• Title/Summary/Keyword: ${\gamma}-rays$

Search Result 594, Processing Time 0.028 seconds

The Radioprotective Effect of Kuei-Pi-Tang as a prescription of Traditional Chinese Medicine in Mice (생쥐에서 귀비탕 및 구성단미의 방사선 방호효과)

  • Kim, Sung-Ho;Lee, Song-Eun;Oh, Heon;Yang, Jung-Ah;Chung, Chi-Young;Jang, Jong-Sik;Yu, Young-Beob;Jo, Sung-Kee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.3
    • /
    • pp.698-704
    • /
    • 1999
  • In this study, we evaluated the radioprotective effects of Kuei Pi Tang and its ingredients, as a prescription of traditional Oriental medicine. The jejunal crypt survival, endogenous spleen colony formation, and apoptosis in jejunal crypt cells were investigated in mice irradiated with high and low dose of ${\gamma}$ rays. In the mice administered with Kuei Pi Tang extract before irradiation, the jejunal crypts were protected significantly(p<0.005) and the frequency of radiation induced apoptosis was reduced(p<0.05). In the experiment on the effects of the ingredients of Kuei Pi Tang, the results indicated that the extract of Dangui(Angelica sinensis), Suanzaoren(Zizyphus valgaris), Rensan (Panax ginseng), Fuling(Poria cocos) and Muxiang(Saussurea lappa) might have a major radioprotective effect. Although the mechanisms of this inhibitory effect remain to be elucidated, these results indi cated that Kuei Pi Tang might be a useful radioprotector, especially since it is a relatively nontoxic natural product.

  • PDF

비정질 실리콘을 이용한 방사선 계측시 Photoconductive Gain의 특성

  • Lee, Hyeong-Gu;Sin, Gyeong-Seop
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.307-313
    • /
    • 1997
  • he photoconductive gain mechanism in amorphus silicon devices was investigated in connection with applications to radiation detection. Various device types such as p-i-n, n-i-n and i-i-p-i-n structures were fabricated and tested. Photoconductive gain was measured in two time scales : one for short pulses of visible light(<$1{\mu}sec$) which simulate the transit of energetic charged particles or ${\gamma}$-rays, and the other for rather long pulses of light(1msec) which simulate x-ray exposure in medical imaging, We used two definitions of phtoconductive gain : current gain and charge gain which is an integration of the current gain. We obtained typical charge gains of 3~9 for short pulses and a few hundreds for long pulses at a dark current density level of 10mA/$cm^2$. Various gain results are discussed in terms of the device structure, applied bias and dark current density.

  • PDF

Radiation Sensitivity of Some Toxigenic Molds Isolated from Deteriorated Rice (변질미(變質米)에서 분리된 독소생성(毒素生成)곰팡이의 방사선(放射線) 감수성(感受性))

  • Choi, Eon-Ho;Kim, Hong-Lyour;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.148-153
    • /
    • 1975
  • Seven toxigenic molds isolated from deteriorated rice in Korea, Aspergillus clavatus, Asp. flavus var. columnaris, Asp. fumigatus, Asp. ochraceus, Penicillium citrinum, Pen. implicatum, and Pen. islandicum, were examined for their sensitivity toward Co-60 gamma rays for survival. Conidia of all tested species showed survival curves of sigmoidal type, from which decimal reduction doses were found to vary in the range of $14{\sim}33$ krad, induction doses, in the range of $12{\sim}56$ krad and inactivation factors at 200 krad, in the range of $4.6{\sim}12.8$, all at a dose rate of 11.56 krad/min. Dose rate effects on the radiosensitivity of Asp. flavus and Pen. islandicum conidia indicated that the higher dose rate (11.56 krad/min) caused decreases in decimal reduction doses as compared with the lower dose rate (2.67 krad/min).

  • PDF

Improvement of physiological activity and processing quality through structural transformation of natural biomaterials based on radiation technology (방사선분자변환기술 기반 천연 생물소재 구조변환에 따른 가공적성 및 생리활성 증진 연구)

  • Byun, Eui-Baek;Song, Ha-Yeon;Kim, Hye-Min;Kim, Woo Sik;Lee, Seung Sik;Choi, Dae Seong;Lim, Sang-Yong;Chung, Byung Yeoup
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.3
    • /
    • pp.249-259
    • /
    • 2018
  • Radiation technology (RT) has long been applied in various fields for increasing the safety and shelf-life of foods by controlling pathogen-induced poisoning. RT was introduced for the first time in Korea in the 1950s to eliminate harmful microorganisms in food materials. In the 1980s, RT had been scientifically proven to be effective for the sterilization of food and public health products. In recent years, irradiation with gamma rays has also been used for improving physiological properties through the structural modification of natural molecules, which has been proposed to be applicable to various industries. In particular, radiation transformation technology (RTT), which involves the development of new functional compounds through the molecular conversion of natural biomaterials, is becoming a new high-value technology as a fusion technique of RT and biotechnology. The present reports have suggested that RTT can be an effective tool for the development of new functional compounds and improvement of the physiological activity of biomolecules.

Detection of Irradiated Beans Using the DNA Comet Assay (DNA Comet Assay를 이용한 콩류의 방사선 조사 확인)

  • 오경남;김경은;양재승
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.5
    • /
    • pp.843-848
    • /
    • 2000
  • The single cell-gel electrophoresis assay (comet assay) was used to identify irradiated beans. Soy beans, kidney beans, and red beans were irradiated with $^{60}Co$ gamma rays at 0.1, 0.3, 0.5, 0.7, and 1.0 kGy. Beans were peeled out, crushed lightly, and treated with phosphate-buffered saline (PBS) to extract cells. The extracted cell suspension was mixed with agarose gel solution and spread on an agarose precoated slide. After lysis of the cells, they were subjected to microgel electrophoresis for 2 minutes, and then silver-stained. We found that the DNA fragments of the irradiated samples were stretched, migrated out of the cells, and formed tails towards the anode giving the appearance of comets, while the unirradiated or the undamaged cells formed very short or no tails. The tail lengths of irradiated samples were significantly increased as irradiation dose increased at the above 0.3 kGy.

  • PDF

Anti-inflammatory Activity of Herbal Extracts through Inhibition of TNF-α, IL-6 and IL-8 (TNF-α, IL-6, IL-8 저해를 통한 천연약용식물 추출물의 항염증 특성)

  • Kim, Yong-Soo;Gwon, Hui-Jeong;Park, Jong-Seok;Lim, Youn-Mook;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.5 no.3
    • /
    • pp.273-277
    • /
    • 2011
  • This study evaluated the cytotoxicity and anti-inflammatory activities of natural herbal extracts including Houttuynia cordata and Eucommia ulmoides against human mast cell (HMC-1). Houttuynia cordata (HC) and Eucommia ulmoides(EU) were extracted with distilled water (at $75^{\circ}C$) and then freeze-dried for 5 days. Finally, the mixture of HC and EU were sterilized by ${\gamma}$-rays irradiation. Cytotoxicity of the mixture against HMC-1 cell was measured using cell counting kit-8 (CCK-8) assay. In addition, inflammatory mediator cytokines such as TNF-${\alpha}$, IL-6 and IL-8 were evaluated by ELISA kit on the HMC-1 cells with calcimycin A23187 and phorbol 12-myristate 13-acetate (PMA). The results showed that mixture of HC and EU had no cytoxicity and reduced TNF-${\alpha}$, IL-6, IL-8 response on HMC-1 cells.

A novel approach in voltage transient technique for the measurement of electron mobility and mobility-lifetime product in CdZnTe detectors

  • Yucel, H.;Birgul, O.;Uyar, E.;Cubukcu, S.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.731-737
    • /
    • 2019
  • In this study, a new measurement method based on voltage transients in CdZnTe detectors response to low energy photon irradiations is applied to measure the electron mobility (${\mu}_e$) and electron mobility-lifetime product $({\mu}{\tau})_e$ in a CdZnTe detector. In the proposed method, the pulse rise times are derived from low energy photon response to 59.5 keV($^{241}Am$), 88 keV($^{109}Cd$) and 122 keV($^{57}Co$) ${\gamma}-rays$ for the irradiation of the cathode surface at each detector for different bias voltages. The electron $({\mu}{\tau})_e$ product was then determined by measuring the variation in the photopeak amplitude as a function of bias voltage at a given photon energy using a pulse-height analyzer. The $({\mu}{\tau})_e$ values were found to be $(9.6{\pm}1.4){\times}10^{-3}cm^2V^{-1}$ for $1000mm^3$, $(8.4{\pm}1.6){\times}10^{-3}cm^2V^{-1}$ for $1687.5mm^3$ and $(7.6{\pm}1.1){\times}10^{-3}cm^2V^{-1}$ for $2250mm^3$ CdZnTe detectors. Those results were then compared with the literature $({\mu}{\tau})_e$ values for CdZnTe detectors. The present results indicate that, the electron mobility ${\mu}_e$ and electron $({\mu}{\tau})_e$ values in CdZnTe detectors can be measured easily by applying voltage transients response to low energy photons, utilizing a fast signal acquisition and data reduction and evaluation.

STUDY OF ULTRALUMINOUS X-RAY SOURCES IN SOME NEARBY GALAXIES

  • Singha, Akram Chandrajit;Devi, A Senorita
    • Journal of The Korean Astronomical Society
    • /
    • v.52 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • We present the results of the spectral and temporal analysis of eight X-ray point sources in five nearby (distance < 20 Mpc) galaxies observed with Chandra. For spectral analysis, an absorbed powerlaw and an absorbed diskblackbody were used as empirical models. Six sources were found to be equally fitted by both the models while two sources were better fitted by the powerlaw model. Based on model parameters, we estimate the X-ray luminosity of these sources in the energy range 0.3 - 10.0 keV, to be of the order of ${\sim}10^{39}ergs\;s^{-1}$ except for one source (X-8) with $L_X>10^{40}ergs\;s^{-1}$. Five of these maybe classified as Ultraluminous X-ray sources (ULXs) with powerlaw photon index within the range, ${\Gamma}{\sim}1.63-2.63$ while the inner disk temperature, kT ~ 0.68 - 1.93 keV, when fitted with the disk blackbody model. The black hole masses harboured by the X-ray point sources were estimated using the disk blackbody model to be in the stellar mass range, however, the black hole mass of one source (X-6) lies within the range $68.37M_{\odot}{\leq}M_{BH}{\leq}176.32M_{\odot}$, which at the upper limit comes under the Intermediate mass black hole range. But if the emission is considered to be beamed by a factor ~ 5, the black hole mass reduces to ${\sim}75M_{\odot}$. The timing analysis of these sources does not show the presence of any short term variations in the kiloseconds timescales.

Characteristics of Internal and External Exposure of Radon and Thoron in Process Handling Monazite (모나자이트 취급공정에서의 라돈 및 토론 노출 특성)

  • Chung, Eun Kyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.167-175
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate airborne radon and thoron levels and estimate the effective doses of workers who made household goods and mattresses using monazite. Methods: Airborne radon and thoron concentrations were measured using continuous monitors (Rad7, Durridge Company Inc., USA). Radon and thoron concentrations in the air were converted to radon doses using the dose conversion factor recommended by the Nuclear Safety and Security Commission in Korea. External exposure to gamma rays was measured at the chest height of a worker from the source using real-time radiation instruments, a survey meter (RadiagemTM 2000, Canberra Industries, Inc., USA), and an ion chamber (OD-01 Hx, STEP Co., Germany). Results: When using monazite, the average concentration range of radon was $13.1-97.8Bq/m^3$ and thoron was $210.1-841.4Bq/m^3$. When monazite was not used, the average concentration range of radon was $2.6-10.8Bq/m^3$ and the maximum was $1.7-66.2Bq/m^3$. Since monazite has a higher content of thorium than uranium, the effects of thoron should be considered. The effective doses of radon and thoron as calculated by the dose conversion factor based on ICRP 115 were 0.26 mSv/yr and 0.76 mSv/yr, respectively, at their maximum values. The external radiation dose rate was $6.7{\mu}Sv/hr$ at chest height and the effective dose was 4.3 mSv/yr at the maximum. Conclusions: Regardless of the use of monazite, the total annual effective doses due to internal and external exposure were 0.03-4.42 mSv/yr. Exposures to levels higher than this value are indicated if dose conversion factors based on the recently published ICRP 137 are applied.

Cesium removal in water using magnetic materials ; A review (자성체 물질을 이용한 수중의 세슘제거 동향)

  • Yeo, Wooseok;Cho, Byungrae;Kim, Jong Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.395-408
    • /
    • 2018
  • Even after the Fukushima nuclear accident in 2011, the rate of production of electric energy using nuclear energy is increasing, but there is a great danger such as the radioactive waste produced when using nuclear power, the catastrophic accident of nuclear power plant, and connection with nuclear weapons. In particular, Cs present in the ionic form of alkaline elements has a long half-life (30.17 years) because it is readily absorbed by the organism and emits intense gamma rays, thus presenting a serious radiation hazard. Therefore, it must be completely removed before it can be released into the natural ecosystem, because it can adversely affect not only humans but also natural ecosystems. Many adsorbents and ion exchangers which have high Cs removal efficiency have been used in recent years to completely separate and remove by self separation in water. Many adsorbents and ion exchangers which have high Cs removal efficiency have been used in recent years to completely separate and remove by self separation in water. In addition, researches have been doing to synthesize magnetic materials with adsorbents such as HCF and PB, and it shows a great effect in the removal rate of Cs present in wastewater or the maximum Cs adsorption amount. In particular, when a magnetic material was applied, excellent results were obtained in which only Cs was selectively removed from other cations. However, new problems such as applicability in the sea where Cs is directly released, applicability in various pH ranges, and failure to preserve the magnetizing force possessed by the magnetic body have been found. However, researches using ferromagnetic field with stronger magnetic properties than those of magnetic bodies is considered to be insufficient. Therefore, it is considered that if the researches combining the ferromagnetic field with the magnetization ability and functional adsorbents more actively, the radioactive material Cs which adversely affects the natural ecosystem can be effectively removed.