• 제목/요약/키워드: $H_2S$ sensor

검색결과 464건 처리시간 0.026초

Novel Tm(III) Membrane Sensor Based on 2,2'-Dianiline Disulfide and Its Application for the Fluoride Monitoring of Mouth Wash Preparations

  • Ganjali, Mohammad Reza;Norouzi, Parviz;Tamaddon, Atefeh;Husain, Syed Waqif
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권9호
    • /
    • pp.1418-1422
    • /
    • 2006
  • In this work the construction of a novel poly(vinyl chloride) membrane sensor based on 2,2'-dianiline disulfide (DADS) as a neutral carrier, o-nitrophenyloctyl ether (NPOE) as a plasticizer and sodium tetraphenyl borate (NaTPB) as an anionic site with unique selectivity towards Tm(III) ions is reported. The electrode has a linear dynamic range between $1.0\;{\times}\;10^{-6}$ and $1.0\;{\times}\;10^{-2}$ M, with a nice Nernstian slope of 19.5 ${\pm}$ 0.3 mV per decade and a detection limit of $4.0\;{\times}\;10^{-7}$ M at the pH range of 4.8-8.5. It has a very fast response time (<15 s) in the whole concentration range, and can be used for at least 4 weeks without any considerable divergence in the electrode potentials. The proposed sensor revealed comparatively good selectivity with respect to most common metal ions, and especially lanthanide ions. It was used as an indicator electrode in the potentiometric titration of Tm(III) ions with EDTA and in direct determination of concentration of Tm(III) ions in binary mixtures. It was also applied in determination of fluoride ions in mouth wash preparations.

ECG-NIBP-$SpO_2$ 환자감시장치 개발 (Development of ECS-NIBP-$SpO_2$ Patient Monitoring System)

  • 김남현;심원흠;이건기;라상원;김경하
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF

Pd 촉매의 부분 산화 조절을 이용한 SnO$_2$박막 센서의 CH$_4$감도 변화 연구 (The effect of initial Pd catalyst oxidation stale on CH$_4$sensitivity of SnO$_2$thin film sensor)

  • 최원국;조정;조준식;송재훈;정형진;고석근
    • 마이크로전자및패키징학회지
    • /
    • 제6권2호
    • /
    • pp.45-49
    • /
    • 1999
  • 이온빔 보조 증착법을 이용하여 제작한 $SnO_2$박막을 기저 물질로한 가연성 센서에 catalyst로 ultra-thin Pd layer를 이온빔 스퍼터링으로 흡착시켰다. 가연성 기체의 센싱 메카니즘에서 Pd 촉매의 역할을 정확하게 조사하기 위해서 진공 및 공기 상에서 annealing 함으로서 Pd 촉매의 초기 산화 상태를 조절하였다. 촉매가 순수한 금속 Pd 클러스터 상태로 존재하는 $SnO_2$센서의 경우에는 PdO 클러스터가 있는 것에 비해 높은 감응성을 보였다. 이것은 PdO 클러스터가 표면 acceptor로 작용을 하는 것으로 생각되며 $SnO_2$로 부터 Pd sub-channel을 통해 전자를 받아 센서의 감도를 낮추고 응답시간을 늦추는 것으로 생각된다.

  • PDF

Amperometric Detection of Hydroquinone and Homogentisic Acid with Laccase Immobilized Platinum Electrode

  • Quan, De;Shin, Woon-Sup
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권6호
    • /
    • pp.833-837
    • /
    • 2004
  • DeniLite$^{TM}$ laccase immobilized platinum electrode was used for amperometric detection of hydroquinone (HQ) and homogentisic acid (HGA) by means of substrate recycling. In case of HQ, the obtained sensitivity is 280 nA/ ${\mu}$M with linear range of 0.2-35 ${\mu}$M ($r^2$ = 0.998) and detection limit (S/N = 3) of 50 nM. This high sensitivity can be attributed to chemical amplification due to the cycling of the substrate caused by enzymatic oxidation and following electrochemical regeneration. In case of HGA, the obtained sensitivity is 53 nA/ ${\mu}$M with linear range of 1-50 $[\mu}M\;(r^2$ = 0.999) and detection limit of 0.3 ${\mu}$M. The response times ($t_{90%}$) are about 2 seconds for the two substrates and the long-term stability is 60 days for HQ and around 40-50 days for HGA with retaining 80% of initial activities. The very fast response and the durable long-term stability are the principal advantages of this sensor. pH studies show that optimal pH of the sensor for HQ is 6.0 and that for HGA is 4.5-5.0. This shift of optimal pH towards acidic range for HGA can be attributed to the balance between enzyme activity and accessibility of the substrate to the active site of the enzyme.

Viologen 유도체를 전하전달체로 이용한 Glucose 센서의 $H_2O_2$ 검출 특성 ($H_2O_2$ Detection Property of Glucose Sensor using Self Assembled Viologen Modified Electrode as Mediator)

  • 이동윤;최원석;박상현;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.86-87
    • /
    • 2007
  • An amperometric glucose biosensor has been developed using viologen derivatives as electron mediator of glucose oxidase (GOD) at Au electrode. Highly stable self assembled monolayer (SAM) of thiol-based viologen is immobilized onto the Au electrode followed byGOD is immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of -300 mV. Upon immobilization of glucose oxidase onto the viologen modified-electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance such as, pH, potential were optimized and assessed. This biosensor offered an excellent electrochemical response for glucose concentration below ${\mu}mol$ level with high sensitivity and selectivity and short response time. The levels of the RSD's (< 5 %) for the entire analyses reflected the highly reproducible sensor performance. Using the optimized a linear relationship between current and glucose concentration was obtained up to $4.5{\times}10^{-4}$ M. In addition, this biosensor showed well reproducibility and stability.

  • PDF

안전난간유형에 따른 작업자 안전의 상관관계에 대한 실험적 연구 (An Experimental Study on the Correlationship Between Highrised Safetyguard and Workers' Safety)

  • 손기상
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.80-84
    • /
    • 2001
  • Work stress and health are very important factors related to workers' condition and work safety, Author has conducted a couple of tests to check up three people's pulses before they work during their work for three types of safety guard in construction site. Work type, age, weight, sex experience year, ambient temperature n recorded as variables in this study. These are checked and asked by the author directly, before their pulse check Also, workers' Pulses were measured at height H-0 and H-9.0m to understand psychological the degree of psychological nervousness degree. POLAR protrainer NVTM HRM system(wrist recorder and sensor) was used for the site test. There are three(3) different types of construction safety guard which have been used for, this study. They are usually or frequently used and found in the site. Four different ranges of age groups(20's, 30's 40's, 50's) carpenters are assisted to the test sites with wearing pulse recorder and sensor respectively. All three types of safety guards have the same height 90㎝ even though they are different types. On top of five(5) stories tublar framed scaffolding is fabricated, similar to the one in site, where those safety guards are installed. The older(=more experienced) the workers are the more stable they are. it is shown. Also, It is verified the visually uncomfortable rail type can cause workers to psychologically be unstable.

  • PDF

광학적 가스센서 특성 향상을 위한 광 공동 구조의 고찰 (Speculation of Optical Cavity for Improving Optical Gas Sensor's Characteristics)

  • 이승환;박종선
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.63-68
    • /
    • 2008
  • 본 논문은 적외선 센서의 광 강도 및 효율을 증가시키기 위해 새로운 오목한 반사 벽면(curved mirror surface)과 기존의 수직 반사 벽면(vertical mirror surface)구조와의 모의해석 및 실험 결과에 대해 기술하였다. 모의해석 결과 수직 반사 벽면을 사용했을 때 적외선 센서 필터 표면에 도달하는 광의 분포는 타원 형상으로 적외선 센서 표면에 도달함을 볼 수 있고, 오목한 반사 벽면을 사용하는 경우에는 광이 원형상으로 집광되는 것을 볼 수 있었다. 따라서 초기 평행광의 면적보다 작은 면적으로 집광됨으로 인해 단위면적당 광 강도는 향상되고, 이에 따라 광학적 센서의 출력전압은 향상될 것이라 예측되었다. 이 모의해석을 근간으로 하여 $25^{\circ}C$, 45%R.H.에서 이산화탄소를 0 ppm에서 2500 ppm까지 250 ppm 간격으로 주입시켰을 때, 오목한 반사 벽면의 광 공동이 수직 반사 벽면의 광 공동보다 출력전압이 약 200 mV 증가하였다.

  • PDF

산화주석을 기반으로 한 DMMP 후막가스센서 제작 (fabrication of DMMP Thick Film Gas Sensor Based on SnO2)

  • 최낙진;반태현;곽준혁;백원우;김재창;허증수;이덕동
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1217-1223
    • /
    • 2003
  • Nerve gas sensor based on tin oxide was fabricated and its characteristics were examined. Target gas is dimethyl methyl phosphonate(C$_3$ $H_{9}$ $O_3$P, DMMP) that is simulant gas of nerve gas. Sensing materials were Sn $O_2$ added a-Al$_2$ $O_3$ with 0∼20wt.% and were physically mixed each material. They were deposited by screen printing method on alumina substrate. The sensor device was consisted of sensing electrode with interdigit(IDT) type in front and a heater in back side. Total size of device was 7${\times}$10${\times}$0.6㎣. Crystallite size & phase identification and morphology of fabricated Sn $O_2$ powders were analyzed by X-ray diffraction and by a scanning electron microscope, respectively. Fabricated sensor was measured as flow type and resistance change of sensing material was monitored as real time using LabVIEW program. The best sensitivity was 75% at adding 4wt.% $\alpha$-Al$_2$ $O_3$, operating temperature 30$0^{\circ}C$ to DMMP 0.5ppm. Response and recovery time were about 1 and 3min., respectively. Repetition measurement was very good with $\pm$3% in full scale.TEX>$\pm$3% in full scale.

Zinc phthalocyanine(ZnPc)화합물의 이용한 유기용제 센서 (Solvent Sensing Properties of Thin Films Based on Zinc phthalocyanine (ZnPc) Compounds)

  • 김동현;강영구;김정훈;노상철;김현주
    • 한국가스학회지
    • /
    • 제9권4호
    • /
    • pp.26-29
    • /
    • 2005
  • 본 연구에서는 Metallophthalocyanine Macrocyclic Compounds인 Zinc phthalocyanine(ZnPc)를 이용하여 박막 films를 만들어 solvent sensor의 특성에 대한 연구을 수행하였다. 측정에 사용한 유기용제의 종류는 Acetic acid, Ethyl alcohol, Methyl alcohol, Ammonia 및 1,1,1-trichloroethane이였으며, solvent sensing 특성으로는 전기저항 변화를 측정 분석하였다. 또한 Zinc phthalocyanines과 $N,N'-diphenyl-N,N'-bis(1-naphthyl)-1,\;1-biphenyl-4,4'-diamine\;and/or\; Poly[2-methoxy-5-(2'-ethylhexyloxy)-1,4-phenylene-vinylene]$를 blend하여 spin-coating, evaporation박막을 만들어 유기용제 농도에 따라서 전기 저항 변화를 측정 분석하였다.

  • PDF

유연성 광전도 CdS 박막의 증착조건에 따른 전기적 특성 및 신뢰성 평가 연구 (Electrical Properties and Reliability of the Photo-conductive CdS Thin Films for Flexible Opto-electronic Device Applications)

  • 허성기;조현진;박경우;안준구;윤순길
    • 한국전기전자재료학회논문지
    • /
    • 제22권12호
    • /
    • pp.1023-1027
    • /
    • 2009
  • Cadmium sulfide (CdS) thin film for flexible optical device applications were prepared at $H_2/(Ar+H_2)$ flow ratios on polyethersulfon (PES) flexible polymer substrates at room temperature by radio frequency magnetron sputtering technique. The CdS thin films deposited at room temperature showed a (002) preferred orientation and the smooth surface morphologies. Films deposited at a hydrogen flow ratio of 25% exhibited a photo- and dark-sheet resistance of about 50 and $2.7\;{\times}\;10^5\;{\Omega}/square$, respectively. From the result of the bending test, CdS films exhibit a strong adhesion with the PES polymer substrates and the $Al_2O_3$ passivation layer deposited on the CdS films only shows an increase of the resistance of 8.4% after exposure for 120 h in air atmosphere.