• 제목/요약/키워드: $^{60}Co\{\gamma}-ray$

검색결과 273건 처리시간 0.029초

인삼분말에 대한 살균방법 비교 (The Effective Sterilization of White Ginseng Powder)

  • 성형순;박명한;이광승
    • Journal of Ginseng Research
    • /
    • 제6권2호
    • /
    • pp.143-148
    • /
    • 1982
  • This study was conducted to investigate to select the optimum condition for the sterilization of white ginseng powder. The powder heated at 100-121 $^{\circ}C$ for 1-30 minutes in a autoclave and irradiated at 2450 MHz microwave for 0.5-3.0 minutes was significantly changed in it's color density and become coagulated state, but their sterilizing effect on a general bacteria and 5. coli group were negligible. Meanwhile W- irradiation to the powder with thickness 1.5-10.5mm for 120 minutes was no changes in it's color. coagulated state and sterilizing effect, but 60Co-${\gamma}$ray irradiation at various dose with 0.1-2.0 Mrad was significant effect for sterilization and stability of the powder during the storage for 4 months at 25 $^{\circ}C$. The optimum dose of 60Co-${\gamma}$ ray irradiation was 0.5-0.7 Mrad.

  • PDF

수직형 다엽 콜리메이터의 방사선 조사면 크기 결정을 통한 유용성 연구 (Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size)

  • 이창열;손기홍;신상훈;박승우;이동한;정해조;최문식;오원용;김금배;양광모;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제22권1호
    • /
    • pp.3-11
    • /
    • 2011
  • 본 연구에서는 제작한 수직형 다엽 콜리메이터를 이용하여 방사선치료에 사용되는 Co-60 감마선 및 6 MV 엑스선의 조사면 크기와 모양을 결정하고 동일한 모양 및 크기의 조사면을 납차폐체로 결정하여 방사선 조사면 내 선량분포 특성을 상호 분석하여 수직형 다엽 콜리메이터의 방사선 조사면 크기 결정에 관한 유용성을 평가하였다. 이를 위해 이온전리함, 유리선량계, 방사선크로믹 필름을 사용하여 선량측정 실험을 수행하였다. Co-60 감마선과 6 MV 엑스선에 대하여 기준조사면의 이온전리함 측정결과 수직형 다엽 콜리메이터의 빔 중심축 선량값이 납차폐체의 선량값보다 각각 5.1%, 4.2% 높게 측정되었다. 그리고 Co-60 감마선에 대한 4개 조사면(기준 조사면, 원형, 삼각형, 십자형)의 유리선량계 측정 결과는 수직형 다엽 콜리메이터의 선량값이 납차폐체의 선량값보다 각각 2.2%, 7.8%, 7.2%, 4.0% 높게 측정되었고, 6 MV 엑스선에 대하여는 수직형 다엽 콜리메이터의 선량값이 납차폐체의 선량값보다 각각 6.7%, 6.2%, 3.8%, 6.2% 높게 측정되었다. 방사선크로믹 필름에서 차폐체의 선량분포곡선 중 최대선량의 80%에서 20%까지의 거리를 나타내는 반음영 크기는 모든 조사면에서 수직형 다엽 콜리메이터의 반음영 크기가 납차폐체보다 Co-60의 경우 2.0~3.5 mm, 6 MV 엑스선의 경우 0.5~1.0 mm 작게 나타났으며 이는 제작한 수직형 다엽 콜리메이터가 임상에 사용되었을 때 반음영의 크기를 납차폐체보다 줄일 수 있음으로써 치료 조사면적 결정시 차폐물의 반음영으로 생기는 방사선치료체적(Treatment Volume, TV)을 최소화시킬 수 있는 장점이 있으리라 판단된다. 아울러 2차원 및 3차원 방사선치료 시 본 다엽 콜리메이터를 이용하여 다양한 방사선치료 조사면을 간편하게 결정하여 사용할 수 있으리라 생각된다.

실리콘 핀 포토다이오드를 이용한 전자 선량계의 설계 및 구현 (A Study on the Development of Electronic Personal Dosimeter with Silicon PIN Photodiode)

  • 이운근;권석근;김중선;손창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2285-2288
    • /
    • 2002
  • Recently, electronic personal dosimeters based upon silicon PIN photodiode or miniature GM tube were developed and have attracted a lot of attention because of the advantages of their nature such as indication of dose rate and the cumulative dose, and facilitation of record keeping. In this paper, we have developed a high-sensitivity electronic personal dosimeter with silicon PIN photodiode. The electronic personal dosimeter is constructed with silicon PIN photodiode, preamplifier, and shaping amplifier. To show the effectiveness of electronic personal dosimeter, we conducted nuclear radiation experiments using $\gamma$-ray Ba-133, Cs-137, and Co-60. The electronic personal dosimeter have a good linearity on $\gamma$-ray energy and activity.

  • PDF

감마선 조사에 의한 농약 성분의 분해 연구 (Study on Decomposition of Several Pesticides by Gamma-Irradiation)

  • 이주상;정수연;오승열;장범수;박상현
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.205-209
    • /
    • 2012
  • The decomposition of 50 pesticides present in an aqueous solution using ${\gamma}-irradiation$ from a $^{60}Co$ gamma-ray source was investigated using laboratory-scale experiment. The rates of decomposition were determined using a gas chromatography-electron capture detector (GC-ECD), high-performance liquid chromatography-photo diode array detector (HPLC-PDA), and HPLC-fluorescence detector (FLD). When the initial concentration of pesticides was 10 ppm, and the radiation dose was 2, 5, 10, 20, and 30 kGy, respectively, 14 pesticide samples showed high removal rates (>50%) at absorbed doses of more than 10 kGy. With the exception of procymidone, they were all completely removed at a 30 kGy irradiation dose. These results provide fundamental data on the reactivity between gamma-irradiation and pesticides in an aqueous solution. Further, an evaluation of the toxicity of radiolytic intermediate products is required.

Gamma-ray Dosimetry with Thin Plastic Film

  • Yoo, Young-Soo;Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.223-233
    • /
    • 1973
  • 고준위 gamma선량 측정에 사용할 목적으로 시중에서 판매되고 있는 32종의 국산 plastic film을 수집하여 gamma선량계로서의 효용성 판단기준이 되는 gamma선에 대한 반응도 및 온도효과 등을 조사하였다. Co-60 gamma선을 이용한 실험결과에 의하면 럭키화학회사 제품인 0.06mm두께의 경질 PVC film이 선량계로서 사용하기에 가장 적합한 것 같았다. 3100$\AA$파장에서 측정한 이 PVC film의 optical density는 0.6$\times$$10^{6}$R으로부터 1.3$\times$$10^{7}$ R까지의 구간에서 조사선량에 따라 비례하여 변했으며 표준실첨조건하에서 9%이내의 재현성을 보여 주었다. 한편 흡수선량, 주위 대기중의 산소함량 및 방사선 조사시의 온도효과 등을 조사한 결과 실용적인 관점에서 가장 좋은 특성을 나타냈다.

  • PDF

고에너지 방사선치료용 조직등가보상체에 관한 고찰 (A Study of Tissue-equivalent Compensator for 10MV X-ray and Co-60 Gamma-ray)

  • 최태진;홍영락;임찬수;정호용
    • 대한방사선치료학회지
    • /
    • 제1권1호
    • /
    • pp.47-51
    • /
    • 1985
  • Authors describe some useful data when constructing tissue-equivalent compensators which would compensate tissue deficit in the treatment field of high energy electromagnetic radiation Tissue equivalent compensator is made of lucite. The ratio of compensator thickness to the thickness of tissue deficit depends on radiation energy, field size and the distance from the compensator to patient skin. When the compensator is separated from skin surface, the thickness ratio is always smaller than 1.0. This means that the larger the separation, the contribution to the total dose by means of scattered radiation from a tissue equivalent compensator is smaller. Authors propose that the thickness of lucite as tissue equivalent compensator is 0.57 times tissue deficit and the separation between compensator and skin is at least 15m for Co-60 gamma ray and 25cm for 10MV X-ray.

  • PDF

Flexible liquid light-guide-based radiation sensor with LaBr3:Ce scintillator for remote gamma-ray spectroscopy

  • Jae Hyung Park;Siwon Song;Seunghyeon Kim;Taeseob Lim;Jinhong Kim;Bongsoo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1045-1051
    • /
    • 2023
  • In this study, we fabricated a liquid light-guide-based radiation sensor with a LaBr3:Ce scintillator for remote gamma-ray spectroscopy. We acquired the energy spectra of Cs-137 and Co-60 using the proposed sensor, estimated the energy resolutions of the full energy peaks, and compared the scintillation light output variations. The major peaks of the radionuclides were observed in each result, and the estimated energy resolutions were similar to that of a general NaI(Tl) scintillation detector without a liquid light guide. Moreover, we showed the relationships of energy resolution and analog-to-digital channel regarding the number of photoelectrons produced and confirmed the effects of light guide length on remote gamma-ray spectroscopy. The proposed sensor is expected to be utilized to perform remote gamma-ray spectroscopy for distances of 3 m or more and would find application in many fields of nuclear facilities and industry.

KCCH cyclotron neutron 및 $^{60}Co\;{\gamma}-ray$에 의한 인체 말초혈액 임파구의 염색체 이상측정 (Radiation-Induced Chromosome Aberration in Human Peripheral Blood Lymphocytes In Vitro : RBE Study with Neutrons and $^{60}Co\;{\gamma}-rays$.)

  • 김성호;김태환;정인용;조철구;고경환;류성렬
    • Journal of Radiation Protection and Research
    • /
    • 제17권1호
    • /
    • pp.21-30
    • /
    • 1992
  • KCCH cyclotron neutron(30cCy/min) 및 $^{60}Co\;{\gamma}-ray(210cGy/min)$를 시험관내의 정상인체 말초혈액임파구에 조사하여 염색체이상(dicentric 및 centric ring)을 관찰하고 이의 선량-반응관계식을 linear model$(Y=K_1D+a)$, power-law model$(Y=K_2D^n)$, quadratic model$(Y=K_3D^2)$ 및 linear-quadratic model$(Y={\alpha}D+{\beta}D^2)$을 사용하여 구하고 이들 model중 염색체이상의 측정치와 가장 일치하는 관계식을 근거로 하여 ${\gamma}-ray$에 대한 neutron의 relative biological effectiveness (RBE)를 산출하였다. 염색체 이상(dicentric plus centric ring)의 발생분포는 ${\gamma}-ray$의 경우 linear model(P=0.067)을 제외한 power-law model$[Y=(5.81{\pm}1.96){\times}10^6D^{1.93+0.06},\;P=0.931]$, quadratic model$[Y=(3.91{\pm}0.09){\times}10^{-6}D^2,\;P=0.972]$ 및 linear-quadratic model $[Y=(6.55{\pm}6.83){\times}10^{-5}D+(3.72{\pm}0.22){\times}10^{-6}D^2$ P=0.922]에 적합하였다 neutron의 경우 linear model $(Y=(6.12{\pm}0.17){\times}10^{-3}\;D-0.22,\;P=0.987]$에 가장 일치하였고 quadratic model (P<0.005)을 제외한 power-law model $[Y=(5.36{\pm}3.02) {\times}10^{-4}D^{1.42+0.11},\;P=0.601]$ 및 linear-quadratic model $[Y=(2.43{\pm}0.70){\times}10^{-3}D+(1.21{\pm}0.39){\times}10^{-7}D^2,\;P=0.415]$에 비교적 적합하였다. 세포당 0.1-1.5개의 염색체이상을 나타내는 neutron의 ${\gamma}-ray$에 대한 RBE는 $2.714{\pm}0.408$이었다.

  • PDF

Evaluations of Poly{vinyl alcohol)/Alginate Hydrogels Cross-linked by r-ray Irradiation Technique

  • Nam, Sang-Yong;Nho, Young-Chang;Chae, Gue-Tae;Jang, Hong-Seok;Suh, Tae-Suk;Ahn, Woong-Shick;Ryu, Kyu-Eun;Chun, Heung-Jae
    • Macromolecular Research
    • /
    • 제12권2호
    • /
    • pp.219-224
    • /
    • 2004
  • In this work, we prepared hydrogels for wound dressing from a mixture of poly(vinyl alcohol) (PVA) and alginate using the $\^$60/Co ${\gamma}$-ray irradiation technique. We examined the physical properties of these hydrogels, including gelation, water absorptivity, and gel strength, to evaluate the applicability of these hydrogels for wound dressings. The biocompatibility of these hydrogels was also evaluated in vitro, in cultures of mouse fibroblasts, and in vivo, by subcutaneous implantation studies in rats. The gel content and strength increased upon increasing the radiation dose and upon decreasing the concentration of alginate. The degree of swelling was inversely proportional to the gel content and strength. The degree of cytotoxicity of the ${\gamma}$-ray-treated hydrogels was ca. 60% compared to the (-) control (serum) after 1 day of incubation. When the incubations were prolonged up to 2 days, the toxicity of all the samples decreased remarkably and reached that of the control. Subcutaneous implantation studies in rats indicated that foreign body reactions occurring around the implanted hydrogels were moderate and became minimal upon increasing the implantation time.

광섬유 브래그 격자 센서를 이용한 국내외 상용 단일모드 광섬유의 감마선 영향 연구 (A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber using Fiber Bragg Grating Sensor Systems)

  • 김종열;이남호
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2287-2292
    • /
    • 2012
  • 본 논문에서는 Ge가 함유된 일반 단일모드 광섬유의 감마선 유입손실을 측정하였다. 방사선 선원은 $Co^{60}$ 감마선 선원을 이용하였으며, 총 4시간동안 0.5 kGy/hr, 2 kGy/hr, 8 kGy/hr의 선량률로 조사하였다. 그 결과 감마선 조사에 의한 단일모드 광섬유의 전송손실이 뚜렷하게 나타났으며, 동일 누적선량에서 선량률이 클수록 전송손실이 증가하는 선량률 효과가 나타났다. 또한 감마선 조사 종료 후 광섬유의 전송손실이 클수록 유입손실의 회복률이 증가하는 어닐링 특성을 보였다. 본 실험결과는 향후 광섬유의 내방사화 연구의 기초자료로 활용할 것이다.