• 제목/요약/키워드: ${\delta}$-connected

검색결과 118건 처리시간 0.024초

개방-델타 단권선 변압기를 이용한 새로운 다중 펄스 정류기 시스템 (New Multi-pulse Rectifier Systems Using An Open-Delta Auto-Connected Transformer)

  • 강문식;우병옥
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권5호
    • /
    • pp.278-285
    • /
    • 1999
  • This paper proposes new 12 and 24-pulse rectifier systems using an open-delta auto-connected transformer. This approach employs two static converters to operate it at higher than utility line frequencies and to provide multi-pulse operation. By operating magnetic components at a higher frequency, higher power density can be achieved. A unique feature of the proposed approach is that the magnetic components for the dc-side are also exposed to a higher frequency and these components too are reduced in size. The switching frequency and its harmonic components are absent in the utility input line current. The VA ratings of the transformer and static converter are 0.236/0.292 [pu] and 0.11/0.18 [pu] in 12 and 24-pulse rectifier system, respectively. A finer grade of steel or alternatives can be deployed to increase performance and reduce size further. Analysis, simulations, simulations, design example, and experimental results for a 480[V], 10{kVA] prototype system are presented.

  • PDF

2-TYPE HYPERSURFACES SATISFYING ⟨Δx, x - x0⟩ = const.

  • Jang, Changrim
    • East Asian mathematical journal
    • /
    • 제34권5호
    • /
    • pp.643-649
    • /
    • 2018
  • Let M be a connected n-dimensional submanifold of a Euclidean space $E^{n+k}$ equipped with the induced metric and ${\Delta}$ its Laplacian. If the position vector x of M is decomposed as a sum of three vectors $x=x_1+x_2+x_0$ where two vectors $x_1$ and $x_2$ are non-constant eigenvectors of the Laplacian, i.e., ${\Delta}x_i={\lambda}_ix_i$, i = 1, 2 (${\lambda}_i{\in}R$) and $x_0$ is a constant vector, then, M is called a 2-type submanifold. In this paper we proved that a connected 2-type hypersurface M in $E^{n+1}$ whose postion vector x satisfies ${\langle}{\Delta}x,x-x_0{\rangle}=c$ for a constant c, where ${\langle}$, ${\rangle}$ is the usual inner product in $E^{n+1}$, is of null 2-type and has constant mean curvature and scalar curvature.

델타 결선형 저인덕턴스 BLDC 전동기의 토크 리플 저감을 위한 전류 보상 기법 (Current Compensation Scheme to Reduce Torque Ripples of Delta-connected Low-inductance BLDC Motor Drives)

  • 박도현;이동춘;이형근
    • 전력전자학회논문지
    • /
    • 제22권5호
    • /
    • pp.449-456
    • /
    • 2017
  • This study proposes a method for compensating for the commutation torque ripple of delta-connected brushless DC motors with low inductance based on a current predictions. At the commutation instant, a phase current at the next sampling period is predicted and compared with the reference phase current to determine whether torque ripples will occur or not. If the predicted current cannot reach the reference phase current, the reference current is modified and the relevant voltage reference is produced to reduce the torque ripple. The validity of the proposed method has been verified by simulation and experimental results. The commutation torque ripple has been decreased by 17.7% at 1,000 rpm and 80% load conditions.

ON THE MINIMUM ORDER OF 4-LAZY COPS-WIN GRAPHS

  • Sim, Kai An;Tan, Ta Sheng;Wong, Kok Bin
    • 대한수학회보
    • /
    • 제55권6호
    • /
    • pp.1667-1690
    • /
    • 2018
  • We consider the minimum order of a graph G with a given lazy cop number $c_L(G)$. Sullivan, Townsend and Werzanski [7] showed that the minimum order of a connected graph with lazy cop number 3 is 9 and $k_3{\square}k_3$ is the unique graph on nine vertices which requires three lazy cops. They conjectured that for a graph G on n vertices with ${\Delta}(G){\geq}n-k^2$, $c_L(G){\leq}k$. We proved that the conjecture is true for k = 4. Furthermore, we showed that the Petersen graph is the unique connected graph G on 10 vertices with ${\Delta}(G){\leq}3$ having lazy cop number 3 and the minimum order of a connected graph with lazy cop number 4 is 16.

Step-Up Asymmetrical Nine Phase Delta-Connected Transformer for HVDC Transmission

  • Ammar, Arafet Ben;Ammar, Faouzi Ben
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1920-1929
    • /
    • 2018
  • In order to provide a source for nine phases suitable for 18-pulse ac to dc power, this paper proposes a new structure for a step-up asymmetrical delta-connected transformer for converting three-phase ac power to nine-phase ac power. The design allows for symmetry between the nine output voltages to improve the power quality of the supply current and to minimize the THD. The results show that this new structure proves the equality between the output voltages with $40^{\circ}-{\alpha}$ and $40^{\circ}+{\alpha}$ phase shifting and produces symmetrical output currents. This result in the elimination of harmonics in the network current and provides a simulated THD that is equal to 5.12 %. An experimental prototype of the step-up asymmetrical delta-autotransformer is developed in the laboratory and the obtained results give a network current with a THD that is equal to 5.35%. Furthermore, a finite element analysis with a 3D magnetic field model is made based on the dimensions of the 4kVA, 400 V laboratory prototype three-phase with three-limb delta-autotransformer with a six-stacked-core in each limb. The magnetic distribution flux, field intensity and magnetic energy are carried out under open-circuit operation or load-loss.

과전압에 의한 변압기 철공진 분석 및 방지대책 (Analysis for the Ferroresonance on the Transformer by Overvoltage and Prevention Measures)

  • 윤동현;신동열;차한주
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1543-1550
    • /
    • 2015
  • Ferroresonance is a non-linear vibrational phenomenon that is generated by the electrical interaction of the inductance component with the capacitor component of a certain capacitance as the device of the inductance component such as a transformer is saturated due to the degradation, the waveform distortion of current and voltage, and the oscillation of overcurrent and overvoltage in a system. Recently, ferroresonance was generated from the waveform distortion of current and voltage, or the overvoltage or undervoltage phenomenon caused by the nature of an electrical power system and design technology of the transformer in the three phase transformer system. Hence, in general, ferroresonance analyzed by converting to the LC equivalent circuit. However, in general, the aforementioned analytical method only applies to the resonance phenomenon that is generated by the interaction of the capacitance of bussbar and grounding, and switching as the capacitor component with PT and the transformer as the inductance component in a system. Subsequently, the condition where ferroresonance was generated since overvoltage was supplied as line voltage to the phase voltage and thus the iron core is saturated due to the interconnection between grounded and ungrounded systems could not be analyzed when single phase PT was connected in a ${\Delta}$/Y connection system. In this study, voltage swell in the configuration of grounded circuit of a step-up transformer with the ${\Delta}-{\Delta}$ connection linked to PT for control power and the ferroresonance generated by overvoltage when the line voltage of the ${\Delta}-{\Delta}$ connection was connected to the phase voltage of the grounded Y-Y connection were analyzed using PSCAD / EMTDC through the failure case of the transformer caused by ferroresonance in the system with the ${\Delta}-{\Delta}$/Y-Y connection, and subsequently, the preventive measure of ferroresonance was proposed.

위상제어 정류기에 의한 ${\Delta}$-접속형 싸이크로 컨버어터에 관한 연구 (A Study on the Delta-Connected Cycloconverter by Phase-Controlled Rectifier)

  • 정연택;서영수;이사영;김영춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.456-458
    • /
    • 1991
  • Beacause cycloconverter requires AC power converter each phase, it has the disadvantage of complexity in main system. In this paper, the simple circulating current typed cycloconverter obtained the three variable voltage and variable frequency by delta-connceting the three natual commuatation phase controled rectifiers is constructed.

  • PDF

고압전동기 고정자 권선에서 비파괴와 파괴시험의 비교 (Comparison of Nondestructive and Destructive Tests in High Voltage Motor Stator Windings)

  • 주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2097-2100
    • /
    • 1999
  • Nondestructive and destructive tests were performed the stator windings of three high voltage motors prior to the rewind. Nondestructive tests included ac current increase rate($\Delta$I), dissipation factor(${\Delta}tan{\delta}$), and maximum partial discharge(Qm) The destructive tests included breakdown at three phases with ac voltage. Flashover occurred between the connected winding of endwinding and the stator flame. In two cases creeping discharge occurred between the individual phase windings and the wedges In the stator ends. The results of destructive tests could rarely be determined the breakdown voltage.

  • PDF

Data-driven SIRMs-connected FIS for prediction of external tendon stress

  • Lau, See Hung;Ng, Chee Khoon;Tay, Kai Meng
    • Computers and Concrete
    • /
    • 제15권1호
    • /
    • pp.55-71
    • /
    • 2015
  • This paper presents a novel harmony search (HS)-based data-driven single input rule modules (SIRMs)-connected fuzzy inference system (FIS) for the prediction of stress in externally prestressed tendon. The proposed method attempts to extract causal relationship of a system from an input-output pairs of data even without knowing the complete physical knowledge of the system. The monotonicity property is then exploited as an additional qualitative information to obtain a meaningful SIRMs-connected FIS model. This method is then validated using results from test data of the literature. Several parameters, such as initial tendon depth to beam ratio; deviators spacing to the initial tendon depth ratio; and distance of a concentrated load from the nearest support to the effective beam span are considered. A computer simulation for estimating the stress increase in externally prestressed tendon, ${\Delta}f_{ps}$, is then reported. The contributions of this paper is two folds; (i) it contributes towards a new monotonicity-preserving data-driven FIS model in fuzzy modeling and (ii) it provides a novel solution for estimating the ${\Delta}f_{ps}$ even without a complete physical knowledge of unbonded tendons.

칠제향부환(七製香附丸)이 원발성(原發性) 월경통(月經痛) 환자(患者)의 복부(腹部) 및 수장부(手掌部) 온도(手掌部 溫度)에 미치는 영향(影響) (The effect of Chiljehyangbuhwan on the abdomial & palmar temperature in the primary dysmenorrhea patients)

  • 이창훈;조정훈;장준복;이경섭;윤영진
    • 대한한방체열의학회지
    • /
    • 제5권1호
    • /
    • pp.46-58
    • /
    • 2006
  • Purpose: We intended to observe the relations between Chiljehyangbuhwan and abdominal & palmar temperature according to primary dysmenorrhea severity. Methods: We selected the 100 primary dysmenorrhea patients by the screening tests (first screening test-inquiry, second screening test-clinical test. additionally WHR (Waist-to-Hip ratio) by Inbody 2.0). By the fixed blocked randomization and double blind method, Chiljehyangbuhwan or placebo was administered for 1 menstration period. Finally, 69 patients remainded. Before and after administration, we measured 4 points abdominal temperature (Chon-jung (CV17), Chung-wan(CV12), Kwan-won(CV4). Chung-guk(CV3)) by DITI(DOREX Inc., USA). And then we checked the difference of temperature $({\Delta}T)$ between CV17 and CV12/CV17 and CV4/CV17 and CV3/CV12 and CV4/CV12 and CV3. Also, we measured 2 points (palmar region, upper front of forearm) for the difference of palmar temperature $({\Delta}T)$. Then, we checked palmar temperature minus upper front of forearm temperature and took an average of right and left ${\Delta}T.$ After that. we compared ${\Delta}T$ with primary dysmenorrhea severity evaluated by VRS (verbal rating scale) and MVRS (multidimensional verbal rating scale). In dysmenorrhea severity. we standardized scale score and 3-group-severity by score (mild, moderate. severe). Besides, we compared palmar ${\Delta}T$ with abdominal ${\Delta}T$. For statistics, we used ANOVA and Spearman's rho correlations. SPSS 13.0 for windows. Results: In case of MVRS, though Chiljehyangbuhwan was correlated to abdominal ${\Delta}T$(CV12 and CV3/CV12 and CV4). it was not correlated to palmar ${\Delta}T$. In case of VRS, though Chiljehyangbuhwan was not correlated to abdominal ${\Delta}T$. it was correlated to palmar ${\Delta}T$. However. palmar ${\Delta}T$ was not correlated to abdominal ${\Delta}T$. Statistically they showed significant result (p<0.05). Conclusion: The primary dysmenorrhea patients showed that severity by MVRS was connected with abdominal ${\Delta}T$ (CV12 and CV3/CV12 and CV4) and severity by VRS was connected with palmar ${\Delta}T$ after Chiljehyangbuhwan administration. So we can consider Chiljehyangbuhwan partially effects the abdominal & palmar temperature according primary dysmenorrhea severity. However, palmar temperature was not correlated to abdominal temperature. Therefore, we need further study.

  • PDF