• Title/Summary/Keyword: $A_0$ Mode

Search Result 4,042, Processing Time 0.037 seconds

Experimental investigation of the photoneutron production out of the high-energy photon fields at linear accelerator (고에너지 방사선치료 시 치료변수에 따른 광중성자 선량 변화 연구)

  • Kim, Yeon Su;Yoon, In Ha;Bae, Sun Myeong;Kang, Tae Young;Baek, Geum Mun;Kim, Sung Hwan;Nam, Uk Won;Lee, Jae Jin;Park, Yeong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 2014
  • Purpose : Photoneutron dose in high-energy photon radiotherapy at linear accelerator increase the risk for secondary cancer. The purpose of this investigation is to evaluate the dose variation of photoneutron with different treatment method, flattening filter, dose rate and gantry angle in radiation therapy with high-energy photon beam ($E{\geq}8MeV$). Materials and Methods : TrueBeam $ST{\time}TM$(Ver1.5, Varian, USA) and Korea Tissue Equivalent Proportional Counter (KTEPC) were used to detect the photoneutron dose out of the high-energy photon field. Complex Patient plans using Eclipse planning system (Version 10.0, Varian, USA) was used to experiment with different treatment technique(IMRT, VMAT), condition of flattening filter and three different dose rate. Scattered photoneutron dose was measured at eight different gantry angles with open field (Field size : $5{\time}5cm$). Results : The mean values of the detected photoneutron dose from IMRT and VMAT were $449.7{\mu}Sv$, $2940.7{\mu}Sv$. The mean values of the detected photoneutron dose with Flattening Filter(FF) and Flattening Filter Free(FFF) were measured as $2940.7{\mu}Sv$, $232.0{\mu}Sv$. The mean values of the photoneutron dose for each test plan (case 1, case 2 and case 3) with FFF at the three different dose rate (400, 1200, 2400 MU/min) were $3242.5{\mu}Sv$, $3189.4{\mu}Sv$, $3191.2{\mu}Sv$ with case 1, $3493.2{\mu}Sv$, $3482.6{\mu}Sv$, $3477.2{\mu}Sv$ with case 2 and $4592.2{\mu}Sv$, $4580.0{\mu}Sv$, $4542.3{\mu}Sv$ with case 3, respectively. The mean values of the photoneutron dose at eight different gantry angles ($0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$, $225^{\circ}$, $270^{\circ}$, $315^{\circ}$) were measured as $3.2{\mu}Sv$, $4.3{\mu}Sv$, $5.3{\mu}Sv$, $11.3{\mu}Sv$, $14.7{\mu}Sv$, $11.2{\mu}Sv$, $3.7{\mu}Sv$, $3.0{\mu}Sv$ at 10MV and as $373.7{\mu}Sv$, $369.6{\mu}Sv$, $384.4{\mu}Sv$, $423.6{\mu}Sv$, $447.1{\mu}Sv$, $448.0{\mu}Sv$, $384.5{\mu}Sv$, $377.3{\mu}Sv$ at 15MV. Conclusion : As a result, it is possible to reduce photoneutron dose using FFF mode and VMAT method with TrueBeam $ST{\time}TM$. The risk for secondary cancer of the patients will be decreased with continuous evaluation of the photoneutron dose.

A Simple, Sensitive, and Specific HPLC Analysis of Tissue Polyamines using FNBT Derivatization: Its Application on the Study of Polyamine Metabolism in Regenerating Rat Liver (생체의 Polyamine-분석을 위하여 FNBT-유도체를 이용하는 간편하고 특이적이며 예민한 Isocratic RP-HPLC 분석법과 재생성 흰쥐-간의 Polyamine-대사의 변동에 관한연구)

  • Choi, Sang-Hyun;Kim, Hyung-Gun;Park, Hong-Ik;Chun, Boe-Gwun
    • The Korean Journal of Pharmacology
    • /
    • v.24 no.2
    • /
    • pp.233-240
    • /
    • 1988
  • A simple and selective isocratic HPLC method for the analysis of tissue polyamine contents is described and applied on the study of the changes of the hepatic polyamine contents after partial hepatectomy in male rats. The hepatic polyamines are extracted with 0.4 M perchloric acid containing 2 mM disodium EDTA, and then the extract is redissolved in 100 ul of 1 M sodium carbonate and incubated with 300 ul of FNBT-dimethylsulfoxide (1: 100) mixture. The N-2'-nitro-4'-trifluoromethylphenyl drivatives of polyamines are separated through a ERC-ODS column in an isocratic mode with an acetonitrile-water (80:20) mobile phase within 20 min. per a sample, while monitoring the effluent at 242 nm. This improved method which could detect subnanogram of each polyamines is highly specific and reproducible as evidenced by the application of it on the study of the changes of polyamine contents in the regenerating rat liver after partial hepatectomy.

  • PDF

Epidemiological Studies on Giardia Infection Associated with environmental Pollution (Giardia에 의한 환경오염(環境汚染)과 감염(感染)에 관한 역학적(疫學的) 연구(硏究))

  • Lee, Keun-Tae;Kim, Seok-Chan;Song, Jong-Sool;Chung, Pyung-Rim
    • Journal of agricultural medicine and community health
    • /
    • v.9 no.1
    • /
    • pp.56-66
    • /
    • 1984
  • Giardia lamblia is a pathogenic flagellate causing intestinal disorders such as diarrhea, abdominal pain and malabsorption of nutrients. Giardia is mainly infected by the ingestion of contaminated foods per os. Craun (1979) has recently reported that mass infection of this flagellate through the contaminated water supply systems is one of public health hazards. Also, so-called traveller's diarrhea is sometimes caused by Giardia infection (CDC, U.S.A., 1971). However, a few epidemiological studies figuring out the mode of infection or control measures of Giardia infection has been done so far in Korea. The present study was aimed to know the prevalence of Giardia infection in several Korean populations, detectability of this flagellate in water systems and the viability of the cysts against sewages and disinfectants applying to drinking water. In the present study, 388 stool specimens from orphanage children in Chun-joo, Chung-joo, On-yang and Chun-an areas and 538 stool specimens from inhabitants in Woo-do, In-chon, and Chun-joo were examined by formalin-ether concentration technique to detect out Giardia cysts. On the other hand, water samples from 14 sites of Han River and its tributaries were collected in May through July, 1984. Fifty liter of water sample in each sampling site was then filtered through water filtering system deviced by U.S. Environmental Proutection Agency and the sediments rinsed out from the thread rolls, a part of water filtering system, were examined to detect out the Giardia cysts. In order to observe the viability of Giardia cysts in the sewage samples, the cysts were treated in it at $4^{\circ}C$ or $25^{\circ}C$ for 7 through 28 days. For this purpose, the cysts were also exposed to various concentrations of disinfectants such as chlorine, iodine and ozone gas for proper time intervals. After treatment, the viability test of the Giardia cysts were carried out by method of Rice and Schaefer (1981) with minor modification. The results obtained in this study were as follows : 1) The detection rates of G lamblia cysts in the stool specimens were 18.3% in orphans and 4.3% in general examinees. 2) The prevalences of Giardia Infection were higher in the young age groups than in-adults. The highest positive rate was 18.4% in the age group less than 10. 3) Of 14 water specimens sampled from Han River system and its tributaries around the Seoul area, the Giardia cysts were detected from 4 samples, and no cyst was found in the water supply systems. 4) The cysts treated in the sewage survived for 28 days at $4^{\circ}C$ and for 13 days at $25^{\circ}C$. 5) The cysts were completely destroyed within 60 minutes by exposure to 8 mg/l of residual chlorine at 4g and within 30 minutes by exposure to the same concentration of chlorine at $25^{\circ}C$. 6) The cysts were all dead when exposed to 1 mg/1 of iodine for 60 minutes at $4^{\circ}C$ or $25^{\circ}C$. 7) The cysts were destroyed after 10 minute exposure in 0.15 mg to 0.25mg of residual ozone gas per liter. Summarizing the above results, it is considered that Giardia infection is regarded as water-borne disease and the cysts are able to be controlled by the application with the disinfectants in the water supply systems.

  • PDF

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.

Behavior Analysis of Concrete Structure under Blast Loading : (II) Blast Loading Response of Ultra High Strength Concrete and Reactive Powder Concrete Slabs (폭발하중을 받는 콘크리트 구조물의 실험적 거동분석 : (II) 초고강도 콘크리트 및 RPC 슬래브의 실험결과)

  • Yi, Na Hyun;Kim, Sung Bae;Kim, Jang-Ho Jay;Cho, Yun Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.565-575
    • /
    • 2009
  • In recent years, there have been numerous explosion-related accidents due to military and terrorist activities. Such incidents caused not only damages to structures but also human casualties, especially in urban areas. To protect structures and save human lives against explosion accidents, better understanding of the explosion effect on structures is needed. In an explosion, the blast load is applied to concrete structures as an impulsive load of extremely short duration with very high pressure and heat. Generally, concrete is known to have a relatively high blast resistance compared to other construction materials. However, normal strength concrete structures require higher strength to improve their resistance against impact and blast loads. Therefore, a new material with high-energy absorption capacity and high resistance to damage is needed for blast resistance design. Recently, Ultra High Strength Concrete(UHSC) and Reactive Powder Concrete(RPC) have been actively developed to significantly improve concrete strength. UHSC and RPC, can improve concrete strength, reduce member size and weight, and improve workability. High strength concrete are used to improve earthquake resistance and increase height and bridge span. Also, UHSC and RPC, can be implemented for blast resistance design of infrastructure susceptible to terror or impact such as 9.11 terror attack. Therefore, in this study, the blast tests are performed to investigate the behavior of UHSC and RPC slabs under blast loading. Blast wave characteristics including incident and reflected pressures as well as maximum and residual displacements and strains in steel and concrete surface are measured. Also, blast damages and failure modes were recorded for each specimen. From these tests, UHSC and RPC have shown to better blast explosions resistance compare to normal strength concrete.

The Changes of Serum Angiotensin Converting Enzyme Activity in Lung Cancer Patients (폐암 환자의 혈청 Angiotensin Converting Enzyme 활성도의 변화)

  • Jeong, Ki-Ho;Choi, Hyung-Seok;Yoo, Chul-Gyu;Lee, Kye-Young;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.4
    • /
    • pp.310-317
    • /
    • 1992
  • Background: Angiotensin converting enzyme is a glycoprotein peptidyldipeptide hydrolase which cleaves the c-terminal dipeptides of several oligopeptides. It is a menbrane-bound protein mainly synthesized by the endothelial cells. Since the lung has the largest capillary bed of any organ in the body, it is here that ACE acts on circulating substrates like angiotensin I and bradykinin. It is well known that ACE correlates with disease activity in sarcoidosis and also there are reports that changes in serum ACE activity are found in many acute and chronic lung diseases. So we planned this study to see if serum ACE activity can act as a prognostic factor in lung cancer. Methods: Forty-one newly diagnosed lung cancer patients were included in the study group. There were 19 patients with squamous cell lung cancer, 13 with adenocarcinoma, and 9 with small cell carcinoma. Patients were excluded from the study if they had high blood pressure, heart disease, liver disease, renal disease, or other lung disease. Serum ACE activity was analyzed according to cell type, staging, mode of treatment, and clinical response to treatment. Results: 1) There was no difference in serum ACE activity between lung cancer patients and the control group. Also no difference in serum ACE activity was found according to cancer cell type or staging. 2) In patients who underwent curative resection of lung cancer, serum ACE activity was decreased significantly after the operation. 3) In patients who were diagnosed as non-small cell lung cancer and were treated with 4 cycles of anti-cancer chemotherapy without clinical improvement, changes in serum ACE activity were not seen after the treatment. 4) In patients diagnosed as small cell lung cancer treated with 4 cycles of anti-cancer chemotherapy with clinical improvement, changes in serum ACE activity were also not observed. Conclusion: Serum ACE activity was decreased after lung resection but had no relation to cell type, staging, or clinical response to treatment in lung cancer patients. Therefore, serum ACE activity is not suitable in predicting clinical outcome of lung cancer patients.

  • PDF

Analysis of Acquisition Parameters That Caused Artifacts in Four-dimensional (4D) CT Images of Targets Undergoing Regular Motion (표적이 규칙적으로 움직일 때 생기는 4DCT 영상의 모션 아티팩트(Motion Artifact) 관련된 원인분석)

  • Sheen, Heesoon;Han, Youngyih;Shin, Eunhyuk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.243-252
    • /
    • 2013
  • The aim of this study was to clarify the impacts of acquisition parameters on artifacts in four-dimensional computed tomography (4D CT) images, such as the partial volume effect (PVE), partial projection effect (PPE), and mis-matching of initial motion phases between adjacent beds (MMimph) in cine mode scanning. A thoracic phantom and two cylindrical phantoms (2 cm diameter and heights of 0.5 cm for No.1 and 10 cm for No.2) were scanned using 4D CT. For the thoracic phantom, acquisition was started automatically in the first scan with 5 sec and 8 sec of gantry rotation, thereby allowing a different phase at the initial projection of each bed. In the second scan, the initial projection at each bed was manually synchronized with the inhalation phase to minimize the MMimph. The third scan was intentionally un-synchronized with the inhalation phase. In the cylindrical phantom scan, one bed (2 cm) and three beds (6 cm) were used for 2 and 6 sec motion periods. Measured target volume to true volume ratios (MsTrueV) were computed. The relationships among MMimph, MsTrueV, and velocity were investigated. In the thoracic phantom, shorter gantry rotation provided more precise volume and was highly correlated with velocity when MMimph was minimal. MMimph reduced the correlation. For moving cylinder No. 1, MsTrueV was correlated with velocity, but the larger MMimph for 2 sec of motion removed the correlation. The volume of No. 2 was similar to the static volume due to the small PVE, PPE, and MMimph. Smaller target velocity and faster gantry rotation resulted in a more accurate volume description. The MMimph was the main parameter weakening the correlation between MsTrueV and velocity. Without reducing the MMimph, controlling target velocity and gantry rotation will not guarantee accurate image presentation given current 4D CT technology.

The Usefulness of Noninvasive Positive Pressure Ventilation in Patients With Acute Respiratory Failure after Extubation (기관내 관 제거 후 발생한 급성 호흡부전에서 비침습적 양압 환기법의 유용성)

  • Na, Joo-Ock;Lim, Chae-Man;Shim, Tae-Sun;Park, Joo-Hun;Lee, Ki-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.350-362
    • /
    • 1999
  • Background: Acute Respiratory failure which is developed after extubation in the weaning process from mechanical ventilation is an important cause of weaning failure. Once it was developed, endotracheal reintubation has been done for respiratory support. Noninvasive Positive Pressure Ventilation (NIPPV) has been used in the management of acute or chronic respiratory failure, as an alternative to endotracheal intubation, using via nasal or facial mask. In this study, we evaluated the usefulness of NIPPV as an alternative method of reintubation in patients who developed acute respiratory failure after extubation. Method: We retrospectively analyzed thirty one patients(eighteen males and thirteen females, mean ages $63\pm13.2$ years) who were developed acute respiratory failure within forty eight hours after extubation, or were extubated unintentionally at medical intensive care unit(MICU) of Asan Medical Center. NIPPV was applied to the patients. Ventilatory mode of NIPPV, level of ventilatory support and inspiratory oxygen concentration were adjusted according to the patient condition and results of blood gas analysis by the attending doctors at MICU. NIPPV was completely weaned when the patients maintained stable clinical condition under 8 $cmH_2O$ of pressure support level. Weaning success was defined as maintenance of stable spontaneous breathing more than forty eight hours after discontinuation of NIPPV. Respiratory rate, heart rate, arterial blood gas analysis, level of pressure support, and level of PEEP were monitored just before extubation, at thirty minutes, six hours, twenty four hours after initiation of NIPPV. They were also measured at just before weaning from NIPPV in success group, and just before reintubation in failure group. Results: NIPPV was successfully applied to thirty-one patients of thirty-two trials and one patient could not tolerated NIPPV longer than thirty minutes. Endotracheal reintubation was successfully obviated in fourteen patients (45%) among them. There was no difference in age, sex, APACHE III score on admission at MICU, duration of intubation, interval from extubation to initiation of NIPPV, baseline heart rate, respiratory rate, arterial blood gas, and $PaO_2/FiO_2$ between the success and the failure group. Heart rate and respiration rate were significantly decreased with increase $SaO_2$ after thirty minutes of NIPPV in both groups(p<0.05). However, in the patients of failure group, heart rate and respiratory rate were increased again with decrease in $SaO_2$ leading to endotracheal reintubation. The success rate of NIPPV treatment was significantly higher in the patients with COPD compared to other diseases(62% vs 39%) (p=0.007). The causes of failure were deterioration of arterial blood gas without aggravation of underlying disease(n=9), aggravation of undelying disease(n=5), mask intolerance(n=2), and retained airway secretion(n=l). Conclusion: NIPPV would be a useful therapeutic alternative which can avoid reintubation in patient who developed acute respiratory failure after extubation.

  • PDF

Automatic gasometer reading system using selective optical character recognition (관심 문자열 인식 기술을 이용한 가스계량기 자동 검침 시스템)

  • Lee, Kyohyuk;Kim, Taeyeon;Kim, Wooju
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.2
    • /
    • pp.1-25
    • /
    • 2020
  • In this paper, we suggest an application system architecture which provides accurate, fast and efficient automatic gasometer reading function. The system captures gasometer image using mobile device camera, transmits the image to a cloud server on top of private LTE network, and analyzes the image to extract character information of device ID and gas usage amount by selective optical character recognition based on deep learning technology. In general, there are many types of character in an image and optical character recognition technology extracts all character information in an image. But some applications need to ignore non-of-interest types of character and only have to focus on some specific types of characters. For an example of the application, automatic gasometer reading system only need to extract device ID and gas usage amount character information from gasometer images to send bill to users. Non-of-interest character strings, such as device type, manufacturer, manufacturing date, specification and etc., are not valuable information to the application. Thus, the application have to analyze point of interest region and specific types of characters to extract valuable information only. We adopted CNN (Convolutional Neural Network) based object detection and CRNN (Convolutional Recurrent Neural Network) technology for selective optical character recognition which only analyze point of interest region for selective character information extraction. We build up 3 neural networks for the application system. The first is a convolutional neural network which detects point of interest region of gas usage amount and device ID information character strings, the second is another convolutional neural network which transforms spatial information of point of interest region to spatial sequential feature vectors, and the third is bi-directional long short term memory network which converts spatial sequential information to character strings using time-series analysis mapping from feature vectors to character strings. In this research, point of interest character strings are device ID and gas usage amount. Device ID consists of 12 arabic character strings and gas usage amount consists of 4 ~ 5 arabic character strings. All system components are implemented in Amazon Web Service Cloud with Intel Zeon E5-2686 v4 CPU and NVidia TESLA V100 GPU. The system architecture adopts master-lave processing structure for efficient and fast parallel processing coping with about 700,000 requests per day. Mobile device captures gasometer image and transmits to master process in AWS cloud. Master process runs on Intel Zeon CPU and pushes reading request from mobile device to an input queue with FIFO (First In First Out) structure. Slave process consists of 3 types of deep neural networks which conduct character recognition process and runs on NVidia GPU module. Slave process is always polling the input queue to get recognition request. If there are some requests from master process in the input queue, slave process converts the image in the input queue to device ID character string, gas usage amount character string and position information of the strings, returns the information to output queue, and switch to idle mode to poll the input queue. Master process gets final information form the output queue and delivers the information to the mobile device. We used total 27,120 gasometer images for training, validation and testing of 3 types of deep neural network. 22,985 images were used for training and validation, 4,135 images were used for testing. We randomly splitted 22,985 images with 8:2 ratio for training and validation respectively for each training epoch. 4,135 test image were categorized into 5 types (Normal, noise, reflex, scale and slant). Normal data is clean image data, noise means image with noise signal, relfex means image with light reflection in gasometer region, scale means images with small object size due to long-distance capturing and slant means images which is not horizontally flat. Final character string recognition accuracies for device ID and gas usage amount of normal data are 0.960 and 0.864 respectively.

ICT Medical Service Provider's Knowledge and level of recognizing how to cope with fire fighting safety (ICT 의료시설 기반에서 종사자의 소방안전 지식과 대처방법 인식수준)

  • Kim, Ja-Sook;Kim, Ja-Ok;Ahn, Young-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2014
  • In this study, ICT medical service provider's level of knowledge fire fighting safety and methods on coping with fires in the regions of Gwangju and Jeonam Province of Korea were investigated to determine the elements affecting such levels and provide basic information on the manuals for educating how to cope with the fire fighting safety in medical facilities. The data were analyzed using SPSS Win 14.0. The scores of level of knowledge fire fighting safety of ICT medical service provider's were 7.06(10 point scale), and the scores of level of recognizing how to cope with fire fighting safety were 6.61(11 point scale). level of recognizing how to cope with fire fighting safety were significantly different according to gender(t=4.12, p<.001), age(${\chi}^2$=17.24, p<.001), length of career(${\chi}^2$=22.76, p<.001), experience with fire fighting safety education(t=6.10, p<.001), level of subjective knowledge on fire fighting safety(${\chi}^2$=53.83, p<.001). In order to enhance the level of understanding of fire fighting safety and methods of coping by the ICT medical service providers it is found that: self-directed learning through avoiding the education just conveying knowledge by lecture tailored learning for individuals fire fighting education focused on experiencing actual work by developing various contents emphasizing cooperative learning deploying patients by classification systems using simulations and a study on the implementation of digital anti-fire monitoring system with multipoint communication protocol, a design and development of the smoke detection system using infra-red laser for fire detection in the wide space, video based fire detection algorithm using gaussian mixture mode developing an education manual for coping with fire fighting safety through multi learning approach at the medical facilities are required.