• Title/Summary/Keyword: ${\epsilon}-NTU$

Search Result 8, Processing Time 0.069 seconds

Performance Comparison between Indirect Evaporative Cooler and Regenerative Evaporative Cooler made of Plastic/Paper (플라스틱/종이 재질의 간접 증발 소자와 재생 증발 소자 성능 비교)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.88-98
    • /
    • 2016
  • The Korean summer is hot and humid, and air-conditioners consume considerable amounts of electricity. In such cases, the simultaneous use of indirect evaporative coolers may help reduce the sensible heat and save electricity. In this study, heat transfer and pressure drop characteristics of indirect or regenerative evaporative coolers made from plastic/paper are investigated. The results showed that heat and mass transfer model based on the ${\epsilon}-NTU$ method predicted the indirect evaporation efficiencies, cooling capacities and pressure drops adequately. Both for indirect or regenerative evaporative cooler, the indirect evaporation efficiency increased with increasing dry channel inlet temperature or relative humidity. The indirect evaporation efficiency of the regenerative evaporative cooler was larger than that of the indirect evaporative cooler.

Analysis of Heat Transfer Performance of a Gas Cooler of CO2 Heat Pump for Water Heating (온수제조용 CO2 히트펌프의 가스쿨러 열전달 성능 해석)

  • Kwon, Jeong-Tae;Lee, Chang-Kyung;Baek, Dong-Seok;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5317-5322
    • /
    • 2013
  • This study presents a prediction method for heat transfer performance of a gas cooler of $CO_2$ heat pump using ${\epsilon}$-NTU method, and compared the results with the experimental data from the open literature. The heat transfer rate, refrigerant side outlet temperature and water side outlet temperature were calculated by using EES(Engineering Equation Solver)program in multi-tube-in-tube type $CO_2$ heat pump gas cooler. Analysis was performed in two methods : The first method performed without dividing into the test section by applying an analysis of the mean properties(mean analysis). The second method, tube length divided into 50 sections, was applied to the local properties(local analysis). From the present study, a good agreement at the local analysis was obtained between the analytical and experimental results by 0.3~1.1%, 1.31~1.88% and 3.12~5.18% for heat transfer rate, water and refrigerant side outlet temperatures, respectively.

An analytical study on the thermal performance of multi-tube CO2 water heater (다중관형 CO2 급탕열교환기의 열적성능에 대한 해석연구)

  • Chang, Keun Sun;Choi, Youn Sung;Kim, Young-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.23-30
    • /
    • 2016
  • In this study, the heat transfer and pressure drop characteristics were evaluated for multi-tube $CO_2$ water heaters with lengths of 4.5 m and 7.5 m. The evaluation was done using the -NTU method, and the results were compared with experimental data. Water flows through the shell side of the water heater, while $CO_2$ flows through 8 inner tubes. The heater uses a counter-current design to maximize the heat transfer efficiency. The energy balance equation describing the flows of $CO_2$ and water for each node is set up using the section-by-section method. The calculated heat transfer rates agree well with the experimental data within ${\pm}5%$ error. The outlet water temperature decreased linearly with the increase of the water flow rate. The calculated heat transfer rates agreed well with the experimental data within ${\pm}3%$ error. The results show that the heat transfer rate increases almost linearly with the increase of water flow rate or $CO_2$ inlet temperature in both the 4.5-m and 7.5-m water heaters, whereas the water outlet temperature linearly decreases with the increase of the water flow rate. The comparison of the $CO_2$ pressure drop between the calculation and experiment results shows good agreement at the high $CO_2$ flow rate within 5 % error, but the value is about 20 % higher in the experimental pressure drop at the low $CO_2$ flow rate.

U-type Cross-Counter Indirect Evaporative Cooler made of Plastic/Paper (U형 직교 대향류 플라스틱/종이 재질 간접증발소자)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.732-739
    • /
    • 2016
  • In Korea, the summer is hot and humid, and much electricity is consumed for air conditioning. Thus, the simultaneous usage of an indirect evaporative cooler and a common air conditioner could reduce the sensible heat and save electricity. This study developed a U-type cross-counter flow indirect evaporative cooler (IEC) made of plastic and paper. The efficiencies were compared with those of a cross-flow IEC. The specimen was $500mm{\times}500mm{\times}1000mm$. the results show that the indirect evaporation efficiencies of the cross-counter flow sample were 6-21% higher than those of the cross-flow sample. The pressure drops of the cross-counter sample were 51-66% higher. Thermal analysis based on the -NTU method predicted the experimental data within 10%. The electrical energy saved by the use of the cross-counter flow IEC was larger than that of the counter flow IEC, and the difference increases with the velocity. However, the the cross-counter IEC is two times larger than the cross-flow IEC, which may increase the material cost and water usage.

Numerical Study on Heat Transfer Characteristics of Turbulent Flow in Transition Duct (안내덕트 내부 난류유동구조에 따른 열전달 특성변화 수치해석)

  • Yoo, Geun-Jong;Choi, Hoon-Ki;Choi, Kee-Lim
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.923-932
    • /
    • 2011
  • Because of the instability of a flow pattern in the inlet transition square duct (hereinafter referred to as "transition duct") of a heat recovery steam generator (hereinafter referred to as "HRSG") in a combined cycle power plant, the Reynolds number in the first row of a tube bank is differs sharply from that in the sectional area of the transition duct. This causes differences in the heat flux in each tube in the tube bank. The computational fluid dynamics (CFD) predictions provide three-dimensional results for velocity, temperature, and other flow parameters over the entire domain of the duct and HRSG. A renormalization group theory (RNG) based k-${\epsilon}$�� turbulent model is used for obtaining the results cited in this study. A porous media option is used for modeling the tube banks and the number of transfer units method is used for determining the heat transfer characteristics. This study describes a comparison between the numerical simulation results and actual design output.

A Study on the Performance Analysis in the Plate and Shell Heat Exchanger (판각형 열교환기 성능해석에 관한 연구)

  • Seo, M.K.;Park, J.H.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • Heat exchangers are called with important devices which have been widely used in industrial fields. Therefore, the design method for a heat exchanger is an important study in the aspect of energy saving. In this study, performance analyses for two types of plate and shell heat exchangers having a corrugated trapezoid shape of a chevron angle with $45^{\circ}$, were executed and compared with experiments. For this study, the operation liquids were adopted with non-phase changing water. In the analysis, ${\epsilon}-NTU$ method was used for a plate and shell heat exchanger and a program was constructed. Independent variables for a plate and shell heat exchanger are flow rate and inlet temperature. Compared with experimental data, the accuracy of the developed are ${\pm}2.5%\;and\;{\pm}5%$ at the type A and type B in the heat transfer rate, respectively. In the pressure drop, the accuracy of the proposed program for a plate and shell heat exchanger is within ${\pm}3%$ and 5% error bounds for the type A and type B, respectively.

  • PDF

Performance Analysis and Testing of a Cross-Flow Aluminum Heat Exchanger for Kitchen Ventilation (주방환기용 직교류 알루미늄 열교환기의 성능해석 및 시험)

  • Kim N.H.;Cho J.P.;Han S.P.;Choi J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.193-201
    • /
    • 2006
  • Thermal performance model was developed for a cross-flow aluminum heat exchanger with relatively short passage. Appropriate heat transfer coefficient and friction factor equations for laminar channel flow were obtained considering developing regions. The heat exchanger was analyzed using the unmixed cross-flow ${\epsilon}$-NTU relationship considering leak-age between streams. Thermal contact between corrugations and plates was also considered. Tests were separately conducted for two samples - one made of non-treated aluminum sheets, and the other made of varnish-treated ones. The samples were made by stacking corrugations and plates one after another. The model adequately predicted the thermal performance and pressure drop of the non-treated heat exchanger. The thermal performance of the varnish-treated one was $7{\sim}12%$ overpredicted, and the pressure drop of the varnished-treated heat exchanger was $5{\sim}15%$ underpredicted. The air leakage ratio of the non-treated heat exchanger was $23{\sim}26%$. The ratio decreased to less than $10%$ with the varnish treatment.

Impact of Design Parameters on Length and Application Effect of Surface Water Heat Exchanger(SWHE) (지표수 열교환기의 용량과 적용 효과에 대한 설계 인자의 영향)

  • Sohn, Byonghu;Min, Kyong-Chon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Commercial buildings are generally cooling-dominated and therefore reject more heat to a vertical ground heat exchanger(GHE) than they extract over the annual cycle. Shallow ponds can provide a cost-effective means to balance the thermal loads to the ground and to reduce the length of GHE. The objective of this work has been to develop a design tool for surface water heat exchanger(SWHE) submerged in shallow pond. This paper presents the analysis results of the impact of design parameters on the length of SWHE and its application effect on geothermal heat pump(GHP) system using vertical GHE. In order to analysis, We applied ${\epsilon}-NTU$ method on designing the length of SWHE. Analysis results show that the required pipe length of SWHE was decreased with the increase of approach temperature difference and with the decrease of pipe wall thickness. In addition, when the SWHE was applied to the GHP system, the temperature of vertical GHE was more stable than that of standalone GHE system.