• Title/Summary/Keyword: ${\gamma}-ray$

Search Result 1,824, Processing Time 0.032 seconds

The Gamma-Ray Detection Circuit design of RI Use Instrument for Hand Carry (휴대용 RI 이용 계기의 감마선 검출 회로설계)

  • Seong, Nak-Jin;Kim, Sang-Jin;Kim, Ki-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.154-158
    • /
    • 2003
  • In this study, to measure the density of compaction, it is designed to use the 5 gamma-ray detectors. The developed instrument consists of measuring circuits for gamma-rays and thermal neutrons, a high voltage supply unit, stable circuit unit, count circuit unit and a microprocessor. To read count pulse from gamma-ray detectors are very accurate and it can be count to data calibration excluded count of ripple.

  • PDF

Molecular Weight Control of Chitosan Using Gamma Ray and Electron Beam Irradiation

  • Kim, Hyun Bin;Lee, Young Joo;Oh, Seung Hwan;Kang, Phil Hyun;Jeun, Joon Pyo
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.51-54
    • /
    • 2013
  • Chitosan is a useful natural polymer material in many application fields such as biomaterials, water-treatment, agriculture, medication, and food science. However, the poor solubility limits its application. In this study, the effects of radiation on chitosan were investigated using gamma ray and electron beam irradiation. The chemical structure and molecular weight analysis show similar degradation effects of chitosan powder in both gamma ray and electron beam irradiation. However, the radiation irradiated chitosan in $H_2O$ has a lower molecular weight, since the hydroxyl radicals attack the glycosidic bonds. This effect is more clearly shown in the electron beam irradiation results.

Comparative study of the pulse shape discrimination (PSD) performance of pixelated stilbene and plastic scintillator (EJ-276) arrays for a coded-aperture-based hand-held dual-particle imager

  • Jihwan Boo ;Manhee Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1677-1686
    • /
    • 2023
  • As the demand for the detection of special nuclear materials (SNMs) increases, the use of imaging instruments that can sensitively image both gamma-ray and neutron signatures has become necessary. This study compared the pulse shape discrimination (PSD) performance of gamma/neutron events when employing either a pixelated stilbene or a plastic (EJ-276) scintillator array coupled to a silicon photomultiplier (SiPM) array in a dual-particle imager. The stilbene array allowed a lower energy threshold above which neutron and gamma-ray events can be clearly distinguished. A greater number of events can, therefore, be used when forming both gamma-ray and neutron images, which shortens the time required to acquire the images by nearly seven times.

Analysis for the secondary gamma-ray emission for glasses irradiated with various doses of fast neutron: Case study borate and silicate glasses

  • O.L. Tashlykov;V. Yu. Litovchenko;N.M. Aristov;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2366-2372
    • /
    • 2023
  • Are borate and silicate glasses suitable for working as shieling materials against fast neutrons? To correctly answer the above question, some silicate, and borate-based glasses were fabricated and irradiated with various doses of fast neutrons varied between 1.73 and 12.10 MGy. The color and hardness of the fabricated glasses were affected by the fast neutron fluence where the transparent glasses turned colored as well as the hardness of the fabricated glasses was decreased. The gamma-ray spectrometric analysis shows a high activity concentration produced in the barium borate glasses due to the formation of radioisotopes Ba-131 and Ba-133 reaches to 5.92E+05 Bq and 4.25E+03 Bq, respectively for sample Cd-5 Batch 3. Additionally, the gamma-ray spectrometric analysis for the sodium silicate glasses shows low activity concentrations emitted from isotopes formed due to the activation of Y2O3-associated impurities. These activities are low compared to that emitted by barium borate-based glasses.

Development of a real-time mobile gamma-ray measurement system for shipboard use

  • Chang-Jong Kim;Mee Jang;Hyuncheol Kim;Jong-Myoung Lim;Wanno Lee;Gyu-Seong Cho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4077-4082
    • /
    • 2023
  • Large areas must be rapidly screened to monitor radiation in marine environments. For this purpose, this study developed a mobile real-time gamma-ray measurement system for shipboard use and evaluated its performance. The system was developed to measure engine or generator cooling water by installing a canister inside the ship. The minimum detectable activity of the system is about 0.8 Bq/L for a 60 s measurement period, and real-time data transmission and remote control are possible. The system was tested in the field and is currently being installed and operated on ships in service. Such a ship-based real-time gamma-radiation measurement system is suitable for a wide range of marine radiation surveillance applications and is expected to be rapidly deployed.

Genetic Relationship of Mono-cotyledonous Model Plant by Ionizing Irradiation (단자엽 모델 식물의 방사선원 별 처리에 따른 유전적 다형성 분석)

  • Song, Mira;Kim, Sun-Hee;Jang, Duk-Soo;Kang, Si-Yong;Kim, Jin-Baek;Kim, Sang Hoon;Ha, Bo-Keun;Kim, Dong Sub
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.23-29
    • /
    • 2012
  • In this study, we investigated the genetic variation in the general of monocot model plant (rice) in response to various ionizing irradiations including gamma-ray, ion beam and cosmic-ray. The non-irradiated and three irradiated (200 Gy of gamma-ray and 40 Gy of ion beam and cosmic-ray) plants were analyzed by AFLP technique using capillary electrophoresis with ABI3130xl genetic analyzer. The 29 primer combinations tested produced polymorphism results showing a total of 2,238 bands with fragments sizes ranged from 30 bp to 600 bp. The number of polymorphism generated by each primer combinations was varied significantly, ranging from 2 (M-CAC/E-ACG) to 158 (M-CAT/E-AGG) with an average of 77 bands. Polymorphic peaks were detected as 1,269 with an average of 44 per primer combinations. By UPGMA (Unweighted Pair Group Method using Arithmetic clustering) analysis method, the clusters were divided into non-irradiated sample and three irradiated samples at a similarity coefficient of 0.41 and three irradiation samples was subdivided into cosmic-ray and two irradiation samples (200 Gy of gamma-ray and 40 Gy of ion beam) at similarity coefficient of 0.48. Similarity coefficient values ranged from 0.41 to 0.55.

Isolation of Gamma-Induced Rice Mutants with Increased Tolerance to Salt by Anther Culture

  • Lee, In-Sok;Kim, Dong-Sub;Hyun, Do-Yoon;Lee, Sang-Jae;Song, Hi-Sup;Lim, Yong-Pyo;Lee, Young-Il
    • Journal of Plant Biotechnology
    • /
    • v.5 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Doubled haploids have long been recognized as a valuable tool in plant breeding since it not only offers the quickest method of advancing heterozygous breeding lines to homozygosity, but also increased the selection efficiency over conventional procedures due to better discrimination between genotypes within any one generation. Salt tolerant mutants were obtained in rice the variety, 'Hawsungbyeo', through in vitro mutagenesis of in vitro cultured anther-derived calli. Various doses (30, 50, 70 and 90 Gy) of gamma ray were applied to investigate the effect of radiation on callus formation on medium containing 1% NaCl, green plant regeneration, frequency of selected doubled haploid mutants and of the salt tolerant screen. It was demonstrated that the dose of 30 and 50 Gy gamma rays had significant effects on callus formation, regeneration and selection of salt tolerance. No tolerant lines were obtained from non-mutagenized cultures. From gamma ray irradiated cultures, five tolerant lines ($M_2$generation) at germination stage and 13 tolerant lines ($M_3$genoration) at seedling stage were obtained. The frequency of salt tolerant mutants indicates that anther culture applied in connection with gamma rays is an effective way to improve salt tolerance.

Production of Ginsenoside in the Hairy Roots Irradiated by 60Co γ on Panax ginseng C.A Meyer (60Co γ 를 조사한 인삼모상근 돌연변이 세포주의 생장과 Ginsenoside의 생산)

  • Choi, Kyu-Myoung;Kwon, Jung-Hee;Ban, Sung-Hee;Yang, Deok-Cho
    • Journal of Ginseng Research
    • /
    • v.26 no.4
    • /
    • pp.219-225
    • /
    • 2002
  • Study was performed to know the effects of Panax ginseng C.A. Meyer hairy root due to $^{60}$ Co ${\gamma}$-ray irradiation. We irradiated the hairy roots under the various $^{60}$ Co ${\gamma}$-ray; 0.5~4 Krad. The growth of hairy roots is inhibited over 3 Krad treatment. The lateral roots are used as a cell line after removing the apical meristem of hairy roots irradiated below 2 Krad. We selected 206 hairy root cell lines having various different growth rates and forms, and incubated in the 1/2 Murashige & Skoog(MS) medium in the absence of hormone. We selected 10 out of 206 showing superior growth. Among those, ${\gamma}$-GHR 70 and ${\gamma}$-GHR 94 showed higher growth; 34.5, 44.7%, respectively. We observed shapable, sizable characteristics according to the width of the primary roots, the process formation of the lateral roots, and the growth of lateral roots. The discriminable cell line showed that primary root is thinner, and has a vigorous growth. 8 out of 10 had much more contents than control in the aspect of the ginsenoside. ${\gamma}$-GHR 59 and ${\gamma}$-GHR 94 showed higher contents; 19, 16.9%, respectively. Therefore, we selected ${\gamma}$-GHR 70, ${\gamma}$-GHR 94 as a superior cell line in the aspect of ginsenoside contents, and growth among those irradiated by ${\gamma}$-ray. According to content of ginsenoside, Rb$_2$ effective in anticancer has 7.5% of ${\gamma}$-GHR 59. Rc, also effective in anticancer showed 16.2% content increasement of ${\gamma}$-GHR 69. It is thought that those lines will be effective in manufacturing ginsenoside. Gene analysis (VNTRP) related to the mutation is in progress.

An Study on the Structure of Maghemite(${\gamma}$-Fe$_2$O$_3$) I -Rietveld Analysis of Powder XRD Patterns- (마게마이트(${\gamma}$-Fe$_2$O$_3$)대한 연구 I -분말 X-선 회절무늬의 Rietveld 분석-)

  • 신형섭
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.10
    • /
    • pp.1113-1119
    • /
    • 1998
  • Crystal structure of needle-shaped maghemite(${\gamma}$-{{{{ { {Fe }_{2 }O }_{3 } }}) has been studied by the Rieveld analysis of powder X-ray diffraction patterns. The tetragonal space group P41,.3212 and cubic space group P41,.32 have been have been used for the refinement of X-ray diffraction patterns. The crystal system of maghemite is closed to tetragonal more than cubic. The tetragonal lattice parameters are a=8.3460$\AA$ and c=25.034$\AA$ The standard X-ray diffraction pattern of the tetragonal maghemite analyzed with space group P41,.3212 is proposed.

  • PDF

Mechanical properties and radiation shielding performance in concrete with electric arc furnace oxidizing slag aggregate

  • Lim, Hee Seob;Lee, Han Seung;Kwon, Seung Jun
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.4
    • /
    • pp.363-371
    • /
    • 2019
  • In this study, physical properties of normal concrete, magnetite concrete, EAF concrete, and EAF concrete with added iron powder were evaluated and a feasibility of radiation shielding is also evaluated through irradiation tests against X-rays and gamma-rays. While the unit weight of EAF concrete (3.21 t/㎥) appeared lower than that of magnetite concrete (3.50 t/㎥), the results in compressive strength of EAF concrete were greater than those in magnetite and normal concrete. While the radiation transmission rate of normal concrete reaches 26.0% in the X-ray irradiation test, only 6.0% and 9.0% of transmission rate were observed in magnetite concrete and linear relationship with unit volume weight and radiation shielding. In the gamma-ray irradiation test, the performance of EAF and magnetite concretes appeared to be similar. Through the results on the excellent physical properties and radiation shielding performance a potential applicability of EAF concrete to radiation shielding was verified.