• 제목/요약/키워드: $AgSO_4$

검색결과 224건 처리시간 0.028초

가공의치(架工義齒) 납착부(蠟着部)의 강도(强度)와 내부구조(內部構造)에 관(關)한 실험적(實驗的) 연구(硏究) (An experimental study of the strength and internal structure of solder joint of fixed partial denture)

  • 박상남;계기성
    • 대한치과보철학회지
    • /
    • 제23권1호
    • /
    • pp.39-59
    • /
    • 1985
  • The purpose of this study was to investigate how gap distances of 0.13mm, 0.15mm, 0.20mm, and 0.30mm affects solder joint strength from gold alloys and nickel-chromium base alloys and to examine the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys. The tensile test specimens were prepared in the split stainless steel mold with a half dumbbell shape 2.5mm in diameter and l2mm in length. 6 pairs of specimens of each gap distance group of gold alloys and nickel-chromium base alloys were made and 48 pairs of all specimens were soldered with solder gold of 666 fineness. All soldered specimens were machined to a uniform diameter and then a tensile load was applied at a cross-head speed of 0.10mm/min using Instron Universal Testing Machine, Model 1115. The fractured specimens at solder gold of solder joint fracture with each gap distance of 0.13mm, 0.15mm, 0.20mm, and 0.30mm were examined under the Scanning Electron Microscope, JSM-35c and the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys was analyzed by Electron Probe Micro Analyzer. The results of this study were obtained as follows: 1. In case of soldering of gold alloys, the tensile strength between gold alloys showed $37.33{\pm}2.52kg/mm^2$ at 0.13, $39.14{\pm}3.35kg/mm^2$ at 0.15mm, $43.76{\pm}2.97kg/mm^2$ at 0.20mm, and $49.18{\pm}4.60kg/mm^2$ at 0.30mm. There was statistically significant difference at each gap distance, and so the greater increase of gap distance showed the greater tensile strength. 2. In case of soldering of nickel-chromium base alloys, the tensile strength between nickel-chromium base alloys showed $34.84{\pm}4.26kg/mm^2$ at 0.13mm, $37.25{\pm}2.49kg/mm^2$ at 0.15mm, $42.91{\pm}4.32kg/mm^2$ at 0.20mm, and $46.93{\pm}4.21kg/mm^2$ at 0.30mm. There was not statistically significant difference only between 0.13mm and 0.15mm and bet ween 0.20 mm and 0.30mm, but generally the greater increase of gap distance showed the greater tensile strength. 3. The greater increase of gap distance shoed less porosities in solder gold at solder joint fracture. 4. In solder gold Au, Cu, Ag, Zn, and Sn were composed and Au and Cu were mostly distributed uniformly. 5. In solder joints of solder gold and gold alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Au, Cu, Ag, Pt, and Pd were composed in gold alloys. Au and Cu of solder gold and gold alloys were mostly distributed uniformly and the diffusion of other elements except Pt and Pd around the solder joint was not almost found. In solder joints of solder gold and nickel-chromium base alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Ni, Cr, and Al were composed in nickel-chromium base alloys. Au and Cu of solder gold and Ni and Cr of nickel-chromium base alloys were mostly distributed uniformly and the diffusion of other elements except Cr around the solder joint was not almost found.

  • PDF

핵의학 검체검사 내부정도관리 허용범위 설정에 관한 고찰 (A Study on the Establishment of Acceptable Range for Internal Quality Control of Radioimmunoassay)

  • 이영지;이소영;이선호
    • 핵의학기술
    • /
    • 제26권2호
    • /
    • pp.43-47
    • /
    • 2022
  • 핵의학 검체검사는 검사 결과의 품질 보증을 위해 내부정도관리 시스템을 체계화하여 질 관리를 시행하고 있다. 본 연구는 검사실 자체적인 허용 범위의 설정 시 참고가 될 수 있도록 여러 기관의 종목별 내부정도관리 및 외부정도관리의 변동계수 평균을 산출하여 종목별 질 관리 현황을 제공함으로써 핵의학 검체검사 결과의 품질 보증에 기여하고 체계적인 질 관리를 수행하고자 한다. 2020년 10월에서 2021년 12월까지 각 기관에서 시행한 42종목에 대한 내부정도관리 변동계수의 평균 및 10.0% 이상 이탈률을 구하였다. CV% 성적에 따라 상위 그룹(5.0% 이하), 중위 그룹(5.0~10.0%), 하위 그룹(10.0% 이상)으로 구분하여 비교하였고, 10.0% 이상 이탈률은 5개 이상 기관의 종목에 대해서 종양 표지자, 갑상선 호르몬, 기타 호르몬으로 분류하여 비교하였다. 2021년 1분기에서 4분기까지 28종목에 대해 외부정도관리 결과의 전체 평균 및 표준편차로 변동계수의 평균을 구하였다. 또한 2021년 상반기, 하반기 13종목에 대해 기관 간 숙련도 결과의 전체 평균 및 표준편차로 변동계수의 평균을 구하였다. 종목별로 내부정도관리 및 외부정도관리의 변동계수 평균을 비교하여 질 관리가 잘 이루어지는 종목과 관리에 주의가 필요한 종목을 비교 분석하였다. 6개 기관의 42종목에 대해 내부정도관리 변동계수의 평균을 산출한 결과 상위 그룹에 속하는 종목(5.0% 이하)은 ferritin, HGH, SHBG, 25-OH-VitD이며, 하위 그룹(10.0% 이상)은 cortisol, ATA, AMA, renin, estradiol이었다. 5개 이상 기관의 종양 표지자 8종목에 대해 변동계수의 10.0% 이상 이탈률은 CA-125와 CA-19-9가 우수한 성적을 나타내었으나, SCC-Ag와 CA-15-3 검사는 관리에 주의가 필요한 종목에 속했다. 갑상선 호르몬 7종목에 대해 변동계수의 10.0% 이상 이탈률을 비교한 결과 free T4와 T3 검사는 우수하였지만 AMA와 ATA는 관리에 주의가 필요해 보였다. 기타 호르몬 11종목에 대해 변동계수의 10.0% 이상 이탈률을 비교하였을 때 IGF-1, FSH, prolactin은 우수한 성적을 나타내었지만, estradiol, testosterone, cortisol은 관리에 주의가 필요한 종목에 속했다. 28종목에 대해 외부정도관리를 참여하는 전체 기관에 대한 변동계수 평균을 산출한 결과 상위 그룹에 속하는 종목(10.0% 이하)은 HGH, SCC-Ag이었으며, 하위 그룹(30.0% 이상)은 ATA, estradiol, TSI, thyroglobulin이었다. 6개 기관의 42종목에 대해 평가한 결과 변동계수가 3.7~12.2%로 하위 그룹과 상위 그룹이 3.3배의 차이를 보였다. 변동계수의 값이 높은 cortisol, ATA, AMA, renin, estradiol 검사들은 정밀도를 향상시키기 위한 개선 활동들이 지속적으로 이루어져야 할 것이다. 또한 HBs-Ab를 제외한 41종목에 대해 내부정도관리 및 외부정도관리, 기관 간 숙련도 참여기관의 전체 CV% 평균을 산출하여 비교한 결과 ATA, AMA, renin, estradiol 검사는 높은 허용범위 설정을 권장한다. 설정된 허용범위를 기준으로 체계적인 질 관리를 수행한다면 핵의학 검체검사 결과의 정확도 및 신뢰도를 향상시킬 수 있을 것으로 사료된다.

북창광상의 유체포유물 및 황안정동위원소 연구 (Fluid Inclusion and Sulfur Stable Isotope of Buckchang Deposit, Korea)

  • 정재일;김선영;나춘기;이인성
    • 자원환경지질
    • /
    • 제29권6호
    • /
    • pp.677-687
    • /
    • 1996
  • 북창광산은 옥천 변성대에 위치하며 $N20{\sim}30^{\circ}E$ 방향의 기존 열극구조를 충진하여 배태된 열극 충진 광상이다. 공생광물군에 대한 연구결과 광화작용은 크게 2 시기로 나눌 수 있다. I기 : 대부분 유화광물의 생성시기, II기 : 후기 유화광물, 엘렉트럼 및 함은광물의 생성시기. 북창광산에서 산출되는 은광물은 주로 휘은석이며 그외 소량으로 canfieldite, tetrahedrite 등이다. 또한 에렉트럼은 Au-Ag의 원자량비에서 거의 1 대 1에 가까운 매우 한정된 조성을 보였다. 북창광산의 생성온도, 염농도 및 압력은 유체포유물 및 유황동위원소를 이용하여 측정되었으며 다음과 같다. I기 : $174{\sim}250^{\circ}C$, 0.35~4.01 NaCl eq. wt%, 0.40~1.00 Kbar, II기 : $138{\sim}222^{\circ}C$, 1.9~8.4 NaCl eq. wt%, 0.22~0.53 Kbar로 나타난다. 초기 광화작용동안 산소분압 및 유황분압은 공생광물군의 상평형관계에 근거하여, 각각 $10^{-39.7}{\sim}10^{-44.7}atm.$ and $10^{-13.4}{\sim}10^{-18.1}atm.$으로 나타난다. 이와 같은 연구결과 북창광산은 Polymetallic epithermal type의 광상으로 생각된다.

  • PDF

pH-Dependent surface-enhanced resonance Raman scattering of yeast iso-1-cytochrome c adsorbed on silver nanoparticle surfaces under denaturing conditions at pH < 3

  • Lee, So-Yeong;Joo, Sang-Woo;Lee, Seong-Hoon;Lim, Man-Ho
    • BMB Reports
    • /
    • 제42권4호
    • /
    • pp.223-226
    • /
    • 2009
  • We measured the pH-induced spectral changes of yeast iso-1-cytochrome c on silver nanoparticle surfaces using surface-enhanced resonance Raman scattering (SERRS) at 457.9 nm. At a pH of ~3, the Met80 ligand in yeast iso-1-cytochrome c is assumed to dissociate, leading to a marked conformational change as evidenced by the vibrational spectral shifts. The Soret band at ~410 nm in the UV-Vis spectrum shifted to ~396 nm at pH~3, indicating a transition from a low spin state to a high spin state from a weak interaction with a water molecule. Thus, SERRS spectroscopy can measure the pH-induced denaturalization of cyt c adsorbed on metal nanoparticle surfaces at a lower concentration with a better sensitivity than ordinary resonance Raman spectroscopy.

생체내의 혈중이온농도 예측을 위한 마이크로 pH-ISFET프로브의 개발 (Development of a Micro pH-ISFET Probe for in vivo Measurements of the Ion Concentration in Blood)

  • 손병기;이종현;이광만
    • 대한전자공학회논문지
    • /
    • 제23권1호
    • /
    • pp.83-90
    • /
    • 1986
  • A micro pH-ISFET probe, which can be applied to the in vivo measurements of the hydrogen ion concentration in blood, has been developed, and a measuring system equiped with this probe also developed. The pH-ISFET has been fatricated by employing the techniques of integrated circuit fabrication. Two kinds of micro electrode formed around the sensing gate during the wafer process, and the other is a capillary type of Ag/AfCl/sat. KCI reduced in size. This capillary electrode has shown its good performance characteristics so far in the application with ISFET as well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and the capillary electrode were built together into a needle tip having 1 mm inner diameter. The chip size of a twin pH-ISFET is 0.8 mmx1.4 mm, the material of the sensing gate membrane is Si3N4, and the sensitivity of the developed probe is about 52mV/pH.

  • PDF

정상 성인에 있어서의 B형 간염 바이러스 감염에 관한 혈청역학적 연구 (Seroepidemiology of Hepatitis B Virus Infection in Healthy Korean Adults in Seoul)

  • 유근영;박병주;안윤옥
    • Journal of Preventive Medicine and Public Health
    • /
    • 제21권1호
    • /
    • pp.89-98
    • /
    • 1988
  • While there have been not a few reports on the seroepidemiological characteristics of hepatitis B virus (HBV) infection in Korea, most of them, however, have had several limitations; operational definition of HBV infection, validity of detection methods of HBV serologic markers, size of the study population, and confirmation of the vaccination history against HBV, etc. In order to avoid such limitations, authors randomly selected 1,495 healthy adults among the 217,511 insured (target population) of Korean Medical Insurance Corporation, living in seoul, and tested HBV serologic markers by RIA method and conducted direct interview to them. Although HBV serologic markers (HBsAg, anti-HBs and anti-HBc) of all the subjects were tested, 392(26.2%) of interview failure cases and 361 vaccinee were excluded from the actual population. Finally, the serologic markers tested of 742 nonvaccinee (study population) only were analysed for the seroepidemiologic observation of the natural infection of HBV. The seroepidemiological characteristics of HBV infection in Korea were as follows ; 1. Point prevalence of HBs antigenemia was 11.7(9.1{\sim}14.3)% in male, which was slightly higher than that of female, 9.5($3.7{\sim}15.3$)%. This level was one of the highest among those of Asian-Pacific countries. Decreasing tendency of HBsAg prevalence alter the age of 50 was observed, which seems to be due to selective attrition of HBV chronic carriers among the healthy adults and/or to the limited-lasting duration of the HBs antigenemia, in part. 2. Point prevalence of anti-HBc(78.8% in male,50.9% in female) was higher than that of anti-HBs(65.2% in male,46.6% in female), respectively. And both of them were higher in male than in female. Increasing tendency of the prevalence of both antibodies was observed by age, which seems to be largely due to recurrent infection in adults and to some cumulative effect, in part, of their relatively longer-lasting duration. 3. The level of HBV infection defined by positive for at least one of the 3 serologic markers of HBV by RIA method was 84.7($81.8{\sim}87.6$)% in male and 61.2($51.9{\sim}70.5$)% in female, which was also one of the highest among those of Asian-Pacific countries. The proportion of susceptible population to HBV infection among healthy adults was 15.3% in male and 38.8% in female. 4. The relative frequency of current or past infection and chronic carrier among HBV infected person was estimated. The currently or past infected was estimated 75.7% in male and 71.8% in female, and chronic carrier state, 13.8% in male and 14.1% in female. The analysis of the geometric mean of the antibody titer in anti-HBs positive sera indicated also to be compatible with the above findings, suggesting that active, even though inapparent, infection of HBV occur so frequently among healthy adults in Korea.

  • PDF

각종(各種) 간질환자(肝疾患者)에서 혈청 $Beta_2-microglobulin$ 치(値)의 임상적(臨床的) 의의(意義) (The Clinical Significance of Serum $Beta_2-microglobulin$ Levels in Patients with Various Liver Diseases)

  • 장석원;조태봉;최중호;김소연;조민구;이관전
    • 대한핵의학회지
    • /
    • 제19권2호
    • /
    • pp.81-86
    • /
    • 1985
  • To evaluate the significance of serum $beta_2-microglobulin$ in patients with various liver diseases, serum $\beta_2m$ levels were measured in 44 cases of normal controls, 32 cases of asymptomatic HBsAg carriers and 134 patients with various liver diseases, by radioimmunoassay using Phadebas $Beta_2-micro$ test kits. The following results were obtained: 1) The mean level of serum $\beta_2m$ was $1.39{\pm}0.25mg/l(Mean{\pm}S.D.)$ in normal controls ($1.39{\pm}0.23mg/l$ in 24 males, $1.38{\pm}0.27mg/l$ in 20 females). 2) The serum levels of $\beta_2m$ in patients with various liver diseases and asymptomatic HBsAg carriers were as follows; $1.40{\pm}0.27mg/l$ in asymptomatic HBsAg carriers, $2.42{\pm}0.37mg/l$ in 45 patients with acute viral hepatitis, $2.10{\pm}0.26mg/l$ in 46 patients with chronic persistent hepatitis, $2.60{\pm}0.34mg/l$ in 23 patients with chronic active hepatitis, and $2.60{\pm}0.49mg/l$ in 20 patients with liver cirrhosis. Serum $\beta_2m$ levels of each disease group were significantly higher than that of normal controls(p<0.001). 3) There was significant correlation between the levels of serum $\beta_2m$ and the degrees of lymphocytic infiltration in patients with chronic active hepatitis(p<0.001). 4) Significant correlations were observed between the levels of serum $beta_2-microglobulin$ and serum alanine aminotransferase(r=0.68, p<0.05) and bilirubin(r=0.63, p<0.05) in 15 patients with acute viral hepatitis. In conclusion, the serum $beta_2-microglobulin$ levels were increased in patients with various liver diseases, and it may serve as a new index of liver disease activity.

  • PDF

Polymerization of Hydrosilanes and Vinyl Monomers in the Presence of Transition Metal Complex

  • Kim, Myoung-Hee;Lee, Jun;Cha, Hyo Chang;Shin, Joong-Hyeok;Woo, Hee-Gweon
    • 통합자연과학논문집
    • /
    • 제2권1호
    • /
    • pp.18-23
    • /
    • 2009
  • This minireview provides the chosen examples of our recent discoveries in the polymerization of hydrosilanes, dihydrosilole, lactones, and vinyl derivatives using various catalysts. Hydrosilanes and lactones copolymerize to give poly(lactone-co-silane)s with $Cp_2MCl_2$/Red-Al (M = Ti, Zr, Hf) catalyst. Hydrosilanes (including dihydrosilole) reduce noble metal complexes (e.g., $AgNO_3$, $Ag_2SO_4$, $HAuCl_4$, $H_2PtCl_6$) to give nanoparticles along with silicon polymers such as polysilanes, polysilole, polysiloxanes (and silicas) depending on the reaction conditions. Interestingly, phenylsilane dehydrocoupled to polyphenylsilane in the inert nitrogen atmosphere while phenylsilane dehydrocoupled to silica in the ambient air atmosphere. $Cp_2M/CX_4$ (M = Fe, Co, Ni; X = Cl, Br, I) combination initiate the polymerization of vinyl monomers. In the photopolymerization of vinyl monomers using $Cp_2M/CCl_4$ (M = Fe, Co, Ni), the photopolymerization of MMA initiated by $Cp_2M/CCl_4$ (M = Fe, Co, Ni) shows while the polymerization yield decreases in the order $Cp_2Fe$ > $Cp_2Ni$ > $Cp_2Co$, the molecular weight decreases in the order $Cp_2Co$ > $Cp_2Ni$ > $Cp_2Fe$. For the photohomopolymerization and photocopolymerization of MA and AA, the similar trends were observed. The photopolymerizations are not living. Many exciting possibilities remain to be examined and some of them are demonstrated in the body of the minireview.

  • PDF

Near-Infrared Spectroscopy and Modeling of Luminous Blue Variables

  • 김현정;구본철;박용선
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.152.1-152.1
    • /
    • 2011
  • We report preliminary results of long-slit near-infrared (NIR) spectroscopy of Luminous Blue Variables (LBVs) with moderate resolution of R ~ 2400. We obtained Jshort (1.04-1.26 micron) and Ks (2.02-2.31 micron) band spectra of 4 LBVs and 3 LBV candidates in Southern hemisphere using IRIS2, infrared imager and spectrograph, mounted on the 4-m Anglo-Australian Telescope. All targets are fairly bright in NIR so that we can obtain high signal-to-noise ratio for clear line detection and modeling. They are also widely distributed in the HR diagram so that we can compare the spectral properties of LBVs in different temperature and luminosity ranges. Among them, we present the results of two well-known LBVs AG Car and HR Car. Their spectra show similar properties with hydrogen, He I, and metallic lines such as Fe II and Mg II, most of them in emission. We discuss, in particular, the He I 1.083 micron lines formed in stellar wind because these two LBVs show large variation in their He I line intensities, compared to previous studies. Since the He I 1.083 line is known to be anticorrelated with the photometric variation of LBVs, strong line intensities with P-Cygni profiles in both stars indicate that they are now near the visual minimum phase. We model the obtained spectra using non-LTE atmosphere code CMFGEN of Hillier (1998) to derive stellar parameters such as wind velocity and mass loss rate, and discuss the long-term variability of stellar parameters of these LBVs. deduced from our otometric solution.

  • PDF

원심 용융 성형공정으로 제조된 BSCCO 튜브의 전기적 특성 (Electronical Property of BSCCO Tube Fabricated by Centrifugal Melting Process)

  • 최정숙;오성룡;전병혁;김혜림;현옥배;김형섭;김찬중
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.267-267
    • /
    • 2006
  • 전력에 큰 손실을 초래하는 고장전류를 차단하기 위한 한류기(FCL) 소재로서 고온 초전도체인 BSCCO 2212가 사용된다. 고온에서 용융된 BSCCO 2212 분말은 원심성형법에 의해 한류기용 튜브로 제조되었다. BSCCO 튜브의 기계적 특성을 높이고 용융온도를 낮추기 위해 $SrSO_4$(10wt-%)를 첨가하였다. 용탕은 $1200^{\circ}C$에서 완전히 용융되어 금속 몰드로 주입되었고 원심성형에 사용되는 금속 몰드는 $550^{\circ}C$ 온도로 2시간 예열 후 1020 ~ 2520 RPM으로 회전시켰다. 원심력에 의해 성형된 BSCCO 튜브는 약 48시간 동안 로에서 서냉 후 금속 몰드로부터 분리하였다. 튜브의 용이한 분리를 위해 이형제로서 BSCCO 2212 powder를 사용하였고 임계전류측정을 고려하여 Ag tape 단자를 튜브 끝단에 부착하였다. BSCCO 제조 공정에 있어서 몰드의 예열온도, 용융온도, 몰드 회전속도 등의 변수를 조절하여 최적의 조건을 확립하였다. 제조한 BSCCO 튜브의 임계전류($I_c$)와 임계전류밀도($J_c$)는 77K에서 536A와 $205A/cm^2$ 이었다. 본 연구에서는 BSCCO 2212 튜브를 제조하는 공정조건 변화와 각 조건에서 제조된 BSCCO 2212 튜브의 전기적 특성 및 그에 따른 분석에 대해 기술하였다.

  • PDF