• Title/Summary/Keyword: ${\mu}$-Analysis

Search Result 7,115, Processing Time 0.035 seconds

Fabrication of Ultra-fine Rhodium Wire Using Multi-pass Wire Drawing Process (다단 신선공정을 이용한 초극세 로듐 와이어 제조)

  • Lee, S.K.;Lee, S.Y.;Lee, I.K.;Hwang, S.K.
    • Transactions of Materials Processing
    • /
    • v.28 no.5
    • /
    • pp.275-280
    • /
    • 2019
  • The aim of this study is to fabricate an ultra-fine pure rhodium wire using multi-pass wire drawing process. To manufacture $30{\mu}m$ ultra-fine rhodium wire from the initial $50{\mu}m$ wire, a multi-pass wire drawing process was designed based on the uniform reduction ratio theory. The elastic-plastic finite element analysis was then conducted to validate the efficacy of the designed process. The drawing load, drawing stress, and the distribution of the effective strain were evaluated using the finite element analysis. Finally, the wire drawing experiment was performed to validate the designed wire drawing process. From the results of the experiment, the diameter of the final drawn wire was found to be $29.85{\mu}m$.

Multiple accelerated degradation test and failure analysis for $Ni-BaTiO_3$ MLCCs ($Ni-BaTiO_3$ MLCCs에 대한 복합 가속 열화 시험 및 고장 분석)

  • Kim, Jung-Woo;Kim, Jin-Seong;Lee, Hee-Soo;Kang, Do-Won;Kim, Jeong-Wook
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.2
    • /
    • pp.102-105
    • /
    • 2009
  • The accelerated life time test of the MLCCs with different $BaTiO_3$ particle sizes were conducted at $150^{\circ}C$, 75 V condition and the effect of $BaTiO_3$ particle size on the breakdown voltage and degradation characteristics of MLCCs was investigated. The MLCCs were prepared by using the $BaTiO_3$ particles having the size of $0.525{\mu}m$, $0.555{\mu}m$, $0.580{\mu}m$ and Ni-electrode, respectively. The MLCCs which have the particle size of $0.525{\mu}m$, $0.555{\mu}m$, and $0.580{\mu}m$, respectively were confirmed to meet the standard requirements of X5R(change capacitance within ${\pm}15%$ at $-55{\sim}85^{\circ}C$) by TCC(Temperature Coefficient of Capacitance). The effect of the $BaTiO_3$ particle size on the insulation resistance behavior of MLCCs was confirmed by BDV(Breakdown Voltage) measurements and the cause and degree of degradation of MLCCs were characterized by XPS analysis after the accelerated life test. The MLCCs with $0.525{\mu}m-BaTiO_3$ showed better insulation resistance and BDV characteristics compare to other MLCCs and XPS analysis revealed that the MLCCs degradation is caused by the NiO peak and $BaTiO_3$ peak decrease.

Pollutant Content of the Sediments in the Drain Channel of Paved Catchments in Coastal Areas (연안역 불투수지역 배수구 퇴적물의 오염특성에 관한 연구)

  • Kim, Yeon-Seok;Park, Ki-Soo;Kim, Young-Chul
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.523-534
    • /
    • 2011
  • In this study, the particle size distribution and pollutants content of sediments collected from different sites in the coastal area of Chungnam province were analyzed. The sediment samples were collected from different parking lots near beaches, harbors, museum and bridges. The particle size distribution analysis showed that the particle is generally $106-500{\mu}m$ and the effective size $D_{10}$ ranges from 40 to $60{\mu}m$ while the $D_{50}$ and $D_{60}$ ranges from 200 to $810{\mu}m$ and 235 to $1005{\mu}m$, respectively. For particle size $D_{10}$, there was no significant difference in all sites. However, for $D_{50}$ and $D_{60}$, the range is large. Sediment analysis implicates that as the particle size decreases, the pollutant content increases. This is because smaller particles have higher specific surface area resulting to have more adsorption capacity. Particles from tires, emission gas from vehicles and dust particles belongs to smaller particles. For particle sizes less than $63{\mu}m$, the analysis showed that as the particles become coarser, the concentration of VS, $COD_{cr}$, TN, and TP is at least 2 to 14 times higher. Cu and Pb were detected in all sites and shows a higher concentration with smaller particle size. Cu concentration are almost the same for all sites but in the case of Pb, the sediments from Sinjindo has higher concentration of up to 2 to 3 times as compared to those collected from the other sites. In the Beach site as well as in the Seocheon Ocean Museum, Cd was contained only in fine particles. However, in Daechon Harbor and Sinjindo Bridge sites, Cd was detected in all the sediment particle size.

Quantitative Analysis of Methotrexate using Hitach-7600 P-module (Hitach-7600 P-module을 이용한 Methotrexate 정량분석 평가)

  • Kim, Min-Eui;Cha, Kyong-Ho;Kim, Seung-Hee;Kim, Nam-Joo;Chae, Hyo-Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.4
    • /
    • pp.167-172
    • /
    • 2009
  • Methotrexate (MTX) in one of the antineoplastic drug and it is known to effective to management of acute lymphoblastic leukemia in children, management of choriocarcinoma and related trophoblastic tumors in women, management of carcinomas of the breast, tongue, pharynx, and tests, maintenance of remission in leukemia and treatment of serve, debilitating psoriasis. Intermediate to high-dose methotrexate administration followed by leucovorin rescue is effective in treatment of carcinoma of the lung and osteogenic sarcoma. Intrathecal administration is effective in treating meningeal leukemia or lymphoma. There are FPIA (Fluorescence polarization immunoassay) and EMIT (Enzyme multiplied immunotechique) methods that measure for MTX. We evaluated the FPIA and EMIT methods. MTX were measured by Hitachi-7600 P-module using EMIT and FPIA using TDX in the sera 60 patients. The performance characteristics evaluated were, light influence, linearity, comparison with FPIA. Also, precision evaluated were three level controls through put following CLSI evaluation protocols (EP10-A). When the MTX value of $4.16{\pm}5.78{\mu}{\mu}mol/L$ (mean, SD) by the Hitachi-7600 P-module was compared with that of $4.05{\pm}5.47{\mu}{\mu}mol/L$ by FPIA, coefficients of correlation of 0.988 was obtained. The regression equation was Y (Hitachi-7600 P-module) = 0.9408 x (FPIA) + 0.1316 (r=0.9885, n=60). CVs of MTX measured by Hitachi 7600 P-module was 6.78% at $0.33{\mu}{\mu}mol/L$, 0.96% at $1.16{\mu}{\mu}mol/L$, and 0.96% at $8.04{\mu}{\mu}mol/L$. The precision was excellent in each group. The linearity was acceptable. We evaluated that MTX is light-sensitive on prolonged exposure to direct sunlight. Comparing with the FPIA using TDX, the Hitachi-7600 P-module using EMIT showed good coefficient of correlation and precision. Therefore the Hitachi-7600 P-module can replace the FPIA for quantitative analysis of MTX.

  • PDF

Cytogenetic Analysis of Spotty Belly Greenling (Hexagrammos agrammus) and Greenling (H. otakii) (노래미 (Hexagrammos agrammus)와 쥐노래미 (H. otakii)의 세포유전학적 연구)

  • Sim Mi A;Noh Jae Koo;Nam Yoon Kwon;Kim Dong Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.6
    • /
    • pp.682-685
    • /
    • 2002
  • Cytogenetic analysis was conducted to obtaining informations for genetic improvement of spotty belly greenling (Hexagrmmos agrammus) and greenling (H. otakii) in aquaculture. Erythrocytes of spotty belly greenling were slightly larger than those of greenling (p<0.05). The nuclear volume of spotty belly greening erythrocytes averaged 15.14 $\pm$ 0.92 ${\mu}m^3$ while that of greening averaged 14.61 $\pm$ 0.15 $\mu$m^3 the difference was not significant (p>0.05). Consequently, genome size of spotty belly greenling was also slightly larger than those of greenling. DNA content per cell of spotty belly greenling and greenling were 2.15 pg and 2.10 pg, respectively. The modal chromosome number of both greenling species were same as 2n=48 and karyotypes were also identical as 2 metacentrics, 11 snbrnetacentrics and 11 acrocentric pairs $(W: 74), There was no evidence of polymorphism including aneuploidy or sex-related heterornorphisrn for all specimens examined. The nuclear organizer regions (NOR_s)$ were localized on a small acrocentric chromosome pair in both species, Spotty belly greenling showed large sizes of active rRNA coding regions in their chromosomes. However, greenling examined only small sizes of active rRNA coding regions with dimorphism.

Robust Analysis of a μ-Controller for a Cable-Stayed Bridge with Various Uncertainties (사장교에서 다양한 불확실성에 대한 μ-제어기의 강인성 해석)

  • Park, Kyu Sik;Spencer, B.F.Jr.;Kim, Chun Ho;Lee, In Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.849-859
    • /
    • 2006
  • This paper presents an extensive robust analysis of a ${\mu}$-controller in the hybrid system for various uncertainties using the benchmark cable-stayed bridge. The overall system robustness may be deteriorated by introducing active devices and the active controller may cause instability due to small margins. Therefore, a ${\mu}$-synthesis method that simultaneously guarantees the performance and stability of the closed-loop system (robust performance) with uncertainties is used for active devices to enhance the robustness in company with the inherent reliability of passive devices. The robustness of the ${\mu}$-synthesis method is investigated with respect to the additional mass on the deck, structural stiffness matrix perturbation, time delay of actuator, and combinations thereof. Numerical simulation results show that the proposed control system has the good robustness without loss of control performances with respect to various uncertainties under earthquakes considered in this study. Furthermore, the control system robustness is more affected by the perturbation of structural stiffness matrix than others considered in this study. Therefore, the hybrid system controlled by a ${\mu}$-synthesis method could be proposed as an improved control strategy for a seismically excited cable-stayed bridge containing many uncertainties.

Mercury Level in Hair of Primary School Children in Korea and China

  • Park, Hee-Jin;Kim, Dae-Seon;Moon, Jeong-Suk;Yang, Won-Ho;Son, Bu-Soon
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.3
    • /
    • pp.235-245
    • /
    • 2008
  • Exposure to mercury was assessed in 125 Korean (Gwangju and Busan) and 373 Chinese primary school students (Xinguang village, Goumen town) using hair mercury analysis from November 2006 to September 2007. The geometric mean concentration of mercury was higher among Korean children with recording 0.73 ${\mu}g$/g, compared to Chinese children of 0.12 ${\mu}g$/g, which indicated statistically difference (P<0.01). The mean concentration of Korean children living near incineration facilities was higher by recording 0.76 ${\mu}g$/g while the average concentration of their counterpart in Korea reached 0.69 ${\mu}g$/g. In case of Chinese children, those who are living near power plants showed higher level with posting 0.16 ${\mu}g$/g while the others recorded 0.10 ${\mu}g$/g (P<0.01). Intake of fish was found to be related to hair mercury level. In case of Korean children, those with high fish intake recorded 0.79 ${\mu}g$/g in terms of the geometric mean concentration while the others with low fish intake posted 0.61 ${\mu}g$/g. Among Chinese children, those who often eat fish recorded 0.13 ${\mu}g$/g compared to the others with low fish intake of 0.11 ${\mu}g$/g. On the other hand, amalgam dental fillings have limited influence on mean hair mercury level. As for vaccination, within a month of vaccination, the geometric mean concentration of Korean children reached 0.76 ${\mu}g$/g, and in case of 15 days after injection, the level was 1.20 ${\mu}g$/g. In China, the level of children at one month after receiving injection stood at 0.15 ${\mu}g$/g while the level within 15 days was 0.13 ${\mu}g$/g. Multiple regression analysis showed that BMI, passive smoking, and fish consumption are closely related to hair mercury level among the Korean subjects. In China, hair mercury level was affected by age, location, passive smoking, fish consumption, and vaccination. Explanatory power was 21.6% with $R^2$=0.216.

Fabrication and Performance of Microcolumnar CsI:Tl onto Silicon Photomultiplier (실리콘광증배관 기반의 미세기둥 구조 CsI:Tl 제작 및 평가)

  • Park, Chan-Jong;Kim, Ki-Dam;Joo, Koan-Sik
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.337-343
    • /
    • 2016
  • This study conducted the gamma ray spectroscopic analysis of the microcolumnar CsI:Tl deposited onto the SiPMs using thermal evaporation deposition. The SEM measured thickness of microcolumnar CsI:Tl and of its individual columns. From the SEM observation, the measured thickness of CsI:Tl were $450{\mu}m$ and $600{\mu}m$. The gamma ray spectroscopic properties of microcolumnar CsI:Tl, $450{\mu}m$ and $600{\mu}m$ thick deposited onto the SiPMs were analyzed using standard gamma ray sources $^{133}Ba$ and $^{137}Cs$. The spectroscopic analysis of microcolumnar CsI:Tl deposited onto the SiPMs included the measurements of response linearity over the $^{137}Cs$ gamma ray intensity; and gamma ray energy spectrum. Furthermore from the gamma ray spectrum measurement of $^{133}Ba$ and $^{137}Cs$, $450{\mu}m$ thick CsI:Tl showed good efficiency when measured with $^{133}Ba$ and $600{\mu}m$ thick CsI:Tl was highly efficient when measured with $^{137}Cs$.

Analysis of Carbonyl Compounds using DNPH Cartridge with LC-MS (DNPH cartridge/LC-MS 방법에 의한 카르보닐화합물 분석에 관한 연구)

  • Cho Deok-Hee;Song Il-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.201-208
    • /
    • 2006
  • Several carbonyl compounds are important because of their irritant and toxic properties, mutagenicity and carcinogenicity. Therefore, they are regulated in korean odor emission standard. In this study, atmospheric pressure ionization-mass spectrometry(API-MS) is used for the analysis of carbonyl compounds after derivatization with 2, 4-dinitrophenylhydrazine (DNPH) and liquid chromatographic separation. In the negative ion mode, the $[M-H]^-$ pseudomolecular ions are most abundant for the carbonyls. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearities ($r^2$) for carbonyls were $0.9977{\sim}0.9999$ when analyte concentration ranges from $25\;to\;250{\mu}g/L$(n=6). The relative standard deviations (%RSD) for carbonyls were $0.55{\sim}3.51%$ for concentration of $100{\mu}g/L$(n=5). The minimum detection limit (MDL) was $1.88{\mu}g/L$(0.27 ppb) for i-valeraldehyde. It was shown that LC-MS method has a great potential for carbonyl compounds analysis.

Determination of the Uranium Backgrounds in Lexan Films for Single Particle Analysis using FT-TIMS technique

  • Park, Su-Jin;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • v.2 no.2
    • /
    • pp.57-60
    • /
    • 2011
  • As background significantly affects measurement accuracy and a detection limit in determination of the trace amounts of uranium, it is necessary to determine the impurities in the Lexan detector film for single particle measurements by thermal ionization mass spectrometry coupled with fission track technique (FT-TIMS). We have prepared various micro sizes of the blank Lexan detector film using a micromanipulation technique for uranium measurements by TIMS. Few tens of fg of uranium background with no remarkable dependency on the film sizes were observed in the blank Lexan films with the sizes from $50{\times}50\;{\mu}m^2$ to $300{\times}300\;{\mu}m^2$. Based on the determination of the uranium background in the Lexan film, any background correction is necessary in the isotopic analysis of a uranium single particle with micron sizes when the particle bearing Lexan film is dissected with less than $300{\times}300\;{\mu}m^2$ size. The isotopic analysis of a uranium particle in U030 standard material using TIMS was carried out to verify the applicability of the Lexan film to the single particle analysis with high accuracy and precision.