• 제목/요약/키워드: $H_{\infty}$ loop shaping

검색결과 37건 처리시간 0.025초

이동통신 단말기 카메라의 손떨림 보정 장치의 H 제어 (H Control on the Optical Image Stabilizer Mechanism in Mobile Phone Cameras)

  • 이치범
    • 한국생산제조학회지
    • /
    • 제23권3호
    • /
    • pp.266-272
    • /
    • 2014
  • This study proposes a closed-loop shaping control method with $H_{\infty}$ optimization for optical image stabilization (OIS) in mobile phone cameras. The image stabilizer is composed of a horizontal stage constrained by ball bearings and actuated by the magnetic force from voice coil motors. The displacement of the stage is measured by Hall effect sensors. From the OIS frequency response experiment, the transfer function models of the stage and Hall effect sensor were identified. The weight functions were determined considering the tracking performance, noise attenuation, and stability with considerable margins. The $H_{\infty}$ optimal controller was executed using closed-loop shaping and limiting the controller order, which should be less than 6 for real-time implementation. The control algorithm was verified experimentally and proved to operate as designed.

$\textrm{H}_\infty$ 기법에 의한 발사체의 견실한 제어기 설계 (Robust Controller Design by $\textrm{H}_\infty$ Method for a Launch Vehicle)

  • 이군석;권오규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.463-468
    • /
    • 1992
  • In this paper, discrete-time H$_{\infty}$ controller design in .delta.- domaion using Normalized Coprime Factor plant description is proposed and the loop-shaping method developed by Mcfalane[2], which is known to be very simple and systematic method, is adopted here in H$_{\infty}$ controller design. In particular, we show that .delta.- H$_{\infty}$ controller proposed here is a unified form for the continuous and discrete-time cases.es.

  • PDF

고속 위치제어계의 강인 $H_\infty$ 제어 (Robust $H_\infty$ Control of High-Speed Positioning Systems)

  • 최진택;김종식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.342-347
    • /
    • 1995
  • Loop shaping $H_{\infty}$control with normalized coprime factorization was applied to a servo-motor driven high-speed powitioning system. The high-gain controller was designed to attenuate the postion errors caused byfriction effects and extermal disturbances. The non-existence of limit cycle was analyzed, though there is actuator saturation. The designed $H_{\infty}$control system was experimently tested in a rotary index table. Results showed its effectiveness to improve postion accuracy with out any compensation scheme for friction, and robustness to model perturbation and external disturbances.ces.

  • PDF

선박용 대형 디젤 기관의 강인 속도 제어기 설계 (Design of Robust Speed Controllers for Marine Diesel Engine)

  • 황순규;이영찬;김창화;정병건
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.820-828
    • /
    • 2011
  • 에너지 절약은 해상운송분야에서 이익을 내기 위한 가장 중요한 요인 중 하나이다. 연료 소비율을 낮추기 위해서는 가능한 한 선박의 추진효율을 높여야만 한다. 추진효율은 추진기관과 낮은 회전속도에서 더 좋은 효율을 갖는 프로펠러의 조합에 의존한다. 기관은 저속이 될수록 연료분사과정에서의 지연시간으로 인해 회전 토크 변동이 심해진다. 본 연구에서는 강인 제어이론을 적용하여 강인 안정성과 강인 성능을 고려한 기관 속도제어기들, 즉 준최적 $H_{\infty}$제어기, $H_{\infty}$루프-성형 제어기 및 ${\mu}$-제어기를 설계한다. 컴퓨터 시뮬레이션 결과로부터 이들 3가지 제어기의 타당성을 검토한다.

AN LMI APPROACH TO AUTOMATIC LOOP-SHAPING OF QFT CONTROLLERS

  • Bokharaie, Vaheed S.;Khaki-Sedigh, Ali
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.433-437
    • /
    • 2003
  • Quantitative Feedback Theory (QFT) is one of effective methods of robust controller design. In QFT design we can considers the phase information of the perturbed plant so it is less conservative than $H_{\infty}$ and ${\mu}$-synthesis methods and as be shown, it is more transparent than the sensitivity reduction methods mentioned . In this paper we want to overcome the major drawback of QFT method which is lack of an automatic method for loop-shaping step of the method so we focus on the following problem: Given a nominal plant and QFT bounds, synthesize a controller that achieves closed-loop stability and satisfies the QFT boundaries. The usual approach to this problem involves loop-shaping in the frequency domain by manipulating the poles and zeros of the nominal loop transfer function. This process now aided by recently developed computer aided design tools proceeds by trial and error and its success often depends heavily on the experience of the loop-shaper. Thus for the novice and First time QFT user, there is a genuine need for an automatic loop-shaping tool to generate a first-cut solution. Clearly such an automatic process must involve some sort of optimization, and while recent results on convex optimization have found fruitful applications in other areas of control theory we have tried to use LMI theory for automating the loop-shaping step of QFT design.

  • PDF

유전자 알고리즘을 이용한 다중 제한 조건을 만족하는 강인 트랙 추종 제어 (A Robust Track-following Control with Multiple Constraints Using Genetic Algorithm)

  • 이문노;이홍규;진경복
    • 한국소음진동공학회논문집
    • /
    • 제22권3호
    • /
    • pp.275-283
    • /
    • 2012
  • This paper presents a design method of a robust tracking controller satisfying multiple constraints using genetic algorithm. A robust $H_{\infty}$ constraint with loop shaping is used to address disturbance attenuation with error limits and a loop gain constraint is considered so as not to enlarge the tracking loop gain and bandwidth unnecessarily. The robust $H_{\infty}$ constraint is expressed by a matrix inequality and the loop gain constraint is considered as an objective function so that genetic algorithm can be applied. Finally, a robust tracking controller can be obtained by integrating genetic algorithm with LMI approach. The proposed tracking controller design method is applied to the track-following system of an optical DVD recording drive and is evaluated through the experimental results.

발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구 (A Study on the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant)

  • 권오규;이영삼
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1037-1040
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bumpless transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

SPM-based Data Storage 시스템을 위한 강인 제어 시스템 설계 방식을 이용한 외란 관측 제어기 설계 (Design of Disturbance Observer Using Robust Control Method for SPM-based Data Storage Systems)

  • 문준;이충우;정정주
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.160-167
    • /
    • 2009
  • In this paper, we apply the robust disturbance observer (DOB) to a SPM-based data storage (SDS) system. In the SDS system, coupling dynamics and parameter uncertainties are obstacles to the precision tracking control. Although the DOB is known to be an effective method to reject disturbances, there has been no systematic design approach to how to design DOB parameters. In this paper, the robust DOB is formulated based on the robust stabilization of normalized coprime factor plant description and the $H{\infty}$ loop shaping method. From the simulation and experimental results. the improved robustness and performance are obtained by the proposed robust DOB.

발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구 (A Study on the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant)

  • 권오규;이영삼
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.689-692
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bump less transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구 (A Study en the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant)

  • 권오규;이영삼
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.369-372
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bumpless transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF