensor 1 exhibits high selectivity and sensitivity to $Hg^{2+}$ in $H_2O$/DMSO (95/5, v/v, HEPES 20 mM, pH = 7.4) solution with fluorescence detection. Other tested metal ions do not induce any significant fluorescence intensity changes. Sensor 1 interacts with $Hg^{2+}$ through a 1:1 binding stoichiometry with a good anti-inference ability. In addition, fluorescent imaging of $Hg^{2+}$ in Hela cells is also successfully demonstrated.

A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement (혈압 측정을 위한 외팔보형 접촉힘 센서 어레이)

  • Lee, Byeung-Leul;Jung, Jin-Woo;Chun, Kuk-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

Development of Pressure Sensor on Polymer Substrate for Real-time Pulse and Blood Pressure Measurements (실시간 맥박 및 혈압 측정을 위한 폴리머 기판 압력센서 개발)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.669-676
    • /
    • 2013
  • In this study, we introduce a polymer(polyimide) based pressure sensor to measure real-time heart beat and blood pressure. The sensor have been designed with consideration of skin compatibility of material, cost effectiveness, manufacturability and wireless detection. The designed sensor was composed of inductor coils and an air-gap capacitor which generate self-resonant frequency when electrical source is applied on the system. The sensor was obtained with metalization, etching, photolithography, polymer adhesive bonding and laser cutting. The fabricated sensor was shaped in circular type with 10mm diameter and 0.45 mm thickness to fit radial artery. Resonant frequencies of the fabricated sensors were in the range of 91~96 MHz on 760 mmHg pressurized environment. Also the sensor has good linearity without any pressure-frequency hysteresis. Sensitivity of the sensor was 145.5 kHz/mmHg and accuracy was less than 2 mmHg. Real-time heart beat measurement was executed with a developed hand-held measurement system. Possibility of real-time blood pressure measurement was showed with simulated artery system. After installation of the sensor on skin above radial artery, simple real blood pressure measurement was performed with 64 mmHg blood pressure variation.

Fabrication and Characterization of Miniature Si Pressure Sensor (소형 Si 압력센서의 제작 및 특성 평가)

  • Ju, Byeong-Kwon;Lee, Myoung-Bok;Lee, Jung-Il;Kim, Hyoung-Gon;Kim, Kwang-Nham;Oh, Myung-Hwan
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.11
    • /
    • pp.62-68
    • /
    • 1990
  • On the basis of standard Si processing, the miniaturized piezoresistive-type Si pressure sensor with a chip size of $1.7{\times}1.7{mm^2}$ was fabricated and its operating characteristics were investigated. The sensor chip has a full-bridge type of 4 boron-diffused resistors which is formed on an $1.0{\times}1.0{mm^2}$ area, $20{\mu}m$ thick n-type Si diaphragm and finally, encapsulated under room temperature, 1 atm in order to measure a gauge pressure. The operating characteristics of this sensor were determined as a pressure sensitivity of $14.2{\mu}$V/VmmHg, a rated pressure range of 0~760 mmHg, and a maximum nonlinearity of $1.0{\%}$ FS at room temperature.

  • PDF

A Pyrenylboronic Acid-based Fluorescence Sensor for Highly Efficient Detection of Mercury(II) Ions (효율적인 수은이온 검출을 위한 피렌-보론산 기반의 형광센서 개발)

  • Lee, Seung Yeob;Lee, Seoung Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.2
    • /
    • pp.201-207
    • /
    • 2020
  • A new chemosensor based on a self-assembled system has been devised to detect Hg2+ions efficiently. We demonstrated that the amphiphilic building blocks consisting of pyrene and boronic acid (1) aggregate in aqueous solutions and provide an outstanding sensing platform for sensitive detection. The self-assembled 1 exhibited high selectivity and sensitivity for Hg2+ion detection via fluorescence quenching, where the Hg2+ion detection ensued from a fast transmetallation of 1. The Stern-Volmer (SV) quenching constant for its fluorescence quenching by Hg2+ions was approximately 1.58 × 108 M-1. In addition, self-assembled 1 exhibited excellent sensing abilities at nano-molar concentration levels when tap water and freshwater samples were contaminated with of Hg2+ ions.