• 제목/요약/키워드: $CO_2$ generator

검색결과 215건 처리시간 0.02초

발전기보수유지계획을 고려한 CO2배출량의 추정 (Assessment of the CO2 Emission Considering the Generator Maintenance Scheduling)

  • 전동훈;박정제;오태곤;조경희;최재석;백웅기
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1507-1513
    • /
    • 2010
  • The $CO_2$ emission can be decreased due to freedom of generator maintenance scheduling(GMS). This paper proposes assessment of $CO_2$ emission considering generator maintenance scheduling(GMS) and evaluates effect of the GMS on $CO_2$ emission. And also, this paper assesses the $CO_2$ emission and the probabilistic production cost simulation of nuclear and thermal power generators considering operation of hydro and pumped generator. The minimum reliability criterion level satisfied production cost minimization function model is used in this paper. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system in Korea in 2010.

온실용 축열 연소기형 이산화탄소 발생기의 배기 및 열회수 특성 (Emission and heat recovery characteristics of heat recovery and combustor-type CO2 generator for greenhouses)

  • 최병철;이정현
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.52-59
    • /
    • 2014
  • The purpose of this study is to evaluate the performance of after-treatment equipment and thermal storage devices for a heat recovery and combustor-type $CO_2$ generator fuelled a kerosene. To reduce the levels of harmful exhaust gases produced by a $CO_2$ generator, a catalyzed particulate filter(CPF) has been selected as an after-treatment device, by considering back pressure and exhaust gas temperature. The CO conversions of the catalyzed SiC filter(full plugging) were 92%, and the concentration of PM(particulate matter) was near ambient. A thermal recovery device was used to recover 13% of the heat energy from the exhaust gas through heat exchangers installed on the exhaust line of the $CO_2$ generator. 69% of the moisture within the exhaust gases was removed by condensing water, in order to minimize excessive humidity within the greenhouse.

CO2배출 최소화를 고려한 발전기보수유지계획의 수립 (Establishment of Generator Maintenance Scheduling Considering Minimization of CO2 Emissions)

  • 오태곤;백웅기;최재석
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.705-710
    • /
    • 2011
  • This paper proposes establishment of generator maintenance scheduling(GMS) considering minimization of $CO_2$ emissions. The objective function model to minimize $CO_2$ emissions is used in this paper. In this paper, and also, GMS is established due to freedom of GMS of generators owned by a designated generation company. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system model in Korea in 2010.

화력발전소의 발전출력과 $CO_2$ 대기배출량 계산 (Calculation of CO2 Emission and Generator Output of Thermal Power Plant)

  • 임정균;이상중
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.417-420
    • /
    • 2007
  • 1997년 교토 기후협약이 체결되었고, 우리나라도 2013 년부터 기후협약 규제가 거의 확실시 되고 있다. 화석 연료의 연소로 대부분의 전력 을 생산하는 발전 산업은 우리나라 CO2 배출량의 25%를 차지하고 있으며, 발전소의 전력 생산에 따른 CO2배출량의 계산은 매우 중요한 일이 되었다. 본 논문은 발전소의 시험data 와 IPCC (Intergovernmental Panel on Climate Change)의 온실가스 추계방법론을 이용하여 시간당 CO2 대기 배출량을 계산하는 방법을 제시한다. 발전출력에 대한 CO2 배출량을 계산하는 한 예를 도시하였다.

  • PDF

A Study on Optimization of Compact High-voltage Generator Based on Magnetic-core Tesla Transformer

  • Jeong, Young-Kyung;Youn, Dong-Gi;Lee, Moon-Qee
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1349-1354
    • /
    • 2014
  • This paper presents a compact and portable high-voltage generator based on magnetic-core Tesla transformer for driving an UWB high power electromagnetic source. In order to optimize the performance of the high-voltage generator, a novel open-loop cylindrical magnetic-core adopting the quad-division lamination structure is proposed and manufactured. The designed high-voltage generator using the proposed magnetic core has a battery-powered operation and compact size of $280mm{\times}150mm$ in length and diameter, respectively. The high-voltage generator can produce a voltage pulse waveform with peak amplitude of 450 kV, a rise time of 1.5 ns, and pulse duration of 2.5 ns at the 800 V input voltage.

포토 레지스트의 기술 동향과 화학 증폭형 포토레지스트에서의 광산 발생제의 연구 (Technology Trends for Photoresist and Research on Photo Acid Generator for Chemical Amplified Photoresist)

  • 김성훈;김상태
    • 통합자연과학논문집
    • /
    • 제2권4호
    • /
    • pp.252-264
    • /
    • 2009
  • Lithographic data obtained from PHS(polyhydroxy styrene) having various functionalities were investigated by using a photoacid generator based on diazo and onium type. Chemically amplified photoresist based on the KrF type photoresist was developed by using a photoacid generator and multi-functional resin. Thermal stability for the photoacid generator showed that the increase of loading amount of photoacid generator resulted in the decrease of glass transintion temperature (Tg). The photoacid generators having methyl, ethyl, or propyl group in their cationic structure produced T-top structure in pattern profile due to the effect of acid diffusion during the generation of acid in the resist. The increase of carbon chain length in the anionic structure of photoacid generators resulted in lower pattern resolution due to the interruption of acid diffusion.

  • PDF

지역별 CO2 배출량규제를 고려한 발전소 최적운전 알고리즘의 개발 (Development of algorism to optimal operation of Power Generation considering Regional Regulation of CO2 Emission)

  • 김용하;김영길;이평호;조현미;우성민
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1936-1941
    • /
    • 2010
  • This purpose of this paper is to propose a methodology for optimal generating operation in power system to minimize the cost of generation subject to not only system constraints but also regional $CO_2$ emission constraints. To solve this ELD problem calculated range limit on minimum and maximum power outputs by regional Equal Generator how each regional capacity is connected into one and expressed Equal Fuel Cost Function considering regional $CO_2$ emission constraints. Accordingly, being modified regional load, new power outputs considering regional $CO_2$ emission constraints were calculated by ELD. The proposed model for evaluating availability is tested on IEEE RTS(Reliability Test System)-24 in detail.

연기/CO 및 연기/열 복합형 IoT 멀티 화재 감지기의 화재감지실험 연구 (A Study on Fire Alarm Test of IoT Multi-Fire Detector combined Smoke/CO and Smoke/Temperature Sensors)

  • 손근식;소수현
    • 한국재난정보학회 논문집
    • /
    • 제17권2호
    • /
    • pp.236-244
    • /
    • 2021
  • 연구목적: 연기/CO/열 복합형 화재감지기와 무선 IoT통신을 결합한 IoT 멀티화재감지기를 개발하고 화재감지 실험을 통하여 연기/CO/열 복합형 IoT 멀티화재감지기의 화재감지성능을 확인하는 것을 목적으로 한다. 연구방법: 연기/CO 복합형 과 연기/열 복합형의 IoT 멀티화재감지기를 연기발생기와 면 심지 연소를 통하여 화재감지성능을 실험하였으며, 화제 신호를 발하는 기준을 확인하였다. 연구결과: 연기/CO 복합형 IoT 멀티 화재감지기는 면심지 연소 실험에서 화재를 감지하였으나 연기발생기 실험에서는 화재를 감지하지 않았다. 반면 연기/열 복합형 IoT 멀티 화재감지기는 두 실험 모두 화재를 감지하지 않았다. 결론: 연기/CO 복합형 IoT 멀티화재감지기는 CO가 포함된 연기만을 감지하였으며, 연기/열 복합형 IoT 멀티 화재감지기는 열의 부족에 의해 화재를 잠지하지 않았다. 이와 같은 결과로 개발된 IoT 멀티 화재감지기는 면심지 연소 실험과 연기발생기 실험을 통해 2가지 센서의 기준값 이상 신호를 검출하여야 화재 신호를 발한다는 것을 확인하였다.

레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석 (Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply)

  • 유지호;조종현;정민길;박성진;강광희
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.

일사량 감응 및 관수공급이 가능한 연소형 CO2 발생기 통합 제어시스템의 설계 (Design of Integrated Control System for Combustion Type CO2 Generator with Solar Radiation Sensitiveness and Irrigation Supply)

  • 김응곤
    • 한국전자통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.617-622
    • /
    • 2018
  • 시설원예 하우스 내부의 공기 밀폐나 유동상태에 직접적인 영향을 주는 송풍기, 측창 개폐기의 동시제어는 $CO_2$ 농도 관리에 필수적이다. 현재 농업인구 감소에 따른 개인당 경작면적 증가로 자동화 시스템과 통합제어의 요구가 꾸준히 증가하고 있는 실정이다. 본 논문에서는 $CO_2$발생기의 연료 및 연소공기 혼합비(공연비), 내 외부 환경에 따른 $CO_2$ 공급량의 제어와 $CO_2$ 공급에 있어 중요한 변수인 측정 개폐기와 같은 기존 설치기기를 동시에 제어할 수 있는 통합 제어시스템을 제안한다.