• 제목/요약/키워드: $CO_2$ leakage

검색결과 383건 처리시간 0.024초

Glass Ionomer Root Canal Sealer의 치근단 미세누출에 관한 연구 (A STUDY ON THE APICAL MICROLEAKAGE OF GLASS IONOMER ROOT CANAL SEALER)

  • 이소영;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.236-246
    • /
    • 1998
  • The purpose of this study was to compare the degree of micro- leakage of new glass ionomer root canal sealer, Ketac-Endo(ESPE Co., Seefeld, Germany) with that of AH-26(De Trey Co., Ltd., U.S.A.). Root canal treatment using K -file, H -file, Gate Glidden drill was conducted on 49 extracted single-rooted teeth. 45 teeth were randomly divided into 3 experimental groups(15 teeth per group) and 4 teeth were used as the control group. Group 1 was used AH -26 sealer with the lateral condensation method for canal filling, group 2 was used Ketac-Endo with the single cone method and group 3 was used Ketac-Endo with the lateral condensation method. The control group was obturated with the single cone method without sealer. The teeth were covered with two coats of nail varnish after 48 hours of obturation. The teeth were immersed in India ink for 1 week and cleaned with methyl salicylate and then the degree of dye penetration were measured with stereomicroscope. The data were analyzed statistically by one-way ANOVA. The results were as follows: 1. 7 teeth in group 1, 5 in group 2, and 3 in group 3, were showed evidence of microleakage implying appropriate canal filling. 2, The mean average of microleakage was $0.17{\pm}0.32mm$ in group 1, $0.30{\pm}0.37mm$ in group 2. $0.10{\pm}0.21mm$ in group 3, showing that canal filling using the lateral condensation canal filling method with Ketac-Endo showed the least microleakage and using the single cone method with Ketac-Endo showed the largest amount of microleakage, 3. There were no statistically significant difference in the variation of microleakage among groups. From the results above, Ketac-Endo which has the advantage of glass ionomer, whether using the single cone method or the lateral condensation method, showed similar results as AH-26, but for clinical application it is thought that were studies on the properties of Ketac-Endo should be followed.

  • PDF

미주 신경의 전기적 자극으로 유발된 백서의 기도내 혈장 유출에 대한 FK224의 효과 (Effects of FK224, a $NK_1$ and $NK_2$ Receptor Antagonist, on Plasma Extravasation of Neurogenic Inflammation in Rat Airways)

  • 심재정;이상엽;이상화;박상면;서정경;조재연;인광호;유세화;강경호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권5호
    • /
    • pp.744-751
    • /
    • 1995
  • 연구배경: 여러 종류의 자극으로 감각신경(C-fiber)의 말단부에서 분비되는 신경단백질인 substance P와 neurokinin A는 기관지 평활근의 수축, 점막의 혈장 유출 및 점액의 과분비를 일으켜 기관지 천식 발병 기전에 중요한 역활을 한다. 이러한 기도 신경단백질은 $NK_1$, $NK_2$, $NK_3$ 등의 3종류의 수용체를 통하여 작용하며, $NK_1$ 수용체에 주로 작용하는 substance P는 기도의 혈관확장과 혈장 유출에 관여하며 $NK_2$ 수용체에 작용하는 neurokinin A는 기도의 수축에 주로 작용하며 기도혈장 유출에도 관여하는 것으로 알려져 있다. 목적: 저지들은 백서의 미주신경인 비교감 및 비부교감 신경을 전기적 자극으로 유발된 기도 혈장 유출에서 $NK_1$$NK_2$ 수용체 차단제인 FK224를 이용하여 기도내 신경성 염증에서 혈장유출에 대한 효과를 기도 부위별로 확인하였다. 대상 및 방법: 백서 21마리를 7마리씩 3군으로 나누어 미주신경에 전기적 자극을 하지 않은 대조군(control group), 2분간 자극한 군(NANC2군)과 신경 단백 수용체 차단제인 FK224를 미주신경 자극 전에 사용한 군(FK224군)에서 Evans blue dye를 이용하여 기도 부위별 혈장 유출의 정도를 각 군간에 비교하여 다음과 같은 결과를 얻었다. 결과: 1) 2분간 신경 자극한 군(NANC2군)은 대조군에 비하여 기관에서 49.7(${\pm}2.5$)ng/mg으로 353%, 주기관지에서 38.7(${\pm}2.8$)ng/mg으로 221%의 증가와 말초기관지 19.1(${\pm}1.6$)ng/mg으로 151%로 혈장 유출이 모두 유의하게 높았으며(p<0.05), 주로 상부 기도에서 혈장 유출 정도가 심하였으나, 폐실질은 13.0(${\pm}1.8$)ng/mg, 76%로 대조군과 차이는 없었다(p>0.05). 2) 신경 단백질 수용체 차단제를 사용한 FK224군은 2분간 신경 자극한 군에 비하여 기관에서 24.3(${\pm}2.2$)ng/mg으로 49%, 주기관지에서 22.3(${\pm}1.6$)ng/mg 으로 58%의 억제와 말초기관지 13.3(${\pm}0.8$) ng/mg으로 70%로 혈장 유출이 모두 유의하게 감소되었다(p<0.05). 결론: 이상의 결과에 의하면 백서에서 미주신경(NANC)의 전기적 자극으로 유발된 혈장유출은 기도에서만 발생되고 주로 상부기도에서 혈장유출이 심하며, $NK_1$$NK_2$ 수용체 차단제인 FK224를 전처치하여 substance P와 neurokinin A의 수용체 차단으로 기도 혈장 유출이 억제됨을 알 수 있었다.

  • PDF

일산화탄소중독(一酸化炭素中毒)의 발생실태(發生實態)에 대(對)한 역학적고찰(疫學的考察) (An Epidemiological Study on the Incidence of CO poisoning in Korea)

  • 이강현;최용어;김찬호;윤덕노
    • Journal of Preventive Medicine and Public Health
    • /
    • 제4권1호
    • /
    • pp.95-105
    • /
    • 1971
  • Carbon monoxide poisoning is one of the most serious health hazards in Korea. Although the incidence rate has been assumed to be the highest in the world, there has been no avaiable reports as far as the annual & nation-wide incidence are concered. Authors analyzed the incidence reports from 1965 to 1970 filed by the National Police & also made incidence survey on Seoul area in 1968 & 1969. The results of these surveys informed us that the official police reports are very much underevaluated. The stochastic estimations of the generel incidence were made based on the informations which were obtained through incidence survey made in Seoul area. The findings obtained are as follows; 1. The annual incidence of CO poisoning tends to increase since 1965. 2. The incidence is higher in the urban area & the incidence in Seoul is the highest in the world. 3. The frequency of incidence is the highest in the December. 4. The main causes of poisoning are the gas leakage from 'ondol' floor & the leaking of gas from kitchen to room through the connecting door. 5. The incidence survey made in Seoul area revealed that the official police reports are underevaluated around one-eighth of actual incidence. 6. The health hazards induced by CO poisoning is greater than those caused by 19 Class I & Class II communicable diseases.

  • PDF

Cross-Linked PVP 게이트 유기 박막트랜지스터 (Organic Thin Film Transistors with Cross-Linked PVP Gates)

  • 장지근;오명환;장호정;김영섭;이준영;공명선;이영관
    • 마이크로전자및패키징학회지
    • /
    • 제13권1호통권38호
    • /
    • pp.37-42
    • /
    • 2006
  • 유기 박막트랜지스터(OTFTs)제작에서 PVP-게이트 절연막의 형성과 처리가 소자성능에 미치는 영향을 조사하였다. 유기 게이트 용액의 제조에서는 polyvinyl 계열의 PVP(poly-4-vinylphenol)를 용질로, PGMEA (propylene glycol monomethyl ether acetate)를 용매로 사용하였다. 또한 열경화성 수지인 poly(melamine-co-formaldehyde)를 경화제로 사용하여 유기 절연막의 cross-link를 시도하였다. MIM 시료의 전기적 절연 특성을 측정한 결과, PVP-기반 유기 절연막은 용액의 제조에서 PGMEA에 대한 PVP와 poly (melamine-co-formaldehyde)의 농도를 증가시킬수록 낮은 누설전류 특성을 나타내었다. OTFT 제작에서는 PGMEA에 대해 PVP를 20 wt%로 섞은 PVP(20 wt%) copolymer와 5 wt%와 10 wt%의 poly(melamine-co-formaldehyde)를 경화제로 추가한 cross-linked PVP(20 wt%)를 게이트 유전 재료로 사용하였다. 제작된 트랜지스터들에서 전계효과 이동도는 5 wt % cross-linked PVP(20 wt%) 소자에서 $0.31cm^2/Vs$로, 그리고 전류 점멸비는 10 wt% cross-linked PVP(20 wt%) 소자에서 $1.92{\times}10^5$으로 가장 높게 나타났다.

  • PDF

소결시간에 따른 ZnO-Pr6O11계 바리스터의 전기적, 유전적 특성 (Electrical and Dielectric Properties of ZnO-Pr6O11 Varistors with Sintering Time)

  • 남춘우;박종아;유대훈
    • 한국전기전자재료학회논문지
    • /
    • 제18권6호
    • /
    • pp.543-549
    • /
    • 2005
  • The electrical and dielectric properties of $ZnO-Pr_6O_{11}-CoO-Cr_2O_3-based$ varistors were investigated in the sintering time range of $1\~3$ h. Increasing sintering time improved the densification of ceramics, whereas deteriorated the nonlinearity, in which the nonlinear exponent greatly decreased from 55.3 to 38.2 and the leakage current increased from 0.1 to $1.1\;{\mu}A$. The donor concentration and density of interface states increased in the range of $(1.06\~1.60)\times10^8/cm^3\;and\;(3.15\~3.67)\times10^{12}/cm^2$ with increasing sintering time, respectively. while, in dielectric properties, the increase of sintering time increased in the range of $0.0228\~0.0505$ in tans and $1.32\~1.36\;{\mu}s$ in relaxation time.

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

Electrical resistivity survey and interpretation considering excavation effects for the detection of loose ground in urban area

  • Seo Young Song;Bitnarae Kim;Ahyun Cho;Juyeon Jeong;Dongkweon Lee;Myung Jin Nam
    • Geomechanics and Engineering
    • /
    • 제35권2호
    • /
    • pp.109-119
    • /
    • 2023
  • Ground subsidence in urban areas due to excessive development and degraded underground facilities is a serious problem. Geophysical surveys have been conducted to estimate the distribution and scale of cavities and subsidence. In this study, electrical resistivity tomography (ERT) was performed near an area of road subsidence in an urban area. The subsidence arose due to groundwater leakage that carried soil into a neighboring excavation site. The ERT survey line was located between the main subsidence area and an excavation site. Because ERT data are affected by rapid topographic changes and surrounding structures, the influence of the excavation site on the data was analyzed through field-scale numerical modeling. The effect of an excavation should be considered when interpreting ERT data because it can lead to wrong anomalous results. A method for performing 2D inversion after correcting resistivity data for the effect of the excavation site was proposed. This method was initially tested using a field-scale numerical model that included the excavation site and subsurface anomaly, which was a loosened zone, and was then applied to field data. In addition, ERT data were interpreted using an existing in-house 3D algorithm, which considered the effect of excavation sites. The inversion results demonstrated that conductive anomalies in the loosened zone were greater compared to the inversion that did not consider the effects of excavation.

밀봉 재료에 따른 페롭스카이트 막의 산소투과 특성 (Effect of Sealant Materials on Oxygen Permeation in Perovskite Oxide Membrane)

  • 김종표;박정훈;윤여일
    • 공업화학
    • /
    • 제19권4호
    • /
    • pp.382-387
    • /
    • 2008
  • 착체중합법을 이용하여 $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ 조성의 산화물을 합성하였으며, 합성된 분말은 압축 성형 후 $1080^{\circ}C$에서 소결하여 치밀한 페롭스카이트 분리막을 제조하였다. 밀봉 재료로 gold ring, Pyrex ring 및 Pyrex 분말을 사용하여 가스누출 실험을 수행하였다. $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ 분리막의 산소투과량 분석결과 온도가 증가함에 따라 산소투과량은 증가하였고, $900^{\circ}C$에서 $0.74mL/min{\cdot}cm^2$의 값을 나타내었다. $950^{\circ}C$에서 밀봉 재료에 따른 투과 특성 분석 결과, gold ring을 이용할 경우 높은 산소투과량을 보인 반면, Pyrex를 밀봉재로 사용할 경우 낮은 투과량을 보였다. 이는 Pyrex를 밀봉재로 이용할 경우 분리막 표면으로 유리가 침투하여 유효 산소투과면적을 감소시켰기 때문이며, 광화학 현미경 분석으로 Pyrex 유리의 확산 침투를 확인하였다.

ZnO-Zn2BiVO6-Co3O4 바리스터의 전류-전압 및 임피던스의 온도 (Current-Voltage and Impedance Characteristics of ZnO-Zn2BiVO6-Co3O4 Varistor with Temperature)

  • 홍연우;김유비;백종후;조정호;정영훈;윤지선;박운익
    • 센서학회지
    • /
    • 제25권6호
    • /
    • pp.440-446
    • /
    • 2016
  • This study introduces the characteristics of current-voltage (I-V) and impedance variance for $ZnO-Zn_2BiVO_6-Co_3O_4$ (ZZCo), which is sintered at $900^{\circ}C$, according to temperature changes. ZZCo varistor demonstrates dramatic improvement of non-linear coefficient, ${\alpha}=66$, with lower leakage current and higher insulating resistivity than those of ZZ ($ZnO-Zn_2BiVO_6$) from the aspect of I-V curves. While both systems are thermally stable up to $125^{\circ}C$, ZZCo represents a higher grain boundary activation energy with 1.05 eV and 0.94 eV of J-E-T and from IS & MS, respectively, than that of ZZ with 0.73 eV and 0.82 eV of J-E-T and from IS & MS, respectively, in the region above $180^{\circ}C$. It could be attributed to the formation of $V^*_o$(0.41~0.47 eV) as dominant defect in two systems, as well as the defect-induced capacitance increase from 781 pF to 1 nF in accordance with increasing temperature. On the other hand, both the grain boundary capacitances of ZZ and ZZCo are shown to decrease to 357 pF and 349 pF, respectively, while the resistances systems decreased exponentially, in accordance with increasing temperature. So, this paper suggests that the application of newly formed liquid phases as sintering additives in both $Zn_2BiVO_6$ and the ZZCo-based varistors would be helpful in developing commercialized devices such as chips, disk-type ZnO varistors in the future.

마이크로파 여기 프라즈마법으로 제조한 강자성 터널링 접합의 국소전도특성 (Local Current Distribution in a Ferromagnetic Tunnel Junction Fabricated Using Microwave Excited Plasma Method)

  • 윤대식;김철기;김종오
    • 한국자기학회지
    • /
    • 제13권2호
    • /
    • pp.47-52
    • /
    • 2003
  • DC 마그네트론 스파터법과 RLSA(Radial Line Slot Antenna)을 이용한 마이크로파 여기 프라즈마를 이용하여 Ta/Cu/Ta/NiFe/Cu/Mn$_{75}$Ir$_{25}$/ $Co_{70}$Fe$_{30}$/Al-oxide 구조의 접합을 제조한 후, contact-mode AM(Atomic Force Microscope)을 이용하여 Al 산화막의 국소전도 특성의 평가를 수행하였다. AFM 동시전류측정으로부터, 얻어지는 표면상과 전류상은 대응하지 않는다. 국소 전류-전압(I-V)의 측정 결과, 전류상은 절연층의 barrier height의 분포를 나타내고 있다는 것을 알았다.다.다.