• Title/Summary/Keyword: $CO_2$ generator

Search Result 214, Processing Time 0.025 seconds

Assessment of the CO2 Emission Considering the Generator Maintenance Scheduling (발전기보수유지계획을 고려한 CO2배출량의 추정)

  • Jeon, Dong-Hoon;Park, Jeong-Je;Oh, Tae-Gon;Cho, Kyeong-Hee;Choi, Jae-Seok;Baek, Ung-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1507-1513
    • /
    • 2010
  • The $CO_2$ emission can be decreased due to freedom of generator maintenance scheduling(GMS). This paper proposes assessment of $CO_2$ emission considering generator maintenance scheduling(GMS) and evaluates effect of the GMS on $CO_2$ emission. And also, this paper assesses the $CO_2$ emission and the probabilistic production cost simulation of nuclear and thermal power generators considering operation of hydro and pumped generator. The minimum reliability criterion level satisfied production cost minimization function model is used in this paper. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system in Korea in 2010.

Emission and heat recovery characteristics of heat recovery and combustor-type CO2 generator for greenhouses (온실용 축열 연소기형 이산화탄소 발생기의 배기 및 열회수 특성)

  • Choi, Byungchul;Lee, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.52-59
    • /
    • 2014
  • The purpose of this study is to evaluate the performance of after-treatment equipment and thermal storage devices for a heat recovery and combustor-type $CO_2$ generator fuelled a kerosene. To reduce the levels of harmful exhaust gases produced by a $CO_2$ generator, a catalyzed particulate filter(CPF) has been selected as an after-treatment device, by considering back pressure and exhaust gas temperature. The CO conversions of the catalyzed SiC filter(full plugging) were 92%, and the concentration of PM(particulate matter) was near ambient. A thermal recovery device was used to recover 13% of the heat energy from the exhaust gas through heat exchangers installed on the exhaust line of the $CO_2$ generator. 69% of the moisture within the exhaust gases was removed by condensing water, in order to minimize excessive humidity within the greenhouse.

Establishment of Generator Maintenance Scheduling Considering Minimization of CO2 Emissions (CO2배출 최소화를 고려한 발전기보수유지계획의 수립)

  • Oh, Tae-Gon;Baek, Ung-Ki;Choi, Jae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.705-710
    • /
    • 2011
  • This paper proposes establishment of generator maintenance scheduling(GMS) considering minimization of $CO_2$ emissions. The objective function model to minimize $CO_2$ emissions is used in this paper. In this paper, and also, GMS is established due to freedom of GMS of generators owned by a designated generation company. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system model in Korea in 2010.

Calculation of CO2 Emission and Generator Output of Thermal Power Plant (화력발전소의 발전출력과 $CO_2$ 대기배출량 계산)

  • Lim, Jeong-Kyun;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.417-420
    • /
    • 2007
  • This paper proposes a method to calculate the amount of the CO2 emission w.r.t. generator MW output using the input-output coefficients of the thermal power plants. A calculation of CO2 emission for an LNG fired combined cycle power plant is demonstrated.

  • PDF

A Study on Optimization of Compact High-voltage Generator Based on Magnetic-core Tesla Transformer

  • Jeong, Young-Kyung;Youn, Dong-Gi;Lee, Moon-Qee
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1349-1354
    • /
    • 2014
  • This paper presents a compact and portable high-voltage generator based on magnetic-core Tesla transformer for driving an UWB high power electromagnetic source. In order to optimize the performance of the high-voltage generator, a novel open-loop cylindrical magnetic-core adopting the quad-division lamination structure is proposed and manufactured. The designed high-voltage generator using the proposed magnetic core has a battery-powered operation and compact size of $280mm{\times}150mm$ in length and diameter, respectively. The high-voltage generator can produce a voltage pulse waveform with peak amplitude of 450 kV, a rise time of 1.5 ns, and pulse duration of 2.5 ns at the 800 V input voltage.

Technology Trends for Photoresist and Research on Photo Acid Generator for Chemical Amplified Photoresist (포토 레지스트의 기술 동향과 화학 증폭형 포토레지스트에서의 광산 발생제의 연구)

  • Kim, Sung-Hoon;Kim, Sang-Tae
    • Journal of Integrative Natural Science
    • /
    • v.2 no.4
    • /
    • pp.252-264
    • /
    • 2009
  • Lithographic data obtained from PHS(polyhydroxy styrene) having various functionalities were investigated by using a photoacid generator based on diazo and onium type. Chemically amplified photoresist based on the KrF type photoresist was developed by using a photoacid generator and multi-functional resin. Thermal stability for the photoacid generator showed that the increase of loading amount of photoacid generator resulted in the decrease of glass transintion temperature (Tg). The photoacid generators having methyl, ethyl, or propyl group in their cationic structure produced T-top structure in pattern profile due to the effect of acid diffusion during the generation of acid in the resist. The increase of carbon chain length in the anionic structure of photoacid generators resulted in lower pattern resolution due to the interruption of acid diffusion.

  • PDF

Development of algorism to optimal operation of Power Generation considering Regional Regulation of CO2 Emission (지역별 CO2 배출량규제를 고려한 발전소 최적운전 알고리즘의 개발)

  • Kim, Yong-Ha;Kim, Young-Gil;Lee, Pyong-Ho;Jo, Hyun-Mi;Woo, Sung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1936-1941
    • /
    • 2010
  • This purpose of this paper is to propose a methodology for optimal generating operation in power system to minimize the cost of generation subject to not only system constraints but also regional $CO_2$ emission constraints. To solve this ELD problem calculated range limit on minimum and maximum power outputs by regional Equal Generator how each regional capacity is connected into one and expressed Equal Fuel Cost Function considering regional $CO_2$ emission constraints. Accordingly, being modified regional load, new power outputs considering regional $CO_2$ emission constraints were calculated by ELD. The proposed model for evaluating availability is tested on IEEE RTS(Reliability Test System)-24 in detail.

A Study on Fire Alarm Test of IoT Multi-Fire Detector combined Smoke/CO and Smoke/Temperature Sensors (연기/CO 및 연기/열 복합형 IoT 멀티 화재 감지기의 화재감지실험 연구)

  • Son, Geun­Sik;So, Soo­Hyun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.236-244
    • /
    • 2021
  • Purpose: The purpose of this study is to develop IoT multi-fire detectors combined smoke/carbon monoxide/heat and wireless IoT communication and to confirm the detect performance by smoke generator fire test and cotton wicks fire test. Method: The IoT multi-fire detector combined smoke and CO and combined smoke and heat were experimented the detect performance by smoke generator test and fire test of cotton wicks. And the case of fire alarm was checked. Result: The IoT multi-fire detector combined smoke and CO rung the alarm at the fire test of cotton wicks, did not ring the alarm at the smoke generator test. In comparison, the IoT multi-fire detector combined smoke and heat did not ring the alarm both at the smoke generator test and the fire test of cotton wicks. Conclusion: The IoT multi-fire detector combined smoke and CO detected the only smoke including the carbon monoxide and the IoT multi-fire detector combined smoke and heat did not ring the alarm for lack of heat. As a result, when the developed IoT multi-fire detector was detected the signal more than the set point, the fire alarm was sounded through cotton wicks fire test and smoke generator.

Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply (레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석)

  • Ryu, Ji-Ho;Cho, Chong-Hyeon;Chong, Min-Kil;Park, Sung-Jin;Kang, Kwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.

Design of Integrated Control System for Combustion Type CO2 Generator with Solar Radiation Sensitiveness and Irrigation Supply (일사량 감응 및 관수공급이 가능한 연소형 CO2 발생기 통합 제어시스템의 설계)

  • Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.3
    • /
    • pp.617-622
    • /
    • 2018
  • Simultaneous control of blowers and heat exchangers affecting the air sealing and flow conditions inside the green house is essential to the management of $CO_2$ concentration. Currently, the demand for automation systems and integrated control is steadily increasing according to increasing of farm areas per person due to the reduction of agricultural population. This paper proposes the integrated control system that can control simultaneously the existing devices such as measurement switching devices which are important variables in the supply of $CO_2$, $CO_2$ generator fuel and combustion air mixture ratio(air-to-fuel ratio), and $CO_2$ supply control under internal and external conditions.