As a part of basic studies on monitoring and saturation estimation of carbon dioxide ($CO_2$) storage using resistivity survey, laboratory experiment has been conducted to measure the change of the electrical resistivity through repeated experiments of supercritical $CO_2$ and brine water injection into homogeneous and heterogeneous sandstones. The $CO_2$ saturation is estimated by using resistivity index based on the resistivity measurements. The experimental results of two types of sandstones show that the effect of pore structure in the rock and the effect of contained clay minerals in the rock can be affected to calculate the $CO_2$ saturation. The result can be useful to evaluate the $CO_2$ saturation based on resistivity survey at the site where $CO_2 sequestrates.
In order to evaluate the elimination of CO through the lung comparing with the decrease of CO content in the blood, authors had induced acute CO poisoning on 9 dogs. Arterial CO-Hb saturation, CO concentration, %, in expired gas and eliminated CO amount through the lung were measured at 1,5,10,30,60, and 120 minutes after acute CO poisoning in 6 dogs breathing room air and 3 dogs breathing room air and oxygen alternately. Results obtained are summarized as follows. In room air breathing group, arterial CO-Hb saturation averaged 50.8% , and 53.67 ml of CO was blew off through the lung during 120 minutes and in alternately air and oBygen breathing group, the arterial CO-Hb saturation averaged 65.6% and 95.6 ml of CO was blew off through the lung. The amount of CO eliminated in expired gas for 120 minute was much less than the amount of decreased CO in arterial blood which was calculated with the decreased CO-Hb content in the estimated circulating blood volume. Such difference between the amount of eliminated CO in expired gas and the decreased CO in blood might be attributed to the oxidation of CO to $CO_2$ in the tissues. Concentration of CO in expired gas was markedly increased and the rate of decrease in arterial CO-Hb saturation is enhanced by oxygen breathing. In early period of recovery from acute CO poisoning, neither the CO concentration in expired gas, nor, the rate of CO elimination (unlit 2 minutes after CO poisoning) showed close correlation with the blood CO-Hb saturation level. The reason seemed to be due to irregularly depressed or unevenly stimulated respiration which were induced by acute CO poisoning.
This study was carried out to know the effect of light intensity, temperature and $CO_2$ concentration on photosynthesis and transpiration in yacon(Polymnia sonchifolia Poepp.& Endl.). Light compensation point was ${58\;{\mu}mol\;m^{-2}\;s^{-1}}$and light saturation point was ${1708\;{\mu}mol\;m^{-2}\;s^{-1}}$. Transpiration rate was increased to about 4 mmol${m^{-2}\;s^{-1}}$ with increasing of light intensity to ${2193\;{\mu}mol\;m^{-2}\;s^{-1}}$. The optimum temperature for photosynthesis was ${24^{\circ}C}$ in air. Photosynthesis was gradually reduced as transpiration rate increased from 4 to 8 mmol ${m^{-2}\;s^{-1}}$ in different air temperature. $CO_2$ compensation point was 63 vpm and $CO_2$ saturation point was 1155 vpm and light saturation point was enhanced with increasing of $CO_2$ concentration from 350 vpm to 1300 vpm.
Journal of the Korean Institute of Electrical and Electronic Material Engineers
/
v.17
no.1
/
pp.46-51
/
2004
The cause for the variation of the initial permeability according to the Co substitution of Ni-Zn ferrite used in the LC resonance filter for the power line communication is studied. The initial permeability decreases as the quantity of Co diminishes, and the saturation magnetization increases as the quantity increases. Because the sintering density and the microstructure of ferrite show little change, the variation of the initial permeability can't be explained by the density, microstructure nor the saturation magnetization factor. The magnetocrystalline anisotropy increases, similar with the saturation magnetization, as the quantity of Co increases. The increase of magnetocrystalline anisotropy value makes the domain wall energy grow, which leads to the decrease of the initial permeability, because there's linear law between the magnetocrystalline anisotropy and the domain wall energy. The resonance frequency to Co substitution moved to high frequency band, due to the close relationship with domain wall energy, Initial permeability decreaed a little with an increase of Co contents, but resonace frequency moved to high frequency band. as a result of that, when Co was added 0.05 mol, initial permeability and resonace frequency was 75 and 25 MHz respectively.
As part of basic studies of monitoring carbon dioxide ($CO_2$) storage using electrical and seismic surveys, laboratory experiments have been conducted to measure resistivity and P-wave velocity changes due to the injection of $CO_2$ into water-saturated sandstone. The rock sample used is a cylinder of Berea sandstone. $CO_2$ was injected under supercritical conditions (10 MPa, $40^{\circ}C$). The experimental results show that resistivity increases monotonously throughout the injection period, while P-wave velocity and amplitude decrease drastically due to the supercritical $CO_2$ injection. A reconstructed P-wave velocity tomogram clearly images $CO_2$ migration in the sandstone sample. Both resistivity and seismic velocity are useful for monitoring $CO_2$ behaviour. P-wave velocity, however, is less sensitive than resistivity when the $CO_2$ saturation is greater than ~20%. The result indicates that the saturation estimation from resistivity can effectively complement the difficulty of $CO_2$ saturation estimations from seismic velocity variations. By combining resistivity and seismic velocity we were able to estimate $CO_2$ saturation distribution and the injected $CO_2$ behaviour in our sample.
Transactions of the Korean Society of Mechanical Engineers B
/
v.38
no.2
/
pp.165-172
/
2014
Experiments were conducted to identify basic characteristics of $CO_2$ capture using a spray tower with a single nozzle. Results were evaluated in terms of $CO_2$ saturation which is the main determining factor of regeneration energy, and capture efficiency under various operating conditions. Changes in the capture efficiency under various conditions are well expressed as a monotone increasing function of the relative solvent $(NH_3):CO_2$ flow rate. Although changes in $CO_2$ saturation are also well described as a function of the $NH_3/CO_2$ flow rate ratio, these are expressed as a monotone decreasing function, in contrast with the increasing function of $CO_2$ efficiency. In recent research on the relationship between $CO_2$ saturation and capture efficiency, $CO_2$ saturation was found to decrease when capture efficiency increased. In conclusion, the results show that the amount of solvent used for achieving high capture efficiencies is excessive, as is the amount of regeneration energy needed.
The magnetoresistance (MR) and the saturation field behavior of the CoFe-Ag nano granular films as a function of the ferromagnetic underlayer and overlayer materials were investigated. The maximum MR ratio of 25.7 % and the saturation field of 2.1 kOe in the as-deposited 3000 $\AA$$(Co_{92}Fe_8)_{31}Ag_{69}$ single alloy films at room temperature were obtained. The MR ratio and the saturation field of the 100 $\AA$ alloy film were 1.2 % and 5.2 kOe, respectively. Those of the sandwiched alloy films of 200 $\AA$ thick with the Fe under and overlayer of 100 $\AA$ were 11 % and 1.8 kOe respectively. The reduction of saturation field in the sandwiched alloy films is due to the exchange coupling between the ferromagnetic layers and the alloy layer. Among the Fe and FeNi, the more effective materials to reduce the saturation field of the sandwiched alloy films was Fe.
This study was carried out to know the effect of light intensity, temperature and $CO_2$ concentration on photosynthesis and transpiration in Hovenia dulcis Thunb. Light compensation point was $2.4\;{\mu}mol\;m^{-2}\;s^{-1}$ and light saturation point was $1033\;{\mu}mol\;m^{-2}\;s^{-1}$. The optimum temperature for photosynthesis was $25^{\circ}C$ at $1000\;{\mu}mol\;m^{-2}\;s^{-1}$ light intensity. $CO_2$ compensation point was 67 vpm and $CO_2$ saturation point was 707 vpm. Transpiration rate was increased to about $2\;mmol\;m^{-2}\;s^{-1}$ with increasing of light intensity to $1750\;{\mu}mol\;m^{-2}\;s^{-1}$ and to above $4\;mmol\;m^{-2}\;s^{-1}$ with increasing of temperature from $18^{\circ}C$ to $36^{\circ}C$. however It was gradually reduced as $CO_2$ concentration increased from 21 vpm to 800 vpm.
The magnetoresistance and the saturation field behavior of the Co-Ag nano granular films as a function of the composition and the ferromagnetic underlayer and overlayermaterials were investigated. The maximum magnetoresistance of 23% and the saturation field of 2.3 kOe at room temperature were obtained in the as-deposited 3000$\AA$$Co_{30}Ag_{70}$ single alloy films. The magnetoresistance and the saturation field of 100$\AA$$Co_{30}Ag-{70}$ alloy film were 3.65 % and 3.0 kOe respectively. Those of the sandwiched films with 200$\AA$ Fe were 3.3 % and 1.23 kOe respectively. The saturation field of the sandwiched alloy films could be reduced by the exchange coupling between the ferromagnetic layers and the alloy layer. The effective depth of the exchange coupling was approximately 150$\AA$ in each Fe layer. Among the Fe, Co, and FeNi, the most effective materials to reduce the saturation field of the sandwiched alloy films was Fe.
The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.