• Title/Summary/Keyword: $H_2S$ removal

Search Result 779, Processing Time 0.027 seconds

Removal of Malordorous Sulfur Compounds by Thiobacilius neapolitanus R-10 (Thiobacillus neapolitanus R-10에 의한 유황계 악취물질의 제거)

  • 원용돈;박상보
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.215-222
    • /
    • 1995
  • Thiokncillus neapolitanus R-10 isolated from sludge of night soil, showed an oxidizing activity on several malodorous sulfur compounds. The microbe successfully utilized hydrogen sulfide(H2S), methy mercaptan(MM), dimethyl sulfide(DMS) and dimethyldisulfide(DMDS) during the batch culture reaction, of which H2S was rather rapidly oxidized. To examine the ability for removal of malodorous sulfur compounds, various concentrations of sulfide substrates were supplemented separately to basal medium and their responses were investigated. As the concentration of sulfide was increased, growth was accelerated within three days of cultivation. 2.5mM was the most favorable substrate concentration of sulfide added for all cases tested. However, when the concentration of sulfur compounds were raised over 4M, they behaved as a growth inhibitor.

  • PDF

HEAT REMOVAL TEST USING A HALF SCALE STORAGE CASK

  • Bang, K.S.;Lee, J.C.;Seo, K.S.;Cho, C.H.;Lee, S.J.;Kim, J.M.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.2
    • /
    • pp.143-148
    • /
    • 2007
  • Spent nuclear fuel generated at nuclear power plants must be safely stored during interim storage periods. A dry storage cask to safely store the spent nuclear fuel should be able to adequately emit the decay heat from the spent nuclear fuel. Therefore, heat removal tests using a half scale dry storage cask have been performed to estimate the heat transfer characteristics of a dry storage cask under normal, off-normal, and accident conditions. In the normal condition, the heat transfer rate to an ambient atmosphere by convective air through a passive heat removal system reached 83%. Accordingly, the passive heat removal system is designed well and works adequately. In the off-normal condition, the influence of a half blockage in the inlet on the temperature appears minimal. In the accident condition, the temperature rose for 12 hours after the accident, but the temperature rise steadied after 36 hours.

Heterotrophic nitrification-aerobic denitrification potential of cyanide and thiocyanate degrading microbial communities under cyanogenic conditions

  • Mekuto, Lukhanyo;Kim, Young Mo;Ntwampe, Seteno K.O.;Mewa-Ngongang, Maxwell;Mudumbi, John Baptist N.;Dlangamandla, Nkosikho;Itoba-Tombo, Elie Fereche;Akinpelu, E.A.
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.254-262
    • /
    • 2019
  • The impact of free cyanide ($CN^-$) and thiocyanate ($SCN^-$) on the $CN^-$ (CDO) and $SCN^-$ degraders (TDO) to nitrify and denitrify aerobically was evaluated under alkaline conditions. The CDO's were able to nitrify under cyanogenic conditions, achieving $NH_4{^+}-N$ removal rates above 1.66 mg $NH_4{^+}-N.L^{-1}.h^{-1}$, except when $CN^-$ and $SCN^-$ loading was 15 mg $CN^-/L$ and 50 mg $SCN^-.L^{-1}$, respectively, which slightly inhibited nitrification. The TDO's were able to achieve a nitrification rate of 1.59 mg $NH_4{^+}-N.L^{-1}.h^{-1}$ in the absence of both $CN^-$ and $SCN^-$, while the presence of $CN^-$ and $SCN^-$ was inhibitory, with a nitrification rates of 1.14 mg $NH_4{^+}-N.L^{-1}.h^{-1}$. The CDO's and TDO's were able to denitrify aerobically, with the CDO's obtaining $NO_3{^-}-N$ removal rates above 0.67 mg $NO_3{^-}-N.L^{-1}.h^{-1}$, irrespective of the tested $CN^-$ and $SCN^-$ concentration range. Denitrification by the TDO's was inhibited by $CN^-$, achieving a removal rate of 0.46 mg $NO_3{^-}-N.L^{-1}.h^{-1}$ and 0.22 mg $NO_3{^-}-N.L^{-1}.h^{-1}$ when $CN^-$ concentration was 10 and 15 mg $CN^-.L^{-1}$, respectively. However, when the CDO's and TDO's were co-cultured, the nitrification and aerobic denitrification removal rates were 1.78 mg $NH_4{^+}-N.L^{-1}.h^{-1}$ and 0.63 mg $NO_3{^-}-N.L^{-1}.h^{-1}$ irrespective of $CN^-$ and $SCN^-$ concentrations.

Entrapment of Milk Nutrients during Cholesterol Removal from Milk by Crosslinked β-Cyclodextrin

  • Ha, H.J.;Jeon, S.S.;Chang, Y.H.;Kwak, H.S.
    • Food Science of Animal Resources
    • /
    • v.29 no.5
    • /
    • pp.566-572
    • /
    • 2009
  • This study was designed to elucidate the quantities of milk nutrients entrapped during cholesterol removal from milk by crosslinked $\beta$-cyclodextrin ($\beta$-CD, 0.4~1.2%, w/v) and to evaluate the amounts of the residual $\beta$-CD in cholesterol-reduced milk treated by crosslinked $\beta$-CD. The content of lactose in the control milk (without treatment by crosslinked $\beta$-CD) was 4.86%, and the amounts of lactose entrapped by crosslinked $\beta$-CD ranged from 0.00 to 0.03%. The total amounts of the entrapped short-chain free fatty acid (FFA) and free amino acid (FAA) ranged from 0.03 to 0.09 ppm and from 0.28 to $0.71{\mu}mol/mL$, respectively. The amounts of the entrapped water-soluble vitamins (L-ascorbic acid, niacin, thiamine and riboflavin) ranged from 0.02 to 0.05 ppm, 0.01 to 0.06 ppm, 0.00 to 0.06 ppm and 0.01 to 0.06 ppm, respectively. The entrapped amounts of lactose, short-chain FFAs, FAAs and water-soluble vitamins were not remarkably affected by the concentrations of crosslinked $\beta$-CD (0.4~1.2%, w/v). Only very small amounts of residual $\beta$-CD in the cholesterol-removed milk were measured (1.22~3.00 ppm). Based on the data obtained from the present study, it was concluded that the amounts of entrapped nutrients were negligible during cholesterol removal from milk by crosslinked $\beta$-CD, and only trace amounts of residual $\beta$-CD were present in cholesterol-removed milk.

Collection characteristics of wet-type rotating porous disk system for air pollutants removal of marine diesel engines (박용디젤기관의 대기오염 저감을 위한 습식 회전형 다공성 디스크 시스템의 집진특성)

  • Yoa, Seok-Jun;Jang, Chang-Ik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.318-325
    • /
    • 2014
  • The main object of this study is to investigate the collection characteristics of wet-type rotating porous disk system experimentally. The experiment is carried out to analyze the pressure drop and collection efficiency for the present system with the experimental parameters such as system inlet velocity, stage number, tube diameter, inlet concentration, etc. In results, for the present system, at 5 stage and ${\upsilon}_{in}=1.8m/s$, the pressure drop becomes significantly lower as $64mmH_2O$ in comparison with that of the conventional wet type scrubber (Venturi scrubber, over $250mmH_2O$). The collection efficiencies increase with higher inlet velocity showing 92, 95.7, 98.4%, while $SO_2$ removal efficiencies decrease with increment of inlet velocity as 80, 65, 50% at ${\upsilon}_{in}=1.08$, 1.44, 1.8 m/s and tube diameter $D_t=10mm$, respectively. The present system is to be considered as an effective compact system for a simultaneous removal of particle/gas phase pollutants from marine diesel engines.

Removal Efficiency of Some Odorants against Water as Sorptive Media: A Case Study on Trimethylamine and Reduced Sulfur Compounds (물을 흡수매체로 이용한 트리메틸아민과 환원황화합물의 제거효율 비교 연구)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Ok, Joon-Seok;Kim, Yong-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.512-522
    • /
    • 2009
  • In this study, the removal efficiency of trimethylamine (TMA) and four reduced sulfur compounds (RSC) of $H_2S$, $CH_3SH$, DMS, and DMDS was investigated using deionized water as absorbent. To this end, two types of experiments were conducted which include: (1) by passing both RSC and TMA standard gases through water contained in an impinger system and (2) by passing TMA gases through a water spray system. In the former method, TMA standard gases were effectively removed (below detection limit) in all experiments. Likewise, minor fractions of some RSC ($CH_3SH$, DMS, and DMDS) were removed by water in line with theoretical expectations. In addition, the first type of our experiment was extended further to test some commercially available odor treatment products. The results of this test showed that removal efficiencies of RSC $(8.2\pm13.7\sim43.7\pm2.48%)$ were different significantly among 4 kinds of absorbent, while the removal of TMA was consistently good as water. In the second phase of experiment, removal efficiency of TMA was tested by passing its standard gas through a water spray system. The overall results of our study showed that the actual removal efficiency of odorants by water (as sorptive media) approached the values that can be predicted theoretically (by Henry's law).

Microbial Diversity of the Trichloroethylene Contaminated Groundwater Treatment System and Characterization of Pseudomonas sp. DHC8 (Trichloroethylene으로 오염된 지하수 제거공정의 미생물 다양성 및 분리균주 Pseudomonas sp. DHC8의 특성)

  • Nam, Ji-Hyun;Shin, Ji-Hye;Kwon, Kiwook;Bae, Wookeun;Lee, Dong-Hun
    • Korean Journal of Microbiology
    • /
    • v.49 no.4
    • /
    • pp.336-342
    • /
    • 2013
  • Trichloroethylene (TCE) is a widely used substance in commercial and industrial applications, yet it must be removed from the contaminated soil and groundwater environment due to its toxic and carcinogenic nature. We investigated bacterial community structure, dominant bacterial strain, and removal efficiency in a TCE contaminated groundwater treatment system using immobilized carrier. The microbial diversity was determined by the nucleotide sequences of 16S rRNA gene library. The major bacterial population of the contaminated groundwater treatment system was belonging to BTEX degradation bacteria. The bacterial community consisted mainly of one genus of Pseudomonas (Pseudomonas putida group). The domination of Pseudomonas putida group may be caused by high concentration of toluene and TCE. Furthermore, we isolated a toluene and TCE degrading bacterium, named Pseudomonas sp. DHC8, from the immobilized carrier in bioreactor which was designed to remove TCE from the contaminated ground water. Based on the results of morphological and physiological characteristics, and 16S rRNA gene sequence analysis, strain DHC8 was identified as a member of Pseudomonas putida group. When TCE (0.83 mg/L) and toluene (60.61 mg/L) were degraded by this strain, removal efficiencies were 72.3% and 100% for 12.5 h, respectively. Toluene removal rate was 2.89 ${\mu}mol/g$-DCW/h and TCE removal rate was 0.02 ${\mu}mol/g$-DCW/h. These findings will be helpful for maintaining maximum TCE removal efficiency of a reactor for bioremediation of TCE.

Performance evaluation of membrane bioreactor (MBR) coupled with activated carbon on tannery wastewater treatment

  • Alighardashi, Abolghasem;Pakan, Mahyar;Jamshidi, Shervin;Shariati, Farshid Pajoum
    • Membrane and Water Treatment
    • /
    • v.8 no.6
    • /
    • pp.517-528
    • /
    • 2017
  • This study evaluates the performance of membrane bioreactor (MBR) coupled with a modified walnut shell granular activated carbon (WSGAC) for tannery wastewater treatment. For this purpose, a pilot with overall volume of 80L and 12 hours hydraulic retention time (HRT) is operated in three scenarios. Here, the chemical oxidation demand (COD) of wastewater is reduced more than 98% in both C:N ratios of 13 (S1) and 6.5 (S2). This performance also remains intact when alkalinity depletes and pH reduces below 6 (S3). The ammonium removal ranges between 99% (S2) and 70% (S3). The reliability of system in different operating conditions is due to high solids retention time and larger flocs formation in MBR. The average breakthrough periods of WSGAC are determined between 15 minutes (S2) and 25 minutes (S1). In this period, the overall nitrate removal of MBR-WSGAC exceeds 95%. It is also realized that adding no chemicals for alkalinity stabilization and consequently pH reduction of MBR effluent (S3) can slightly lengthen the breakthrough from 15 to 20 minutes. Consequently, MBR can successfully remove the organic content of tannery wastewater even in adverse operational conditions and provide proper influent for WSGAC.

A Study on Odor Removal of Landfill Site Leachate by Pyroligenous Liquid (목초액을 이용한 쓰레기 매립지 침출수의 악취 제거에 관한 연구)

  • 허광선;정의덕;백우현
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.607-610
    • /
    • 1999
  • The odor removal of landfill site leachate was carried out using pyroligenous liquid. The constituent elements of pyroligenous liquid and leachate were also analysed, employing Atomic Absorption Spectroscopy(AAS). Before order removal, the heavy metal ions such as Pb, Zn, Cu, Mn, Fe and Ni, in pyroligenous liquid were detected with ultra trace level. However, in this liquid, other metal ions such as As, Hg and Cd were not observed. The optimum condition for removing odor fromthe leachate was observed in 15 times dilution of pyroligenous liquid. Also, the degree of outlet odor was 1. Furthermore, the concentration of odor constituent compounds, e.g. $H_2S, NH_3, NH_2$ and $CO_2$ in the leachate was remarkably reduced. Finally, water quality of the leachate was improved.

  • PDF

Removal of Algogenic Organic Matter in Drinking Water Treatment Process (정수처리공정에서 조류유래 유기물질의 제거)

  • Park, Se-Jin;Cha, Il-Kwon;Yoon, Tai-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.377-384
    • /
    • 2005
  • Algae causes not only the eutrophication of lake, but also the deterioration of drinking water process. Especially, algogenic organic matters(AOM) are assumed as disinfection by-products(DBPs) precursors like humic and fulvic acids. In this study, it was investigated the characteristics changes of algogenic organic matter(AOM) by prechlorination and coagulation treatment. Evaluation of enhanced coagulation and applicability of UV oxidation process were also evaluated as the drinking water treatment system for the eutrophicated water source. prechlorination was effective process for algae removal but caused releasing of dissolved organic matter(DOC) into water due to the destruction of algae's cell. In coagulation treatment with Fe(III) coagulant, reaction pH is an important factor for the removal of AOM and triholomathanes(THMs). At pH 5, removal efficiency of DOC and THMs were dramatically improved by 50% and 28%, respectively, in comparison with the conventional coagulation treatment at about pH 7. Photo-Fenton($UV/H_2O_2/Fe^{3+}$) process among the UV oxidations is the most effective system to remove AOM, but its removal efficiency was lower than that of enhanced coagulation treatment at pH 5.