• Title/Summary/Keyword: $360^{\circ}$

Search Result 634, Processing Time 0.033 seconds

The Performance Analysis and Design of Selling Spectacle Lenses in Domestic Market (국내 시판 안경렌즈의 성능 분석 및 설계)

  • Kim, Se-Jin;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.355-360
    • /
    • 2010
  • Purpose: Analysis performance for spectacle lens which sales in domestic market and optimization design a spectacle lens which is corrected aberration. Methods: Measured center thickness, radius and aspherical surface coefficient for spherical and aspherical lenses which were ${\pm}$5.00D. Refractive index for every lens was 1.6 and they came from 4 different companies. I used 3 types of equipment to measure lenses. ID-F150 (Mitutoyo) : Center Thickness, FOCOVISION (SR-2, Automation Robotics) : Radius, PGI 1240S (Taylor Hobson) : Aspherical surface coefficient. Designed a lens which had 27 mm of distance from lens rear surface to center of eye, 4 mm of pupil diameter and small aberration on center vision $30^{\circ}C$. To shorten axial distance compared with the measured lens rise merits for cosmetic. Lens Design tool was CODE V (Optical Research Associates). Results: -5.00D aspherical lens had somewhat high astigmatism and distortion compared with the spherical lens. But it had a merit for cosmetic because of short axial height and decrease edge thickness. Improved a performance of distortion and ascertain merits for cosmetic due to short axial height and decrease edge thickness same as (-) lens in case of +5.00 aspherical lens. Though an optimization process front surface aspherical lens had a good performance for astigmatism and distortion and the merit for beauty compared with measured spherical lens. Conclusions: Design trend for domestic aspherical lens is decrease axial height and thickness to increase a merit for cosmetic not but increase performance of aberration. From design theory for optimization design front surface aspherical spectacle lens which has improved performance of aberration and merit for cosmetic at the same time compared with the measured lens. Expect an improved performance from design back aspherical lens compared with front aspherical lens.

Mechanical strength of Zirconia Abutment in Implant Restoration (지르코니아 임플란트 지대주의 기계적 강도에 관한 연구)

  • Shin, Sung-ae;Kim, Chang-Seop;Cho, Wook;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.349-360
    • /
    • 2009
  • Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

A Suggested Air Sampling Strategy for Bioaerosols in Daycare Center Settings (어린이활동공간에서의 바이오에어로졸 포집 전략)

  • Jo, JungHeum;Park, Jun-sik;Kim, Sung-Yeon;Kwon, Myung hee;Kim, Ki Youn;Choi, Jeong-Hak;Seo, SungChul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.324-333
    • /
    • 2016
  • Objectives: We aimed to compare the sampling performance of different flow-based impactor samplers for collecting fungal spores and bacteria and to explore the association of the level of bioaerosols with activity patterns of occupants in daycare center settings. Methods: For comparison of sampling performance, two different flow-based samplers (greater than 100 L/min or not) were selected; a low flow-based sampler (one-stage Andersen sampler) and two high flow-based samplers (DUO SAS SUPER 360 sampler, BUCK bio-culture sampler). We collected airborne mold and bacteria in 30 daycare centers with various levels of contaminated air. Three repeat samplings per each sampler were performed. Mold and bacteria were grown for 96 hours at $25{\pm}1^{\circ}C$ and 48 hours at $35{\pm}1^{\circ}C$, respectively. The Andersen and SAS samplers were used for investigating the association between the level of bioaerosols and the activity patterns of occupants in daycares. Particular matters 10($PM_{10}$), temperature, and relative humidity were monitored as well. Samplings were carried out with one-hour interval from 9 to 5 O'clock. For statistical comparisons, Kruskal-Wallis test, Wilcoxon's signed rank test, and multiple regression analysis were carried out. Results: The airborne level of molds by the low flow-based sampler were significantly higher than that of high flow-based samplers (indoor, P=0.037; outdoor, P=0.041). However, no statistical difference was observed in the airborne level of bacteria by each sampler. Also the level of bioaerosols varied by the time, particularly with different activity patterns in daycare centers. The higher level of mold and bacteria were observed in play time in indoor. Similarly, the concentrations of $PM_{10}$ were significantly associated with the level of bioaerosols (P<0.05). Conclusions: Our findings indicate that the flow rate of sampler, rather than total air volume, could be able to affect the results of sampling. Also, the level of airborne mold and bacteria vary behavior patterns of occupants in indoor of daycare settings. Therefore, different samplers with other flow rate may be selected for mold or bacteria sampling, and activity patterns should be considered for bioaerosol sampling as well.

Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan (Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구)

  • Kim, Jung-Yul;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

Modified Atmosphere Packaging of Fresh Strawberries by Antimicrobial Plastic Films (항균성 플라스틱 필름을 이용한 딸기의 환경기체조절포장)

  • Chung, Sun-Kyung;Cho, Sung-Hwan;Lee, Dong-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.1140-1145
    • /
    • 1998
  • Low density polyethylene (LDPE) films incorporated with 1% antimicrobial agents of Rheum palmatum extract, Coptis chinensis extract, and Ag-substituted inorganic zirconium matrix, were applied to modified atmosphere packaging of 200 g fresh strawberries. Plain LDPE film package, PVC wrap and perforative pinhole package of the film impregnated with 1% Rheum palmatum extract were also constructed for comparative purpose. All the packages were stored for 13 days at $5^{\circ}C$ and measured in package atmosphere, microbial count and quality attributes of the strawberry fruits. The antimicrobial LDPE films retarded the growth in total aerobic bacteria, lactic acid bacteria and yeast on the fruits, and resulted in significantly lower decay. The degrees of reduced microbial growth and fruit decay in the antimicrobial film packages were more pronounced, when applied by hermetical sealing to produce the modified atmospheres of low $O_2$ (<4.0%) and $CO_2$ concentrations with $6.3{\sim}9.0%$. The hermetically sealed packages of antimicrobial LDPE films also showed better retention of fruit firmness and did not give any negative effect on the physical and chemical qualities of strawberries.

  • PDF

Effect of Silicon on the Corrosion Characteristics of Zirconium (Zr의 부식특성에 미치는 Si의 영향)

  • Jeon, Chi-Jung;Kim, Hee-Suk;Kim, Yong-Deok;Hong, Hyun-Seon;Kim, Seon-Jin;Lee, Kyung-Sub
    • Korean Journal of Materials Research
    • /
    • v.8 no.6
    • /
    • pp.513-519
    • /
    • 1998
  • Zr-Si binary alloys containing 0.01 to O.lwt.%Si were prepared to investigate the effect of Si on the corrosion behavior of Zr. Corrosion test was performed in pure water at 36$0^{\circ}C$ under a pressure of 2660psi for 100days. The alloys containing 0.01 wt. % and 0.05wt. %Si had the black and uniform oxide film and didn't show the transition of corrosion rate. However. the alloys containing O.lwt.%Si had white oxide film and showed the trasition of corrosion rate at 70 days corrosion test. The weight gain increased with the increasing Si content from 0.01 to 0.1 wt.%. The variation of Si contents had no effect on changing the oxide structure but had significant effect on the electrical resistivity of oxide. The electrical resistivity decreased with increasing Si content. The fraction of precipitates in the Zr-Si binary alloys. identified as tetragonal $Zr_{3}$Si increased with increasing Si content. The increase of the volume fraction of precipitates is thought to be responsible for the increase of weight gain due to short circuit effect of precipitate.

  • PDF

Effects of commonly used infusion method on catechin content and antioxidant capacities of pure green tea packaged in tea bags (음용 조건으로 추출한 티백 형태 순수 녹차의 카테킨 함량 및 산화방지능)

  • Kim, Mi-Seon;Rha, Chan-Su;Kim, Dae-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.356-360
    • /
    • 2019
  • To evaluate antioxidant capacities and total phenolic, flavonoid, and catechin contents of pure green tea packaged in tea bags, green tea bags of 10 commercial brands were purchased and analyzed. Considering commonly used infusion methods, green tea bags were extracted using 150 mL of spring water at $70^{\circ}C$ for 2 min. Ten brands of green tea showed a wide range of total phenolic content (46.3-93.9 mg gallic acid equivalents/g), total flavonoid content (10.3-21.7 mg catechin equivalents/g), and antioxidant capacities (88.8-175.6 mg and 87.9-183.5 mg vitamin C equivalents/g for DPPH and ABTS assays, respectively). Total catechin content of green tea ranged from 33.8-74.7 mg/g, which corresponded to 43.0-108.3 mg/150 mL of cup. Collectively, these results suggest that daily consumption of 3.8-12.5 cups of green tea packaged in tea bags meets the recommended daily intake of catechins in green tea extract as a health functional foods in Korea.

Identification of Flavonoids from Extracts of Opuntia ficus-indica var. saboten and Content Determination of Marker Components Using HPLC-PDA (손바닥선인장 추출물의 플라보노이드 구조 규명 및 HPLC-PDA를 이용한 지표성분의 함량 분석)

  • Park, Seungbae;Kang, Dong Hyeon;Jin, Changbae;Kim, Hyoung Ja
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.2
    • /
    • pp.210-219
    • /
    • 2017
  • This study aimed to establish an optimal extraction process and high-performance liquid chromatography (HPLC)-photodiode array (PDA) analytical method for determination of marker compounds, dihydrokaempferol (DHK) and 3-O-methylquercetin (3-MeQ), as a part of materials standardization for the development of health functional foods from stems of Opuntia ficus-indica var. saboten (OFS). The quantitative determination method of marker compounds was optimized by HPLC analysis, and the correlation coefficient for the calibration curve showed very good linearity. The HPLC-PDA method was applied successfully to quantification of marker compounds in OFS after validation of the method in terms of linearity, accuracy, and precision. Ethanolic extracts from stems of O. ficus-indica var. saboten (OFSEs) were evaluated by reflux extraction at 70 and $80^{\circ}C$ with 50, 70, and 80% ethanol for 3, 4, 5, and 6 h. Among OFSEs, OFS70E at $80^{\circ}C$ showed the highest contents of DHK and 3-MeQ of $26.42{\pm}0.65$ and $3.88{\pm}0.29mg/OFS100g$, respectively. Furthermore, OFSEs were determined for their antioxidant activities by measuring 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging and lipid peroxidation (LPO) inhibitory activities in rat liver homogenate. OFS70E at $70^{\circ}C$ showed the most potent antioxidant activities with $IC_{50}$ values of $1.19{\pm}0.11$ and $0.89{\pm}0.09mg/mL$ in the DPPH radical scavenging and LPO inhibitory assays, respectively. To identify active components of OFS, various chromatographic separation of OFS70E led to isolation of 11 flavonoids: dihydrokaempferol, dihydroquercetin, 3-O-methylquercetin, quercetin, isorhamnetin 3-O-glucoside, isorhamnetin 3-O-galactoside, narcissin, kaempferol 7-O-glucoside, quercetin 3-O-galactoside, isorhamnetin, and kaempferol 3-O-rutinoside. The results suggest that standardization of DHK in OFSEs using HPLC-PDA analysis would be an acceptable method for the development of health functional foods.

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.