• Title/Summary/Keyword: $CO_2$ source

Search Result 1,648, Processing Time 0.032 seconds

Experimental Study on $CO_2$ Level Fluctuation by Door-opening of Subway (전동차 출입문 개폐에 따른 객실 이산화탄소 농도변화의 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young;Ham, Dae-Joo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1652-1655
    • /
    • 2008
  • Indoor air quality (IAQ) of subway becomes a key issue as the IAQ guidelines for public transportation published. There are two major sources regarding IAQ of subway; One is the sources coming from outdoor air and the other is sources of inside. Particulate matters smaller than 10 micrometer (PM10) and carbon dioxide ($CO_2$) are recognized as the one of the most severe pollutants in Korea. The source of PM10 is mainly coming from outdoor air, however, the source of $CO_2$ is coming from passengers exhaust. According to the guidelines, the level of $CO_2$ should be lower than 2500ppm for normal operating time and lower than 3500ppm for rush hour. In order to satisfy these guidelines, the volume of mechanical ventilation should be increase which consumes extra energy for heating or cooling. Therefore, the optimum volume of mechanical ventilation should be calculated for energy saving. In this study, we measured the natural ventilation rate by door-opening which can reduce the load of mechanical ventilation. The $CO_2$ generator and sensors were used to measure the change of $CO_2$ by periodic door-opening of subway.

  • PDF

Non-dispersive infrared carbon dioxide sensor with an externally exposed optical cavity (광 도파관이 외부로 노출된 구조를 가지는 비분산적외선 이산화탄소 센서)

  • Jung, Dong Geon;Lee, Junyeop;Do, Nam Gon;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.456-460
    • /
    • 2021
  • In this study, a Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO2) sensor with an externally exposed optical cavity is proposed for improving sensitivity. NDIR CO2 sensors with high performance must use a lamp-type infrared (IR) source with a strong IR intensity. However, a lamp-type IR source generates high thermal energy that induces thermal noise, interfering with the accuracy of the CO2 concentration measure. To solve this problem, the optical cavity of the NDIR CO2 sensor is exposed to quickly dissipate heat. As a result, the proposed NDIR CO2 sensor has a shorter warm-up time and a higher sensitivity compared to the conventional NDIR CO2 sensor.

Comparison the reference ion chamber in using the radioactive check source and field ion chamber for output dose for Co-60 source of remote afterloading system (시험선원을 이용한 기준 전리함의 감도변화와 임상필드전리함의 성능 안정성 비교)

  • 최태진
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.141-146
    • /
    • 2001
  • It is well known that assurance of the radiation therapy needs for an accuracy of $\pm$ 5 % in the delivery of an absorbed dose to target volume. Therefore, the dose evaluation of brachytherapy source and/or linear accelerate beam must be a stability with accuracy. In an advanced country, they recommended to use the radioactive check source for reference air ionization chamber for a stable response of radiation field chamber. In this experiments, the radioactive source Sr-90 and PR-05 air ionization chamber were used for standard source and reference ion chamber. The response of reference ion chamber showed as an 1.000$\pm$ 0.010 uncertainty for 10 years long and the evaliuation f dose discrepancy of clinical field ion chamber showed as 0.997 $\pm$0.011 in a $^{60}$ Co brachytherapy soruce. In our experiments, we can assuarance the long halflife standard source is reliable to preserve the calibration factor of reference chamber in stability.

  • PDF

On the Environmental hnpact Assessment of Traditional Tombs : The Source and Sink of $O_2$ and $CO_2$ (묘지가 환경에 미치는 영향 : 산소와 이산화탄소의 source 및 sink)

  • 정용승;이홍식
    • Journal of Environmental Science International
    • /
    • v.2 no.2
    • /
    • pp.115-121
    • /
    • 1993
  • At the close of the year 1990, tombs in south Korea will cover the area of 940 km2, which is 0.9% of the entire landspace. Annual increase of 200,000 tombs is encroaching on landspace by 10 $km^2$. It4 is estimated that the decrease in the forest area caused by tombs results a decrease both in the production of $0_2$ by 912,000 tons and in the absorption of $CO_2$ by 1,2454,800tons per year. As a result, there will be an increase in the amount of $CO_2$, which is one of the factors that cause the greenhouse effect.

  • PDF

Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample (저준위 토양시료를 이용한 콤프턴 연속체 억제의 측정 및 몬테카롤로 시뮬레이션 평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.123-131
    • /
    • 2018
  • This study compared PENELOPE with measured values from low energy peak to high energy peak to reduce peak to compton ratio and continuum background spectrum using $^{60}Co$, $^{137}Cs$ and mixed volume source. In addition, the change in backscattering and compton edge efficiency was compared with that of PENELOPE through changes in the vicinity of low energy. The results from the mixed volume source are applied to the soil samples to determine how much the minimum detection limits of the soil samples are reduced in the suppression and unsuppressed mode. The compton suppression of the low energy region of $^{60}CO$ (1,173 keV) was considerable, and the Compton edge RF for the $^{137}Cs$ (661 keV) peak was 2.8. In particular, the $^{60}Co$ source emits coincidence gamma rays of 1,173.2 keV and 1,332.5 keV, so compton inhibition was reduced by approximately 21%. RF of compton edges of 1,173 keV and 1,332 keV emitted from a $^{60}Co$ source was 3.2 and 3.4, and the peak to compton edge ratio was improved to 8: 1. And Compared with Penelope, the uncertainty was well within 2%. In compton unsuppressed mode, MDA values of 661 keV, 1,173 keV and 1,332 keV were 0.535, 0.173 and 0.136 Bq/kg, respectively, but decreased in compton suppressed mode to 0.121, 0.00826 and 0.00728 Bq/kg. Thus, Compton suppressed could reduce the background radioactivity and the radioactivity contained in the detector itself.

Greenhouse Gas Reduction Scenario from LEAP Model Application to a University Campus-For Hanyang University Ansan Campus (LEAP 모델 적용을 통한 대학단위 온실가스 감축안 도출 - 한양대학교 안산캠퍼스 대상으로)

  • Park, Hyo-Jeong;Jung, Hye-Jin;Yi, Seung-Muk;Park, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.280-287
    • /
    • 2012
  • The sources of greenhouse gases (GHG) at Hanyang University Ansan campus, including direct sources, indirect sources, and others, were investigated in order to establish the GHG inventory. Emission of GHG was calculated with the energy use from each source from 2007 and 2009. The indirect emission (56.7%) due to the electricity significantly contributed to total GHG emission. The scenario for the GHG reduction was designed for both campus administration and members. The reduction potential of GHG was simulated from 2007 to 2020 using Long-range Energy Alternatives Planning (LEAP) model. In case of GHG reduction scenario by campus administration, the GHG can be reduced by 63.34 ton $CO_{2eq}/yr$ for stationary combustion in the direct source, by 221.1 ton $CO_{2eq}/yr$ for mobile combustion in the direct source, and by 4,637.34 ton $CO_{2eq}/yr$ for lighting in the indirect source, compared to 2020 Business As Usual (BAU). In case of GHG reduction action scenario by campus members, the reduction potential of GHG was 1293.76 ton $CO_{2eq}/yr$. Overall, the total GHG emissions in 2020 by the both scenarios can be decreased by 24% compared to 2020 BAU.

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

Effect of Short Circuit Time Ratio and Current Control Pattern on Spatter Generation in $CO_2$ Welding ($CO_2$용접의 스패터 발생에 미치는 단락시간비 및 단락전류 파형제어의 영향)

  • 조상명
    • Journal of Welding and Joining
    • /
    • v.21 no.1
    • /
    • pp.48-53
    • /
    • 2003
  • The object of this study is to examine the effect of short circuit time ratio (SCTR) and current rise delay time (Td) on the spatter generation at low and medium current range in $CO_2$ welding. The spatter was evaluated by the weight generated in the welding of bead-on-plate for 30 seconds (3 times). Td was varied by order of 0, 0.4, 0.8 and 1.2 msec. At each Td, the short circuit time ratio was varied by the output voltage of the welding power source. In the low current range, it was found that the optimum SCTR was 20~25%, and the minimum spatter generation weight was obtained in the case of Td=0.4msec and SCTR=22% even though the remarkable difference was not showed by the application of Td. In the medium current range, it was confirmed that the arc was stable though the SCTR was increased from 20% to 40% by the control of current wave. Spatter generation weight depended on the variation of Td, and the lowest value of spatter generation weight occurred at Td=0.8~1.2msec.

Geochemical Water Quality and Genesis of Carbonated Dalki Mineral Water in the Chungsong Area, Kungpook (경북청송지역 달기 탄산약수의 지화학적 수질특성과 생성기원)

  • 정찬호
    • Economic and Environmental Geology
    • /
    • v.32 no.5
    • /
    • pp.455-468
    • /
    • 1999
  • Carbonated mineral waters fo $Ca(Mg)-HCO_3$ type spring out fissure of Jurassic granite in the valley floor of the Chungsong area. The water has been long as a Dalki medicinal water because of its unique therapeutic effect against clacium deficit, stomach and skin troubles, ect. The water has a high $CO_2$ concentration ($P_{CO_2}$=0.51~1.12atm) and exhibits strong pH buffering (5.9~6.26) by $H_2CO_3/HCO_3$ couple. Electrical conductivity ranges from 1,900 to 3100 $\mu$S/cm. Environmental isotopic data $(^{2}H/^{1}H, ^{18}O/^{16}O \;and \;^3H)$ indicates that the water is of meteoric origin recharged in the Cretaceous sedimetary strata distributed in upper part of the catchment area at least before 1950s, The high $P_{co_2}$ and carbon isotope data (${\delta}^{13}C=-3\sim-0.2\textperthousand$) suggest that the potential source of carbonated mineral water was originated in deep-seated $CO_2$ as wel as aboundant carbonate minerals of sedimentary desimetary rocks. The major source minerals of the dissoved species in the carbonated mineral water appear to be carbonate minerals, albite and K-feld-spar in sedimentrary rocks.

  • PDF