• 제목/요약/키워드: $Hg^{2+}$ ions

검색결과 213건 처리시간 0.027초

Benzothiazole-Based Semisquaraine as Colorimetric Chemosensor for $Hg^{2+}$

  • 허은영;고영일;배진석;김성훈
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2008년도 제39차 학술발표회
    • /
    • pp.83-84
    • /
    • 2008
  • A highly selective colorimetric chemosensor for $Hg^{2+}$ based on the semisquaraine(BSQ) containing benzothiazole moiety was investigated. BSQ showed color change only with $Hg^{2+}$ but it showed no significant changes upon addition of other metal ions such as $Ca^{2+},\;Pb^{2+},\;Al^{3+},\;Ce^{2+},\;Ba^{2+},\;Ni^{2+},\;Cd^{2+},\;Zn^{2+},\;and\;Mg^{2+}$. $Hg^{2+}$ ions coordinated to the BSQ forming 1:1 complex. The experimental data and conclusions are rationalized by $DMol^3$ calculation results.

  • PDF

엽록소형광분석을 이용한 담수산 클로렐라(Chlorella vulgaris)에 미치는 중금속의 영향 평가 (Assessment of Heavy Metal Effects on the Freshwater Microalga, Chlorella vulgaris, by Chlorophyll Fluorescence Analysis)

  • 오순자;고석찬
    • 한국환경과학회지
    • /
    • 제24권12호
    • /
    • pp.1591-1600
    • /
    • 2015
  • The response of the freshwater microalga, Chlorella vulgaris, to heavy metal stress was examined based on chlorophyll fluorescence analysis to assess the toxic effects of heavy metals in freshwater ecosystems. When toxic effects were analyzed using regular chlorophyll fluorescence analysis, photosystem II activity($F_v/F_m$) decreased significantly when exposed to $Cu^{2+}$ and $Hg^{2+}$ for 12 h, and decreased in the order of $Hg^{2+}>Cu^{2+}>Cd^{2+}>Ni^{2+}$ when exposed for 24h. The effective photochemical quantum yield(${\phi}{\prime}_{PSII}$), chlorophyll fluorescence decrease ratio($R_{Fd}$), minimal fluorescence yield($F_o$), and non-photochemical quenching(NPQ), but not photochemical quenching(qP), responded sensitively to $Hg^{2+}$, $Cu^{2+}$, and $Cd^{2+}$. These results suggest that $F_v/F_m$, as well as ${\phi}{\prime}_{PSII}$, $R_{Fd}$, $F_o$, and NPQ could be used to assess the effects of heavy metal ions in freshwater ecosystems. However, because many types of heavy metal ions and toxic compounds co-occur under natural conditions, it is difficult to assess heavy metal toxicity in freshwater ecosystems. When Chlorella was exposed to heavy metal ions for 12 or 24h, $F_v/F_m$ and maximal fluorescence yield($F_m$) changed in response to $Hg^{2+}$ and $Cu^{2+}$ based on image analysis. However, assessing quantitatively the toxic effects of several heavy metal ions is challenging.

Selective Mercuration of 2-Hydroxy Nile Red and Its Application towards Chemodosimetric Hg2+-selective Signaling

  • Lee, Hae-Kyung;Choi, Myung-Gil;Yu, Hyo-Yeon;Ahn, Sang-Doo;Chang, Suk-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권12호
    • /
    • pp.3539-3542
    • /
    • 2010
  • Selective mercuration at the 1,6-positions of 2-hydroxy derivative of Nile Red and its application towards $Hg^{2+}$-selective signaling was investigated. The 2-hydroxy Nile Red exhibited a selective UV-vis absorption and fluorescent signaling behavior towards $Hg^{2+}$ ions over common coexisting physiologically important metal ions in aqueous environment. $^1H$ NMR studies revealed that the mercuration was selectively effected at the 1,6-positions of 2-hydroxy Nile Red, which is quite different from that at the 6,8-positions for the parent Nile Red.

Synthesis and optical determination of chemosensor toward Cu(II) and Hg(II)

  • Yu, Hyung-Wook;Wang, Sheng;Son, Young-A
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2011년도 제44차 학술발표회
    • /
    • pp.68-68
    • /
    • 2011
  • A new chemosensor based on rhodamine B (1) for $Hg^{2+}$ and $Cu^{2+}$ was synthesized by one-step condensation reaction of rhodamine B hydrazide and Azo dye. Studying for its fluorogenic and colorimetric behaviors towards various metal ions, extreme sensitivity and selectivity were achieved by the detection of $Hg^{2+}$ and $Cu^{2+}$ over other commonly coexistent metal ions, which were accompanied by ring opening of a rhodamine spirocycle framework. In acetonitrile, the presence of $Hg^{2+}$ and $Cu^{2+}$ induces the formation of a Dye 1-ion complex, which was deduced by spectroscopy.

  • PDF

형광화학센서를 이용한 용출기반 토양 수은 오염조사 (Determination of Mercury Ion in Contaminated Soil by Rhodamine B Hydrazide)

  • 김경태;박준범
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권3호
    • /
    • pp.1-5
    • /
    • 2016
  • Rhodamine B Hydrazide as a novel fluorescent and colorimetric probe exhibiting remarkably selective fluorescence enhancement toward Hg2+ ion over other 16 metal ions is herein introduced. The probe reacts with Hg2+ ion followed by its spirolactam ring-opening to give a remarkable enhancement of absorption maximum at 550 nm as well as an enhanced fluorescence intensity at 580 nm in aqueous media. Upon titration with Hg2+ ion in various concentration of 10~200 uM, we found that the probe shows a marked color change from colorless to pink, enabling naked-eye detection toward mercury ion. In addition, in the presence of Hg2+ ion, the probe gave rise to change from non-florescence to strong orange fluorescence (Off-On) with a good linearity of R2=0.97. This preliminary results demonstrate that the fluorescent chemosensor we herein introduced can open a new strategy for marked selective and sensitive detection of mercury ions in contaminated soil containing various metal ions.

소각재 사용 모르타르중의 중금속 이온 용출에 대한 연구 (Leaching of Heavy Metal Ions in Mortar Using Municipal Waste Incinerator)

  • 문대중;임남웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.564-567
    • /
    • 2004
  • FAs and BAs indicated different chemical compositions and physical properties. Leaching of Pb in FAl and Cu in FA2 were 33.2mg/L and 5.92mg/L, these were high concentration above 30 and 2 times respectively in compared to permit level. Leaching of Hg and Cr were about 1/2 of permit level. When diatom was complexly mixed with portland cement, the 28 days compressive strength of mortar with FA2 was similar with that of control mortar. Furtherfore, leaching of heavy metal ions like as Pb, Cu, Hg, Cr was highly reduced.

  • PDF

Interaction of the Post-transition Metal Ions and New Macrocycles in Solution

  • Jung, Oh-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권6호
    • /
    • pp.687-691
    • /
    • 1993
  • Complexation of $Cd^{2+},\;Pb^{2+}\;and\;Hg^{2+}$ ions with four cryptands were studied by potentiometry and solution calorimetry in various weight percent methanol-aqueous solvent at 25${\circ}$C under $CO_2$free nitrogen atmosphere. The stabilities of the complexes were dependent on the cavity size of macrocycles. The $Hg^{2+}$ ion stability constants are higher than those of $Cd^{2+}\;and\;Pb^{2+}$ ion. All the cryptands formed complexes having 1 : 1 (metal to ligand) mole-ratio except for $Hg^{2+}-L_1$ (cryptand 1,2b: 3,5-benzo-9,14,17-trioxa-1,7-diazabicyclo-(8,5,5) heptadecane) and $Cd^{2+}-L_2$ (cryptand 2,2b: 3,5-benzo-10,13,18,21-tetraoxa-1,7-diazabicyclo (8,5,5) eicosane) complexes. $Hg^{2+}-L_1$ complex was a sandwitch type, and the $Cd^{2+}-L_2$ complex showed two stepwise reactions. Thermodynamic parameters of the $Cd^{2+}-L_2$ complex were $6.08(log\;K_1)$, -7.28 Kcal/mol $({\Delta}H_1)$, and $4.78\;(log\;K_2)$, -4.62 Kcal/mol $({\Delta}H_2)$, respectively, for 1 : 1 and 2: 1 mole-ratio. The sequences of the selectivity were increased in the order of $Hg^{2+}\;>Pb^{2+}\;>Cd^{2+}$ ion for $L_3\;and\;L_4$ macrocycles, and the $L_2$-macrocycle has a selectivity for $Cd^{2+}$ ion relative to $Zn^{2+},\;Ni^{2+},\;Pb^{2+}\;and\;Hg^{2+}$ ions. Thus, it is expected that the $L_2$ can be used as carrier for seperation of the post transition metals by macrocycles-mediated liquid membrane because $L_2$ is not soluble in water, and the difference of stability constants of the metal complexes with $L_2$ are large as compared with the other transition metal complexes. The $^1H\;and\;^{13}C-NMR studies indicated that the nitrogen atoms of cryptands have greater affinity to the post transition metal ions than the oxygen atoms, and that the planarities of the macrocycles were lost by complexation with the metal ions because of the perturbation of ring current of benzene molecule attached to macrocycles and counter-anions.

Urease 저해활성 측정 cuvette assay에 의한 중금속 이온 검출 (Detection of Heavy Metal Ions by the Cuvette Assay Measuring Urease Inhibitory Activity)

  • 김동경;박경림;강은미;박인선;김남수
    • Applied Biological Chemistry
    • /
    • 제46권2호
    • /
    • pp.74-78
    • /
    • 2003
  • Urease 활성이 중금속 이온에 의하여 저해되는 현상을 알아보기 위하여 발색시약을 사용하는 광학적인 방법으로 효소반응에 의한 암모니아 발생량을 측정하였다. 암모니아 농도에 따른 cuvette assay 시의 흡광도 중가는 암모니아 농도 3.0 mg/l 까지 직선성을 보였으며 이 때의 상관계수는 0.998(r)이었다. 중금속 이온에 의한 urease의 저해활성을 알아보기 위하여 기질에 단일 중금속 이온의 농도별 용액을 가하여 흡광도를 측정한 결과 효소의 저해도는 Hg(II)>Pb(II)>Cu(II)>Cd(II)>Zn(II) 이온의 순으로 나타났다. 한 가지의 중금속 이온 농도를 고정하고 다른 중금속 이온을 각기 다른 농도로 가하면서 urease활성을 측정하였을 때 효소의 저해도는 대체로 개별 중금속 이온에 의한 저해의 총합으로 나타났다. 상기의 결과는 본 연구의 방법이 Hg(II) 이온에 대한 선택적 검출법으로서 뿐만 아니라 여러 형태의 시료 중에 존재가능한 중금속 이온들을 정성적으로 판별하는 방법으로 활용될 수 있음을 보여주었다.

골격근 小胞體의 ATPase活性에 미치는 二價金屬이온의 영향 (Kinetic Studies on the Effects of Divalent Cations on the ATPase Activity of the Fragmented Sarcoplasmic Reticulum of Rabbit Skeletal Muscle)

  • Park, Young-Soon;Ha, Doo-Bong
    • 한국동물학회지
    • /
    • 제23권3호
    • /
    • pp.137-148
    • /
    • 1980
  • 토끼 골격근 小胞體의 ATPase 活性에 미치는 $Hg^{2+}, Cu^{2+}, Pb^{2+}, Cd^{2+}, Mn^{2+}$ 등 2價 陽이온을 영향을 비교 측정하였다. 이들 陽이온은 $Mn^{2+}$을 제외하고 모두 이 酵素의 活性을 阻害하였다. $Mn^{2+}$은 低濃度 (12.5-100 $\mu$M)에서는 오히여 活性을 증가시켰고, 그 보다 高濃度에서는 극히 약하게 阻害하였다. $Mn^{2+}$을 제외한 위의 2價 陽이온들의 阻害龍은 $Hg^2$가 가장 컸고 (阻害係數 Ki = 10$\mu$M), rm 다음이 $Cu^{2+}$ (Ki = 30$\mu$M), $Pb^{2+}$ (Ki = 120$\mu$M), $Cd^{2+}$ (Ki = 320$\mu$M)의 순이었다. 위의 4종의 陽이온들의 ATPase에 대한 阻害作用을 可逆的 非競爭的 阻害로 판정되었다.

  • PDF

Simultaneous Detection of Cd (II), Pb (II), Cu (II), and Hg (II) Ions in Dye Waste Water Using a Boron Doped Diamond Electrode with DPASV

  • Yoon, Jang-Hee;Yang, Jee-Eun;Kim, Jong-Phil;Bae, Jong-Seong;Shim, Yoon-Bo;Won, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권1호
    • /
    • pp.140-145
    • /
    • 2010
  • The simultaneous detection of Cd (II), Pb (II), Cu (II), and Hg (II) ions in aqueous medium using a BDD electrode with DPASV is described. XPS was used to characterize the chemical states of trace metal ions deposited on the BDD electrode surface. Experimental parameters that affect response, such as pH, deposition time, deposition potential, and pulse amplitude were carefully optimized. The detection limits for Cd (II), Pb (II), Cu (II), and Hg (II) ions were 3.5 ppb, 2.0 ppb, 0.1 ppb and 0.7 ppb, respectively. The application of the BDD electrode on the electrochemical pretreatment for the simultaneous metal detection in the dye waste water was also investigated.