• 제목/요약/키워드: $COD_{Cr}$

검색결과 332건 처리시간 0.027초

다단 생물반응기에 의한 질소제거 (Nitrogen Removal from Wastewater by a Multi-stage Bio-reactor)

  • 최규철;정일현
    • 환경위생공학
    • /
    • 제13권1호
    • /
    • pp.91-103
    • /
    • 1998
  • Design data for COD and nitrogen removal from wastewater were collected from Pilot's Multi-stage Bio-reactor. Hyraulic conditions and pollutant loadings were varied in order to optimize the biological and operational parameters. Pilot's experimental results summarize as followings. 1. T-N removal efficiency in the organic volumetric loading 0.2 kgCOD/m$^{3}$·d was obtained as maxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.. 2. Nitrification reaction was shown as maxium in the SCOD$_{cr}$/NH$^{+}$-N ratio of 6.5 and in more ratio than this it was decreased. Denitrification rate was the maxium as 85% in more than 7.5 of SCOD$_{cr}$/NO$_{x}$-N ratio and in the ratio over this ratio it becomes constant. 3. By utilizing an applied new model of Stover-Kincannon from Monod's kinetic model, concentration of T-N in the effluent according to flow quanity in the influent was estimated as 8.74 and -67.5 respectively. The formula for estimating T-N concentration of effluent was obtained like this: N$_e$=N$_0$(1- $\frac{8.74}{(QN$_0$/A)-67.05}$)

  • PDF

유동층 생물반응기의 구조변화에 따른 하수처리 (Sewage Disposal by Different Structure of Fluidized Bed Biofilm Reactor)

  • 박종만;이재용;김철경;고창웅;김남기
    • 상하수도학회지
    • /
    • 제18권2호
    • /
    • pp.181-187
    • /
    • 2004
  • The purpose of this study is to investigate the biofilm reactors capable of doing high efficiency treatment. Vertical fluidized bed biofilm reactor(VFBBR) and spiral fluidized bed biofilm reactor(SFBBR) was used for their performence in biodegradation of artificial sewage. The factors influencing the efficiency of those reactors were compared with difference of physical condition. They had same size but different structure to gain access of its unique characteristics. When recycle solution with flow rate of 22 mL/min and artificial sewage with flow rate of 2~10 mL/min were fed into two reactors in aerobic state, the average $COD_{cr}$, removal rate for biodegradation of SFBBR was greater than VFBBR. After reactor feed sewage was constantly maintained as flow rate of 4 mL/min and the recycle solution were changed to 10~32 mL/min respectively, the average $COD_{cr}$ removal rate of artificial sewage in SFBBR was greater than VFBBR. In this experiment for addition of support media into two reactors SFBBR was 4.1% excellent than VFBBR. Above all, SFBBR excelled VFBBR in boidegradation of organic matter in sewage.

인공습지 형태에 따른 비점오염저감효율 분석 (Analysis for Removal Efficiency of Non-point Pollution Sources by Constructed Wetlands)

  • 이상혁;김이형;조혜진
    • Ecology and Resilient Infrastructure
    • /
    • 제1권2호
    • /
    • pp.102-108
    • /
    • 2014
  • 비점오염저감시설에 대한 연구는 활발히 진행되고 있으나, 도로에 자연형 비점오염저감시설 설치시 비점오염저감효율에 대한 연구는 없는 실정이다. 본 연구에서는 도로에 설치된 여러 종류의 인공습지에 대한 비점오염 저감효율을 모니터링과 유량가중평균농도법을 이용하여 분석하였다. 분석결과, 인공습지는 일반적인 오염물질인 TSS, COD, BOD, TN, TP에 대한 저감효율은 비교적 우수한 것으로 나타났으며 중금속인 Cr, Zn, Pb의 제거효율은 낮거나 거의 없는 것으로 나타났다.

고급산화공정을 이용한 염료폐수의 처리기술 연구 (A Study on the Dye Wastewater Treatment by Advanced Oxidation Process)

  • 강태희;오병수;박세준;강민구;김종성;강준원
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.267-273
    • /
    • 2005
  • Dye wastewater generally contains strong color and non-biodegradable materials. Therefore, the conventional wastewater treatment plant can hardly meet the regulation of wastewater effluent water. In this study, a pilot plant of the conventional process followed by advanced oxidation process (AOP), was set up to treat the dying wastewater. The treatment efficiencies on the various candidate processes, such as ozone alone, UV alone, ozone/UV, $ozone/H_2O_2$, $H_2O_2/UV$ and $ozone/UV/H_2O_2$, were investigated in the various ozone and $H_2O_2$ doses. As the results, the $ozone/H_2O_2$ process, among the tested processes, showed the highest efficiency for removing color and $COD_{Cr}$. For color removal, the ozone alone process was enough without combining UV or $H_2O_2$. No significantly enhanced efficiency for removing color and $COD_{Cr}$ by UV irradiation was observed because of the very low transmittance of UV light in dye wastewater.

고정화담체를 이용한 염색폐수의 난분해성 유기물질 처리 (Treatment of Refractory Organics in Dyeing Wastewater by Using Cell Immobilized Pellets)

  • 한덕규;배우근;조영진;원호식;이용우
    • 대한환경공학회지
    • /
    • 제27권9호
    • /
    • pp.917-922
    • /
    • 2005
  • 섬유 염색폐수는 PVA, 유기정련제, 각종 염료 등이 함유되어 있어 처리가 매우 어려운 난분해성 유기폐수로 분류되어 있다. 본 연구에서는 생물학적 처리방법으로 염색폐수의 난분해성 유기물질을 효과적으로 처리할 수 있는 방안으로 활성슬러지를 PEG(Polyethylene glycol)에 포괄고정화한 담체를 고정상 반응기를 이용한 공정에 적용시켜 난분해성 유기물질의 처리효율을 평가하고 적정 운전인자를 검토하였다. 별도로 적응과정을 거치지 않은 활성슬러지를 고정화한 담체를 고정상 반응기에 충전하여 호기성 상태에서 연속식으로 운전하였다. 이때 유입수는 $SCODE_{Cr}$ 약 330 mg/L, $SBOD_5$ 20 mg/L 이하의 생물학적 1차 처리수를 사용하였다. 체류시간의 변화에 따른 각 반응기의 난분해성 유기물질 제거효율을 비교한 결과 EBCT 6 hr을 제외하고는 모두 50% 이상의 유기물($CODE_{Cr}$) 제거효율을 보였고 $COD_{Mn}$의 경우 배출허용기준치 90 mg/L보다 평균 18 mg/L 이상 낮았다. EBCT $6{\sim}24\;hr$ 결과들을 비교한 결과 EBCT 8 hr이 유기물 제거효율과 배출허용기준을 고려할 때 경제적이고 안정된 효율을 얻을 수 있는 적정 체류시간으로 나타났다. 또한 반응기에 충분한 DO를 공급하기 위하여는 주입공기 선속도를 $7\;m^3/m^2{\cdot}hr$ 이상으로 해 주어야 하는 것으로 나타났다. 또한 담체내부 미생물을 동정한 결과 PAH, PVA, Phenol 등 난분해성 물질을 분해하는 균주가 성장하고 있었다. 한편, 고정화담체를 131일에 걸쳐 관찰한 결과 압축강도와 담체내부로의 물질확산에 큰 변화가 없는 것으로 나타났다. 포괄고정화 담체를 이용한 염색폐수처리에서 고정상 반응기는 기존 활성슬러지 공정의 후처리로서 적용 가능할 것으로 판단되어진다.

수질오염총량관리제에서 난분해성 유기물질 관리 필요성 및 개선방안 (Necessity of Refractory Organic Matters Management in Total Maximum Daily Loads (TMDLs))

  • 박재홍;박배경;이재관;류덕희
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.393-399
    • /
    • 2013
  • To control organic matters, it needs to manage not only biodegradable organic matters but also refractory organic matters. Refractory organic matters from municipal wastewater, industrial wastewater, non-point sources and etc., have been continuously discharged to the near watersheds. It is estimated that the refractory organic matter ratios are continuously increased in waterbody. In watersheds of the Total Maximum Daily Loads (TMDLs), it was investigated that COD/BOD ratios increased in many unit watersheds of the 4 major river basins. The portions COD/BOD ratios increased were found to be a 97% of Geum River unit watersheds, a 81% of Yeongsan/Seumjin River unit watersheds, a 78% of Nakdong River unit watersheds, a 70% of Han River unit watersheds, respectively. Therefore, it has become important for establishment of effective management strategies to control refractory organic matter in watersheds of the Total Maximum Daily Loads (TMDLs). In order to properly manage organic matters including refractory organic matters, the present organic indicator (BOD) has to be converted to TOC (or COD). Compared to COD and BOD, TOC, as a organic matter indicator, is evaluated more appropriate.

목포-해남 연안 조간대 퇴적물중 유기물 및 미량금속 분포 특성 (Distributions of Organic Matter and Trace Metals in Intertidal Surface Sediment from the Mokpo-Haenam Coast)

  • 황동운;김평중;정래홍;윤상필
    • 한국수산과학회지
    • /
    • 제46권4호
    • /
    • pp.454-466
    • /
    • 2013
  • To evaluate the organic matter and trace metal pollution in intertidal sediment of the coastal zone, various geochemical parameters (grain size, ignition loss [IL], chemical oxygen demand [COD], acid volatile sulfide [AVS], and metals [Al, Fe, Cu, Pb, Zn, Cd, Cr, Mn, Hg, and As]) were measured for the intertidal surface sediment of the mainland and islands between Mokpo and Haenam in the southwestern coast of Korea. The surface sediments consist mainly of finer sediments, such as mud and silt. The concentrations of IL, COD, and trace metals in intertidal sediment were relatively high in the shoreline of the mainland than in that of islands and those in some stations exceeded the sediment quality guidelines (SQGs). Moreover, the concentrations of IL, COD, and trace metals (except As) in sediment showed relatively good positive correlations with mean grain size, indicating that the concentrations of organic matter and trace metals in intertidal sediment of the study region are dependent on grain size of sediment. Pollution evaluation for trace metals using geochemical assessment techniques, such as enrichment factor, geoaccumulation index, and SQGs, suggested that the intertidal sediments in the study region show light pollution with Cr and moderate pollution with As. More extensive interdisciplinary studies are required to determine the potential causes of As pollution in intertidal sediment.

분광특성을 이용한 하·폐수시료 내 난분해성 유기물 농도 및 분포 예측 (Predictation of the Concentrations and Distributions of Refractory Organic Matters in Wastewater using Spectroscopic Characteristics)

  • 이보미;박민혜;이태환;허진;양희정
    • 한국물환경학회지
    • /
    • 제25권4호
    • /
    • pp.560-567
    • /
    • 2009
  • Treated or untreated wastewater may be a major source of refractory organic matters (R-OM) in drinking water sources. For this study, spectroscopic characteristics of wastewater OM were investigated using the samples from 20 wastewater treatment plants, which are located at the upstream of the lake Paldang, to suggest a estimate index for R-OM in wastewater. R-OM was quantified by measuring total organic carbon (TOC) concentration of the wastewater samples remaining after 28-day dark incubation. Among the traditional OM indices such as chemical oxygen demand (COD) and initial TOC, CODMn showed the lowest correlation coefficients with R-TOC of the samples. The ratios of carbonaceous biochemical oxygen demand (CBOD) to $COD_{Cr}$ had a better correlation with the percent distribution of R-OM than $BOD/COD_{Cr}$ ratios. terrestrial humic-like fluorescence (THLF) exhibited the highest correlation coefficient with R-TOC among the indices obtained from the synchronous fluorescence spectra of the samples. Milori index, one of the humification indices, showed a good correlation with the percent distribution of wastewater. This study demonstrated that fluorescence properties might be a better indices to estimate the concentrations and the distributions of wastewater OM compared to the specific UV absorbance (SUVA) values. Some useful formulas based on OM spectroscopic characteristics were finally suggested to predict R-OM in wastewater.

강우유출수 처리목적 인공습지의 강우시 오염물질 저감특성에 관한 연구 (Reduction Efficiency of the Stormwater Wetland from Animal Feeding-Lot)

  • 박기수;우사평;김영철
    • 한국습지학회지
    • /
    • 제15권1호
    • /
    • pp.79-90
    • /
    • 2013
  • 가축사육지역으로부터 발생되는 강우유출수 처리를 위해 건설된 인공습지에 대해 2010년 5월부터 2011년 11월까지 수행한 20회의 강우시 모니터링을 통하여 얻은 자료를 분석한 결과 강우시 저감효율은 TSS 88%, BOD 54%, $COD_{Mn}$ 35%, $COD_{Cr}$ 70%, TN 31%, TP 64%이었다. 이론적으로 강우계급의 증가(강우유출량 증가)는 습지의 수리학적 교환비율을 증가시키기 때문에 TSS 저감효율은 감소해야하는데 교환비율이 1에 접근하였을 때 대략 55%의 효율을 달성하였다. 또한 연속적인 강우활동, 개별적인 강우사상의 대소, 강도, 선행건기 일수 등 습지에서는 실험자가 제어할 수 없는 수많은 자연변수들이 복합적으로 작용하기 때문에 처리효율의 변동이 매우 컸다. 효율에 가장 큰 영향을 미친 요인으로는 수리학적 요인과 함께 조류증식이 성능 불확실성에 크게 기여하였다.

전북지역 농업용 하천유역의 수질과 부하량 특성 (Assessment of Water Quality and Pollutant Loads on Agricultural Watershed in Jeonbuk Province)

  • 엄미정;문영훈;안병구;신용규
    • 한국환경농학회지
    • /
    • 제27권2호
    • /
    • pp.111-119
    • /
    • 2008
  • 전북도내에서 농업용수원으로 사용되고 있는 소규모 하천들의 수질 및 오염부하량 조사를 통해 효율적인 수질개선을 위한 기초자료를 얻고자 본 시험을 수행하였다. 24개 하천의 수질은 EC가 $0.07{\sim}0.52$ dS/m, BOD가 $0.1{\sim}5.0$ mg/L, $COD_{Cr}$$0.6{\sim}17.7$ mg/L 등 이었으며, 범위는 다양하였으나 연도에 따른 평균값은 큰 차이를 보이지 않았다. 또한 ${SO_4}^{2-}$$5.7{\sim}52.7$ mg/L, $Cl^-$함량은 $0.9{\sim}57.5$ mg/L, $Na^+$함량은 $2.5{\sim}48.9$ mg/L의 범위를 보여 관개용수 수질로는 양호한 상태였다. 조사하천 대부분의T-N 함량은 5.0 mg/L 이하, T-P함량은 0.10 mg/L이하였으나 일부 하천에서 5.0 mg/L 이상의 질소를 함유하고 있는 경우가 있어 관개수질을 고려한 합리적인 시비가 필요한 것으로 나타났다. 강우기의 EC, $Ca^{2+},\;Mg^{2+},\;K^+$$Na^+$ 등의 함량은 감소하였지만, BOD, $COD_{Cr},\;COD_{Mn}$, T-N 및 T-P의 농도는 뚜렷한 차이를 보이지 않았으며, 높은 농도의 SS가 하천 유량의 증가와 함께 유출되고 있어 강우기의 지표면 유출이 수계에 영향을 주는 것으로 나타났다. 조사하천의 오염부하량은 BOD가 $9.6{\sim}757.9$ kg/day, T-N이 $51.2{\sim}1418.5$ kg/day, T-P가 $0.3{\sim}44.7$ kg/day로 유역 및 성분에 따라 많은 차이를 보이고 있었다. 갈수기에 비하여 강우기에 BOD는 $3.0{\sim}4.4$배, T-N는 $3.0{\sim}4.0$배, T-P는 $4.1{\sim}5.6$배의 부하량 증가를 보여 강우기에 주변 유역에서의 유기물을 비롯한 각종 영양염류의 유출이 많아지고 있었다. 논 면적비율이 30%이상인 하천유역(A그룹)이 30%이하인 하천(B그룹)유역이 비하여 영농기였던 7월의 강우기에 유량과 영양물질의 유달부하량이 상대적으로 적게 나타났으며, 갈수기 대비 강우기의 부하량 증가도 B그룹에서 유량이 5.7배 증가한 것에 비교하여 A그룹의 유량 증가는 2.3배로 적게 나타났다. BOD, T-N, T-P의 부하량과 유량과의 회귀식 결정계수($R^2$)는 BOD가 $0.8025^{**}$, T-N이 $0.9229^{**}$, T-P가 $0.7612^{**}$으로 유량과 T-N 부하량과의 상관이 가장 높게 나타났다.