• Title/Summary/Keyword: $F_0-value$

Search Result 1,904, Processing Time 0.032 seconds

Disease Reaction of a Japonica Rice, Keumo3, and Detection of a Linked DNA Marker to Leaf Blast Resistance ("금오3호"의 벼 잎도열병 저항성 특성 및 저항성 연관 마커 탐색)

  • Lee, Jong-Hee;Kwak, Do-Yeon;Pakr, Dong-Soo;Roh, Jae-Hwan;Kang, Jong-Rae;Kim, Choon-Song;Jeon, Myeong-Gi;Yeo, Un-Sang;Yi, Gihwan;Shin, Mun-Sik;Oh, Byeong-Geun;Hwang, Hung-Goo
    • Korean Journal of Breeding Science
    • /
    • v.40 no.4
    • /
    • pp.408-413
    • /
    • 2008
  • Rice blast resistance is considered one of the most important traits in rice breeding and the disease, caused by Magnaporthe grisea Barr, has brought significant crop losses annually. Moreover, breakdown of resistance normally occurs in two to five years after cultivar release, thus a more durable resistance is needed for better control of this disease. We developed a new variety, Keumo3, which showed strong resistance to leaf blast. It was tested in 2003 to 2007 at fourteen blast nursery sites covering entire rice-growing regions of South Korea. It showed resistance reactions in 12 regions and moderate in 2 regions without showing susceptible reactions. Durability test by sequential planting method indicated that this variety had better resistance. Results showed that Keumo3 was incompatible against 19 blast isolates with the exception of KI101 by artificial inoculation. To understand the genetic control of blast resistance in rice cultivar Keumo3 and facilitate its utilization, recombinant inbred lines (RIL) consisting of 290 F5 lines derived from Akidagomachi/Keumo3 were analyzed and genotyped with Pizt InDel marker zt56591. The recombination value between the marker allele of zt56591 and bioassay data of blast nursery test was 1.1%. These results indicated that MAS can be applied in selecting breeding populations for blast resistance using zt56591 as DNA marker.

The Impact of Justice of Layoff on Management Trust, Job Satisfaction and Organizational Commitment in the Hotel Corporations (호텔기업에 있어 구조조정상의 공정성 지각이 경영진의 신뢰, 직무만족 및 조직몰입에 미치는 영향)

  • Kim, Young-Soon;Ahn, Dae-Hee
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.1
    • /
    • pp.115-139
    • /
    • 2008
  • Since financial crisis of IMF resulted in intensive competitiveness and adverse management environment, many hotel industries have responded it with restructuring. Since this restructuring is accompanied by reduction of employees, hence comes the recognition of justice in the procedure of restructuring. When the surviving employees in the restructuring process recognize unfairness in the procedure and practical operations, organization effectiveness can not be maintained due to losing trust of their employers. In this paper I will examine the relationship between validity of restructuring and compensatory programs for layoffs and surviving employees' trust of the employers. Also I will find out the relationship between remaining employees' trust of the employers and their job satisfaction and organization commitment. Through this relationship, we can prepare an alternative to reduce negative effect of restructuring. The hypotheses of this study are proposed as follows: H1: The higher surviving employees' recognition of procedural justice in restructuring process is, the higher their trust with a manager of the company is. H2: The higher surviving employees' recognition of distributive justice in restructuring process is, the higher their trust with a manager of the company is. H3: The higher surviving employees' recognition of procedural justice in restructuring process is, the higher their job satisfaction is. H4: The higher surviving employees' recognition of distributive justice in restructuring process is, the higher their job satisfaction is. H5: The higher surviving employees' recognition of procedural justice in restructuring process is, the higher their organization commitment is. H6: The higher surviving employees' recognition of distributive justice in restructuring process is, the higher their organization commitment is. H7: The higher surviving employees' trust with a manager of the company in restructuring process is, the higher their job satisfaction is. H8: The higher surviving employees' trust with a manager of the company in restructuring process is, the higher their organization commitment is. For the purposes of this study, employees working in luxury hotels located in Seoul were targeted. Self-administered questionnaires were distributed to those who consented with the investigation after explaining the purpose of the survey. A total of 500 questionnaires were distributed and 450 questionnaire were returned to the researcher for analysis. 430 of the returned questionnaires were used for analysis. As for the education for this survey, 250 junior college graduates or under (58.1%), 143 college graduates (33.3%) and 37 graduate school graduates (8.6%). As for the marital status, 315 persons (73.3%) are single and 115 are married (26.7%). As for the monthly income, 49 people (11.48%) are less than 2 million won, 148 (34.4%) are between 2 million and less than 2.5 million won, 153 (35.6%) are between 2.5 million to less than 3 million won, 80 (18.6%) are more than 3 million won. As for the workplace, 293 people (68.1%) work for the F&B department, 73 (17.0%) for rooms department, 41 (9.5%) for operation/ marketing department, 23 (5.3%) for account/ general affair department. As for the period of employment, 85 people (19.8%) are less than 5 years, 150 (34.9%) are between 6 to 9 years, 143 (33.3%) are between 10 to 14 years. and 52 (3.%) are more than 15 years. An exploratory factor analysis was used to survey validity and reliability of calculating tool on perceived values. This study used correlation between individual items and whole items and Cronbach's alpha value of multiple-item scale which is usually used to assess scale and reliability. Reliability of conceptual sub-dimension was assessed by basing on repeated procedure of correlation between individual items and whole items and factor loading. 1. Verification of correlation between validity of restructuring and trust This research showed that procedural and distributive justice of restructuring affects trust positively. The path coefficient between procedural justice of restructuring and trust is 0.719(t=10.135, p=0.000), and thereby the higher procedural justice results in higher trust. The path coefficient between distributive justice of restructuring and trust is 0.160(t=3.291, p=0.001), and thereby the higher distributive justice results in higher trust. Hence H1 and H2 are accepted. 2. Verification of correlation between validity of restructuring and job satisfaction The path coefficient between procedural justice of restructuring and job satisfaction is 0.179(t=2.202, p=0.028), and thereby the higher procedural justice results in higher job satisfaction. The path coefficient between distributive justice of restructuring and job satisfaction is 0.074(t=1.620, p=0.105), and thereby distributive justice of restructuring has no relationship with job satisfaction. Hence H3 is accepted, but H4 is removed. 3. Verification of correlation between validity of restructuring and organization commitment The path coefficient between procedural justice of restructuring and organization commitment is 0.188(t=2.466, p=0.014), and thereby the higher procedural justice results in higher organization commitment. The path coefficient between distributive justice of restructuring and organization commitment is 0.118(t=2.720, p=0.007), and thereby the higher distributive justice results in higher organization commitment. Hence H5 and H6 are accepted. 4. Verification of correlation between trust and job satisfaction The path coefficient between trust and job satisfaction is 0.610(t=6.736, p=0.000), and thereby the correlation has a meaningful result. Since the higher trust of the employer results in higher job satisfaction, H7 is accepted. 5. Verification of correlation between trust and organization commitment The path coefficient between procedural justice of restructuring and job satisfaction is 0.446(t=5.547 p=0.000), and thereby the higher trust of the employer results in higher organization commitment. Hence H8 is accepted. This research aimed to help the employers of hotel industries by analyzing the effects of validity of restructuring on employees' trust, job satisfaction and organization commitment. The research found that employer's validity of restructuring has significant affects on the degree of employee's trust with a manager, thereby reducing the negative effects of restructuring and enhancing organization commitment and job satisfaction. The principal purpose of this research is to confirm the correlation between employees' perceived validity of restructuring and their trust with a manager. Also whether this correlation results in competitive edge of the company is also investigated. It is also pointed out that employees had to participated the procedure of restructuring, sharing the philosophy and reason of restructuring. This participation and furthermore compensatory methods can reduce employees' anxiety of organization operations. Variable of trust appeared to have impact on intermediation effect between perceived variable of validity and job satisfaction, organization commitment, so that increase of trust with a manager plays an crucial role in increasing organization effectiveness. Since this research did not cover whole hotel industries which underwent restructuring, it showed a limit. Unlike previous studies which dealt with validity and trust of superior bosses, this research focussed on employers. Also the organization citizenship which is not considered in this study will be dealt with in the future study.

  • PDF

The Relationship between Trust, Trustworthiness, and Repeat Purchase Intentions: A Multidimensional Approach (신뢰대상의 다차원적 접근법에 의한 신뢰와 재구매 의도와의 관계)

  • Lee, Soo-Hyung;Park, Mi-Ryong
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.1
    • /
    • pp.1-31
    • /
    • 2008
  • Trust is central to human relationships, at all times and places. The importance of trust is fundamental in all areas of human life, not only in the area of business administration. 2,500 years ago in China, Confucius taught that the foundation of politics was the trust of the people, more important even than military strength or the supply of food. Shakespeare's play, "Much Ado about Nothing' is about trust and deception. These days, trust and transparency in a commercial organization's business culture form the basis of the 'social capital' by which that organization increases its productivity. A successful company raises productivity by the accumulation of social capital, derived from a trust relationship between business partners, and between the company and consumers. Trust is the crucial factor. At the national level, building trust determines a nation's competitiveness. For a company, long term trust relationships with customers are essential for its survival in a business environment of rapid change. Such relationships, based on trust, are important assets to ensure a company's competitive advantage, and need to be organic to that company's business culture. Because of this importance, trust relationships have been studied in diverse areas within business administration, and especially within marketing, where they form the basis of a successful relationship between producer and consumer. However, what has been lacking is a unified definition of trust. Research has been conducted on the basis of various definitions and models. The majority of researchers have not considered the multidimensional character of the concept of trust until now. Approaches based on a one dimensional model have undermined the value of research results. Furthermore, researchers have only considered trust and trustworthiness as a single component. The majority of research has explored the consequences of perceived trust for outcomes such as loyalty or cooperation, but has neglected the effects of trustworthiness upon the mechanisms of consumer trust. This study focuses on the dimension of trust from such a perspective. It seeks to verify the effect of trust on customer intentions by breaking it down into three separate components: 1) the salesperson, 2) the product/service, and 3) the company. The purposes of this paper are as follows: Firstly, we review the multidimensional nature of trust objects: the salesperson, the product/service, and the company. Secondly, we analyze the relationship between multidimensional trust and trustworthiness. Thirdly, we analyze the connection between trust and repeat purchase intentions for the maintenance of long term relationships. For these purposes the author has developed several hypotheses as follows: H1-1: The competence of a salesperson is positively associated with the trust given by the consumer to the salesperson. H1-2: The benevolence of a salesperson is positively associated with the trust given by the consumer to the salesperson. H2-1: The competence of product/service is positively associated with the trust given by the consumer to the product/service. H2-2: The benevolence of product/service is positively associated with the trust given by the consumer to the product/service. H3-1: The reputation of a company is positively associated with the trust given by the consumer to the company. H3-2: The physical environment of a company is positively associated with the trust given by the consumer to the company. H4-1: Trust in a salesperson is positively associated with repeat purchase intentions. H4-2: Trust in a product/service is positively associated with repeat purchase intentions. H4-3: Trust in a company is positively associated with repeat purchase intentions. The data was compiled from 366 questionnaires. 500 questionnaires were collected, but some of the data was considered unsuitable and inappropriate. The subjects of the survey were male and female customers purchasing products at department stores in Seoul, Daegu and Gyeongbuk. It was carried out between Oct. 25 and 29, 2007. The data was analyzed by frequency analysis using SPSS 12.0 and structural equation modeling using LISREL 8.7. The result of the overall model analysis is as follows: Chi-Square=445.497, d.f.=185, p-value=0.0, GFI=.901, RMSEA=.0617, NNFI=.986, NFI=.981, CFI=.989, AGFI=.864, RMR=.0872. The results of the overall model analysis were coherent. It was found that trust is a multi-dimensional construct, that each of the dimensions of trust are meaningful influences on customer's repurchase intention. Trust in a company may be the most relevant, while trust in a product/service and a salesperson may be less relevant to repurchase intentions. The effective factors in determining trust in a salesperson and a company's product/service were found to be competence and benevolence. Factors in determining trust in a company were its reputation and physical environment, and the relationship of each effective trust factor has been verified in this research. As a result, it was found that competence and benevolence have a meaningful influence on trust in a salesperson and in product/service. It was also found that a company's reputation influences the overall trust in the company significantly but a company's physical environment does not have much effect.

  • PDF

Effects of Ouabain and Vanadate on K-pNPPase Activity in Rabbit Renal Cortical Slices (가토 신피질 절편에서의 K-pNPPase활성에 대한 Ouabain 및 Vanadate의 영향)

  • Woo, Jae-Suk;Kim, Yong-Keun;Lee, Sang-Ho
    • The Korean Journal of Physiology
    • /
    • v.19 no.2
    • /
    • pp.203-213
    • /
    • 1985
  • This study was carried out to investigate whether the K-pNPPase activity in renal cortical slices can be used as an index for measuring the activity of $Na^+-K^+$ exchange pump. The K-pNPPase activity, Ouabain-sensitive oxygen consumption add intracellular electrolytes content in slices, and Na-K-ATPase activity in microsome were measured and the effects of ouabain and vanadate on these were observed. The results are as follows : 1) p-NPPase activity in slices increased linearly with incubation time during 60 minutes, and $K^+$-dependent, ouabain-sensitive fraction was about 55% of total p-NPPase activity. This value was almost the same through out the incubation time. 2) The concentrations of ouabain and vanadate for 50f inhibition of K-pNPPase activity were$7.0{\times}10^{-6}M$ and $1.3{\times}10^{-5}M$, respectively. 3) The ouabain-sensitive oxygen consumption in slices was reduced to 50% of control value by $6.3{\times}10^{-6}M$ ouabain or $2.5{\times}10^{-5}M$ vanadate. These concentrations were similar to those for 50% inhibition of K-pNPPase activity. 4) The trends of intracellular electrolytes change by ouabain and vanadate were similar to those of the change in K-pNPPase activity. 5) The Na-K-ATPase activity in microsome prepared from renal cortex was completely inhibited by $10^{-3}M$ ouabain or $10^{-3}M$ vanadate and the concentration for 50% inhibition was $1.2{\times}10^{-6}M$ in ouabain and $1.6{\times}10^{-6}M$ in vanadate, which were much lower than those for K-pNPPase activity or ouabain-sensitive oxygen consumption in slices. These results indicate that K-pNPPase activity measured in renal cortical slices is a better index for evaluating $Na^+-K^+$ exchange pump activity than Na-K-ATPase activity measured in microsome.

  • PDF

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Surgical Treatment of Anomalous Origin of Coronary Artery from the Pulmonary Artery: Postoperative Changes of Ventricular Dimensions and Mitral Regurgitation (관상동맥-폐동맥 이상기시증(Anomalous Origin of Coronary Artery from Pulmonary Artery)의 수술적 치료: 중기 성적과 좌심실 및 승모판 기능의 변화 양상에 대한 연구)

  • Kang, Chang-Hyun;Kim, Woong-Han;Seo, Hong-Joo;Kim, Jae-Hyun;Lee, Cheul;Chang, Yoon-Hee;Hwang, Seong-Wook;Back, Man-Jong;Oh, Sam-Se;Na, Chan-Young;Han, Jae-Jin;Lee, Young-Tak;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.19-26
    • /
    • 2004
  • Background: The aims of this study are to verify the result of the surgical treatment of ALCAPA and to identify the postoperative changes of left ventricular dimensions and mitral regurgitation (MR), Material and Method: Fifteen patients operated on since 1985 were included in the study. The patients operated on before 1998 (n=9) showed heterogeneous properties with various surgical strategies and cardiopulmonary bypass techniques. However, six patients were operated on with the established surgical strategy since 1998; 1) Dual perfusion and dual cardioplegic solution delivery through ascending aorta and main pulmonary artery, 2) Coronary transfer by rolled-conduit made of pulmonary artery wall flap, and 3) Additional mitral valvular procedure was not peformed. Result: Median age of the study group was 6 months (1 month to 34 years). The operative methods were left subclavian artery to left coronary artery anastomosis in 1, simple ligation in 2, Takeuchi operation in 2, and coronary reimplantation in 10 patients. The mean follow up period was 5.5<5.8 years (2 months 14 years), There were one early death (6.7%) and one late death. Overall 5-year survival rate was 85.6$\pm$9.6%. The Z-value of left ventricular end-diastolic and end-systolic dimensions were 6.4$\pm$3.0 and 5.1 $\pm$3.6 preoperatively, and decreased to 1.7$\pm$ 1.9 and 0.8$\pm$ 1.6 in 3 months (p<0.05). Significant preoperative MR was identified in 6 patients (40%) and all the patients showed immediate improvement of MR within f month postoperatively. There were 3 cases of reoperation due to coronary anastomosis site stenosis and recurrence of MR. However, there was no mortality nor late reoperation in the patients operated on after 1998. Conclusion: The surgical treatment of ALCAPA showed favorable survival and early recovery of ventricular dimensions and mitral valvular function. Although long-term reintervention was required in some cases of earlier period, all the cases after 1998 showed excellent surgical outcome without long-term problem.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

The Predictable Factors for the Mortality of Fatal Asthma with Acute Respiratory Failure (호흡부전을 동반한 중증천식환자의 사망 예측 인자)

  • Park, Joo-Hun;Moon, Hee-Bom;Na, Joo-Ock;Song, Hun-Ho;Lim, Chae-Man;Lee, Moo-Song;Shim, Tae-Sun;Lee,, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.356-364
    • /
    • 1999
  • Backgrounds: Previous reports have revealed a high morbidity and mortality in fatal asthma patients, especially those treated in the medical intensive care unit(MICU). But it has not been well known about the predictable factors for the mortality of fatal asthma(F A) with acute respiratory failure. In order to define the predictable factors for the mortality of FA at the admission to MICU, we analyzed the relationship between the clinical parameters and the prognosis of FA patients. Methods: A retrospective analysis of all medical records of 59 patients who had admitted for FA to MICU at a tertiary care MICU from January 1992 to March 1997 was performed. Results: Over all mortality rate was 32.2% and 43 patients were mechanically ventilated. In uni-variate analysis, the death group had significantly older age ($66.2{\pm}10.5$ vs. $51.0{\pm}18.8$ year), lower FVC($59.2{\pm}21.1$ vs. $77.6{\pm}23.3%$) and lower $FEV_1$($41.4{\pm}18.8$ vs. $61.l{\pm}23.30%$), and longer total ventilation time ($255.0{\pm}236.3$ vs. $98.1{\pm}120.4$ hour) (p<0.05) compared with the survival group (PFT: best value of recent 1 year). At MICU admission, there were no significant differences in vital signs, $PaCO_2$, $PaO_2/FiO_2$, and $AaDO_2$, in both groups. However, on the second day of MICU, the death group had significantly more rapid pulse rate ($121.6{\pm}22.3$ vs. $105.2{\pm}19.4$ rate/min), elevated $PaCO_2$ ($50.1{\pm}16.5$ vs. $41.8{\pm}12.2 mm Hg$), lower $PaO_2/FiO_2$, ($160.8{\pm}59.8$ vs. $256.6{\pm}78.3 mm Hg$), higher $AaDO_2$ ($181.5{\pm}79.7$ vs. $98.6{\pm}47.9 mm Hg$), and higher APACHE III score ($57.6{\pm}21.1$ vs. $20.3{\pm}13.2$) than survival group (p<0.05). The death group had more frequently associated with pneumonia and anoxic brain damage at admission, and had more frequently developed sepsis during disease progression than the survival group (p<0.05). Multi-variate analysis using APACHE III score and $PaO_2/FiO_2$, ratio on first and second day, age, sex, and pneumonia combined at admission revealed that APACHE III score (40) and $PaO_2/FiO_2$ ratio (<200) on second day were regarded as predictive factors for the mortality of fatal asthma (p<0.05). Conclusions: APACHE III score ($\geq$40) and $PaO_2/FiO_2$ ratio (<200) on the second day of MICU, which might reflect the response of treatment, rather than initially presented clinical parameters would be more important predictable factors of mortality in patients with FA.

  • PDF

Role of Catecholamines in Ventricular Fibrillation (Catecholamines에 관(關)하여 -제4편(第四編) : 심실전동발생(心室顫動發生)에 있어서의 catecholamines의 의의(意義)-)

  • Lee, Woo-Choo
    • The Korean Journal of Pharmacology
    • /
    • v.19 no.1
    • /
    • pp.15-35
    • /
    • 1983
  • Although it has been well known that ventricular fibrillation is the most important complication during hypothermia, much investigation has failed to show the exact nature of the etiology of ventricular fibrillation. Recently, there has been considerable research on the relationship between sympathetic activity and ventricular fibrillation under hypothermia. Cardiac muscle normally contains a certain amount of norepinephrine and the dramatic effect of this catecholamines on the cardiac muscle is well documented. It is, therefore, conceivable that cardiac catecholamines might exert an influence on the susceptibility of heart muscle to tachycardia, ventricular fibrillation and arrhythmia, under hypothermia. Hypothermia itself is stress enough to increase tonus of sympatheticoadrenal system. The normal heart is supplied by an autonomic innervation and is subjected to action of circulating catecholamines which may be released from the heart. If the reaction of the heart associated with a variable amount of cardiac catecholamines is. permitted to occur in the induction of hypothermia, the action of this agent on the heart has not to be differentiated from the direct effects of cooling. The studies presented in this paper were designed to provide further information about the cardio-physiological effects of reduced body temperature, with special reference to the role of catecholamines in ventricular fibrillation. Healthy cats, weighing about 3 kg, were anesthetized with pentobarbital(30 mg/kg) intraperitoneally. The trachea was intubated and the endotracheal tube was connected to a C.F. Palmer type A.C. respirator. Hypothermia was induced by immersing the cat into a ice water tub and the rate of body temperature lowering was $1^{\circ}C$ per 5 to 8 min. Esophageal temperature and ECG (Lead II) were simultaneously monitored. In some cases the blood pH and serum sodium and potassium were estimated before the experiment. After the experiment the animals were killed and the hearts were excised. The catecholamines content of the cardiac muscle was measured by the method of Shore and Olin (1958). The results obtained are summarized as follows. 1) In control animal the heart rate was slowed as the temperature fell and the average pulse rates of eight animals were read 94/min at $31^{\circ}C$, 70/min at $27^{\circ}C$ and 43/min at $23^{\circ}C$ if esophageal temperature. Ventricular fibrillation was occurred with no exception at a mean temperature of $20.3^{\circ}C(21-l9^{\circ}C)$. The electrocardiogram revealed abnormal P waves in each progressive cooling of the heart. there was, ultimately, a marked delay in the P-R interval, QRS complex and Q-T interval. Inversion of the T waves was characteristic of all animals. The catecholamines content of the heart muscle excised immediately after the occurrence of ventricular fibrillation was about thirty percent lower than that of the pre-hypothermic heart, that is, $1.0\;{\mu}g/g$ wet weight compared to the prehypothermic value of $1.41\;{\mu}g/g$ wet weight. The changes of blood pH, serum sodium and potassium concentration were not remarkable. 2) By the adrenergic receptor blocking agent, DCI(2-3 mg/kg), given intramuscularly thirty minutes before hypothermia, ventricular fibrillation did not occur in one of five animals when their body temperature was reduced even to $16^{\circ}C$. These animals succumbed at that low temperature, and the changes of heart rate and loss of myocardial catecholamines after hypothermia were similar to those of normal animals. The actual effect of DCI preventing the ventricular fibrillation is not predictable. 3) Administration of reserpine(1 mg/kg, i.m.) 24 hours Prior to hypothermia disclosed reduced incidence of ventricular fibrillation, that is, six of the nine animals went into fibrillation at an average temperature of $19.6^{\circ}C$. By reserpine myocardial catecholamines content dropped to $0.045\;{\mu}g/g$ wet weight. 4) Bretylium pretreatment(20 mg/kg, i.m.), which blocks the release of catecholamines, Prevented the ventricular fibrillation under hypothermia in four of the eight cats. The pulse rate, however, was approximately the same as control and in some cases was rather slower. 5) Six cats treated with norepinephrine(2 mg/kg, i.m.) or DOPA(50 mg/kg) and tranylcypromine(10 mg/kg), which tab teen proved to cause significant increase in the catecholamines content of the heart muscle, showed ventricular fibrillation in all animals under hypothermia at average temperature of $21.6^{\circ}C$ and the pulse rate increased remarkably as compared with that of normal. Catecholamines content of cardiac muscle of these animals markedly decreased after hypothermia but higher than control animals. 6) The functional refractory periods of isolated rabbit atria, determined by the paired stimulus technique, was markedly shortened by administration of epinephrine, norepinephrine and isoproterenol. 7) Adrenergic beta-blocking agents, such as pronethalol, propranolol and sotalol(MJ-1999), inhibited completely the shortening of refractory period induced by norepinephrine. 8) Pretreatment with either phenoxftenbamine or phentolamine, an adrenergic alphatlocking agent, did not modify the decrease in refractory period induced by norepinephrine. From the above experiment it is possible to conclude that catecholamines play an important role in producing ventricular fibrillation under hypothermia. The shortening of the refractorf period of cardiac muscle induced by catecholamines mar be considered as a partial factor in producing ventriculr fibrillaton and to be mediated by beta-adrenergic receptor.

  • PDF