• 제목/요약/키워드: ${\gamma}-ray$

검색결과 1,805건 처리시간 0.031초

암환자에게 다빈도로 활용되는 한약제제 10종에 대한 요오드의 함량 분석 (Determination of Iodine Contents in Ten kinds of Frequently used Oriental Herb Medicinal Products for Cancer Patient)

  • 이창희;최정은;김선하;정용삼;문종화;유화승
    • 대한암한의학회지
    • /
    • 제16권1호
    • /
    • pp.41-53
    • /
    • 2011
  • Background and Objectives: Iodine is an essential constituent of the thyroid hormones associated with the growth and development of humans and animals as an inorganic nutrition. This element may be accumulated in human blood, tissues and body through the intake of foodstuffs, a beverage, a nutritional supplement and a medicine, among others. The aim of the research is to find out a better medicinal stuff for the thyroid cancer patient who required a low level of iodine diet. Methods: Neutron activation analysis (NAA) used for the iodine analysis is one of nuclear analytical techniques using radiation and radioisotopes and very useful as sensitive analytical technique for performing both qualitative and quantitative multi-elemental non-destructive analysis of major, minor and trace components in variety of environmental and biological materials. In this study, iodine contents in ten kinds of oriental herb medicinal products, which is frequently used to cancer patients are determined by using instrumental neutron activation analysis (INAA) at the HANARO research reactor. The samples prescribed are manufactured as powdered form for taking medicine easily. The analytical quality control is performed to assure an uncertainty of the measurement and to compensate the measured data using a biological certified reference material, NIST SRM 1572, Citrus Leaves. The measured value is $1.89{\pm}0.35mg/kg$, and the relative error is 2.88%, and relative standard deviation is 19 % due to high counting error by small counts of gamma ray spectrum. The standard deviations for other elements such as Cl, K, Mn and Na were in the range of 2 to 8%. Result: The level of iodine contents of Biki-huan, Chungryong-huan and Chungcho-huan, samples detected is less than 6 mg/kg except Hangam Plus sample (more than 210 mg/kg) and six samples were not detected. Iodine in the samples of Shoxiho-tang, Shopunghualhyl-tang, Shocungryong-tang, Banhasaxim-tang, Insampaedox-san and Myunyuk Plus were not measured, but possible level of content can be estimated from the detection limits. In addition, the concentrations of some major elements like Cl, K, Mn, Na, in the samples were determined with the detection limits. Conclusions: Most of samples showed low iodine contents of less than 6 mg/kg but it turned out that most of testing samples can be used to classify the level of iodine diet samples considering the recommended low level of iodine diet 50 ${\mu}g$/day, and a better medicinal stuff for the thyroid cancer patient can be found.

Re-188-DTPA (Diethylenetriaminepentaacetic acid)의 표지와 생체내 분포 (Labeling and Biodistribution of Re-188-DTPA (Diethylenetriaminepentaaceticacid))

  • 이진;김영주;장영수;정재민;신승애;정준기;이명철;고창순;이동수
    • 대한핵의학회지
    • /
    • 제31권4호
    • /
    • pp.427-432
    • /
    • 1997
  • Re-188은 반감기가 17시간이고 진단을 위한 영상화가 가능한 감마선(155keV)을 방출하며 치료용으로 적당한 베타선(2.12MeV)을 동시에 방출하여 혈관성형술 풍선에 넣어 조사하는 접촉 베타선 방출체 치료용 방사성핵종으로 유력하다. 이 연구에서는 Re-188-DTPA를 관상동맥풍선 성형술시 풍선에 주입하는 방사성 동위원소로 쓸 수 있을지 알기 위해 우선 표지법과 풍선에서 혈관내로 샜을 때의 생체내 분포를 조사하였다. Re-188과 DTPA를 표지하는 방법을 확립하였고 표지효율은 95%, 실온과 사람 혈청에서 안정하였다. 마우스의 체내분포와 랫트와 실험견에서 얻은 신장 시간방사능곡선이 Re-188-DTPA가 신장을 통해 빠르게 제거된다는 것을 밝혔다. 이러한 결과는 Re 188-DTPA를 관상동맥의 재협착을 방지하기 위해 관상동맥풍선 성형술시 풍선에 주입하는 방사성 동위원소로 사용하여도 좋음을 시사한다.

  • PDF

고농축 표적을 이용한 비파괴검사용 $^{192}Ir$ 미세초점선원 개발 (Development of $^{192}Ir$ Small-Focal Source for Non-Destructive Testing Application by Using Enriched Target Material)

  • 손광재;홍순복;장경덕;한현수;박울재;이준식;김동학;한근대;박춘득
    • 비파괴검사학회지
    • /
    • 제27권1호
    • /
    • pp.31-37
    • /
    • 2007
  • 하나로와 동위원소 생산시설을 활용하여 비파괴검사용 $^{192}Ir$ 미세초점선원의 생산기술을 개발하였고 현장적용시험을 통하여 개발된 제품의 성능을 확인하였다. 직경 0.5 mm ${\times}$ 높이 0.5 mm인 선원의 개발을 위해 알루미늄 캡슐 압착 방법 및 장치를 개발하여 표적을 제작하였으며, 하나로를 이용한 방사능 생성량을 평가한 결과 약 3.0 Ci 방사능의 선원 제조가 가능함을 확인하였다. 또한 컴퓨터 CPU 및 탄소강에 대한 비파괴검사를 실시하여 투과도계 감도 및 기하학적 불선명도가 비교 대상 선원에 비해 우수함을 확인하였다. 이 선원의 초점크기는 기존의 선원에 비해 매우 작기 때문에 근접 및 접촉촬영과 튜브-튜브시트 용접부의 비파괴검사에 있어 기하학적 불선명도를 최소화 할 수 있을 것이다.

창녕 술정리 동삼층석탑 석재의 원산지 해석 및 표면균열에 관한 연구 (A Study on the Provenance of the Stones and the Surface Cracks in the Suljeongri East Three-story Stone Pagoda, Changnyeong, Korea)

  • 김재환;좌용주
    • 암석학회지
    • /
    • 제19권4호
    • /
    • pp.283-292
    • /
    • 2010
  • 국보 제34호 창녕 술정리 동삼층석탑에는 다수의 수직, 수평, 대각선 균열이 발달하고 있으며, 일부 부재들이 떨어져 나감에 따라 이에 대한 보존처리가 시급한 실정이다. 이 석탑은 중립질이며 등립질 조직을 나타내는 담홍색의 흑운모 화강암을 석재로 사용하였다. 석재에 대한 전암대자율 측정결과 2~9(${\times}10^{-3}$ SI unit) 사이의 값을 가지며, 감마스펙트로미터 측정결과 K는 3~7%, eU는 8~19 ppm, eTh는 11~35 ppm의 범위를 가진다. 석탑이 위치한 인근 화왕산 일대에 분포하는 흑운모 화강암과 석탑의 석재에 대한 암석기재적 특징, 전암대자율 및 감마스펙트로미터 측정 자료를 비교 분석한 결과, 화왕산 서쪽 사면의 등립질 흑운모 화강암이 석탑부재와 가장 유사한 암석으로 판단된다. 석탑에는 수직, 수평 및 대각선 균열이 발달하고 있는데 주로 석탑 하부인 기단부와 1층 탑신을 이루는 부재들에 집중되어 나타난다. 석탑에 사용된 석재는 원래부터 리프트 결과 그레인 결의 방향으로 미세균열이 잘 발달된 암석으로 이 두 결이 균열성장과 그에 따른 손상을 야기한 것으로 판단된다. 수직 균열은 주 압축응력에 평행한 방향으로 석재의 미세균열이 성장한 결과로 해석되는 반면 수평 균열의 경우 주 압축응력에 대한 반발 인장력이 균열의 성장을 촉진시킨 것으로 해석할 수 있다. 한편, 상하 대각선 방향의 균열은 리프트 결과 그레인 결이 부분적으로 사교하면서 나타나는 양상으로 해석된다.

Hot Wall Epitaxy(HWE)법에 의한 CuAlSe2 단결정 박막의 성장과 가전자대 갈라짐에 대한 광전류 연구 (Photocurrent Study on the Splitting of the Valence Band and Growth of CuAlSe2 Single Crystal Thin Film by Hot Wall Epitaxy)

  • 박창선;홍광준;박진성;이봉주;정준우;방진주;김현
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.157-167
    • /
    • 2004
  • A stoichiometric mixture of evaporating materials for $CuAlSe_{2}$ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, $CuAlSe_{2}$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the hot wall epitaxy (HWE) system. The source and substrate temperatures were $680^{\circ}C$ and $410^{\circ}C$, respectively. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of $CuAlSe_{2}$ single crystal thin films measured with Hall effect by van der Pauw method are $9.24{\times}10^{16}cm^{-3}$ and $295cm^{2}/V{\codt}s$ at 293 K, respectively. The temperature dependence of the energy band gap of the $CuAlSe_{2}$ obtained from the absorption spectra was well described by the Varshni's relation, $E_{g}(T)$ = 2.8382 eV - ($8.68{\circ}10^{-4}$ eV/K)$T^{2}$/(T + 155 K). The crystal field and the spin-orbit splitting energies for the valence band of the $CuAlSe_{2}$ have been estimated to be 0.2026 eV and 0.2165 eV at 10 K, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}so$ definitely exists in the ${\Gamma}_{5}$ states of the valence band of the $CuAlSe_{2}$. The three photocurrent peaks observed at 10 K are ascribed to the $A_{1-}$, $B_{1-}$, and $C_{1-}$ exciton peaks for n = 1.

비영어권 외국인 내원객의 조명 신호와 안내서를 이용한 검사방법 개선 효과(흉부 방사선 검사자를 대상으로) (Improvement of Inspection Methods using Lighting Signals and Guidebook for Non-English speaking Foreign Visitors (For chest X-ray Screening Examinees))

  • 곽종혁;최민경;김능균;김아연;김경립
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.577-584
    • /
    • 2020
  • 본 연구는 비영어권의 내원객 수가 나날이 증가하고 있고 그에 따른 방사선 검사 시 언어의 소통 및 의사전달에 한계가 있었다. 이에 검사를 위해 제작한 안내서를 배부 후 설명 전후에 따른 개선 효과를 알아 보았다. 검사 부위 인지 여부는 점수 척도가 통계적 유의성이 없었고 검사의 불편 정도, 호흡 지침 이해 정도, 검사 설명 만족도는 제작한 안내서 설명 전후에 따라 점수 척도가 향상되었으며 통계적 유의성이 있었다. 비영어권 외국인 내원객의 경우 영어나 한국어로 했을 때 보다 자국의 문자로 설명하는 것에 만족하였고, 그 방법 또한 검사실 내 조명 신호를 이용하여 외국인 내원객에게 호흡을 조절해야 하는 시기를 알려 줌으로써 효과적인 검사를 시행할 수 있었다. 향후 다양한 언어 통역 프로그램과 다양한 검사 부위에 따른 안내서 제작과 도구 개발, 방사선사 및 의료진의 외국어 능력 향상 등 여러 관점에서 의사소통 수단이 구현 될 때 비로소 의료서비스 및 영상 의학적 검사의 질이 개선 될 수 있을 것이다. 앞으로 다른 영상의학 검사실에서도 영어나 한국어를 이해하지 못하는 비영어권 외국인을 검사할 때 사용할 수 있는 매뉴얼을 마련하는데 기초 자료로 활용 될 수 있을 것으로 사료 된다.

몬테카를로 전산해석을 이용한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자 계산 (Calculation of the Correction Factors related to the Diameter and Density of the Concrete Core Samples using a Monte Carlo Simulation)

  • 이규영;강보선
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.503-510
    • /
    • 2020
  • 콘크리트는 원자력 시설의 차폐용 구조물로 광범위하게 사용되고 있는 재료이다. 하지만, 시설의 해체 시 양적으로 가장 많이 발생하는 방사성 폐기물이기도하다. 콘크리트는 중성자를 포획하여 다양한 방사성 핵종을 생성하기 때문에 해체 전에 시료를 채취하여 방사능 측정 및 평가를 수행해야 한다. 측정은 주로 HPGe 검출기를 이용하는데 시료의 정확한 방사능 판정을 위해는 기하학적 보정인자, 자가흡수 보정인자, 계측기의 절대효율 등 효과적인 보정인자를 측정치에 반영해야 한다. 보정인자는 기하학적 및 화학적 상태가 실제 시료와 동일한 표준시료를 이용해서 동일한 측정조건 하에서 획득한다. 하지만, 콘크리트는 다양한 구성물질과 높은 밀도로 전처리가 제한적이므로 콘크리트 표준시료를 제작하는 것은 매우 어렵다. 또한 코어드릴(core drill)을 사용하여 채취되는 콘크리트 시료는 체적선원이므로 직경에 대한 기하학적 보정과 밀도에 대한 자가흡수에 대한 보정이 필수적이다. 따라서, 최근에는 많은 연구자들이 표준선원을 제작 후 측정하는 대신 몬테카를로 전산모사(Monte Carlo simulation)을 이용하여 효과적인 보정인자들을 계산하는 연구를 수행하고 있다. 본 연구에서는 Monte Carlo code 중 하나인 Geant4를 이용하여 방사화 콘크리트에서 가장 많이 생성되는 핵종인 152Eu, 60Co에서 방출되는 감마선 에너지에 대한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자를 산출하였다.

단세포 겔 전기영동법을 이용한 사람 림프구 DNA 손상에 대한 복숭아씨 추출물의 방사선 방어효과 평가 (Evaluation of protective effect of peach kernel extracts on radiation-induced DNA damage in human blood lymphocytes in the single cell gel electrophoresis assay)

  • 김진규;박태원;이장주;채영규
    • Journal of Radiation Protection and Research
    • /
    • 제24권2호
    • /
    • pp.93-99
    • /
    • 1999
  • Alkaline single cell gel electrophoresis (SCGE) assay는 일명 혜성분석이라고 부르며 in vivo 와 in vitro 에서 많은 화학적, 생물학적인 인자에 의한 DNA 손상을 감지하는데 유용한 기법으로 각각의 세포에서 DNA 단일 가닥 절단과 알칼리에 약한 장소를 평가하는 새로운 방법으로 인정되고 있다. 단세포 겔 전기영동법 (SCGE)을 사용하여 복숭아씨 추출물이 방사선에 의하여 사람 림프구 DNA에 나타나는 손상을 보호하는 지 여부를 평가하였다. 복숭아씨 추출물로 10 분간 전처리한 림프구를 0, 0.1, 0.3, 0.5, 1.0, 2.0 Gy 의 방사선으로 조사하였고 방사선만을 조사한 림프구 실험군과 비교평가하였다. 혜성분석에서 DNA 가닥 절단에 대한 표식인 tail moment의 증가는 감마선에 대해서 뚜렷한 선량-반응 관계를 나타내었으며 각각의 농도별로 복숭아씨 추출물이 처리된 림프구의 DNA 손상은 현저히 감소하였다. 단세포 겔 전기영동법을 통한 평가결과 복숭아씨 추출물은 방사선에 의한 림프구 DNA 손상에 대한 탁월한 방어효과를 나타내었다.

  • PDF

Combined Effects of Ionizing Radiation and Ultrasound on Malformation in ICR Mice at Organogenesis stage

  • 구연화;하세가와 다케오;모리 다케히코;야마모토 요우치;구사마 토모코
    • Journal of Radiation Protection and Research
    • /
    • 제24권1호
    • /
    • pp.23-30
    • /
    • 1999
  • 태생 8일째인 임신한 생쥐에 137-Cs 감마선과 초음파를 조사하였다. 복합조사의 경우 임신한 생쥐는 1.5 Gy 방사선과 $1.0W/cm^2$ 초음파로 -1, 0, 1, 3, 6 시간 간격으로 조사하였다. 사망과 외부 기형은 태생 18일에 검진하였다. 방사선에 의한 태생 8일의 사망 임계값은 0.5에서 1.0 Gy사이였으며, 초음파는 1.0에서 $1.5W/cm^2$ 사이였다. 태생 후반기의 사망은 방사선과 초음파의 복합 치료에 의해 상승적으로 증가되었다. 방사선에 의한 뇌탈출기형 및 무안구증의 임계값은 각각 0.5에서 1.0Gy사이와 1.0에서 1.5Gy 사이였다 초음파에 의한 뇌탈출기형과 무안구증의 임계값은 각각 1.0에서 $1.5W/cm^2$ 사이와 $1.5W/cm^2$ 이상이었다. 복합치료의 경우는 뇌 탈출기형과 무안구증의 빈도가 상승적으로 증가하였다. 한 시간 간격으로 두 가지 치료를 받은 생쥐에서 뇌 탈출기형과 무안구증의 빈도가 최고치에 도달하였다.

  • PDF

고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구 (A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.487-494
    • /
    • 2020
  • 선원과 검출기 사이의 거리, 검출기 지름, 방사선원의 부피 효과 등에 의해 검출기 입사면에서 입체각(solid angle)의 변화가 생기고 이는 검출기 내부에서의 경로 길이(path length) 차이를 유발하여 검출효율 결정에 영향을 미친다. 유효입체각 계산을 위한 일반적인 분석 방법은 단순한 기하학적 구조를 가진 선원 (60Co)에만 유용하여 본 실험에서는 검출기와 선원 간 거리 window cap 0.5 cm 기준점으로 하여 25 cm 까지 이동 시 켜면서 측정하였다. 또한 표준부피선원 450 ㎖, 1000 ㎖ 마리넬리 비이커는 검출기에 밀착 시켜 측정하였다. 검출기와 동축인 원형 점선원의 경우, 검출기 창으로부터의 거리에 대한 입체 각도의 변화를 측정치와 몬테카를로 시뮬레이션으로 계산 분석 관계의 결과 검출기의 반지름이 선원의 반지름보다 작을 경우, 입체 각도는 선원의 제곱 반지름 대 검출기의 제곱 반지름의 절반과 같다. 입체 각도의 차이는 0.53가 되므로 몬테카를로의 결과는 허용된다. 검출기-선원 간 거리의 역수와의 관계를 나타내었다. 입체각도는 거리에 따라 급격하게 감소함을 확인하였다. 부피선원에 대한 측정치와 시뮬레이션 결과는 거리 0 cm에서 1.01 %이며 거리가 5 cm, 10 cm로 멀어지면 4 % 미만의 차이를 보인다. 거리가 10 cm 일 때 처음으로 계산결과가 측정 결과보다 작아진다. 이는 거리가 멀어질수록 입체각이 작아지고, 에너지가 낮아질수록 감쇠효과가 지수 함수적으로 증가하는 원리가 효율의 계산에 반영되는 것을 확인할 수 있다. 따라서 검출효율은 고체 각도 및 몬테카를로 코드를 사용하기에 충분함을 입증하였다.